47 resultados para renal vascular access

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

GOAL We present the development of a boneanchored port for the painless long-term hemodialytic treatment of patients with renal failure. This port is implanted behind the ear. METHODS The port was developed based on knowledge obtained from long-term experience with implantable hearing devices, which are firmly anchored to the bone behind the ear. This concept of bone anchoring was adapted to the requirements for a vascular access during hemodialysis. The investigational device is comprised of a base plate that is firmly fixed with bone screws to the bone behind the ear (temporal bone). A catheter leads from the base plate valve block through the internal jugular vein and into the right atrium. The valves are opened using a special disposable adapter, without any need to puncture the blood vessels. Between hemodialysis sessions the port is protected with a disposable cover. RESULTS Flow rate, leak tightness and purification were tested on mockups. Preoperative planning and the surgical procedure were verified in 15 anatomical human whole head specimens. CONCLUSION Preclinical evaluations demonstrated the technical feasibility and safety of the investigational device. SIGNIFICANCE Approximately 1.5 million people are treated with hemodialysis worldwide, and 25% of the overall cost of dialysis therapy results from vascular access problems. New approaches towards enhancing vascular access could potentially reduce the costs and complications of hemodialytic therapy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Integrins are matrix receptors that regulate cell-matrix interactions during development and in adult tissue. In the adult kidney, the alpha8 chain is specifically expressed in glomerular mesangial cells and vascular smooth muscle cells. alpha8-deficient (alpha8-/-) mice demonstrate reductions in renal mass, which can range from complete renal agenesis to the development of kidneys that are only slightly smaller than wild-type kidneys. No histologic abnormalities of these kidneys have been described. However, considering the prominent expression of alpha8 in glomeruli and renal vessels, it seemed unlikely that the kidneys of alpha8-/- mice would be completely normal. Therefore, the renal phenotype of adult alpha8-/- mice was investigated, for assessment of more subtle morphologic alterations in kidney tissue. alpha8-/- mice displayed a significant reduction in nephron number and an increase in glomerular volume, compared with wild-type control animals. Albuminuria was not different in wild-type and alpha8-/- mice. Quantitative morphologic analyses revealed that the glomeruli of alpha8-/- mice were hypercellular, with an increased number of mesangial cells, compared with wild-type mice. Mesangial matrix deposition (as demonstrated for collagen IV and the alpha8 ligand fibronectin) was expanded in alpha8-/- mice, compared with wild-type mice. Collagens I and III, which are not normally present in glomeruli, were detected in the glomeruli of alpha8-/- mice. Staining for other glomerular integrins demonstrated an increased abundance of the collagen receptor alpha2 integrin in alpha8-/- mice. The glomerular capillary length density was significantly greater in alpha8-/- mice than in wild-type mice. Cortical arterial vessel walls were not altered in alpha8-/- mice, but the capillaries of the peritubular network were widened. Despite the strong mesangial and vascular expression of alpha8, glomerular and renal vascular alterations in alpha8-/- mice were relatively mild. Only aged alpha8-/- mice demonstrated increased glomerular capillary widening, compared with control animals. The results suggest that the lack of alpha8 can be largely compensated for, at least in younger alpha8-/- mice. It is not yet clear whether the occurrence of collagens that are not normally present in glomeruli and the increased abundance of the collagen receptor alpha2 contribute to maintaining the glomerular structure in alpha8-/- mice. The compensatory mechanisms involved will be the subject of future research.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the last years, simulation training has become widespread in different areas of medicine due to social expectations, political accountability and professional regulation. Different types of simulators allow to improve knowledge, skills, communication and team behavior. Simulation sessions have been proven to shorten the learning curve and allow education in a safe environment. Patients on dialysis are an expanding group. They often suffer from several comorbidities and need complex surgical procedures with regard to their dialysis access. Therefore, education in evidence-based algorithms is as important as teaching of practical skills. In this chapter, we are presenting an overview of available dialysis access training modalities. We are convinced that simulation will become more important in the near future and has a substantial impact on strategies to improve aspects of patient safety. © 2015 S. Karger AG, Basel.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Morbidity and mortality are significant in hemodialysis patients, and every vascular access (VA) is prone to complications - some more, some less. The risk of complications rises from arteriovenous fistulae to arteriovenous grafts and peaks in nontunneled central lines. Strategies to achieve complete evaluation of the patient and precise planning mark the start of successful VA creation. Furthermore, preoperative considerations include safety checklists, team time-out procedures, and antibiotic prophylaxis. Intraoperative technical features and postoperative aspects of documentation and surveillance schemes complete careful and safe VA creation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Rapidly growing technical developments and working time constraints call for changes in trainee formation. In reality, trainees spend fewer hours in the hospital and face more difficulties in acquiring the required qualifications in order to work independently as a specialist. Simulation-based training is a potential solution. It offers the possibility to learn basic technical skills, repeatedly perform key steps in procedures and simulate challenging scenarios in team training. Patients are not at risk and learning curves can be shortened. Advanced learners are able to train rare complications. Senior faculty member's presence is key to assess and debrief effective simulation training. In the field of vascular access surgery, simulation models are available for open as well as endovascular procedures. In this narrative review, we describe the theory of simulation, present simulation models in vascular (access) surgery, discuss the possible benefits for patient safety and the difficulties of implementing simulation in training.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nosocomial infections in patients requiring renal replacement therapy have a high impact on morbidity and mortality. The most dangerous complication is bloodstream infection (BSI) associated with the vascular access, with a low BSI risk in arteriovenous fistulas or grafts and a comparatively high risk in central venous catheters. The single most important measure for preventing BSI is therefore the reduction of catheter use by means of early fistula formation. As this is not always feasible, prevention should focus on educational efforts, hand hygiene, surveillance of dialysis-associated events, and specific measures at and after the insertion of catheters. Core measures at the time of insertion include choosing the optimal site of insertion, the use of maximum sterile barrier precautions, adequate skin antisepsis, and the choice of catheter type; after insertion, access care needs to ensure hub disinfection and regular dressing changes. The application of antimicrobial locks is reserved for special situations. Evidence suggests that bundling a selection of the aforementioned measures can significantly reduce infection rates. The diagnosis of central line-associated BSI (CLABSI) is based on clinical signs and microbiological findings in blood cultures ideally drawn both peripherally and from the catheter. The prompt installation of empiric antibiotic treatment covering the most commonly encountered organisms is key regarding CLABSI treatment. Catheter removal is recommended in complicated cases or if cultures yield Staphylococcus aureus, enterococci, Pseudomonas or fungi. In other cases, guide wire exchange or catheter salvage strategies with antibiotic lock solutions may be acceptable alternatives.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Vascular access patency is of vital importance for patients requiring haemodialysis. This analysis validates potential risk factors and benefits in patients undergoing vascular access procedures.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

PURPOSE: This study aimed to evaluate the safety and patency rate of bovine mesenterial vein grafts (BMVG) for vascular access (VA) in hemodialysis patients (HDP), compared to expanded polytetrafluorethylene (ePTFE grafts) over a mid- to long-term period. METHODS: Patency and complication rate of 23 consecutive HDP with BMVG for VA were compared to a control group consisting of 23 similar HDP with ePTFE grafts. In both groups, the graft was placed preferably in a forearm loop configuration. The same surgeon performed all procedures. All patients were followed over a period of 4 yrs. RESULTS: Graft placement was successful in all patients. Patency rates did not differ significantly in both groups. However, there were less severe complications in the BMVG group. CONCLUSION: The BMVG is a viable alternative for HD access in patients where autologous construction is not possible, and should be given priority in patients with a failed ePTFE graft or high risk for infection.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND: Transcatheter aortic valve implantation (TAVI) for high-risk and inoperable patients with severe aortic stenosis is an emerging procedure in cardiovascular medicine. Little is known of the impact of TAVI on renal function. METHODS: We analysed retrospectively renal baseline characteristics and outcome in 58 patients including 2 patients on chronic haemodialysis undergoing TAVI at our institution. Acute kidney injury (AKI) was defined according to the RIFLE classification. RESULTS: Fifty-eight patients with severe symptomatic aortic stenosis not considered suitable for conventional surgical valve replacement with a mean age of 83 +/- 5 years underwent TAVI. Two patients died during transfemoral valve implantation and two patients in the first month after TAVI resulting in a 30-day mortality of 6.9%. Vascular access was transfemoral in 46 patients and transapical in 12. Estimated glomerular filtration rate (eGFR) increased in 30 patients (56%). Fifteen patients (28%) developed AKI, of which four patients had to be dialyzed temporarily and one remained on chronic renal replacement therapy. Risk factors for AKI comprised, among others, transapical access, number of blood transfusions, postinterventional thrombocytopaenia and severe inflammatory response syndrome (SIRS). CONCLUSIONS: TAVI is feasible in patients with a high burden of comorbidities and in patients with pre-existing end-stage renal disease who would be otherwise not considered as candidates for conventional aortic valve replacement. Although GFR improved in more than half of the patients, this benefit was associated with a risk of postinterventional AKI. Future investigations should define preventive measures of peri-procedural kidney injury.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Renal replacement therapy by hemodialysis requires a permanent vascular access. Implantable ports offer a potential alternative to standard vascular access strategies although their development is limited both in number and extent. We explored the fluid dynamics within two new percutaneous bone-anchored dialysis port prototypes, both by in vitro experiments and computer simulation. The new port is to be fixed to bone and allows the connection of a dialysis machine to a central venous catheter via a built-in valve. We found that the pressure drop induced by the two ports was between 20 and 50 mmHg at 500 ml/min, which is comparable with commercial catheter connectors (15–80 mmHg). We observed the formation of vortices in both geometries, and a shear rate in the physiological range (<10,000s-1), which is lower than maximal shear rates reported in commercial catheters (up to 13,000s-1). A difference in surface shear rate of 15% between the two ports was obtained.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

For more than 15 years, patient safety has been an issue in different domains of medicine. There is evidence for this subject and also a great need for information. First, we should be familiar with the basic terminology such as the relationship between adverse events and errors, and understand the variations of error. In patient management, besides skills and knowledge (evidence-based medicine), the ability (competence) of healthcare professionals to act and react in unexpected situations is key to prevent and treat adverse events. Not only healthcare professionals should be involved in the process but also healthy people in a way that they understand and patients in a way that they are actively involved. This paper will show how a more general view of patient safety can and should be implemented in the daily work of caregivers dealing with dialysis access in different aspects. A key factor to advance in this subject is to be open-minded and sensualized for this topic. The reader should get an idea of how an institution can create a culture of safety.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Operating room (OR) team safety training and learning in the field of dialysis access is well suited for the use of simulators, simulated case learning and root cause analysis of adverse outcomes. The objectives of OR team training are to improve communication and leadership skills, to use checklists and to prevent errors. Other objectives are to promote a change in the attitudes towards vascular access from learning through mistakes in a nonpunitive environment, to positively impact the employee performance and to increase staff retention by making the workplace safer, more efficient and user friendly.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJECTIVE Renal resistive index (RRI) varies directly with renal vascular stiffness and pulse pressure. RRI correlates positively with arteriolosclerosis in damaged kidneys and predicts progressive renal dysfunction. Matrix Gla-protein (MGP) is a vascular calcification inhibitor that needs vitamin K to be activated. Inactive MGP, known as desphospho-uncarboxylated MGP (dp-ucMGP), can be measured in plasma and has been associated with various cardiovascular (CV) markers, CV outcomes and mortality. In this study we hypothesize that increased RRI is associated with high levels of dp-ucMGP. DESIGN AND METHOD We recruited participants via a multi-center family-based cross-sectional study in Switzerland exploring the role of genes and kidney hemodynamics in blood pressure regulation. Dp-ucMGP was quantified in plasma samples by sandwich ELISA. Renal doppler sonography was performed using a standardized protocol to measure RRIs on 3 segmental arteries in each kidney. The mean of the 6 measures was reported. Multiple regression analysis was performed to estimate associations between RRI and dp-ucMGP adjusting for sex, age, pulse pressure, mean pressure, renal function and other CV risk factors. RESULTS We included 1035 participants in our analyses. Mean values were 0.64 ± 0.06 for RRI and 0.44 ± 0.21 (nmol/L) for dp-ucMGP. RRI was positively associated with dp-ucMGP both before and after adjustment for sex, age, body mass index, pulse pressure, mean pressure, heart rate, renal function, low and high density lipoprotein, smoking status, diabetes, blood pressure and cholesterol lowering drugs, and history of CV disease (P < 0.001). CONCLUSIONS RRI is independently and positively associated with high levels of dp-ucMGP after adjustment for pulse pressure and common CV risk factors. Further studies are needed to determine if vitamin K supplementation can have a positive effect on renal vascular stiffness and kidney function.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Central venous catheters are established as vascular access in hemodialysis therapy. Vascular catheter misdirection may occur and is a well known problem. We present a rare catheter malposition in a young dialysis patient with consequent dilatation of the azygos vein system, simulating the appearance of an azygos continuation syndrome.