65 resultados para multimodal reflection
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Accurate placement of lesions is crucial for the effectiveness and safety of a retinal laser photocoagulation treatment. Computer assistance provides the capability for improvements to treatment accuracy and execution time. The idea is to use video frames acquired from a scanning digital ophthalmoscope (SDO) to compensate for retinal motion during laser treatment. This paper presents a method for the multimodal registration of the initial frame from an SDO retinal video sequence to a retinal composite image, which may contain a treatment plan. The retinal registration procedure comprises the following steps: 1) detection of vessel centerline points and identification of the optic disc; 2) prealignment of the video frame and the composite image based on optic disc parameters; and 3) iterative matching of the detected vessel centerline points in expanding matching regions. This registration algorithm was designed for the initialization of a real-time registration procedure that registers the subsequent video frames to the composite image. The algorithm demonstrated its capability to register various pairs of SDO video frames and composite images acquired from patients.
Resumo:
n this paper we present a novel hybrid approach for multimodal medical image registration based on diffeomorphic demons. Diffeomorphic demons have proven to be a robust and efficient way for intensity-based image registration. A very recent extension even allows to use mutual information (MI) as a similarity measure to registration multimodal images. However, due to the intensity correspondence uncertainty existing in some anatomical parts, it is difficult for a purely intensity-based algorithm to solve the registration problem. Therefore, we propose to combine the resulting transformations from both intensity-based and landmark-based methods for multimodal non-rigid registration based on diffeomorphic demons. Several experiments on different types of MR images were conducted, for which we show that a better anatomical correspondence between the images can be obtained using the hybrid approach than using either intensity information or landmarks alone.
Resumo:
A multimodal approach is state-of-the art for effective treatment of functional gastrointestinal disorders (FGD) like irritable bowel syndrome and functional dyspepsia. Based on the now established view that the pathogenesis of FGD is multicausal, evidence-based therapeutic options comprise education about the nature of the disorder, dietary modifications, relaxation techniques, behavioral changes, and pharmacological treatments. These therapies are variously combined depending on the severity of the FGD and the individual needs of the patient. Our overview portrays the options for the therapy of FGD and proposes that these are best provided by an interdisciplinary team of primary care physicians, gastroenterologists, and psychosomatic medicine specialists.
Resumo:
An algorithm for the real-time registration of a retinal video sequence captured with a scanning digital ophthalmoscope (SDO) to a retinal composite image is presented. This method is designed for a computer-assisted retinal laser photocoagulation system to compensate for retinal motion and hence enhance the accuracy, speed, and patient safety of retinal laser treatments. The procedure combines intensity and feature-based registration techniques. For the registration of an individual frame, the translational frame-to-frame motion between preceding and current frame is detected by normalized cross correlation. Next, vessel points on the current video frame are identified and an initial transformation estimate is constructed from the calculated translation vector and the quadratic registration matrix of the previous frame. The vessel points are then iteratively matched to the segmented vessel centerline of the composite image to refine the initial transformation and register the video frame to the composite image. Criteria for image quality and algorithm convergence are introduced, which assess the exclusion of single frames from the registration process and enable a loss of tracking signal if necessary. The algorithm was successfully applied to ten different video sequences recorded from patients. It revealed an average accuracy of 2.47 ± 2.0 pixels (∼23.2 ± 18.8 μm) for 2764 evaluated video frames and demonstrated that it meets the clinical requirements.
Resumo:
PET/CT guidance for percutaneous interventions allows biopsy of suspicious metabolically active bone lesions even when no morphological correlation is delineable in the CT images. Clinical use of PET/CT guidance with conventional step-by-step technique is time consuming and complicated especially in cases in which the target lesion is not shown in the CT image. Our recently developed multimodal instrument guidance system (IGS) for PET/CT improved this situation. Nevertheless, bone biopsies even with IGS have a trade-off between precision and intervention duration which is proportional to patient and personnel exposure to radiation. As image acquisition and reconstruction of PET may take up to 10 minutes, preferably only one time consuming combined PET/CT acquisition should be needed during an intervention. In case of required additional control images in order to check for possible patient movements/deformations, or to verify the final needle position in the target, only fast CT acquisitions should be performed. However, for precise instrument guidance accounting for patient movement and/or deformation without having a control PET image, it is essential to be able to transfer the position of the target as identified in the original PET/CT to a changed situation as shown in the control CT.
Resumo:
A new multimodal biometric database designed and acquired within the framework of the European BioSecure Network of Excellence is presented. It is comprised of more than 600 individuals acquired simultaneously in three scenarios: 1) over the Internet, 2) in an office environment with desktop PC, and 3) in indoor/outdoor environments with mobile portable hardware. The three scenarios include a common part of audio/video data. Also, signature and fingerprint data have been acquired both with desktop PC and mobile portable hardware. Additionally, hand and iris data were acquired in the second scenario using desktop PC. Acquisition has been conducted by 11 European institutions. Additional features of the BioSecure Multimodal Database (BMDB) are: two acquisition sessions, several sensors in certain modalities, balanced gender and age distributions, multimodal realistic scenarios with simple and quick tasks per modality, cross-European diversity, availability of demographic data, and compatibility with other multimodal databases. The novel acquisition conditions of the BMDB allow us to perform new challenging research and evaluation of either monomodal or multimodal biometric systems, as in the recent BioSecure Multimodal Evaluation campaign. A description of this campaign including baseline results of individual modalities from the new database is also given. The database is expected to be available for research purposes through the BioSecure Association during 2008.
Resumo:
As more investigations into factors affecting the quality of life of patients with multiple sclerosis (MS) are undertaken, it is becoming increasingly apparent that certain comorbidities and associated symptoms commonly found in these patients differ in incidence, pathophysiology and other factors compared with the general population. Many of these MS-related symptoms are frequently ignored in assessments of disease status and are often not considered to be associated with the disease. Research into how such comorbidities and symptoms can be diagnosed and treated within the MS population is lacking. This information gap adds further complexity to disease management and represents an unmet need in MS, particularly as early recognition and treatment of these conditions can improve patient outcomes. In this manuscript, we sought to review the literature on the comorbidities and symptoms of MS and to summarize the evidence for treatments that have been or may be used to alleviate them.
Resumo:
We present assembly and application of an optical reflectometer for the analysis of dental erosion. The erosive procedure involved acid-induced softening and initial substance loss phases, which are considered to be difficult for visual diagnosis in a clinic. Change of the specular reflection signal showed the highest sensitivity for the detection of the early softening phase of erosion among tested methods. The exponential decrease of the specular reflection intensity with erosive duration was compared to the increase of enamel roughness. Surface roughness was measured by optical analysis, and the observed tendency was correlated with scanning electron microscopy images of eroded enamel. A high correlation between specular reflection intensity and measurement of enamel softening (r(2) ? -0.86) as well as calcium release (r(2) ? -0.86) was found during erosion progression. Measurement of diffuse reflection revealed higher tooth-to-tooth deviation in contrast to the analysis of specular reflection intensity and lower correlation with other applied methods (r(2) = 0.42-0.48). The proposed optical method allows simple and fast surface analysis and could be used for further optimization and construction of the first noncontact and cost-effective diagnostic tool for early erosion assessment in vivo.
Evaluation of perpendicular reflection intensity for assessment of caries lesion activity/inactivity
Resumo:
The aim of this study was to evaluate, using visual assessment, an experimental optical sensor measuring perpendicular reflection intensity (PRI) as an indicator of enamel caries lesion activity/inactivity. Forty teeth with either an active or an inactive enamel lesion were selected from a pool of extracted teeth. Each tooth was cut into halves, with a clinically sound half and a half with a non-cavitated enamel lesion. After gentle plaque removal, the teeth were kept moistened. The lesions were then photographed and a defined measuring site per lesion was chosen and indicated with an arrow on a printout. Independently, the chosen site was visually assessed for lesion activity, and its glossiness was measured with PRI assessment. Surface roughness (SR) was assessed with optical profilometry using a confocal microscope. Visual assessment and PRI were repeated after several weeks and a reliability analysis was performed. For enamel lesions visually scored as active versus inactive, significantly different values were obtained with both PRI and SR. PRI values of the clinically sound control surfaces were significantly different only from active lesions. Generally, inactive lesions had the same glossiness and the same roughness as the sound control surfaces. The reliabilities for visual assessment (? = 0.89) and for PRI (ICC = 0.86) were high. It is concluded that, within the limits of this study, PRI can be regarded as a promising tool for quantitative enamel lesion activity assessment. There is scope and potential for the PRI device to be considerably improved for in vivo use.
Resumo:
To support development tools like debuggers, runtime systems need to provide a meta-programming interface to alter their semantics and access internal data. Reflective capabilities are typically fixed by the Virtual Machine (VM). Unanticipated reflective features must either be simulated by complex program transformations, or they require the development of a specially tailored VM. We propose a novel approach to behavioral reflection that eliminates the barrier between applications and the VM by manipulating an explicit tower of first-class interpreters. Pinocchio is a proof-of-concept implementation of our approach which enables radical changes to the interpretation of programs by explicitly instantiating subclasses of the base interpreter. We illustrate the design of Pinocchio through non-trivial examples that extend runtime semantics to support debugging, parallel debugging, and back-in-time object-flow debugging. Although performance is not yet addressed, we also discuss numerous opportunities for optimization, which we believe will lead to a practical approach to behavioral reflection.
Resumo:
Publishing is an essential means of validation and communication of research. This is no different in transdisciplinary research, where publishing also aims at contributing to the development of society through sharing of knowledge. In the scientific world, authors need to disseminate and validate results, reflect on issues, and participate in debates. On the other hand, institutions and individuals are assessed according to their publication record – as probably the most influential of all current evaluation criteria. Occupying the space between article production and counting impact factors, journal editors and reviewers play an important role in defining and using rules to assess and improve the work submitted to them. Publishing transdisciplinary research poses specific challenges, in particular with regard to peer-review processes, as it addresses different knowledge communities with different value systems and purposes.