48 resultados para software testing methods

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

While it is generally agreed that perception can occur without awareness, there continues to be debate about the type of representational content that is accessible when awareness is minimized or eliminated. Most investigations that have addressed this issue evaluate access to well-learned representations. Far fewer studies have evaluated whether or not associations encountered just once prior to testing might also be accessed and influence behavior. Here, eye movements were used to examine whether or not memory for studied relationships is evident following the presentation of subliminal cues. Participants (assigned to experimental or control groups) studied scene-face pairs and test trials evaluated implicit and explicit memory for these pairs. Each test trial began with a subliminal scene cue, followed by three visible studied faces. For experimental group participants, one face was the studied associate of the scene (implicit test); for controls none were a match. Subsequently, the Display containing a match was presented to both groups, but now it was preceded by a visible scene cue (explicit test). Eye movements were recorded and recognition Memory responses were made. Participants in the experimental group looked disproportionately at matching faces on implicit test trials and participants from both groups looked disproportionately at matching faces on explicit test trials, even when that face had not been successfully identified as the associate. Critically, implicit memory-based viewing effects seemed not to depend on residual awareness of subliminal scenes cues, as subjective and objective measures indicated that scenes were successfully masked from view. The reported outcomes indicate that memory for studied relationships can be expressed in eye movement behavior without awareness.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper describes the open source framework MARVIN for rapid application development in the field of biomedical and clinical research. MARVIN applications consist of modules that can be plugged together in order to provide the functionality required for a specific experimental scenario. Application modules work on a common patient database that is used to store and organize medical data as well as derived data. MARVIN provides a flexible input/output system with support for many file formats including DICOM, various 2D image formats and surface mesh data. Furthermore, it implements an advanced visualization system and interfaces to a wide range of 3D tracking hardware. Since it uses only highly portable libraries, MARVIN applications run on Unix/Linux, Mac OS X and Microsoft Windows.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJECTIVE: The presence of minority nonnucleoside reverse transcriptase inhibitor (NNRTI)-resistant HIV-1 variants prior to antiretroviral therapy (ART) has been linked to virologic failure in treatment-naive patients. DESIGN: We performed a large retrospective study to determine the number of treatment failures that could have been prevented by implementing minority drug-resistant HIV-1 variant analyses in ART-naïve patients in whom no NNRTI resistance mutations were detected by routine resistance testing. METHODS: Of 1608 patients in the Swiss HIV Cohort Study, who have initiated first-line ART with two nucleoside reverse transcriptase inhibitors (NRTIs) and one NNRTI before July 2008, 519 patients were eligible by means of HIV-1 subtype, viral load and sample availability. Key NNRTI drug resistance mutations K103N and Y181C were measured by allele-specific PCR in 208 of 519 randomly chosen patients. RESULTS: Minority K103N and Y181C drug resistance mutations were detected in five out of 190 (2.6%) and 10 out of 201 (5%) patients, respectively. Focusing on 183 patients for whom virologic success or failure could be examined, virologic failure occurred in seven out of 183 (3.8%) patients; minority K103N and/or Y181C variants were present prior to ART initiation in only two of those patients. The NNRTI-containing, first-line ART was effective in 10 patients with preexisting minority NNRTI-resistant HIV-1 variant. CONCLUSION: As revealed in settings of case-control studies, minority NNRTI-resistant HIV-1 variants can have an impact on ART. However, the sole implementation of minority NNRTI-resistant HIV-1 variant analysis in addition to genotypic resistance testing (GRT) cannot be recommended in routine clinical settings. Additional associated risk factors need to be discovered.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND Lung clearance index (LCI), a marker of ventilation inhomogeneity, is elevated early in children with cystic fibrosis (CF). However, in infants with CF, LCI values are found to be normal, although structural lung abnormalities are often detectable. We hypothesized that this discrepancy is due to inadequate algorithms of the available software package. AIM Our aim was to challenge the validity of these software algorithms. METHODS We compared multiple breath washout (MBW) results of current software algorithms (automatic modus) to refined algorithms (manual modus) in 17 asymptomatic infants with CF, and 24 matched healthy term-born infants. The main difference between these two analysis methods lies in the calculation of the molar mass differences that the system uses to define the completion of the measurement. RESULTS In infants with CF the refined manual modus revealed clearly elevated LCI above 9 in 8 out of 35 measurements (23%), all showing LCI values below 8.3 using the automatic modus (paired t-test comparing the means, P < 0.001). Healthy infants showed normal LCI values using both analysis methods (n = 47, paired t-test, P = 0.79). The most relevant reason for false normal LCI values in infants with CF using the automatic modus was the incorrect recognition of the end-of-test too early during the washout. CONCLUSION We recommend the use of the manual modus for the analysis of MBW outcomes in infants in order to obtain more accurate results. This will allow appropriate use of infant lung function results for clinical and scientific purposes.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVES Multiple-breath washout (MBW) is an attractive test to assess ventilation inhomogeneity, a marker of peripheral lung disease. Standardization of MBW is hampered as little data exists on possible measurement bias. We aimed to identify potential sources of measurement bias based on MBW software settings. METHODS We used unprocessed data from nitrogen (N2) MBW (Exhalyzer D, Eco Medics AG) applied in 30 children aged 5-18 years: 10 with CF, 10 formerly preterm, and 10 healthy controls. This setup calculates the tracer gas N2 mainly from measured O2 and CO2concentrations. The following software settings for MBW signal processing were changed by at least 5 units or >10% in both directions or completely switched off: (i) environmental conditions, (ii) apparatus dead space, (iii) O2 and CO2 signal correction, and (iv) signal alignment (delay time). Primary outcome was the change in lung clearance index (LCI) compared to LCI calculated with the settings as recommended. A change in LCI exceeding 10% was considered relevant. RESULTS Changes in both environmental and dead space settings resulted in uniform but modest LCI changes and exceeded >10% in only two measurements. Changes in signal alignment and O2 signal correction had the most relevant impact on LCI. Decrease of O2 delay time by 40 ms (7%) lead to a mean LCI increase of 12%, with >10% LCI change in 60% of the children. Increase of O2 delay time by 40 ms resulted in mean LCI decrease of 9% with LCI changing >10% in 43% of the children. CONCLUSIONS Accurate LCI results depend crucially on signal processing settings in MBW software. Especially correct signal delay times are possible sources of incorrect LCI measurements. Algorithms of signal processing and signal alignment should thus be optimized to avoid susceptibility of MBW measurements to this significant measurement bias.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Concern over possible adverse effects of endocrine-disrupting compounds on fish has caused the development of appropriate testing methods. In vitro screening assays may provide initial information on endocrine activities of a test compound and thereby may direct and optimize subsequent testing. Induction of vitellogenin (VTG) is used as a biomarker of exposure of fish to estrogen-active substances. Since VTG induction can be measured not only in vivo but also in fish hepatocytes in vitro, the use of VTG induction response in isolated fish liver cells has been suggested as in vitro screen for identifying estrogenic-active substances. The main advantages of the hepatocyte VTG assay are considered its ability to detect effects of estrogenic metabolites, since hepatocytes in vitro remain metabolically competent, and its ability to detect both estrogenic and anti-estrogenic effects. In this article, we critically review the current knowledge on the VTG response of cultured fish hepatocytes to (anti)estrogenic substances. In particular, we discuss the sensitivity, specificity, and variability of the VTG hepatocyte assay. In addition, we review the available data on culture factors influencing basal and induced VTG production, the response to natural and synthetic estrogens as well as to xenoestrogens, the detection of indirect estrogens, and the sources of assay variability. The VTG induction in cultured fish hepatocytes is clearly influenced by culture conditions (medium composition, temperature, etc.) and culture system (hepatocyte monolayers, aggregates, liver slices, etc.). The currently available database on estrogen-mediated VTG induction in cultured teleost hepatocytes is too small to support conclusive statements on whether there exist systematic differences of the VTG response between in vitro culture systems, VTG analytical methods or fish species. The VTG hepatocyte assay detects sensitively natural and synthetic estrogens, whereas the response to xenoestrogens appears to be more variable. The detection of weak estrogens can be critical due to the overshadow with cytotoxic concentrations. Moreover, the VTG hepatocyte assay is able to detect antiestrogens as well as indirect estrogens, i.e substances which require metabolic activation to induce an estrogenic response. Nevertheless, more chemicals need to be analysed to corroborate this statement. It will be necessary to establish standardized protocols to minimize assay variability, and to develop a set of pass-fail criteria as well as cut-offs for designating positive and negative responses.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Calcitonin was effective in a study of acute phantom limb pain, but it was not studied in the chronic phase. The overall literature on N-methyl-D-aspartate antagonists is equivocal. We tested the hypothesis that calcitonin, ketamine, and their combination are effective in treating chronic phantom limb pain. Our secondary aim was to improve our understanding of the mechanisms of action of the investigated drugs using quantitative sensory testing. METHODS: Twenty patients received, in a randomized, double-blind, crossover manner, 4 i.v. infusions of: 200 IE calcitonin; ketamine 0.4 mg/kg (only 10 patients); 200 IE of calcitonin combined with ketamine 0.4 mg/kg; placebo, 0.9% saline. Intensity of phantom pain (visual analog scale) was recorded before, during, at the end, and the 48 h after each infusion. Pain thresholds after electrical, thermal, and pressure stimulation were recorded before and during each infusion. RESULTS: Ketamine, but not calcitonin, reduced phantom limb pain. The combination was not superior to ketamine alone. There was no difference in basal pain thresholds between the amputated and contralateral side except for pressure pain. Pain thresholds were unaffected by calcitonin. The analgesic effect of the combination of calcitonin and ketamine was associated with a significant increase in electrical thresholds, but with no change in pressure and heat thresholds. CONCLUSIONS: Our results question the usefulness of calcitonin in chronic phantom limb pain and stress the potential interest of N-methyl-D-aspartate antagonists. Sensory assessments indicated that peripheral mechanisms are unlikely important determinants of phantom limb pain. Ketamine, but not calcitonin, affects central sensitization processes that are probably involved in the pathophysiology of phantom limb pain.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND HIV-1 RNA viral load (VL) testing is recommended to monitor antiretroviral therapy (ART) but not available in many resource-limited settings. We developed and validated CD4-based risk charts to guide targeted VL testing. METHODS We modeled the probability of virologic failure up to 5 years of ART based on current and baseline CD4 counts, developed decision rules for targeted VL testing of 10%, 20% or 40% of patients in seven cohorts of patients starting ART in South Africa, and plotted cut-offs for VL testing on colour-coded risk charts. We assessed the accuracy of risk chart-guided VL testing to detect virologic failure in validation cohorts from South Africa, Zambia and the Asia-Pacific. FINDINGS 31,450 adult patients were included in the derivation and 25,294 patients in the validation cohorts. Positive predictive values increased with the percentage of patients tested: from 79% (10% tested) to 98% (40% tested) in the South African, from 64% to 93% in the Zambian and from 73% to 96% in the Asia-Pacific cohorts. Corresponding increases in sensitivity were from 35% to 68% in South Africa, from 55% to 82% in Zambia and from 37% to 71% in Asia-Pacific. The area under the receiver-operating curve increased from 0.75 to 0.91 in South Africa, from 0.76 to 0.91 in Zambia and from 0.77 to 0.92 in Asia Pacific. INTERPRETATION CD4-based risk charts with optimal cut-offs for targeted VL testing may be useful to monitor ART in settings where VL capacity is limited.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND HIV-1 RNA viral load (VL) testing is recommended to monitor antiretroviral therapy (ART) but not available in many resource-limited settings. We developed and validated CD4-based risk charts to guide targeted VL testing. METHODS We modeled the probability of virologic failure up to 5 years of ART based on current and baseline CD4 counts, developed decision rules for targeted VL testing of 10%, 20%, or 40% of patients in 7 cohorts of patients starting ART in South Africa, and plotted cutoffs for VL testing on colour-coded risk charts. We assessed the accuracy of risk chart-guided VL testing to detect virologic failure in validation cohorts from South Africa, Zambia, and the Asia-Pacific. RESULTS In total, 31,450 adult patients were included in the derivation and 25,294 patients in the validation cohorts. Positive predictive values increased with the percentage of patients tested: from 79% (10% tested) to 98% (40% tested) in the South African cohort, from 64% to 93% in the Zambian cohort, and from 73% to 96% in the Asia-Pacific cohort. Corresponding increases in sensitivity were from 35% to 68% in South Africa, from 55% to 82% in Zambia, and from 37% to 71% in Asia-Pacific. The area under the receiver operating curve increased from 0.75 to 0.91 in South Africa, from 0.76 to 0.91 in Zambia, and from 0.77 to 0.92 in Asia-Pacific. CONCLUSIONS CD4-based risk charts with optimal cutoffs for targeted VL testing maybe useful to monitor ART in settings where VL capacity is limited.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND AND AIMS Combined multichannel intraluminal impedance and esophageal manometry (MII-EM) measures concomitantly bolus transit and pressure changes allowing determination of the functional impact of esophageal motility abnormalities. Ten years ago our laboratory reported MII-EM results in 350 consecutive patients. Since then high-resolution impedance manometry (HRIM) became available and the definitions of ineffective esophageal motility (IEM) and nutcracker esophagus were revised. The aim of this study was to assess the impact of these developments on esophageal function testing. METHODS From August 2012 through May 2013, HRIM was performed in 350 patients referred for esophageal function testing. Each patient received 10 liquid and 10 viscous swallows. While taking advantage of the new technology and revised criteria, HRIM findings were classified according to the conventional criteria to allow more appropriate comparison with our earlier analysis. RESULTS Compared with the study performed 10 years ago, the prevalence of normal manometry (36% vs. 35%), achalasia (7% vs. 8%), scleroderma (1% vs. 1%), hypertensive lower esophageal sphincter (LES) (7% vs. 7%), and hypotensive LES (1% vs. 2%) remained the same, whereas the prevalence of distal esophageal spasm (9% vs. 3%), nutcracker esophagus (9% vs. 3%), and poorly relaxing LES (10% vs. 3%) decreased and the prevalence of IEM increased (20% vs. 31%) significantly. Compared with the early study, normal liquid bolus transit was significantly different in patients with hypertensive LES (96% vs. 57%) and poorly relaxing LES (55% vs. 100%). CONCLUSIONS This study brings to light the increase in prevalence of IEM. In addition, it suggests that the hypertensive LES and poorly relaxing LES may each affect bolus transit in about half of these patients.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVES Chewing efficiency may be evaluated using cohesive specimen, especially in elderly or dysphagic patients. The aim of this study was to evaluate three two-coloured chewing gums for a colour-mixing ability test and to validate a new purpose built software (ViewGum©). METHODS Dentate participants (dentate-group) and edentulous patients with mandibular two-implant overdentures (IOD-group) were recruited. First, the dentate-group chewed three different types of two-coloured gum (gum1-gum3) for 5, 10, 20, 30 and 50 chewing cycles. Subsequently the number of chewing cycles with the highest intra- and inter-rater agreement was determined visually by applying a scale (SA) and opto-electronically (ViewGum©, Bland-Altman analysis). The ViewGum© software determines semi-automatically the variance of hue (VOH); inadequate mixing presents with larger VOH than complete mixing. Secondly, the dentate-group and the IOD-group were compared. RESULTS The dentate-group comprised 20 participants (10 female, 30.3±6.7 years); the IOD-group 15 participants (10 female, 74.6±8.3 years). Intra-rater and inter-rater agreement (SA) was very high at 20 chewing cycles (95.00-98.75%). Gums 1-3 showed different colour-mixing characteristics as a function of chewing cycles, gum1 showed a logarithmic association; gum2 and gum3 demonstrated more linear behaviours. However, the number of chewing cycles could be predicted in all specimens from VOH (all p<0.0001, mixed linear regression models). Both analyses proved discriminative to the dental state. CONCLUSION ViewGum© proved to be a reliable and discriminative tool to opto-electronically assess chewing efficiency, given an elastic specimen is chewed for 20 cycles and could be recommended for the evaluation of chewing efficiency in a clinical and research setting. CLINICAL SIGNIFICANCE Chewing is a complex function of the oro-facial structures and the central nervous system. The application of the proposed assessments of the chewing function in geriatrics or special care dentistry could help visualising oro-functional or dental comorbidities in dysphagic patients or those suffering from protein-energy malnutrition.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND The cost-effectiveness of routine viral load (VL) monitoring of HIV-infected patients on antiretroviral therapy (ART) depends on various factors that differ between settings and across time. Low-cost point-of-care (POC) tests for VL are in development and may make routine VL monitoring affordable in resource-limited settings. We developed a software tool to study the cost-effectiveness of switching to second-line ART with different monitoring strategies, and focused on POC-VL monitoring. METHODS We used a mathematical model to simulate cohorts of patients from start of ART until death. We modeled 13 strategies (no 2nd-line, clinical, CD4 (with or without targeted VL), POC-VL, and laboratory-based VL monitoring, with different frequencies). We included a scenario with identical failure rates across strategies, and one in which routine VL monitoring reduces the risk of failure. We compared lifetime costs and averted disability-adjusted life-years (DALYs). We calculated incremental cost-effectiveness ratios (ICER). We developed an Excel tool to update the results of the model for varying unit costs and cohort characteristics, and conducted several sensitivity analyses varying the input costs. RESULTS Introducing 2nd-line ART had an ICER of US$1651-1766/DALY averted. Compared with clinical monitoring, the ICER of CD4 monitoring was US$1896-US$5488/DALY averted and VL monitoring US$951-US$5813/DALY averted. We found no difference between POC- and laboratory-based VL monitoring, except for the highest measurement frequency (every 6 months), where laboratory-based testing was more effective. Targeted VL monitoring was on the cost-effectiveness frontier only if the difference between 1st- and 2nd-line costs remained large, and if we assumed that routine VL monitoring does not prevent failure. CONCLUSION Compared with the less expensive strategies, the cost-effectiveness of routine VL monitoring essentially depends on the cost of 2nd-line ART. Our Excel tool is useful for determining optimal monitoring strategies for specific settings, with specific sex-and age-distributions and unit costs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background Primary care is an important provider of sexual health care in England. We sought to explore the extent of testing for chlamydia and HIV in general practice and its relation to associated measures of sexual health in two contrasting geographical settings. Methods We analysed chlamydia and HIV testing data from 64 general practices and one genitourinary medicine (GUM) clinic in Brent (from mid-2003 to mid-2006) and 143 general practices and two GUM clinics in Avon (2004). We examined associations between practice testing status, practice characteristics and hypothesised markers of population need (area level teenage conception rates and Index of Multiple Deprivation, IMD scores). Results No HIV or chlamydia testing was done in 19% (12/64) of general practices in Brent, compared to 2.1% (3/143) in Avon. In Brent, the mean age of general practitioners (GPs) in Brent practices that tested for chlamydia or HIV was lower than in those that had not conducted testing. Practices where no HIV testing was done had slightly higher local teenage conception rates (median 23.5 vs. 17.4/1000 women aged 15-44, p = 0.07) and served more deprived areas (median IMD score 27.1 vs. 21.8, p = 0.05). Mean yearly chlamydia and HIV testing rates, in practices that did test were 33.2 and 0.6 (per 1000 patients aged 15-44 years) in Brent, and 34.1 and 10.3 in Avon, respectively. In Brent practices only 20% of chlamydia tests were conducted in patients aged under 25 years, compared with 39% in Avon. Conclusions There are substantial geographical differences in the intensity of chlamydia and HIV testing in general practice. Interventions to facilitate sexually transmitted infection and HIV testing in general practice are needed to improve access to effective sexual health care. The use of routinely-collected laboratory, practice-level and demographic data for monitoring sexual health service provision and informing service planning should be more widely evaluated.