Resumo:
BACKGROUND: The quality of surgical performance depends on the technical skills of the surgical team as well as on non-technical skills, including teamwork. The present study evaluated the impact of familiarity among members of the surgical team on morbidity in patients undergoing elective open abdominal surgery. METHODS: A retrospective analysis was performed to compare the surgical outcomes of patients who underwent major abdominal operations between the first month (period I) and the last month (period II) of a 6-month period of continuous teamwork (stable dyads of one senior and one junior surgeon formed every 6 months). Of 117 patients, 59 and 58 patients underwent operations during period I and period II, respectively, between January 2010 and June 2012. Team performance was assessed via questionnaire by specialized work psychologists; in addition, intraoperative sound levels were measured. RESULTS: The incidence of overall complications was significantly higher in period I than in period II (54.2 vs. 34.5 %; P = 0.041). Postoperative complications grade <3 were significantly more frequently diagnosed in patients who had operations during period I (39.0 vs. 15.5 %; P = 0.007), whereas no between-group differences in grade ≥3 complications were found (15.3 vs. 19.0 %; P = 0.807). Concentration scores from senior surgeons were significantly higher in period II than in period I (P = 0.033). Sound levels during the middle third part of the operations were significantly higher in period I (median above the baseline 8.85 dB [range 4.5-11.3 dB] vs. 7.17 dB [5.24-9.43 dB]; P < 0.001). CONCLUSIONS: Team familiarity improves team performance and reduces morbidity in patients undergoing abdominal surgery.
Resumo:
BACKGROUND AND METHODS We conducted a focus group analysis with students and surgeons on factors which influence medical school students' education in the operating room (OR). The interviews were analyzed using grounded theory. RESULTS The analysis resulted in 18 detailed and easily applyable themes, which were grouped into the four categories: "Students' preparation and organizational aspects", "Learning objectives", "Educational strategies for the teacher", and "Social-environmental aspects". CONCLUSION By including students and surgeons, we were able to extend existing knowledge and enable better understanding of factors influencing teaching in the OR.
Resumo:
Noise peaks are powerful distractors. This study focuses on the impact of noise peaks on surgical teams' communication during 109 long abdominal surgeries. We related measured noise peaks during 5-min intervals to the amount of observed communication during the same interval. Results show that noise peaks are associated with less case-relevant communication; this effect is moderated by the level of surgical experience; case-relevant communications decrease under high noise peak conditions among junior, but not among senior surgeons. However, case-irrelevant communication did not decrease under high noise level conditions, rather there was a trend to more case-irrelevant communication under high noise peaks. The results support the hypothesis that noise peaks impair communication because they draw on attentional resources rather than impairing understanding of communication. As case-relevant communication is important for surgical performance, exposure to high noise peaks in the OR should be minimised especially for less experienced surgeons. Practitioner Summary: This study investigated whether noise during surgeries influenced the communication within surgical teams. During abdominal surgeries, noise levels were measured and communication was observed. Results showed that high noise peaks reduced the frequency of patient-related communication, but did not reduce patient-irrelevant communication. Noise may negatively affect team coordination in surgeries.
Resumo:
RATIONALE, AIMS AND OBJECTIVES Safety climate measurements are a broadly used element of improvement initiatives. In order to provide a sound and easy-to-administer instrument for the use in Swiss hospitals, we translated the Safety Climate Survey into German and French. METHODS After translating the Safety Climate Survey into French and German, a cross-sectional survey study was conducted with health care professionals (HCPs) in operating room (OR) teams and on OR-related wards in 10 Swiss hospitals. Validity of the instrument was examined by means of Cronbach's alpha and missing rates of the single items. Item-descriptive statistics group differences and percentage of 'problematic responses' (PPR) were calculated. RESULTS 3153 HCPs completed the survey (response rate: 63.4%). 1308 individuals were excluded from the analyses because of a profession other than doctor or nurse or invalid answers (n = 1845; nurses = 1321, doctors = 523). Internal consistency of the translated Safety Climate Survey was good (Cronbach's alpha G erman = 0.86; Cronbach's alpha F rench = 0.84). Missing rates at item level were rather low (0.23-4.3%). We found significant group differences in safety climate values regarding profession, managerial function, work area and time spent in direct patient care. At item level, 14 out of 21 items showed a PPR higher than 10%. CONCLUSIONS Results indicate that the French and German translations of the Safety Climate Survey might be a useful measurement instrument for safety climate in Swiss hospital units. Analyses at item level allow for differentiating facets of safety climate into more positive and critical safety climate aspects.
Resumo:
BACKGROUND: Physiologic data display is essential to decision making in critical care. Current displays echo first-generation hemodynamic monitors dating to the 1970s and have not kept pace with new insights into physiology or the needs of clinicians who must make progressively more complex decisions about their patients. The effectiveness of any redesign must be tested before deployment. Tools that compare current displays with novel presentations of processed physiologic data are required. Regenerating conventional physiologic displays from archived physiologic data is an essential first step. OBJECTIVES: The purposes of the study were to (1) describe the SSSI (single sensor single indicator) paradigm that is currently used for physiologic signal displays, (2) identify and discuss possible extensions and enhancements of the SSSI paradigm, and (3) develop a general approach and a software prototype to construct such "extended SSSI displays" from raw data. RESULTS: We present Multi Wave Animator (MWA) framework-a set of open source MATLAB (MathWorks, Inc., Natick, MA, USA) scripts aimed to create dynamic visualizations (eg, video files in AVI format) of patient vital signs recorded from bedside (intensive care unit or operating room) monitors. Multi Wave Animator creates animations in which vital signs are displayed to mimic their appearance on current bedside monitors. The source code of MWA is freely available online together with a detailed tutorial and sample data sets.
Resumo:
PURPOSE: The advent of imaging software programs has proved to be useful for diagnosis, treatment planning, and outcome measurement, but precision of 3-dimensional (3D) surgical simulation still needs to be tested. This study was conducted to determine whether the virtual surgery performed on 3D models constructed from cone-beam computed tomography (CBCT) can correctly simulate the actual surgical outcome and to validate the ability of this emerging technology to recreate the orthognathic surgery hard tissue movements in 3 translational and 3 rotational planes of space. MATERIALS AND METHODS: Construction of pre- and postsurgery 3D models from CBCTs of 14 patients who had combined maxillary advancement and mandibular setback surgery and 6 patients who had 1-piece maxillary advancement surgery was performed. The postsurgery and virtually simulated surgery 3D models were registered at the cranial base to quantify differences between simulated and actual surgery models. Hotelling t tests were used to assess the differences between simulated and actual surgical outcomes. RESULTS: For all anatomic regions of interest, there was no statistically significant difference between the simulated and the actual surgical models. The right lateral ramus was the only region that showed a statistically significant, but small difference when comparing 2- and 1-jaw surgeries. CONCLUSIONS: Virtual surgical methods were reliably reproduced. Oral surgery residents could benefit from virtual surgical training. Computer simulation has the potential to increase predictability in the operating room.
Resumo:
To prevent iatrogenic damage, transfusions of red blood cells should be avoided. For this, specific and reliable transfusion triggers must be defined. To date, the optimal hematocrit during the initial operating room (OR) phase is still unclear in patients with severe traumatic brain injury (TBI). We hypothesized that hematocrit values exceeding 28%, the local hematocrit target reached by the end of the initial OR phase, resulted in more complications, increased mortality, and impaired recovery compared to patients in whom hematocrit levels did not exceed 28%.
Resumo:
Cranioplasty is a commonly performed procedure. Outcomes can be improved by the use of patient specific implants, however, high costs limit their accessibility. This paper presents a low cost alternative technique to create patient specific polymethylmethacrylate (PMMA) implants using rapid prototyped mold template. We used available patient's CT-scans, one dataset without craniotomy and one with craniotomy, for computer-assisted design of a 3D mold template, which itself can be brought into the operating room and be used for fast and easy building of a PMMA implant. We applied our solution to three patients with positive outcomes and no complications.