57 resultados para metallic conduction
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
The round window placement of a floating mass transducer (FMT) is a new approach for coupling an implantable hearing system to the cochlea. We evaluated the vibration transfer to the cochlear fluids of an FMT placed at the round window (rwFMT) with special attention to the role of bone conduction. A posterior tympanotomy was performed on eleven ears of seven human whole head specimens. Several rwFMT setups were examined using laser Doppler vibrometry measurements at the stapes and the promontory. In three ears, the vibrations of a bone anchored hearing aid (BAHA) and an FMT fixed to the promontory (pFMT) were compared to explore the role of bone conduction. Vibration transmission to the measuring point at the stapes was best when the rwFMT was perpendicularly placed in the round window and underlayed with connective tissue. Fixation of the rwFMT to the round window exhibited significantly lower vibration transmission. Although measurable, bone conduction from the pFMT was much lower than that of the BAHA. Our results suggest that the rwFMT does not act as a small bone anchored hearing aid, but instead, acts as a direct vibratory stimulator of the round window membrane.
Resumo:
BACKGROUND: Loss-of-function mutations in SCN5A, the gene encoding Na(v)1.5 Na+ channel, are associated with inherited cardiac conduction defects and Brugada syndrome, which both exhibit variable phenotypic penetrance of conduction defects. We investigated the mechanisms of this heterogeneity in a mouse model with heterozygous targeted disruption of Scn5a (Scn5a(+/-) mice) and compared our results to those obtained in patients with loss-of-function mutations in SCN5A. METHODOLOGY/PRINCIPAL FINDINGS: Based on ECG, 10-week-old Scn5a(+/-) mice were divided into 2 subgroups, one displaying severe ventricular conduction defects (QRS interval>18 ms) and one a mild phenotype (QRS< or = 18 ms; QRS in wild-type littermates: 10-18 ms). Phenotypic difference persisted with aging. At 10 weeks, the Na+ channel blocker ajmaline prolonged QRS interval similarly in both groups of Scn5a(+/-) mice. In contrast, in old mice (>53 weeks), ajmaline effect was larger in the severely affected subgroup. These data matched the clinical observations on patients with SCN5A loss-of-function mutations with either severe or mild conduction defects. Ventricular tachycardia developed in 5/10 old severely affected Scn5a(+/-) mice but not in mildly affected ones. Correspondingly, symptomatic SCN5A-mutated Brugada patients had more severe conduction defects than asymptomatic patients. Old severely affected Scn5a(+/-) mice but not mildly affected ones showed extensive cardiac fibrosis. Mildly affected Scn5a(+/-) mice had similar Na(v)1.5 mRNA but higher Na(v)1.5 protein expression, and moderately larger I(Na) current than severely affected Scn5a(+/-) mice. As a consequence, action potential upstroke velocity was more decreased in severely affected Scn5a(+/-) mice than in mildly affected ones. CONCLUSIONS: Scn5a(+/-) mice show similar phenotypic heterogeneity as SCN5A-mutated patients. In Scn5a(+/-) mice, phenotype severity correlates with wild-type Na(v)1.5 protein expression.
Resumo:
Atrioventricular (AV) conduction impairment is well described after surgical aortic valve replacement, but little is known in patients undergoing transcatheter aortic valve implantation (TAVI). We assessed AV conduction and need for a permanent pacemaker in patients undergoing TAVI with the Medtronic CoreValve Revalving System (MCRS) or the Edwards Sapien Valve (ESV). Sixty-seven patients without pre-existing permanent pacemaker were included in the study. Forty-one patients (61%) and 26 patients (39%) underwent successful TAVI with the MCRS and ESV, respectively. Complete AV block occurred in 15 patients (22%), second-degree AV block in 4 (6%), and new left bundle branch block in 15 (22%), respectively. A permanent pacemaker was implanted in 23 patients (34%). Overall PR interval and QRS width increased significantly after the procedure (p <0.001 for the 2 comparisons). Implantation of the MCRS compared to the ESV resulted in a trend toward a higher rate of new left bundle branch block and complete AV block (29% vs 12%, p = 0.09 for the 2 comparisons). During follow-up, complete AV block resolved in 64% of patients. In multivariable regression analysis pre-existing right bundle branch block was the only independent predictor of complete AV block after TAVI (relative risk 7.3, 95% confidence interval 2.4 to 22.2). In conclusion, TAVI is associated with impairment of AV conduction in a considerable portion of patients, patients with pre-existing right bundle branch block are at increased risk of complete AV block, and complete AV block resolves over time in most patients.
Resumo:
Bacteria, yeasts, and viruses are rapidly killed on metallic copper surfaces, and the term "contact killing" has been coined for this process. While the phenomenon was already known in ancient times, it is currently receiving renewed attention. This is due to the potential use of copper as an antibacterial material in health care settings. Contact killing was observed to take place at a rate of at least 7 to 8 logs per hour, and no live microorganisms were generally recovered from copper surfaces after prolonged incubation. The antimicrobial activity of copper and copper alloys is now well established, and copper has recently been registered at the U.S. Environmental Protection Agency as the first solid antimicrobial material. In several clinical studies, copper has been evaluated for use on touch surfaces, such as door handles, bathroom fixtures, or bed rails, in attempts to curb nosocomial infections. In connection to these new applications of copper, it is important to understand the mechanism of contact killing since it may bear on central issues, such as the possibility of the emergence and spread of resistant organisms, cleaning procedures, and questions of material and object engineering. Recent work has shed light on mechanistic aspects of contact killing. These findings will be reviewed here and juxtaposed with the toxicity mechanisms of ionic copper. The merit of copper as a hygienic material in hospitals and related settings will also be discussed.
Resumo:
In this study we sought to evaluate the reproducibility of sensory nerve conduction studies (NCS) using ultrasound-guided needle positioning (USNP).
Resumo:
The aim of this study was to evaluate changes in bone conduction thresholds before, during and after total stapedectomy.
Resumo:
This study sought to compare the neointimal response of metallic everolimus drug-eluting stents (DES) and polymeric everolimus bioresorbable vascular scaffolds (BVS) by optical coherence tomography at 1 year.
Resumo:
The aim of this study was to compare the angiographic changes in coronary geometry of the bioresorbable vascular scaffolds (BVS) and metallic platform stent (MPS) between baseline and follow-up.
Resumo:
The ABSORB cohort A trial using the bioresorbable everolimus-eluting scaffold (BVS revision 1.0, Abbott Vascular) demonstrated a slightly higher acute recoil with BVS than with metallic stents. To reinforce the mechanical strength of the scaffold, the new BVS scaffold (revision 1.1) with modified strut design was developed and tested in the ABSORB cohort B trial. This study sought to evaluate and compare the in vivo acute scaffold recoil of the BVS revision 1.0 in ABSORB cohort A and the BVS revision 1.1 in ABSORB cohort B with the historical recoil of the XIENCE V® everolimus-eluting metal stent (EES, SPIRIT I and II).