218 resultados para mitral valve regurgitation
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
The clinical and echocardiographic characteristics of 108 horses with echocardiographically confirmed mild mitral valve regurgitation (MR) were investigated along with its clinical progression. Follow-up consisted of a re-examination of 28 horses and questionnaires were used to obtain information on a further 43 cases. Thirty-seven horses with mild MR were lost to follow-up. Horses with mild MR were re-examined between 2 and 9 years (3.8+/-1.8 years) following first presentation, with mild MR still present and a small, but statistically significant (P=0.049) increase of left ventricular diameter in end-diastole. These results suggested that mild MR has a good mid-term prognosis in sport and pleasure horses.
Resumo:
An unusual case of localized amyloid light-chain (AL) amyloidosis and extramedullary plasmacytoma of the mitral valve is described. The worsening of a mitral regurgitation led to investigations and surgery. The valve presented marked distortion and thickening by type AL amyloid associated with a monotypic CD138+ immunoglobulin lambda plasma cell proliferation. Systemic staging showed a normal bone marrow and no evidence of amyloid deposition in other localizations. The patient's outcome after mitral valve replacement was excellent. To our knowledge, this is the first description of a localized AL amyloidosis as well as of a primary extramedullary plasmacytoma of the mitral valve.
Resumo:
Transcatheter aortic valve implantation (TAVI) has demonstrated the feasibility of treating valvular heart disease with transcatheter therapy. On the back of this success, various transcatheter concepts are being evaluated to treat other valvular disease, especially mitral regurgitation (MR). The concepts currently approved to treat MR replicate surgical mitral valve repair. However, most of them cannot eliminate MR completely. Similar to TAVI, a transcatheter mitral valve implantation may provide a valuable alternative. The FORTIS transcatheter mitral valve (Edwards Lifesciences, Irvine, CA, USA) is a self-expanding device implanted via a transapical approach. We describe our experience and early results in the first five patients treated on compassionate grounds. We also describe the details of the device, selection criteria and technical details of implantation.
Resumo:
BACKGROUND The use of transcatheter mitral valve repair (TMVR) has gained widespread acceptance in Europe, but data on immediate success, safety, and long-term echocardiographic follow-up in real-world patients are still limited. OBJECTIVES The aim of this multinational registry is to present a real-world overview of TMVR use in Europe. METHODS The Transcatheter Valve Treatment Sentinel Pilot Registry is a prospective, independent, consecutive collection of individual patient data. RESULTS A total of 628 patients (mean age 74.2 ± 9.7 years, 63.1% men) underwent TMVR between January 2011 and December 2012 in 25 centers in 8 European countries. The prevalent pathogenesis was functional mitral regurgitation (FMR) (n = 452 [72.0%]). The majority of patients (85.5%) were highly symptomatic (New York Heart Association functional class III or higher), with a high logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation) (20.4 ± 16.7%). Acute procedural success was high (95.4%) and similar in FMR and degenerative mitral regurgitation (p = 0.662). One clip was implanted in 61.4% of patients. In-hospital mortality was low (2.9%), without significant differences between groups. The estimated 1-year mortality was 15.3%, which was similar for FMR and degenerative mitral regurgitation. The estimated 1-year rate of rehospitalization because of heart failure was 22.8%, significantly higher in the FMR group (25.8% vs. 12.0%, p[log-rank] = 0.009). Paired echocardiographic data from the 1-year follow-up, available for 368 consecutive patients in 15 centers, showed a persistent reduction in the degree of mitral regurgitation at 1 year (6.0% of patients with severe mitral regurgitation). CONCLUSIONS This independent, contemporary registry shows that TMVR is associated with high immediate success, low complication rates, and sustained 1-year reduction of the severity of mitral regurgitation and improvement of clinical symptoms.
Resumo:
OBJECTIVES To validate a self-expanding transcatheter valve for off-pump transatrial mitral valve-in-ring (VIR) implantation via a left thoracotomy. METHODS Mitral valve annuloplasty was performed via sternotomy during cardiopulmonary bypass on 9 pigs. After successful weaning from extracorporal circulation, the custom-made, self-expanding transcatheter VIR device was deployed under fluoroscopic guidance within the annuloplasty ring via a left thoracotomy. Hemodynamic data before and after the implantation were recorded. Mitral annulus diameter and valve area were measured by echocardiography. Transvalvular and left-ventricular outflow-tract pressure gradient were measured invasively. RESULTS Eight successful implantations were performed. Implantation failed in 1 pig because of difficulty with technical delivery of the sheath. Mean transatrial procedure time was 12.6 ± 1.7 min. Hemodynamic status during transatrial implantation was stable, and differences were not statistically significant. Mean mitral annulus diameter and mean mitral orifice area were 2.32 ± 0.2 and 3.84 ± 0.55 cm2, respectively. Mild regurgitation was detected in 7 animals and moderate regurgitation in 1. Mean gradients were 6.1 ± 5.0 mm Hg across the device. Postmortem examination confirmed adequate positioning of devices within the annuloplasty ring. CONCLUSIONS This custom-made transcatheter device allows for safe and reproducible off-pump transatrial mitral VIR implantations. Transatrial access is a promising route to facilitate VIR implantations. Our custom-made stent-valve may be suitable for VIR procedures.
Resumo:
AIMS Transcatheter mitral valve replacement (TMVR) is an emerging technology with the potential to treat patients with severe mitral regurgitation at excessive risk for surgical mitral valve surgery. Multimodal imaging of the mitral valvular complex and surrounding structures will be an important component for patient selection for TMVR. Our aim was to describe and evaluate a systematic multi-slice computed tomography (MSCT) image analysis methodology that provides measurements relevant for transcatheter mitral valve replacement. METHODS AND RESULTS A systematic step-by-step measurement methodology is described for structures of the mitral valvular complex including: the mitral valve annulus, left ventricle, left atrium, papillary muscles and left ventricular outflow tract. To evaluate reproducibility, two observers applied this methodology to a retrospective series of 49 cardiac MSCT scans in patients with heart failure and significant mitral regurgitation. For each of 25 geometrical metrics, we evaluated inter-observer difference and intra-class correlation. The inter-observer difference was below 10% and the intra-class correlation was above 0.81 for measurements of critical importance in the sizing of TMVR devices: the mitral valve annulus diameters, area, perimeter, the inter-trigone distance, and the aorto-mitral angle. CONCLUSIONS MSCT can provide measurements that are important for patient selection and sizing of TMVR devices. These measurements have excellent inter-observer reproducibility in patients with functional mitral regurgitation.
Resumo:
The case of a 55-year-old woman is presented, whose clinical signs were initially suggestive of infective endocarditis. Transthoracic echocardiography (TTE) provided the diagnosis of a large left atrial myxoma attached to the anterior mitral leaflet. Perioperative transesophageal echocardiography (TEE) confirmed preoperative findings and assisted the surgical team in the assessment of tumour size, area of attachment, and mobility. Following tumour resection, TEE demonstrated residual moderate mitral valve regurgitation, which resulted in a change of surgical strategy. This report reinforces the importance of intraoperative TEE to facilitate and optimize surgical and anaesthesiological management of patients presenting with non-specific cardiorespiratory symptoms.
Resumo:
In the present report the prevalence, severity, and risk factors of tricuspid valve regurgitation (TR) in 251 heart transplant recipients have been analyzed retrospectively. Tricuspid valve function was studied by color-flow Doppler echocardiogram and annual heart catheterization. The presence or severity of TR was graded on a scale from 0 (no TR) to 4 (severe). Additional postoperative data included rate of rejection, number of endomyocardial biopsies, incidence of transplant vasculopathy, and preoperative and postoperative hemodynamics. The incidence of grade 3 TR increases from 5% at 1 year to 50% at 4 years after transplantation. Multivariate analysis showed rate of rejection and donor heart weight to be significant risk factors. The ischemic intervals as well as the preoperative and postoperative pulmonary hemodynamics did not affect the severity or prevalence of TR. These results indicate that various factors appear to have an impact on the development of TR and that the prevalence might be lowered by a reduction of the number of biopsies performed and when possible, oversizing of donor hearts.
Resumo:
PURPOSE OF REVIEW There is controversy regarding the optimal choice of prosthetic valves in patients less than 65 years of age requiring mitral valve replacement (MVR). Recently, trends for valve replacement are moving towards biological prosthesis also in younger patients, which is justified by the fact that a later valve-in-valve procedure is feasible in the case of degeneration of the tissue valve. This strategy is increasingly recommended in aortic valve surgery but is questionable for MVR. The purpose of this review is to evaluate current guidelines and analyse evidence for biological MVR in patients under 65 years. RECENT FINDINGS There are differences between guidelines of the American Heart Association and those of the European Society of Cardiology concerning the choice of prostheses in patients undergoing MVR. Although the European Society of Cardiology recommends a mechanical mitral valve in patients under 65 years of age, the American Heart Association does not provide detailed advice for these patients. Mitral valve replacement with biological valves in patients under 65 years is associated with higher rates of reoperation due to structural valve deterioration. In addition, several studies showed a decreased survival after biological MVR. SUMMARY Evidence for biological MVR in patients less than 65 years without comorbidities or contraindication for oral anticoagulation does not exist. Recommendations for patients less than 65 years of age should not be blurred by current 'en-vogue' methods for promising but not yet proven valve-in-valve strategies.
Resumo:
A one-year-old healthy sheep received an implant stenting the mural ('posterior') leaflet of the mitral valve. The experiment was authorized by the Cantonal Ethical Committee. The surgery was performed on the open, beating heart during cardiopulmonary bypass (CPB). Management of anaesthesia was based on isoflurane with mechanical intermittent positive pressure ventilation (IPPV) of the lungs, combined with intercostal nerve blocks and intravenous fentanyl and lidocaine. Marked cardiovascular depression occurred towards the end of CPB time and required high doses of dopamine, dobutamine, lidocaine and ephedrine to allow for weaning off the CPB pump. Moreover, severe pulmonary dysfunction developed when IPPV was re-initiated after CPB. Hypoxaemia persisted throughout the recovery from general anaesthesia. Multiple organ failure developed gradually during the three postoperative days, leading to euthanasia of the animal. As described in this case, marked lung injury associated with some degree of failure of other vital organs may occur in sheep after CPB. Intraoperative cardiorespiratory complications when weaning-off may indicate the development of 'post-pump syndrome'.
Resumo:
Transcatheter mitral interventions has been developed to address an unmet clinical need and may be an alternative therapeutic option to surgery with the intent to provide symptomatic and prognostic benefit. Beyond MitraClip therapy, alternative repair technologies are being developed to expand the transcatheter intervention armamentarium. Recently, the feasibility of transcatheter mitral valve implantation in native non-calcified valves has been reported in very high-risk patients. Acknowledging the lack of scientific evidence to date, it is difficult to predict what the ultimate future role of transcatheter mitral valve interventions will be. The purpose of the present report is to review the current state-of-the-art of mitral valve intervention, and to identify the potential future scenarios, which might benefit most from the transcatheter repair and replacement devices under development.
Resumo:
BACKGROUND Cavalier King Charles Spaniels (CKCS) have a high prevalence of inherited macrothrombocytopenia. The purpose of this study was to determine if a mutation in beta1-tubulin correlated with presumptive inherited macrothrombocytopenia. HYPOTHESIS A mutation in beta1-tubulin results in synthesis of an altered beta1-tubulin monomer. alpha-beta tubulin dimers within microtubule protofilaments are unstable, resulting in altered megakaryocyte proplatelet formation. ANIMALS Blood samples were obtained from CKCS and non-CKCS dogs. METHODS DNA was used in polymerase chain reaction (PCR) assays to evaluate beta1-tubulin. Platelet numbers and mean platelet volume (MPV) were evaluated for a correlation with the presence or absence of a mutation identified in beta1-tubulin. Platelets obtained from homozygous, heterozygous, and clear CKCS were further evaluated using electron microscopy and immunofluorescence. RESULTS A mutation in the gene encoding beta1-tubulin correlated with macrothrombocytopenia in CKCS. Electron microscopy and immunofluorescence studies suggest that platelet microtubules are present but most likely are unstable and decreased in number. CONCLUSIONS AND CLINICAL IMPORTANCE The macrothrombocytopenia of CKCS correlated with a mutation in beta1-tubulin. alpha-beta tubulin dimers within protofilaments most likely are unstable, leading to altered proplatelet formation by megakaryocytes. This information will aid in distinguishing inherited from acquired thrombocytopenia. It also provides insight into the mechanism of platelet production by megakaryocytes, and also may prove useful in understanding heart-related changes in macrothrombocytopenic CKCS with concurrent mitral valve regurgitation.