23 resultados para two-centre holographic recording

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to compare craniofacial morphology and soft tissue profiles in patients with complete bilateral cleft lip and palate at 9 years of age, treated in two European cleft centres with delayed hard palate closure but different treatment protocols. The cephalometric data of 83 consecutively treated patients were compared (Gothenburg, N=44; Nijmegen, N=39). In total, 18 hard tissue and 10 soft tissue landmarks were digitized by one operator. To determine the intra-observer reliability 20 cephalograms were digitized twice with a monthly interval. Paired t-test, Pearson correlation coefficients and multiple regression models were applied for statistical analysis. Hard and soft tissue data were superimposed using the Generalized Procrustes Analysis. In Nijmegen, the maxilla was protrusive for hard and soft tissue values (P=0.001, P=0.030, respectively) and the maxillary incisors were retroclined (P<0.001), influencing the nasolabial angle, which was increased in comparison with Gothenburg (P=0.004). In conclusion, both centres showed a favourable craniofacial form at 9-10 years of age, although there were significant differences in the maxillary prominence, the incisor inclination and soft tissue cephalometric values. Follow-up of these patients until facial growth has ceased, may elucidate components for outcome improvement.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIMS: It is unclear whether transcatheter aortic valve implantation (TAVI) addresses an unmet clinical need for those currently rejected for surgical aortic valve replacement (SAVR) and whether there is a subgroup of high-risk patients benefiting more from TAVI compared to SAVR. In this two-centre, prospective cohort study, we compared baseline characteristics and 30-day mortality between TAVI and SAVR in consecutive patients undergoing invasive treatment for aortic stenosis. METHODS AND RESULTS: We pre-specified different adjustment methods to examine the effect of TAVI as compared with SAVR on overall 30-day mortality: crude univariable logistic regression analysis, multivariable analysis adjusted for baseline characteristics, analysis adjusted for propensity scores, propensity score matched analysis, and weighted analysis using the inverse probability of treatment (IPT) as weights. A total of 1,122 patients were included in the study: 114 undergoing TAVI and 1,008 patients undergoing SAVR. The crude mortality rate was greater in the TAVI group (9.6% vs. 2.3%) yielding an odds ratio [OR] of 4.57 (95%-CI 2.17-9.65). Compared to patients undergoing SAVR, patients with TAVI were older, more likely to be in NYHA class III and IV, and had a considerably higher logistic EuroSCORE and more comorbid conditions. Adjusted OR depended on the method used to control for confounding and ranged from 0.60 (0.11-3.36) to 7.57 (0.91-63.0). We examined the distribution of propensity scores and found scores to overlap sufficiently only in a narrow range. In patients with sufficient overlap of propensity scores, adjusted OR ranged from 0.35 (0.04-2.72) to 3.17 (0.31 to 31.9). In patients with insufficient overlap, we consistently found increased odds of death associated with TAVI compared with SAVR irrespective of the method used to control confounding, with adjusted OR ranging from 5.88 (0.67-51.8) to 25.7 (0.88-750). Approximately one third of patients undergoing TAVI were found to be potentially eligible for a randomised comparison of TAVI versus SAVR. CONCLUSIONS: Both measured and unmeasured confounding limit the conclusions that can be drawn from observational comparisons of TAVI versus SAVR. Our study indicates that TAVI could be associated with either substantial benefits or harms. Randomised comparisons of TAVI versus SAVR are warranted.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: To determine the clinical performance of a laser fluorescence device (DIAGNOdent pen, KaVo) to discriminate between different occlusal caries depths (D(0)-D(1-4); D(0-2)-D(3,4)) in permanent molars. METHODS: In this prospective, randomized two-centre-study 120 sound/uncavitated carious sites in 120 patients were measured after visual and radiographic caries assessment. In cases of operative intervention (n=86), the lesion depths after caries removal were recorded (reference). In cases of preventive intervention (n=34), the sites were reassessed visually/radiographically after 12 months to verify the status assessed before (reference). The discrimination performance was determined statistically (Mann-Whitney test, Spearman's rho coefficient, and areas under the receiver operating characteristic curves (AUCs)). Sensitivities (SE) and specificities (SP) were plotted as a function of the measured values and cut-off values for the mentioned thresholds suggested. RESULTS: Sound sites (n=13) had significantly minor fluorescence values than carious sites (n=107) (P<0.0001) as had sites with no/enamel caries (n=63) compared to dentinal caries (n=57). The AUCs for the same discriminations were 0.92 and 0.78 (P<0.001). For the D(0)-D(1-4) threshold, a cut-off at a value of 12 (SE: 0.88, SP: 0.85) and for the D(0-2)-D(3,4) threshold at 25 (SE: 0.67, SP: 0.79) can be suggested. A moderate positive correlation between the measurements and the caries depths was calculated (rho=+0.57, P=0.01). CONCLUSION: Within this study, the device's discrimination performance for different caries depths was moderate to very good and it may be recommended as adjunct tool in the diagnosis of occlusal caries.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVES: The incidence distribution of triage advice in the medical call centre Medi24 and the pattern of service utilisation were analysed with respect to two groups of callers with different insurance schemes. Individuals having contracted insurance of the Medi24 model could use the telephone consultation service of the medical call centre Medi24 (mainly part of the mandatory basic health insurance) voluntarily and free of charge whereas individuals holding an insurance policy of the Telmed model (special contract within the mandatory basic health insurance with a premium discount ranging from 8% to 12%) were obliged to have a telephone consultation before arranging an appointment with a medical doctor. METHODS: A cross-sectional study was carried out in the medical call centre Medi24 based on all triage datasets of the Medi24 and Telmed groups collected during the one year period from July 1st 2005 to June 30th 2006. The distribution of the six different urgency levels within the two groups and their respective pattern of service utilisation was determined. In a multivariable logistic regression model the Odds Ratio for every enquiry originating from the Telmed group versus those originating from the Medi24 group was calculated. RESULTS: During a one-year period 48 388 triage requests reached the medical call centre Medi24, 56% derived from the Telmed group and 44% from the Medi24 group. Within the Medi24 group more than 25% of the individuals received self-care advice, within the Telmed group, on the other hand, only about 18% received such advice. In contrast, 27% of the Telmed triage requests but only 18% of the Medi24 triage requests resulted in the advice to make a routine appointment with a medical doctor. The probability that an individual of the Telmed group obtained the advice to go to the accident and emergency department was lower than for an individual of the Medi24 group (OR 0.77, 95% CI 0.60-0.99). Likewise, the probability of self-care advice was decreased in regard to the Medi24 group (OR 0.80, 95% CI 0.75-0.85). However, regarding the advice to make a routine appointment with a medical doctor, the Telmed group was represented more frequently than the Medi24 group (OR 1.36, 95% CI 1.28-1.44). CONCLUSION: In respect of the triage advice, the Telmed group differed significantly from the Medi24 group within all urgency levels. The differences between the two groups in respect of the advice given were still less pronounced than expected against the background of their different contract conditions and the disparate temporal pattern of utilisation. We interprete this finding with the fact that appraising the urgency of health problems appropriately seems to be very difficult for the majority of people seeking advice.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In Switzerland around 30,000 patients suffer from chronic skin wounds. Appropriate topical wound care along with treatment of the causes of the wounds enables to heal a lot of these patients and to avoid secondary disease such as infections. Thereby, the final goal of wound care is stable reepithelisation. Based on experience with chronic leg ulcers mainly in our out-patient wound centre, we give a survey of the wound dressings we actually use and discuss their wound-phase adapted application. Furthermore, we address the two tissue engineering products reimbursed in Switzerland, Apligraf and EpiDex, as well as the biological matrix product Oasis. The crucial question, which treatment options will be offered in future to the wound patients by our health regulatory and insurance systems, is open to debate.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Pneumothoraces are a common injury pattern in emergency medicine. Rapid and safe identification can reduce morbidity and mortality. A new handheld, battery powered device, the Pneumoscan (CE 561036, PneumoSonics Inc., Cleveland, OH, USA), using micropower impulse radar (MIR) technology, has recently been introduced in Europe for the rapid and reliable detection of PTX. However, this technology has not yet been tested in trauma patients. This is the first quality control evaluation to report on emergency room performance of a new device used in the trauma setting. MATERIAL AND METHODS: This study was performed at a Level I trauma centre in Switzerland. All patients with thoracic trauma and undergoing chest X-ray and CT-scan were eligible for the study. Readings were performed before the chest X-ray and CT scan. The patients had eight lung fields tested (four on each side). All readings with the Pneumoscan were performed by two junior residents in our department who had previously received an instructional tutorial of 15min. The qualitative MIR results were blinded, and stored on the device. We then compared the results of the MIR to those of the clinical examination, chest X-ray and CT-scan. RESULTS: 50 patients were included, with a mean age of 46 (SD 17) years. Seven patients presented with PTX diagnosed by CT; six of these were detected by Pneumoscan, leading to an overall sensitivity of 85.7 (95% confidence interval 42.1-99.6)%. Only two of seven PTX were found during clinical examination and on chest X-ray (sensitivity 28.6 (95% CI 3.7-71.0)%). Of the remaining 43 of 50 patients without PTX, one false-positive PTX was found by the Pneumoscan, resulting in a specificity of 97.7 (95% CI 87.7-99.9)%. DISCUSSION: The Pneumoscan is an easy to use handheld technology with reliable results. In this series, the sensitivity to detect a PTX by the Pneumoscan was higher than by clinical examination and chest X-ray. Further studies with higher case numbers and a prospective study design are needed to confirm our findings.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Lifshitz spacetimes with the critical exponent z = 2 can be obtained by the dimensional reduction of Schrödinger spacetimes with the critical exponent z = 0. The latter spacetimes are asymptotically AdS solutions of AdS gravity coupled to an axion–dilaton system and can be uplifted to solutions of type IIB supergravity. This basic observation is used to perform holographic renormalization for four-dimensional asymptotically z = 2 locally Lifshitz spacetimes by the Scherk–Schwarz dimensional reduction of the corresponding problem of holographic renormalization for five-dimensional asymptotically locally AdS spacetimes coupled to an axion–dilaton system. We can thus define and characterize a four-dimensional asymptotically locally z = 2 Lifshitz spacetime in terms of five-dimensional AdS boundary data. In this setup the four-dimensional structure of the Fefferman–Graham expansion and the structure of the counterterm action, including the scale anomaly, will be discussed. We find that for asymptotically locally z = 2 Lifshitz spacetimes obtained in this way, there are two anomalies each with their own associated nonzero central charge. Both anomalies follow from the Scherk–Schwarz dimensional reduction of the five-dimensional conformal anomaly of AdS gravity coupled to an axion–dilaton system. Together, they make up an action that is of the Horava–Lifshitz type with a nonzero potential term for z = 2 conformal gravity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Basal dendrites receive the majority of synapses that contact neocortical pyramidal neurons, yet our knowledge of synaptic processing in these dendrites has been hampered by their inaccessibility for electrical recordings. A new approach to patch-clamp recordings enabled us to characterize the integrative properties of these cells. Despite the short physical length of rat basal dendrites, synaptic inputs were electrotonically remote from the soma (>30-fold excitatory postsynaptic potential (EPSP) attenuation) and back-propagating action potentials were significantly attenuated. Unitary EPSPs were location dependent, reaching large amplitudes distally (>8 mV), yet their somatic contribution was relatively location independent. Basal dendrites support sodium and NMDA spikes, but not calcium spikes, for 75% of their length. This suggests that basal dendrites, despite their proximity to the site of action potential initiation, do not form a single basal-somatic region but rather should be considered as a separate integrative compartment favoring two integration modes: subthreshold, location-independent summation versus local amplification of incoming spatiotemporally clustered information.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Calcium influx into the dendritic tufts of layer 5 neocortical pyramidal neurons modifies a number of important cellular mechanisms. It can trigger local synaptic plasticity and switch the firing properties from regular to burst firing. Due to methodological limitations, our knowledge about Ca2+ spikes in the dendritic tuft stems mostly from in vitro experiments. However, it has been speculated that regenerative Ca2+ events in the distal dendrites correlate with distinct behavioral states. Therefore it would be most desirable to be able to record these Ca2+ events in vivo, preferably in the behaving animal. Here, we present a novel approach for recording Ca2+ signals in the dendrites of populations of layer 5 pyramidal neurons in vivo, which ensures that all recorded fluorescence changes are due to intracellular Ca2+ signals in the apical dendrites. The method has two main features: 1) bolus loading of layer 5 with a membrane-permeant Ca2+ dye resulting in specific loading of pyramidal cell dendrites in the upper layers and 2) a fiberoptic cable attached to a gradient index lens and a prism reflecting light horizontally at 90 degrees to the angle of the apical dendrites. We demonstrate that the in vivo signal-to-noise ratio recorded with this relatively inexpensive and easy-to-implement fiberoptic-based device is comparable to conventional camera-based imaging systems used in vitro. In addition, the device is flexible and lightweight and can be used for recording Ca2+ signals in the distal dendritic tuft of freely behaving animals.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Reports on left-lateralized abnormalities of component P300 of event-related brain potentials (ERP) in schizophrenics typically did not vary task difficulties. We collected 16-channel ERP in 13 chronic, medicated schizophrenics (25±4.9 years) and 13 matched controls in a visual P300 paradigm with targets defined by one or two stimulus dimensions (C1: color; C2: color and tilt); subjects key-pressed to targets. The mean target-ERP map landscapes were assessed numerically by the locations of the positive and negative map-area centroids. The centroids' time-space trajectories were searched for the P300 microstate landscape defined by the positive centroid posterior of the negative centroid. At P300 microstate centre latencies in C1, patients' maps tended to a right shift of the positive centroid (p<0.10); in C2 the anterior centroid was more posterior (p<0.07) and the posterior (positive) centroid more anterior (p<0.03), but without leftright difference. Duration of P300 microstate in C2 was shorter in patients (232 vs 347 ms;p<0.03) and the latency of maximal strength of P300 microstate increased significantly in patients (C1: 459 vs 376 ms; C2: 585 vs 525 ms). In summary only the one-dimensional task C1 supported left-sided abnormalities; the two-dimensional task C2 produced abnormal P300 microstate map landscapes in schizophrenics, but no abnormal lateralization. Thus, information processing involved clearly aberrant neural populations in schizophrenics, different when processing one and two stimulus dimensions. The lack of lateralization in the two-dimensional task supported the view that left-temporal abnormality in schizophrenics is only one of several task-dependent aberrations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Intraoperatively fabricated polymethylmethacrylate (PMMA) implants based on computer-designed moulds were used to improve cosmetic results after hard tissue replacement. To assess the implant's cosmetic and functional results we performed both subjective and objective assessments. METHODS This retrospective analysis was performed using a cohort of 28 patients who received PMMA implants between February 2009 and March 2012. The cosmetic and functional results were assessed using a patient questionnaire. Furthermore an objective volumetric subtraction score (0-100) was applied and implant thickness, as well as gaps and tiers, were measured. RESULTS Patients mainly judged their cosmetic result as "good". Two of the 28 patients found their cosmetic result unfavourable. The functional result and stability was mainly judged to be good. Measurements of implant thickness showed a very high correlation with the thickness of the contralateral bone. Volumetric subtraction led to a median quality of 80 on a scale from 0 to 100. Median gaps around the margins of the implant were 1.5 mm parietally, 1.7 mm frontally and 3.5 mm fronto-orbitally, and median tiers were 1.2 mm, 0 mm and 0 mm respectively. The overall rate of surgical revisions was 10.7 % (three patients). Two patients suffered from wound healing disturbances (7.1 %). The overall complication rate was comparable to other reports in the literature. CONCLUSIONS Implantation of intraoperatively fabricated patient-specific moulded implants is a cost-effective and safe technique leading to good clinical results with a low complication rate.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

During a two-year study, all spider bites recorded by Swiss primary care physicians were reported to the Swiss Toxicological Information Centre and all collected spiders were identified. A total of 14 verified spider bites were recorded, involving five species from four families: Zoropsis spinimana (five cases), Cheiracanthium punctorium (four cases), Tegenaria atrica (three cases) and one case of Malthonica ferruginea (¼ Tegenaria ferruginea) (both Agelenidae), and one case of Amaurobius ferox (Amaurobiidae). The bites of all spider species produced relatively mild symptoms. Local symptoms such as moderate to severe pain, circumscribed swelling and redness were the only effects in most cases. Systemic symptoms were rare. There was complete recovery in all cases and all lesions healed completely without further damage or secondary disorders. Following a review of the European spider bite literature, the number of spider species capable of biting humans in Europe is considered to be much larger than could be concluded from this study. Most spider bites are restricted to species living synanthropically, thus promoted by climate and habitat change. The annual frequency of spider bites in Switzerland is estimated at 10 – 100 bites per million inhabitants, but this is predicted to increase due to the continuous arrival of new alien species, many of which have a high potential to establish in urban areas

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Individual Video Training iVT and Annotating Academic Videos AAV: two complementing technologies 1. Recording communication skills training sessions and reviewing them by oneself, with peers, and with tutors has become standard in medical education. Increasing numbers of students paired with restrictions of financial and human resources create a big obstacle to this important teaching method. 2. Everybody who wants to increase efficiency and effectiveness of communication training can get new ideas from our technical solution. 3. Our goal was to increase the effectiveness of communication skills training by supporting self, peer and tutor assessment over the Internet. Two technologies of SWITCH, the national foundation to support IT solutions for Swiss universities, came handy for our project. The first is the authentication and authorization infrastructure providing all Swiss students with a nationwide single login. The second is SWITCHcast which allows automated recording, upload and publication of videos in the Internet. Students start the recording system by entering their single login. This automatically links the video with their password. Within a few hours, they find their video password protected on the Internet. They now can give access to peers and tutors. Additionally, an annotation interface was developed. This software has free text as well as checklist annotations capabilities. Tutors as well as students can create checklists. Tutor’s checklists are not editable by students. Annotations are linked to tracks. Tracks can be private or public. Public means visible to all who have access to the video. Annotation data can be exported for statistical evaluation. 4. The system was well received by students and tutors. Big numbers of videos were processed simultaneously without any problems. 5. iVT http://www.switch.ch/aaa/projects/detail/UNIBE.7 AAV http://www.switch.ch/aaa/projects/detail/ETHZ.9