6 resultados para Gross operating margin
em DigitalCommons@The Texas Medical Center
Resumo:
In light of the new healthcare regulations, hospitals are increasingly reevaluating their IT integration strategies to meet expanded healthcare information exchange requirements. Nevertheless, hospital executives do not have all the information they need to differentiate between the available strategies and recognize what may better fit their organizational needs. ^ In the interest of providing the desired information, this study explored the relationships between hospital financial performance, integration strategy selection, and strategy change. The integration strategies examined – applied as binary logistic regression dependent variables and in the order from most to least integrated – were Single-Vendor (SV), Best-of-Suite (BoS), and Best-of-Breed (BoB). In addition, the financial measurements adopted as independent variables for the models were two administrative labor efficiency and six industry standard financial ratios designed to provide a broad proxy of hospital financial performance. Furthermore, descriptive statistical analyses were carried out to evaluate recent trends in hospital integration strategy change. Overall six research questions were proposed for this study. ^ The first research question sought to answer if financial performance was related to the selection of integration strategies. The next questions, however, explored whether hospitals were more likely to change strategies or remain the same when there was no external stimulus to change, and if they did change, they would prefer strategies closer to the existing ones. These were followed by a question that inquired if financial performance was also related to strategy change. Nevertheless, rounding up the questions, the last two probed if the new Health Information Technology for Economic and Clinical Health (HITECH) Act had any impact on the frequency and direction of strategy change. ^ The results confirmed that financial performance is related to both IT integration strategy selection and strategy change, while concurred with prior studies that suggested hospital and environmental characteristics are associated factors as well. Specifically this study noted that the most integrated SV strategy is related to increased administrative labor efficiency and the hybrid BoS strategy is associated with improved financial health (based on operating margin and equity financing ratios). On the other hand, no financial indicators were found to be related to the least integrated BoB strategy, except for short-term liquidity (current ratio) when involving strategy change. ^ Ultimately, this study concluded that when making IT integration strategy decisions hospitals closely follow the resource dependence view of minimizing uncertainty. As each integration strategy may favor certain organizational characteristics, hospitals traditionally preferred not to make strategy changes and when they did, they selected strategies that were more closely related to the existing ones. However, as new regulations further heighten revenue uncertainty while require increased information integration, moving forward, as evidence already suggests a growing trend of organizations shifting towards more integrated strategies, hospitals may be more limited in their strategy selection choices.^
Resumo:
PURPOSE: To determine whether a 3-mm isotropic target margin adequately covers the prostate and seminal vesicles (SVs) during administration of an intensity-modulated radiation therapy (IMRT) treatment fraction, assuming that daily image-guided setup is performed just before each fraction. MATERIALS AND METHODS: In-room computed tomographic (CT) scans were acquired immediately before and after a daily treatment fraction in 46 patients with prostate cancer. An eight-field IMRT plan was designed using the pre-fraction CT with a 3-mm margin and subsequently recalculated on the post-fraction CT. For convenience of comparison, dose plans were scaled to full course of treatment (75.6 Gy). Dose coverage was assessed on the post-treatment CT image set. RESULTS: During one treatment fraction (21.4+/-5.5 min), there were reductions in the volumes of the prostate and SVs receiving the prescribed dose (median reduction 0.1% and 1.0%, respectively, p<0.001) and in the minimum dose to 0.1 cm(3) of their volumes (median reduction 0.5 and 1.5 Gy, p<0.001). Of the 46 patients, three patients' prostates and eight patients' SVs did not maintain dose coverage above 70 Gy. Rectal filling correlated with decreased percentage-volume of SV receiving 75.6, 70, and 60 Gy (p<0.02). CONCLUSIONS: The 3-mm intrafractional margin was adequate for prostate dose coverage. However, a significant subset of patients lost SV dose coverage. The rectal volume change significantly affected SV dose coverage. For advanced-stage prostate cancers, we recommend to use larger margins or improve organ immobilization (such as with a rectal balloon) to ensure SV coverage.
Resumo:
This exploratory study was conducted to examine the relationship between nursing home organizational variables and variations in financial efficiency and effectiveness in Texas nursing homes. Efficiency was defined in terms of nursing home profit, contribution margin, and administrative costs. Effectiveness was defined as the level of the quality of care measured by Texas Department of Health annual surveys of Medicaid certified facilities.^ A sample of 318 intermediate care facilities was selected from a population of 1,026 Texas nursing homes operating in 1987. Location was not found to be related to nursing home effectiveness. Nursing home ownership was positively related to financial efficiency. A moderate amount of quality of care variation was explained by examining nursing home size, employee turnover rate, labor hours per patient day and occupancy rate.^ The number of labor hours per patient day and employee turnover rate were significantly related negatively to both measures of profitability and quality of care. ^
Resumo:
A non-parametric method was developed and tested to compare the partial areas under two correlated Receiver Operating Characteristic curves. Based on the theory of generalized U-statistics the mathematical formulas have been derived for computing ROC area, and the variance and covariance between the portions of two ROC curves. A practical SAS application also has been developed to facilitate the calculations. The accuracy of the non-parametric method was evaluated by comparing it to other methods. By applying our method to the data from a published ROC analysis of CT image, our results are very close to theirs. A hypothetical example was used to demonstrate the effects of two crossed ROC curves. The two ROC areas are the same. However each portion of the area between two ROC curves were found to be significantly different by the partial ROC curve analysis. For computation of ROC curves with large scales, such as a logistic regression model, we applied our method to the breast cancer study with Medicare claims data. It yielded the same ROC area computation as the SAS Logistic procedure. Our method also provides an alternative to the global summary of ROC area comparison by directly comparing the true-positive rates for two regression models and by determining the range of false-positive values where the models differ. ^
Resumo:
A community development program operating in the mountains of North India was studied to assess its potential effects on mortality, fertility and migration patterns in the community which it served. The development program operated in Jaunpur Block, Tehri-Garhwal District, Uttar Pradesh State. Two comparable villages in the district were studied. The development program had been working in one for two years, and the other was completely untouched by the program.^ Since not enough time had elapsed since the beginning of the development program's work for any effects on demographic patterns to be visable in Jaunpur Block, this study looked to attitudes of village residents as indicators of future demographic trends. Existing demographic patterns and their interrelationship with socio-religious customs were examined in the test village. A questionnaire was then administered to ascertain attitudinal differences between the residents of the test village and the control village.^ The primary work of the community development program was to train women as village health workers. The results of the attitudinal comparison of the residents of the two villages showed a marked difference in attitudes relating to the position of women in society. The data showed a higher esteem for women in the test village than in the control village, and it is argued that this difference may be attributable to the work of the development program.^ Predicting future demographic trends in Jaunpur Block on the basis of the observed difference in villagers' attitudes toward the status of women is speculatory. Jaunpur Block appears to be in the demographic stage of pre-transition, maintaining relatively high rates of both mortality and fertility. Based on demographic transition theory the next significant change in demographic patterns in Jaunpur is predicted to be a decline in mortality, and an increase in the status of women is unrelated to this prediction.^ The community development program which was studied terminated unexpectedly during the time of this study. A case study of the program's final months is presented, and speculation on the future course of demographic trends in Jaunpur Block is related to the possible alternatives for future development in the area. ^
Resumo:
Radiation therapy for patients with intact cervical cancer is frequently delivered using primary external beam radiation therapy (EBRT) followed by two fractions of intracavitary brachytherapy (ICBT). Although the tumor is the primary radiation target, controlling microscopic disease in the lymph nodes is just as critical to patient treatment outcome. In patients where gross lymphadenopathy is discovered, an extra EBRT boost course is delivered between the two ICBT fractions. Since the nodal boost is an addendum to primary EBRT and ICBT, the prescription and delivery must be performed considering previously delivered dose. This project aims to address the major issues of this complex process for the purpose of improving treatment accuracy while increasing dose sparing to the surrounding normal tissues. Because external beam boosts to involved lymph nodes are given prior to the completion of ICBT, assumptions must be made about dose to positive lymph nodes from future implants. The first aim of this project was to quantify differences in nodal dose contribution between independent ICBT fractions. We retrospectively evaluated differences in the ICBT dose contribution to positive pelvic nodes for ten patients who had previously received external beam nodal boost. Our results indicate that the mean dose to the pelvic nodes differed by up to 1.9 Gy between independent ICBT fractions. The second aim is to develop and validate a volumetric method for summing dose of the normal tissues during prescription of nodal boost. The traditional method of dose summation uses the maximum point dose from each modality, which often only represents the worst case scenario. However, the worst case is often an exaggeration when highly conformal therapy methods such as intensity modulated radiation therapy (IMRT) are used. We used deformable image registration algorithms to volumetrically sum dose for the bladder and rectum and created a voxel-by-voxel validation method. The mean error in deformable image registration results of all voxels within the bladder and rectum were 5 and 6 mm, respectively. Finally, the third aim explored the potential use of proton therapy to reduce normal tissue dose. A major physical advantage of protons over photons is that protons stop after delivering dose in the tumor. Although theoretically superior to photons, proton beams are more sensitive to uncertainties caused by interfractional anatomical variations, and must be accounted for during treatment planning to ensure complete target coverage. We have demonstrated a systematic approach to determine population-based anatomical margin requirements for proton therapy. The observed optimal treatment angles for common iliac nodes were 90° (left lateral) and 180° (posterior-anterior [PA]) with additional 0.8 cm and 0.9 cm margins, respectively. For external iliac nodes, lateral and PA beams required additional 0.4 cm and 0.9 cm margins, respectively. Through this project, we have provided radiation oncologists with additional information about potential differences in nodal dose between independent ICBT insertions and volumetric total dose distribution in the bladder and rectum. We have also determined the margins needed for safe delivery of proton therapy when delivering nodal boosts to patients with cervical cancer.