7 resultados para Calibration uncertainty

em DigitalCommons@The Texas Medical Center


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Proton radiation therapy is gaining popularity because of the unique characteristics of its dose distribution, e.g., high dose-gradient at the distal end of the percentage-depth-dose curve (known as the Bragg peak). The high dose-gradient offers the possibility of delivering high dose to the target while still sparing critical organs distal to the target. However, the high dose-gradient is a double-edged sword: a small shift of the highly conformal high-dose area can cause the target to be substantially under-dosed or the critical organs to be substantially over-dosed. Because of that, large margins are required in treatment planning to ensure adequate dose coverage of the target, which prevents us from realizing the full potential of proton beams. Therefore, it is critical to reduce uncertainties in the proton radiation therapy. One major uncertainty in a proton treatment is the range uncertainty related to the estimation of proton stopping power ratio (SPR) distribution inside a patient. The SPR distribution inside a patient is required to account for tissue heterogeneities when calculating dose distribution inside the patient. In current clinical practice, the SPR distribution inside a patient is estimated from the patient’s treatment planning computed tomography (CT) images based on the CT number-to-SPR calibration curve. The SPR derived from a single CT number carries large uncertainties in the presence of human tissue composition variations, which is the major drawback of the current SPR estimation method. We propose to solve this problem by using dual energy CT (DECT) and hypothesize that the range uncertainty can be reduced by a factor of two from currently used value of 3.5%. A MATLAB program was developed to calculate the electron density ratio (EDR) and effective atomic number (EAN) from two CT measurements of the same object. An empirical relationship was discovered between mean excitation energies and EANs existing in human body tissues. With the MATLAB program and the empirical relationship, a DECT-based method was successfully developed to derive SPRs for human body tissues (the DECT method). The DECT method is more robust against the uncertainties in human tissues compositions than the current single-CT-based method, because the DECT method incorporated both density and elemental composition information in the SPR estimation. Furthermore, we studied practical limitations of the DECT method. We found that the accuracy of the DECT method using conventional kV-kV x-ray pair is susceptible to CT number variations, which compromises the theoretical advantage of the DECT method. Our solution to this problem is to use a different x-ray pair for the DECT. The accuracy of the DECT method using different combinations of x-ray energies, i.e., the kV-kV, kV-MV and MV-MV pair, was compared using the measured imaging uncertainties for each case. The kV-MV DECT was found to be the most robust against CT number variations. In addition, we studied how uncertainties propagate through the DECT calculation, and found general principles of selecting x-ray pairs for the DECT method to minimize its sensitivity to CT number variations. The uncertainties in SPRs estimated using the kV-MV DECT were analyzed further and compared to those using the stoichiometric method. The uncertainties in SPR estimation can be divided into five categories according to their origins: the inherent uncertainty, the DECT modeling uncertainty, the CT imaging uncertainty, the uncertainty in the mean excitation energy, and SPR variation with proton energy. Additionally, human body tissues were divided into three tissue groups – low density (lung) tissues, soft tissues and bone tissues. The uncertainties were estimated separately because their uncertainties were different under each condition. An estimate of the composite range uncertainty (2s) was determined for three tumor sites – prostate, lung, and head-and-neck, by combining the uncertainty estimates of all three tissue groups, weighted by their proportions along typical beam path for each treatment site. In conclusion, the DECT method holds theoretical advantages in estimating SPRs for human tissues over the current single-CT-based method. Using existing imaging techniques, the kV-MV DECT approach was capable of reducing the range uncertainty from the currently used value of 3.5% to 1.9%-2.3%, but it is short to reach our original goal of reducing the range uncertainty by a factor of two. The dominant source of uncertainties in the kV-MV DECT was the uncertainties in CT imaging, especially in MV CT imaging. Further reduction in beam hardening effect, the impact of scatter, out-of-field object etc. would reduce the Hounsfeld Unit variations in CT imaging. The kV-MV DECT still has the potential to reduce the range uncertainty further.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study compared four alternative approaches (Taylor, Fieller, percentile bootstrap, and bias-corrected bootstrap methods) to estimating confidence intervals (CIs) around cost-effectiveness (CE) ratio. The study consisted of two components: (1) Monte Carlo simulation was conducted to identify characteristics of hypothetical cost-effectiveness data sets which might lead one CI estimation technique to outperform another. These results were matched to the characteristics of an (2) extant data set derived from the National AIDS Demonstration Research (NADR) project. The methods were used to calculate (CIs) for data set. These results were then compared. The main performance criterion in the simulation study was the percentage of times the estimated (CIs) contained the “true” CE. A secondary criterion was the average width of the confidence intervals. For the bootstrap methods, bias was estimated. ^ Simulation results for Taylor and Fieller methods indicated that the CIs estimated using the Taylor series method contained the true CE more often than did those obtained using the Fieller method, but the opposite was true when the correlation was positive and the CV of effectiveness was high for each value of CV of costs. Similarly, the CIs obtained by applying the Taylor series method to the NADR data set were wider than those obtained using the Fieller method for positive correlation values and for values for which the CV of effectiveness were not equal to 30% for each value of the CV of costs. ^ The general trend for the bootstrap methods was that the percentage of times the true CE ratio was contained in CIs was higher for the percentile method for higher values of the CV of effectiveness, given the correlation between average costs and effects and the CV of effectiveness. The results for the data set indicated that the bias corrected CIs were wider than the percentile method CIs. This result was in accordance with the prediction derived from the simulation experiment. ^ Generally, the bootstrap methods are more favorable for parameter specifications investigated in this study. However, the Taylor method is preferred for low CV of effect, and the percentile method is more favorable for higher CV of effect. ^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A detailed microdosimetric characterization of the M. D. Anderson 42 MeV (p,Be) fast neutron beam was performed using the techniques of microdosimetry and a 1/2 inch diameter Rossi proportional counter. These measurements were performed at 5, 15, and 30 cm depths on the central axis, 3 cm inside, and 3 cm outside the field edge for 10 $\times$ 10 and 20 $\times$ 20 cm field sizes. Spectra were also measured at 5 and 15 cm depth on central axis for a 6 $\times$ 6 cm field size. Continuous slowing down approximation calculations were performed to model the nuclear processes that occur in the fast neutron beam. Irradiation of the CR-39 was performed using a tandem electrostatic accelerator for protons of 10, 6, and 3 MeV and alpha particles of 15, 10, and 7 MeV incident energy on target at angles of incidence from 0 to 85 degrees. The critical angle as well as track etch rate and normal incidence diameter versus linear energy transfer (LET) were obtained from these measurements. The bulk etch rate was also calculated from these measurements. Dose response of the material was studied, and the angular distribution of charged particles created by the fast neutron beam was measured with CR-39. The efficiency of CR-39 was calculated versus that of the Rossi chamber, and an algorithm was devised for derivation of LET spectra from the major and minor axis dimensions of the observed tracks. The CR-39 was irradiated in the same positions as the Rossi chamber, and the derived spectra were compared directly. ^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. Screening for colorectal cancer (CRC) is considered cost effective but screening compliance in the US remains low. There have been very few studies on economic analyses of screening promotion strategies for colorectal cancer. The main aim of the current study is to conduct a cost effectiveness analysis (CEA) and examine the uncertainty involved in the results of the CEA of a tailored intervention to promote screening for CRC among patients of a multispeciality clinic in Houston, TX. ^ Methods. The two intervention arms received a PC based tailored program and web based educational information to promote CRC screening. The incremental cost of implementing a tailored PC based program was compared to the website based education and the status quo of no intervention for each unit of effect after 12 months of delivering the intervention. Uncertainty analysis in the point estimates of cost and effect was conducted using nonparametric bootstrapping. ^ Results. The cost of implementing a web based educational intervention was $36.00 per person and the cost of the tailored PC based interactive intervention was $43.00 per person. The additional cost per person screened for the web-based strategy was $2374 and the effect of the tailored intervention was negative. ^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Uncertainty has been found to be a major component of the cancer experience and can dramatically affect psychosocial adaptation and outcomes of a patient's disease state (McCormick, 2002). Patients with a diagnosis of Carcinoma of Unknown Primary (CUP) may experience higher levels of uncertainty due to the unpredictability of current and future symptoms, limited treatment options and an undetermined life expectancy. To date, only one study has touched upon uncertainty and its' effects on those with CUP but no information exists concerning the effects of uncertainty regarding diagnosis and treatment on the distress level and psychosocial adjustment of this population (Parker & Lenzi, 2003). ^ Mishel's Uncertainty in Illness Theory (1984) proposes that uncertainty is preceded by three variables, one of which being Structure Providers. Structure Providers include credible authority, the degree of trust and confidence the patient has with their doctor, education and social support. It was the goal of this study to examine the relationship between uncertainty and Structure Providers to support the following hypotheses: (1) There will be a negative association between credible authority and uncertainty, (2) There will be a negative association between education level and uncertainty, and (3) There will be a negative association between social support and uncertainty. ^ This cross-sectional analysis utilized data from 219 patients following their initial consultation with their oncologist. Data included the Mishel Uncertainty in Illness Scale (MUIS) which was used to determine patients' uncertainty levels, the Medical Outcomes Study-Social Support Scale (MOSS-SSS) to assess patients, levels of social support, the Patient Satisfaction Questionnaire (PSQ-18) and the Cancer Diagnostic Interview Scale (CDIS) to measure credible authority and general demographic information to assess age, education, marital status and ethnicity. ^ In this study we found that uncertainty levels were generally higher in this sample as compared to other types of cancer populations. And while our results seemed to support most of our hypothesis, we were only able to show significant associations between two. The analyses indicated that credible authority measured by both the CDIS and the PSQ was a significant predictor of uncertainty as was social support measured by the MOSS-SS. Education has shown to have an inconsistent pattern of effect in relation to uncertainty and in the current study there was not enough data to significantly support our hypothesis. ^ The results of this study generally support Mishel's Theory of Uncertainty in Illness and highlight the importance of taking into consideration patients, psychosocial factors as well as employing proper communication practices between physicians and their patients.^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High-resolution, small-bore PET systems suffer from a tradeoff between system sensitivity, and image quality degradation. In these systems long crystals allow mispositioning of the line of response due to parallax error and this mispositioning causes resolution blurring, but long crystals are necessary for high system sensitivity. One means to allow long crystals without introducing parallax errors is to determine the depth of interaction (DOI) of the gamma ray interaction within the detector module. While DOI has been investigated previously, newly available solid state photomultipliers (SSPMs) well-suited to PET applications and allow new modules for investigation. Depth of interaction in full modules is a relatively new field, and so even if high performance DOI capable modules were available, the appropriate means to characterize and calibrate the modules are not. This work presents an investigation of DOI capable arrays and techniques for characterizing and calibrating those modules. The methods introduced here accurately and reliably characterize and calibrate energy, timing, and event interaction positioning. Additionally presented is a characterization of the spatial resolution of DOI capable modules and a measurement of DOI effects for different angles between detector modules. These arrays have been built into a prototype PET system that delivers better than 2.0 mm resolution with a single-sided-stopping-power in excess of 95% for 511 keV g's. The noise properties of SSPMs scale with the active area of the detector face, and so the best signal-to-noise ratio is possible with parallel readout of each SSPM photodetector pixel rather than multiplexing signals together. This work additionally investigates several algorithms for improving timing performance using timing information from multiple SSPM pixels when light is distributed among several photodetectors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Applying Theoretical Constructs to Address Medical Uncertainty Situations involving medical reasoning usually include some level of medical uncertainty. Despite the identification of shared decision-making (SDM) as an effective technique, it has been observed that the likelihood of physicians and patients engaging in shared decision making is lower in those situations where it is most needed; specifically in circumstances of medical uncertainty. Having identified shared decision making as an effective, yet often a neglected approach to resolving a lack of information exchange in situations involving medical uncertainty, the next step is to determine the way(s) in which SDM can be integrated and the supplemental processes that may facilitate its integration. SDM involves unique types of communication and relationships between patients and physicians. Therefore, it is necessary to further understand and incorporate human behavioral elements - in particular, behavioral intent - in order to successfully identify and realize the potential benefits of SDM. This paper discusses the background and potential interaction between the theories of shared decision-making, medical uncertainty, and behavioral intent. Identifying Shared Decision-Making Elements in Medical Encounters Dealing with Uncertainty A recent summary of the state of medical knowledge in the U.S. reported that nearly half (47%) of all treatments were of unknown effectiveness, and an additional 7% involved an uncertain tradeoff between benefits and harms. Shared decision-making (SDM) was identified as an effective technique for managing uncertainty when two or more parties were involved. In order to understand which of the elements of SDM are used most frequently and effectively, it is necessary to identify these key elements, and understand how these elements related to each other and the SDM process. The elements identified through the course of the present research were selected from basic principles of the SDM model and the “Data, Information, Knowledge, Wisdom” (DIKW) Hierarchy. The goal of this ethnographic research was to identify which common elements of shared decision-making patients are most often observed applying in the medical encounter. The results of the present study facilitated the understanding of which elements patients were more likely to exhibit during a primary care medical encounter, as well as determining variables of interest leading to more successful shared decision-making practices between patients and their physicians. Understanding Behavioral Intent to Participate in Shared Decision-Making in Medically Uncertain Situations Objective: This article describes the process undertaken to identify and validate behavioral and normative beliefs and behavioral intent of men between the ages of 45-70 with regard to participating in shared decision-making in medically uncertain situations. This article also discusses the preliminary results of the aforementioned processes and explores potential future uses of this information which may facilitate greater understanding, efficiency and effectiveness of doctor-patient consultations.Design: Qualitative Study using deductive content analysisSetting: Individual semi-structure patient interviews were conducted until data saturation was reached. Researchers read the transcripts and developed a list of codes.Subjects: 25 subjects drawn from the Philadelphia community.Measurements: Qualitative indicators were developed to measure respondents’ experiences and beliefs related to behavioral intent to participate in shared decision-making during medical uncertainty. Subjects were also asked to complete the Krantz Health Opinion Survey as a method of triangulation.Results: Several factors were repeatedly described by respondents as being essential to participate in shared decision-making in medical uncertainty. These factors included past experience with medical uncertainty, an individual’s personality, and the relationship between the patient and his physician.Conclusions: The findings of this study led to the development of a category framework that helped understand an individual’s needs and motivational factors in their intent to participate in shared decision-making. The three main categories include 1) an individual’s representation of medically uncertainty, 2) how the individual copes with medical uncertainty, and 3) the individual’s behavioral intent to seek information and participate in shared decision-making during times of medically uncertain situations.