16 resultados para relative static method
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Software developers are often unsure of the exact name of the method they need to use to invoke the desired behavior in a given context. This results in a process of searching for the correct method name in documentation, which can be lengthy and distracting to the developer. We can decrease the method search time by enhancing the documentation of a class with the most frequently used methods. Usage frequency data for methods is gathered by analyzing other projects from the same ecosystem - written in the same language and sharing dependencies. We implemented a proof of concept of the approach for Pharo Smalltalk and Java. In Pharo Smalltalk, methods are commonly searched for using a code browser tool called "Nautilus", and in Java using a web browser displaying HTML based documentation - Javadoc. We developed plugins for both browsers and gathered method usage data from open source projects, in order to increase developer productivity by reducing method search time. A small initial evaluation has been conducted showing promising results in improving developer productivity.
Resumo:
Vertebroplasty and kyphoplasty are well-established minimally invasive treatment options for compression fractures of osteoporotic vertebral bodies. Possible procedural disadvantages, however, include incomplete fracture reduction or a significant loss of reduction after balloon tamp deflation, prior to cement injection. A new procedure called "vertebral body stenting" (VBS) was tested in vitro and compared to kyphoplasty. VBS uses a specially designed catheter-mounted stent which can be implanted and expanded inside the vertebral body. As much as 24 fresh frozen human cadaveric vertebral bodies (T11-L5) were utilized. After creating typical compression fractures, the vertebral bodies were reduced by kyphoplasty (n = 12) or by VBS (n = 12) and then stabilized with PMMA bone cement. Each step of the procedure was performed under fluoroscopic control and analysed quantitatively. Finally, static and dynamic biomechanical tests were performed. A complete initial reduction of the fractured vertebral body height was achieved by both systems. There was a significant loss of reduction after balloon deflation in kyphoplasty compared to VBS, and a significant total height gain by VBS (mean +/- SD in %, p < 0.05, demonstrated by: anterior height loss after deflation in relation to preoperative height [kyphoplasty: 11.7 +/- 6.2; VBS: 3.7 +/- 3.8], and total anterior height gain [kyphoplasty: 8.0 +/- 9.4; VBS: 13.3 +/- 7.6]). Biomechanical tests showed no significant stiffness and failure load differences between systems. VBS is an innovative technique which allows for the possibly complete reduction of vertebral compression fractures and helps maintain the restored height by means of a stent. The height loss after balloon deflation is significantly decreased by using VBS compared to kyphoplasty, thus offering a new promising option for vertebral augmentation.
Resumo:
BACKGROUND: Cystic fibrosis (CF) is associated with at least 1 pathogen point sequence variant on each CFTR allele. Some symptomatic patients, however, have only 1 detectable pathogen sequence variant and carry, on the other allele, a large deletion that is not detected by conventional screening methods. METHODS: For relative quantitative real-time PCR detection of large deletions in the CFTR gene, we designed DNA-specific primers for each exon of the gene and primers for a reference gene (beta2-microglobulin). For PCR we used a LightCycler system (Roche) and calculated the gene-dosage ratio of CFTR to beta2-microglobulin. We tested the method by screening all 27 exons in 3 healthy individuals and 2 patients with only 1 pathogen sequence variant. We then performed specific deletion screenings in 10 CF patients with known large deletions and a blinded analysis in which we screened 24 individuals for large deletions by testing 8 of 27 exons. RESULTS: None of the ratios for control samples were false positive (for deletions or duplications); moreover, for all samples from patients with known large deletions, the calculated ratios for deleted exons were close to 0.5. In addition, the results from the blinded analysis demonstrated that our method can also be used for the screening of single individuals. CONCLUSIONS: The LightCycler assay allows reliable and rapid screening for large deletions in the CFTR gene and detects the copy number of all 27 exons.
Resumo:
The penetration, translocation, and distribution of ultrafine and nanoparticles in tissues and cells are challenging issues in aerosol research. This article describes a set of novel quantitative microscopic methods for evaluating particle distributions within sectional images of tissues and cells by addressing the following questions: (1) is the observed distribution of particles between spatial compartments random? (2) Which compartments are preferentially targeted by particles? and (3) Does the observed particle distribution shift between different experimental groups? Each of these questions can be addressed by testing an appropriate null hypothesis. The methods all require observed particle distributions to be estimated by counting the number of particles associated with each defined compartment. For studying preferential labeling of compartments, the size of each of the compartments must also be estimated by counting the number of points of a randomly superimposed test grid that hit the different compartments. The latter provides information about the particle distribution that would be expected if the particles were randomly distributed, that is, the expected number of particles. From these data, we can calculate a relative deposition index (RDI) by dividing the observed number of particles by the expected number of particles. The RDI indicates whether the observed number of particles corresponds to that predicted solely by compartment size (for which RDI = 1). Within one group, the observed and expected particle distributions are compared by chi-squared analysis. The total chi-squared value indicates whether an observed distribution is random. If not, the partial chi-squared values help to identify those compartments that are preferential targets of the particles (RDI > 1). Particle distributions between different groups can be compared in a similar way by contingency table analysis. We first describe the preconditions and the way to implement these methods, then provide three worked examples, and finally discuss the advantages, pitfalls, and limitations of this method.
Resumo:
ABSTRACT: BACKGROUND: Translocation of nanoparticles (NP) from the pulmonary airways into other pulmonary compartments or the systemic circulation is controversially discussed in the literature. In a previous study it was shown that titanium dioxide (TiO2) NP were "distributed in four lung compartments (air-filled spaces, epithelium/endothelium, connective tissue, capillary lumen) in correlation with compartment size". It was concluded that particles can move freely between these tissue compartments. To analyze whether the distribution of TiO2 NP in the lungs is really random or shows a preferential targeting we applied a newly developed method for comparing NP distributions. METHODS: Rat lungs exposed to an aerosol containing TiO2 NP were prepared for light and electron microscopy at 1 h and at 24 h after exposure. Numbers of TiO2 NP associated with each compartment were counted using energy filtering transmission electron microscopy. Compartment size was estimated by unbiased stereology from systematically sampled light micrographs. Numbers of particles were related to compartment size using a relative deposition index and chi-squared analysis. RESULTS: Nanoparticle distribution within the four compartments was not random at 1 h or at 24 h after exposure. At 1 h the connective tissue was the preferential target of the particles. At 24 h the NP were preferentially located in the capillary lumen. CONCLUSION: We conclude that TiO2 NP do not move freely between pulmonary tissue compartments, although they can pass from one compartment to another with relative ease. The residence time of NP in each tissue compartment of the respiratory system depends on the compartment and the time after exposure. It is suggested that a small fraction of TiO2 NP are rapidly transported from the airway lumen to the connective tissue and subsequently released into the systemic circulation.
Resumo:
Our goal was to validate accuracy, consistency, and reproducibility/reliability of a new method for determining cup orientation in total hip arthroplasty (THA). This method allows matching the 3D-model from CT images or slices with the projected pelvis on an anteroposterior pelvic radiograph using a fully automated registration procedure. Cup orientation (inclination and anteversion) is calculated relative to the anterior pelvic plane, corrected for individual malposition of the pelvis during radiograph acquisition. Measurements on blinded and randomized radiographs of 80 cadaver and 327 patient hips were investigated. The method showed a mean accuracy of 0.7 +/- 1.7 degrees (-3.7 degrees to 4.0 degrees) for inclination and 1.2 +/- 2.4 degrees (-5.3 degrees to 5.6 degrees) for anteversion in the cadaver trials and 1.7 +/- 1.7 degrees (-4.6 degrees to 5.5 degrees) for inclination and 0.9 +/- 2.8 degrees (-5.2 degrees to 5.7 degrees) for anteversion in the clinical data when compared to CT-based measurements. No systematic errors in accuracy were detected with the Bland-Altman analysis. The software consistency and the reproducibility/reliability were very good. This software is an accurate, consistent, reliable, and reproducible method to measure cup orientation in THA using a sophisticated 2D/3D-matching technique. Its robust and accurate matching algorithm can be expanded to statistical models.
Resumo:
BACKGROUND AND OBJECTIVES: Nerve blocks using local anesthetics are widely used. High volumes are usually injected, which may predispose patients to associated adverse events. Introduction of ultrasound guidance facilitates the reduction of volume, but the minimal effective volume is unknown. In this study, we estimated the 50% effective dose (ED50) and 95% effective dose (ED95) volume of 1% mepivacaine relative to the cross-sectional area of the nerve for an adequate sensory block. METHODS: To reduce the number of healthy volunteers, we used a volume reduction protocol using the up-and-down procedure according to the Dixon average method. The ulnar nerve was scanned at the proximal forearm, and the cross-sectional area was measured by ultrasound. In the first volunteer, a volume of 0.4 mL/mm of nerve cross-sectional area was injected under ultrasound guidance in close proximity to and around the nerve using a multiple injection technique. The volume in the next volunteer was reduced by 0.04 mL/mm in case of complete blockade and augmented by the same amount in case of incomplete sensory blockade within 20 mins. After 3 up-and-down cycles, ED50 and ED95 were estimated. Volunteers and physicians performing the block were blinded to the volume used. RESULTS: A total 17 of volunteers were investigated. The ED50 volume was 0.08 mL/mm (SD, 0.01 mL/mm), and the ED95 volume was 0.11 mL/mm (SD, 0.03 mL/mm). The mean cross-sectional area of the nerves was 6.2 mm (1.0 mm). CONCLUSIONS: Based on the ultrasound measured cross-sectional area and using ultrasound guidance, a mean volume of 0.7 mL represents the ED95 dose of 1% mepivacaine to block the ulnar nerve at the proximal forearm.
Resumo:
Gauging the maximum willingness to pay (WTP) of a product accurately is a critical success factor that determines not only market performance but also financial results. A number of approaches have therefore been developed to accurately estimate consumers’ willingness to pay. Here, four commonly used measurement approaches are compared using real purchase data as a benchmark. The relative strengths of each method are analyzed on the basis of statistical criteria and, more importantly, on their potential to predict managerially relevant criteria such as optimal price, quantity and profit. The results show a slight advantage of incentive-aligned approaches though the market settings need to be considered to choose the best-fitting procedure.
Resumo:
Chronic heart transplant rejection, i.e. cardiac allograft vasculopathy (CAV) is a major adverse prognostic factor after heart transplantation (HTx). This study tested the hypothesis that the relative myocardial blood volume (rBV) as quantified by myocardial contrast echocardiography accurately detects severe CAV as defined by coronary intravascular ultrasound (IVUS).
Resumo:
High reflective materials in the microwave region play a very important role in the realization of antenna reflectors for a broad range of applications, including radiometry. These reflectors have a characteristic emissivity which needs to be characterized accurately in order to perform a correct radiometric calibration of the instrument. Such a characterization can be performed by using open resonators, waveguide cavities or by radiometric measurements. The latter consists of comparative radiometric observations of absorbers, reference mirrors and the sample under test, or using the cold sky radiation as a direct reference source. While the first two mentioned techniques are suitable for the characterization of metal plates and mirrors, the latter has the advantages to be also applicable to soft materials. This paper describes how, through this radiometric techniques, it is possible to characterize the emissivity of the sample relative to a reference mirror and how to characterize the absolute emissivity of the latter by performing measurements at different incident angles. The results presented in this paper are based on our investigations on emissivity of a multilayer insulation material (MLI) for space mission, at the frequencies of 22 and 90 GHz.
Resumo:
In this study, the development of a new sensitive method for the analysis of alpha-dicarbonyls glyoxal (G) and methylglyoxal (MG) in environmental ice and snow is presented. Stir bar sorptive extraction with in situ derivatization and liquid desorption (SBSE-LD) was used for sample extraction, enrichment, and derivatization. Measurements were carried out using high-performance liquid chromatography coupled to electrospray ionization tandem mass spectrometry (HPLC-ESI-MS/MS). As part of the method development, SBSE-LD parameters such as extraction time, derivatization reagent, desorption time and solvent, and the effect of NaCl addition on the SBSE efficiency as well as measurement parameters of HPLC-ESI-MS/MS were evaluated. Calibration was performed in the range of 1–60 ng/mL using spiked ultrapure water samples, thus incorporating the complete SBSE and derivatization process. 4-Fluorobenzaldehyde was applied as internal standard. Inter-batch precision was <12 % RSD. Recoveries were determined by means of spiked snow samples and were 78.9 ± 5.6 % for G and 82.7 ± 7.5 % for MG, respectively. Instrumental detection limits of 0.242 and 0.213 ng/mL for G and MG were achieved using the multiple reaction monitoring mode. Relative detection limits referred to a sample volume of 15 mL were 0.016 ng/mL for G and 0.014 ng/mL for MG. The optimized method was applied for the analysis of snow samples from Mount Hohenpeissenberg (close to the Meteorological Observatory Hohenpeissenberg, Germany) and samples from an ice core from Upper Grenzgletscher (Monte Rosa massif, Switzerland). Resulting concentrations were 0.085–16.3 ng/mL for G and 0.126–3.6 ng/mL for MG. Concentrations of G and MG in snow were 1–2 orders of magnitude higher than in ice core samples. The described method represents a simple, green, and sensitive analytical approach to measure G and MG in aqueous environmental samples.
Resumo:
BACKGROUND To summarize the available evidence on the effectiveness of psychological interventions for patients with post-traumatic stress disorder (PTSD). METHOD We searched bibliographic databases and reference lists of relevant systematic reviews and meta-analyses for randomized controlled trials that compared specific psychological interventions for adults with PTSD symptoms either head-to-head or against control interventions using non-specific intervention components, or against wait-list control. Two investigators independently extracted the data and assessed trial characteristics. RESULTS The analyses included 4190 patients in 66 trials. An initial network meta-analysis showed large effect sizes (ESs) for all specific psychological interventions (ESs between -1.10 and -1.37) and moderate effects of psychological interventions that were used to control for non-specific intervention effects (ESs -0.58 and -0.62). ES differences between various types of specific psychological interventions were absent to small (ES differences between 0.00 and 0.27). Considerable between-trial heterogeneity occurred (τ 2 = 0.30). Stratified analyses revealed that trials that adhered to DSM-III/IV criteria for PTSD were associated with larger ESs. However, considerable heterogeneity remained. Heterogeneity was reduced in trials with adequate concealment of allocation and in large-sized trials. We found evidence for small-study bias. CONCLUSIONS Our findings show that patients with a formal diagnosis of PTSD and those with subclinical PTSD symptoms benefit from different psychological interventions. We did not identify any intervention that was consistently superior to other specific psychological interventions. However, the robustness of evidence varies considerably between different psychological interventions for PTSD, with most robust evidence for cognitive behavioral and exposure therapies.
Resumo:
BACKGROUND Quantitative light intensity analysis of the strut core by optical coherence tomography (OCT) may enable assessment of changes in the light reflectivity of the bioresorbable polymeric scaffold from polymer to provisional matrix and connective tissues, with full disappearance and integration of the scaffold into the vessel wall. The aim of this report was to describe the methodology and to apply it to serial human OCT images post procedure and at 6, 12, 24 and 36 months in the ABSORB cohort B trial. METHODS AND RESULTS In serial frequency-domain OCT pullbacks, corresponding struts at different time points were identified by 3-dimensional foldout view. The peak and median values of light intensity were measured in the strut core by dedicated software. A total of 303 corresponding struts were serially analyzed at 3 time points. In the sequential analysis, peak light intensity increased gradually in the first 24 months after implantation and reached a plateau (relative difference with respect to baseline [%Dif]: 61.4% at 12 months, 115.0% at 24 months, 110.7% at 36 months), while the median intensity kept increasing at 36 months (%Dif: 14.3% at 12 months, 75.0% at 24 months, 93.1% at 36 months). CONCLUSIONS Quantitative light intensity analysis by OCT was capable of detecting subtle changes in the bioresorbable strut appearance over time, and could be used to monitor the bioresorption and integration process of polylactide struts.
Resumo:
In this work, a method that synchronizes two video sequences is proposed. Unlike previous methods, which require the existence of correspondences between features tracked in the two sequences, and/or that the cameras are static or jointly moving, the proposed approach does not impose any of these constraints. It works when the cameras move independently, even if different features are tracked in the two sequences. The assumptions underlying the proposed strategy are that the intrinsic parameters of the cameras are known and that two rigid objects, with independent motions on the scene, are visible in both sequences. The relative motion between these objects is used as clue for the synchronization. The extrinsic parameters of the cameras are assumed to be unknown. A new synchronization algorithm for static or jointly moving cameras that see (possibly) different parts of a common rigidly moving object is also proposed. Proof-of-concept experiments that illustrate the performance of these methods are presented, as well as a comparison with a state-of-the-art approach.
Resumo:
OBJECTIVE To assess the reliability of the cervical vertebrae maturation method (CVM). BACKGROUND Skeletal maturity estimation can influence the manner and time of orthodontic treatment. The CVM method evaluates skeletal growth on the basis of the changes in the morphology of cervical vertebrae C2, C3, C4 during growth. These vertebrae are visible on a lateral cephalogram, so the method does not require an additional radiograph. METHODS In this website based study, 10 orthodontists with a long clinical practice (3 routinely using the method - "Routine user - RU" and 7 with less experience in the CVM method - "Non-Routine user - nonRU") rated twice cervical vertebrae maturation with the CVM method on 50 cropped scans of lateral cephalograms of children in circumpubertal age (for boys: 11.5 to 15.5 years; for girls: 10 to 14 years). Kappa statistics (with lower limits of 95% confidence intervals (CI)) and proportion of complete agreement on staging was used to evaluate intra- and inter-assessor agreement. RESULTS The mean weighted kappa for intra-assessor agreement was 0.44 (range: 0.30-0.64; range of lower limits of 95% CI: 0.12-0.48) and for inter-assessor agreement was 0.28 (range: -0.01-0.58; range of lower limits of 95% CI: -0.14-0.42). The mean proportion of identical scores assigned by the same assessor was 55.2 %(range: 44-74 %) and for different pairs of assessors was 42 % (range: 16-68 %). CONCLUSIONS The reliability of the CVM method is questionable and if orthodontic treatment should be initiated relative to the maximum growth, the use of additional biologic indicators should be considered (Tab. 4, Fig. 1, Ref. 24).