23 resultados para Customised Maxillo-Facial Prostheses design

em BORIS: Bern Open Repository and Information System - Berna - Sui


Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIMS: To identify the rates and reasons for plate removal (PR) among patients treated for facial fractures. MATERIALS AND METHODS: A retrospective review of files of 238 patients. RESULTS: Forty-eight patients (20.2%) had plates removed. The reason for removal was objective in 33.3% and subjective in 29.2%. The most common subjective reason was cold sensitivity, and the most common objective reason was wound dehiscence/infection. Women had PR for subjective reasons more often than men (p=0.018). Removal was performed more often for subjective reasons after zygomatico-orbital fractures than after mandibular fractures (p=0.002). Plates inserted in the mandible from an intraoral approach were removed more frequently than extraorally inserted mandibular plates, intraorally inserted maxillary plates, and extraorally inserted plates in other locations (p<0.001). Orbital rim plates had a higher risk of being removed than maxillary or frontal bone plates (p=0.02). CONCLUSIONS: Subjective discomfort is a notable reason for PR among Finnish patients, suggesting that the cold climate has an influence on the need for removal. Patients receiving mandibular osteosynthesis with miniplates from an intraoral approach are at risk of hardware removal because of wound dehiscence/infection and loose/broken hardware, reminding us that more rigid fixation devices should not be forgotten despite the widespread use of miniplates.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Placement of a single-tooth implant should be performed when a patient's facial growth has ceased. In this retrospective observational study, we evaluated if there was a difference in the timing of cessation of craniofacial growth in short, average, and long facial types. Based on the value of the angle between cranial base and mandibular plane (SN/MP angle), three groups comprising 48 subjects with short facial type (SF; SN/MP ≤28°), 77 with average facial type (AF; SN/MP ≥31.5° and ≤34.5°), and 44 with long facial type (LF; SN/MP ≥38°) were selected. Facial growth was assessed on lateral cephalograms taken at 15.4 years of age, and 2, 5, and 10 years later. Variables were considered to be stable when the difference between two successive measurements was less than 1 mm or 1°. We found no difference between facial types in the timing of cessation of facial growth. Depending on the variable, the mean age when variables became stable ranged from 18.0 years (Is-Pal in LF group) to 22.0 years (SN/MP in LF group). However, facial growth continued at the last follow-up in approximately 20% subjects. This study demonstrates that facial type is not associated with the timing of cessation of facial growth.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Bisphosphonates (BPs) are powerful drugs that inhibit bone metabolism. Adverse side effects are rare but potentially severe such as bisphosphonate-related osteonecrosis of the jaw (BRONJ). To date, research has primarily focused on the development and progression of BRONJ in cancer patients with bone metastasis, who have received high dosages of BPs intravenously. However, a potential dilemma may arise from a far larger cohort, namely the millions of osteoporosis patients on long-term oral BP therapy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Refinement in microvascular reconstructive techniques over the last 30 years has enabled an increasing number of patients to be rehabilitated for both functional and aesthetic reasons. The purpose of this study was to evaluate different microsurgical practice, including perioperative management, in Germany, Austria, and Switzerland. The DÖSAK collaborative group for Microsurgical Reconstruction developed a detailed questionnaire which was circulated to units in the three countries. The current practice of the departments was evaluated. Thirty-eight questionnaires were completed resulting in a 47.5% response rate. A considerable variation in the number of microsurgical reconstructions per year was noted. In relation to the timing of bony reconstruction, 10 hospitals did reconstructions primarily (26.3%), 19 secondarily (50%) and 9 (23.7%) hospitals used both concepts. In the postoperative course, 15.8% of hospitals use inhibitors of platelet aggregation, most hospitals use low molecular heparin (52.6%) or other heparin products (44.7%). This survey shows variation in the performance, management, and care of microsurgical reconstructions of patients. This is due in part to the microvascular surgeons available in the unit but it is also due to different types of hospitals where various types of care can be performed in these patients needing special perioperative care.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Several studies have reported certain bone morphogenic proteins (BMPs) to have positive effects on bone generation. Although some investigators have studied the effects of human recombinant BMP (rhBMP-2) in sinus augmentation in sheep, none of these studies looked at the placement of implants at the time of sinus augmentation. Furthermore, no literature could be found to report on the impact that different implant systems, as well as the positioning of the implants had on bone formation if rhBMP-2 was utilized in sinus-lift procedures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To clarify the occurrence, sites, and types of associated injuries in paediatric patients with fractures of the anterior skull base.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Whipple's disease is a systemic disorder caused by an infection with a gram-positive bacillus, Tropheryma whipplei. Almost every organ system can be affected in Whipple's disease, resulting in varying clinical symptoms. CASE REPORT: As far as we are aware, this report of a 61-year-old male is the first presenting with a periorbital manifestation of the disease, with severe exophthalmos and optic nerve involvement, leading to rapid visual loss. This emergency case was successfully treated by a surgical orbital decompression combined with systemic use of antibiotics and steroids. CONCLUSION: Whipple's disease can affect the periorbital tissues and the optic nerve, causing massive exophthalmos and serious transient visual loss. In such a case surgical decompression of the affected orbit combined with antibiotics and steroids is a recommended valid treatment option.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIM: The aim of this study was to analyse the character of assault-related facial fractures in central Switzerland and to compare their prevalence with the data presented in similar reports from other countries. MATERIAL: The present study comprised 65 patients with assault-related maxillofacial fractures treated in the Department of Cranio-Maxillofacial Surgery, University Hospital of Bern between 2000 and 2002. METHODS: The mechanism, the causes of the injuries and the location of the fractures were analysed by reviewing emergency and hospital records. Concomitant injuries were also studied. RESULTS: The mean age of the patients was 33 years with the largest group being below 25 years. The male-to-female ratio was 56:9. The most common causes of assault-related injuries were fights, most frequently facial blows, accounting for 92.5% of all patients. Seventy-six per cent of the fractures occurred in the middle and upper facial skeleton with a predominance of 2:1 for the left side. In 39 patients (60%) surgery was necessary, with a mean hospital stay of 3.3 days. Thirty-five patients (54%) had concomitant injuries. Alcohol and drug abuse was found in 15 patients (23%). CONCLUSION: It seems that mostly young men suffer assault-related maxillofacial injuries. A contributing factor to the increased disposition for violence could be alcohol and drug abuse. Therefore, national prevention programmes for alcohol or drug abuse and addiction might have a positive effect on reducing the incidence of assault-related maxillofacial injuries.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE To compare the initial stability and stability after fatigue of three different locking systems (Synthes(®), Stryker(®) and Medartis(®)) for mandibular fixation and reconstruction. METHOD Standard mandible locking plates with identical profile height (1,5 mm), comparable length and screws with identical diameter (2,0 mm) were used. Plates were fixed with six screws according a preparation protocol. Four point bending tests were then performed using artificial bone material to compare their initial stability and failure limit under realistic loading conditions. Loading of the plates was performed using of a servo hydraulic driven testing machine. The stiffness of the implant/bone construct was calculated using a linear regression on the experimental data included in a range of applied moment between 2 Nm and 6 Nm. RESULTS No statistical difference in the elastic stiffness was visible between the three types of plate. However, differences were observed between the systems concerning the maximal load supported. The Stryker and Synthes systems were able to support a significantly higher moment. CONCLUSION For clinical application all systems show good and reliable results. Practical aspects such as handling, possible angulation of screw fixation, possibility of screw/plate removal, etc. may favour one or the other plating system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Biodegradable magnesium plate/screw osteosynthesis systems were implanted on the frontal bone of adult miniature pigs. The chosen implant geometries were based on existing titanium systems used for the treatment of facial fractures. The aim of this study was to evaluate the in vivo degradation and tissue response of the magnesium alloy WE43 with and without a plasma electrolytic surface coating. Of 14 animals, 6 received magnesium implants with surface modification (coated), 6 without surface modification (uncoated), and 2 titanium implants. Radiological examination of the skull was performed at 1, 4, and 8 weeks post-implantation. After euthanasia at 12 and 24 weeks, X-ray, computed tomography, and microfocus computed tomography analyses and histological and histomorphological examinations of the bone/implant blocks were performed. The results showed a good tolerance of the plate/screw system without wound healing disturbance. In the radiological examination, gas pocket formation was found mainly around the uncoated plates 4 weeks after surgery. The micro-CT and histological analyses showed significantly lower corrosion rates and increased bone density and bone implant contact area around the coated screws compared to the uncoated screws at both endpoints. This study shows promising results for the further development of coated magnesium implants for the osteosynthesis of the facial skeleton.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to compare facial development in subjects with complete unilateral cleft lip and palate (CUCLP) treated with two different surgical protocols. Lateral cephalometric radiographs of 61 patients (42 boys, 19 girls; mean age, 10.9 years; SD, 1) treated consecutively in Warsaw with one-stage repair and 61 age-matched and sex-matched patients treated in Oslo with two-stage surgery were selected to evaluate craniofacial morphology. On each radiograph 13 angular and two ratio variables were measured in order to describe hard and soft tissues of the facial region. The analysis showed that differences between the groups were limited to hard tissues – the maxillary prominence in subjects from the Warsaw group was decreased by almost 4° in comparison with the Oslo group (sella-nasion-A-point (SNA) = 75.3° and 79.1°, respectively) and maxillo-mandibular morphology was less favorable in the Warsaw group than the Oslo group (ANB angle = 0.8° and 2.8°, respectively). The soft tissue contour was comparable in both groups. In conclusion, inter-group differences suggest a more favorable outcome in the Oslo group. However, the distinctiveness of facial morphology in background populations (ie, in Poles and Norwegians) could have contributed to the observed results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To evaluate the use of computer-assisted designed and manufactured (CAD/CAM) orbital wall and floor implants for late reconstruction of extensive orbital fractures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: To evaluate the biological and technical complication rates of fixed dental prostheses (FDP) with end abutments or cantilever extensions on teeth (FDP-tt/cFDP-tt) on implants (FDP-ii/cFDP-ii) and tooth-implant-supported (FDP-ti/cFDP-ti) in patients treated for chronic periodontitis. Material and methods: From a cohort of 392 patients treated between 1978 and 2002 by graduate students, 199 were re-examined in 2005. Of these, 84 patients had received ceramo-metal FDPs (six groups). Results: At the re-evaluation, the mean age of the patients was 62 years (36.2–83.4). One hundred and seventy-five FDPs were seated (82 FDP-tt, 9 FDP-ii, 20 FDP-ti, 39 cFDP-tt, 15 cFDP-ii, 10 cFDP-ti). The mean observation time was 11.3 years; 21 FDPs were lost, and 46 technical and 50 biological complications occurred. Chances for the survival of the three groups of FDPs with end abutments were very high (risk for failure 2.8%, 0%, 5.6%). The probability to remain without complications and/or failure was 70.3%, 88.9% and 74.7% in FDPs with end abutments, but 49.8–25% only in FDPs with extensions at 10 years. Conclusions: In patients treated for chronic periodontitis and provided with ceramo-metal FDPs, high survival rates, especially for FDPs with end abutments, can be expected. The incidence rates of any negative events were increased drastically in the three groups with extension cFDPs (tt, ii, ti). Strategic decisions in the choice of a particular FDP design and the choice of teeth/implants as abutments appear to influence the risks for complications to be expected with fixed reconstruction. If possible, extensions on tooth abutments should be avoided or used only after a cautious clinical evaluation of all options.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To analyze maintenance service of fixed maxillary prostheses and overdentures based on conventional gold bars or titanium bars and frameworks fabricated with computer-aided design/computer-assisted manufacture (CAD/CAM) technology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Excessive cantilever lengths of fixed implant-supported prostheses may have functional and biomechanical disadvantages. This study reports the clinical outcomes of unconventional implants placed for distal support of a fixed implant-supported prostheses. Seven extraoral implants with intraosseous lengths of 2.5 to 4.0 mm were placed in four patients. Distal cantilevers had a mean length of 29.8 mm (range, 18.6 to 39.3 mm). No bone loss or other adverse events were found. The prosthetic plan was maintained in all patients. Within the limits of the employed research design, this concept seems to be a successful option for fixed complete implant-supported prosthesis treatment.