32 resultados para intra-laboratory testing
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
The first part of this three-part review on the relevance of laboratory testing of composites and adhesives deals with approval requirements for composite materials. We compare the in vivo and in vitro literature data and discuss the relevance of in vitro analyses. The standardized ISO protocols are presented, with a focus on the evaluation of physical parameters. These tests all have a standardized protocol that describes the entire test set-up. The tests analyse flexural strength, depth of cure, susceptibility to ambient light, color stability, water sorption and solubility, and radiopacity. Some tests have a clinical correlation. A high flexural strength, for instance, decreases the risk of fractures of the marginal ridge in posterior restorations and incisal edge build-ups of restored anterior teeth. Other tests do not have a clinical correlation or the threshold values are too low, which results in an approval of materials that show inferior clinical properties (e.g., radiopacity). It is advantageous to know the test set-ups and the ideal threshold values to correctly interpret the material data. Overall, however, laboratory assessment alone cannot ensure the clinical success of a product.
Resumo:
A liquid chromatography tandem mass spectrometry (LC-MS/MS) confirmatory method for the simultaneous determination of nine corticosteroids in liver, including the four MRL compounds listed in Council Regulation 37/2010, was developed. After an enzymatic deconjugation and a solvent extraction of the liver tissue, the resulting solution was cleaned up through an SPE Oasis HLB cartridge. The analytes were then detected by liquid chromatography-negative-ion electrospray tandem mass spectrometry, using deuterium-labelled internal standards. The procedure was validated as a quantitative confirmatory method according to the Commission Decision 2002/657/EC criteria. The results showed that the method was suitable for statutory residue testing regarding the following performance characteristics: instrumental linearity, specificity, precision (repeatability and intra-laboratory reproducibility), recovery, decision limit (CCα), detection capability (CCβ) and ruggedness. All the corticosteroids can be detected at a concentration around 1 μg kg(-1); the recoveries were above 62% for all the analytes. Repeatability and reproducibility (within-laboratory reproducibility) for all the analytes were below 7.65% and 15.5%, respectively.
Variability of anti-PF4/heparin antibody results obtained by the rapid testing system ID-H/PF4-PaGIA
Resumo:
BACKGROUND: Recent studies have shown that a low clinical pretest probability may be adequate for excluding heparin-induced thrombocytopenia. However, for patients with intermediate or high pretest probability, laboratory testing is essential for confirming or refuting the diagnosis. Rapid assessment of anti-PF4/heparin-antibodies may assist clinical decision-making. OBJECTIVES: To evaluate the performance of rapid ID-H/PF4-PaGIA. In particular, we verified reproducibility of results between plasma and serum specimens, between fresh and frozen samples, and between different ID-H/PF4-polymer lots (polystyrene beads coated with heparin/PF4-complexes). PATIENTS/METHODS: The samples studied were 1376 plasma and 914 corresponding serum samples from patients investigated for suspected heparin-induced thrombocytopenia between January 2000 and October 2008. Anti-PF4/heparin-antibodies were assessed by ID-H/PF4-PaGIA, commercially available ELISAs and heparin-induced platelet aggregation test. RESULTS: Among 914 paired plasma/serum samples we noted discordant results (negative vs. low-titre positive) in nine instances (1%; 95%CI, 0.4-1.6%). Overall, agreement between titres assessed in plasma vs. serum was highly significant (Spearman correlation coefficient, 0.975; P < 0.0001). Forty-seven samples tested both fresh and after freezing/thawing showed a good agreement, with one discordant positive/negative result (Spearman correlation coefficient, 0.970; P < 0.0001). Among 1376 plasma samples we noted a strikingly variable incidence of false negative results (none - 82%; 95%CI, 66-98%), depending on the employed ID-H/PF4-polymer lot. Faulty lots can be recognized by titrating commercial positive controls and stored samples of HIT-patients. CONCLUSION: Laboratories performing the assay should implement stringent internal quality controls in order to recognize potentially faulty ID-H/PF4-polymer lots, thus avoiding false negative results.
Resumo:
Surgical navigation systems visualize the positions and orientations of surgical instruments and implants as graphical overlays onto a medical image of the operated anatomy on a computer monitor. The orthopaedic surgical navigation systems could be categorized according to the image modalities that are used for the visualization of surgical action. In the so-called CT-based systems or 'surgeon-defined anatomy' based systems, where a 3D volume or surface representation of the operated anatomy could be constructed from the preoperatively acquired tomographic data or through intraoperatively digitized anatomy landmarks, a photorealistic rendering of the surgical action has been identified to greatly improve usability of these navigation systems. However, this may not hold true when the virtual representation of surgical instruments and implants is superimposed onto 2D projection images in a fluoroscopy-based navigation system due to the so-called image occlusion problem. Image occlusion occurs when the field of view of the fluoroscopic image is occupied by the virtual representation of surgical implants or instruments. In these situations, the surgeon may miss part of the image details, even if transparency and/or wire-frame rendering is used. In this paper, we propose to use non-photorealistic rendering to overcome this difficulty. Laboratory testing results on foamed plastic bones during various computer-assisted fluoroscopybased surgical procedures including total hip arthroplasty and long bone fracture reduction and osteosynthesis are shown.
Resumo:
In this review some basic aspects of the clinical presentation, the laboratory testing and the management of a child with a bleeding tendency are discussed. It should help the physician in making the decision whether a laboratory examination in a child with a history of bleedings is necessary or not. In addition, the most frequent mechanisms for a defective hemostasis are explained.
Resumo:
BACKGROUND: A pregnant 25-year-old woman at 32 weeks' gestation was admitted to an emergency unit after her husband had found her drowsy and with her tongue bitten. The day before admission, the patient had developed a fever of 39 degrees C, was suffering from headaches, was nauseated and had vomited. On admission, she had anterograde and retrograde amnesia, but no somatic neurological deficits were detected. INVESTIGATIONS: Routine laboratory testing, lumbar puncture, cerebrospinal fluid analysis, routine bacteriology, brain MRI, and polymerase chain reaction testing for neurotropic viruses including herpes simplex virus types 1 and 2. DIAGNOSIS: Maternal herpes simplex virus type 1 encephalitis. MANAGEMENT: Antiviral and anticonvulsive therapy, supportive treatment, and cesarean section.
Resumo:
PURPOSE To report a case of bilateral acute anterior uveitis in association with the application of an analgesic transdermal capsaicin patch. METHODS Case report and review of literature. RESULTS A 38-year-old woman suffered from bilateral acute anterior uveitis, manifesting 12-24 h after application of an analgesic capsaicin patch (Isola Capsicum N Plus) that served to alleviate muscular neck pain. Systemic immune-mediated and infectious diseases were excluded by medical history and laboratory testing. Control of inflammation was achieved with topical corticosteroid treatment within 1 week. Over the course of a 1-year follow-up, no further recurrence of uveitis was observed. CONCLUSIONS The case suggests a possible association of capsaicin-containing transdermal patches and acute anterior uveitis.
Resumo:
Oxygenated polycyclic aromatic hydrocarbons (oxy-PAHs) and nitrogen heterocyclic polycyclic aromatic compounds (N-PACs) are toxic, highly leachable and often abundant at sites that are also contaminated with PAHs. However, due to lack of regulations and standardized methods for their analysis, they are seldom included in monitoring and risk-assessment programs. This intercomparison study constitutes an important step in the harmonization of the analytical methods currently used, and may also be considered a first step towards the certification of reference materials for these compounds. The results showed that the participants were able to determine oxy-PAHs with accuracy similar to PAHs, with average determined mass fractions agreeing well with the known levels in a spiked soil and acceptable inter- and intra-laboratory precisions for all soils analyzed. For the N-PACs, the results were less satisfactory, and have to be improved by using analytical methods more specifically optimized for these compounds.
Resumo:
PRINCIPLES To assess gynaecologists' awareness of bone healthcare in women and the prevalence of application of national recommendations on bone healthcare in Switzerland. METHODS During the annual meeting of the Swiss Society of Gynaecology and Obstetrics 2012, the Swiss Association against Osteoporosis (SVGO) performed standardised interviews with conference participants (n = 210). Questions addressed responsibility for bone healthcare, and whether diagnostic procedures, initiation of bone-specific treatment and follow-up were performed in accordance with SVGO recommendations. RESULTS The majority of respondents were aged 30-50 years (60%), female (70%) and working as board-certified gynaecologists (69%). Ninety-three percent of respondents considered care for bone health as part of the gynaecologist's expertise. As diagnostic procedures, 44% recommended performing bone densitometry (DXA) only, 34% ordered additional laboratory testing. Seventy-two percent of respondents initiated a bone-specific treatment. Predictors for not performing diagnostic procedures and not initiating a bone-specific treatment were physician's age below 30, being a trainee gynaecologist, and working at a university clinic. Particularly, young trainee gynaecologists working at a university clinic were especially unlikely to initiate a bone-specific treatment (regression coefficient = -2.68; odds ratio [OR] 0.069, 95% confidence interval [CI] 0.01-0.61; p = 0.16). Follow-ups were performed by 77% of respondents, but were less likely to be by female physicians (OR 0.27, 95% CI 0.09-0.84; p = 0.024). CONCLUSIONS Although the majority of board-certified gynaecologists follow national recommendations on bone healthcare, current medical training in obstetrics and gynaecology does not sufficiently cover the subject of women's health. However, since this is a small study our findings may not reflect the findings in the total population.
Resumo:
Abstract PRINCIPLES: Computed tomography (CT) is inferior to the fibroscan and laboratory testing in the noninvasive diagnosis of liver fibrosis. On the other hand, CT is a frequently used diagnostic tool in modern medicine. The auxiliary finding of clinically occult liver fibrosis in CT scans could result in an earlier diagnosis. The aim of this study was to analyse quantifiable direct signs of liver remodelling in CT scans to depict liver fibrosis in a precirrhotic stage. METHODS: Retrospective review of 148 abdominal CT scans (80 liver cirrhosis, 35 precirrhotic fibrosis and 33 control patients). Fibrosis and cirrhosis were histologically proven. The diameters of the three main hepatic veins were measured 1-2 cm before their aperture into the inferior caval vein. The width of the caudate and the right hepatic lobe were divided, and measured horizontally at the level of the first bifurcation of the right portal vein in axial planes (caudate-right-lobe ratio). A combination of both (sum of liver vein diameters divided by the caudate-right lobe ratio) was defined as the ld/crl ratio. These metrics were analysed for the detection of liver fibrosis and cirrhosis. RESULTS: An ld/crl-r <24 showed a sensitivity of 83% and a specificity of 76% for precirrhotic liver fibrosis. Liver cirrhosis could be detected with a sensitivity of 88% and a specificity of 82% if ld/crl-r <20. CONCLUSION: An ld/crl-r <24 justifies laboratory testing and a fibroscan. This could bring forward the diagnosis and patients would profit from early treatment in a potentially reversible stage of disease.
Resumo:
Background: The Swiss pig population enjoys a favourable health situation. To further promote this, the Pig Health Service (PHS) conducts a surveillance program in affiliated herds: closed multiplier herds with the highest PHS-health and hygiene status have to be free from swine dysentery and progressive atrophic rhinitis and are clinically examined four times a year, including laboratory testing. Besides, four batches of pigs per year are fattened together with pigs from other herds and checked for typical symptoms (monitored fattening groups (MF)). While costly and laborious, little was known about the effectiveness of the surveillance to detect an infection in a herd. Therefore, the sensitivity of the surveillance for progressive atrophic rhinitis and swine dysentery at herd level was assessed using scenario tree modelling, a method well established at national level. Furthermore, its costs and the time until an infection would be detected were estimated, with the final aim of yielding suggestions how to optimize surveillance. Results: For swine dysentery, the median annual surveillance sensitivity was 96.7 %, mean time to detection 4.4 months, and total annual costs 1022.20 Euro/herd. The median component sensitivity of active sampling was between 62.5 and 77.0 %, that of a MF between 7.2 and 12.7 %. For progressive atrophic rhinitis, the median surveillance sensitivity was 99.4 %, mean time to detection 3.1 months and total annual costs 842.20 Euro. The median component sensitivity of active sampling was 81.7 %, that of a MF between 19.4 and 38.6 %. Conclusions: Results indicate that total sensitivity for both diseases is high, while time to detection could be a risk in herds with frequent pig trade. From all components, active sampling had the highest contribution to the surveillance sensitivity, whereas that of MF was very low. To increase efficiency, active sampling should be intensified (more animals sampled) and MF abandoned. This would significantly improve sensitivity and time to detection at comparable or lower costs. The method of scenario tree modelling proved useful to assess the efficiency of surveillance at herd level. Its versatility allows adjustment to all kinds of surveillance scenarios to optimize sensitivity, time to detection and/or costs.
Resumo:
BACKGROUND Recent technical development allows the digital manufacturing of monolithic reconstructions with high-performance materials. For implant-supported crowns, the fixation requires an abutment design onto which the reconstruction can be bonded. PURPOSE The aim of this laboratory investigation was to analyze stiffness, strength, and failure modes of implant-supported, computer-assisted design and computer-aided manufacturing (CAD/CAM)-generated resin nano ceramic (RNC) crowns bonded to three different titanium abutments. MATERIALS AND METHODS Eighteen monolithic RNC crowns were produced and loaded in a universal testing machine under quasi-static condition according to DIN ISO 14801. With regard to the type of titanium abutment, three groups were defined: (1) prefabricated cementable standard; (2) CAD/CAM-constructed individualized; and (3) novel prefabricated bonding base. Stiffness and strength were measured and analyzed statistically with Wilcoxon rank sum test. Sections of the specimens were examined microscopically. RESULTS Stiffness demonstrated high stability for all specimens loaded in the physiological loading range with means and standard deviations of 1,579 ± 120 N/mm (group A), 1,733 ± 89 N/mm (group B), and 1,704 ± 162 N/mm (group C). Mean strength of the novel prefabricated bonding base (group C) was 17% lower than of the two other groups. Plastic deformations were detectable for all implant-abutment crown connections. CONCLUSIONS Monolithic implant crowns made of RNC seem to represent a feasible and stable prosthetic construction under laboratory testing conditions with strength higher than the average occlusal force, independent of the different abutment designs used in this investigation.
Resumo:
BACKGROUND Thrombotic thrombocytopenic purpura (TTP) is a severe disorder affecting the microcirculation of multiple organs due to a systemic endothelial cell injury secondary to a deficiency in ADAMTS13 (a disintegrin and metalloprotease with thrombospondin type 1 motif, member 13) activity. TTP is a rare complication of pregnancy with a poor prognosis and high fetal mortality, especially when it occurs during the first trimester. Recent data have supported that effective treatment of TTP is plasma therapy. Unfortunately a major problem remains in the delay in diagnosis due to confounding factors between other "imitators of preeclampsia." Rapid and readily available laboratory testing to quickly diagnose TTP is desperately needed to improve care and to save mother and future child life. CASE REPORT We describe a rare case of successful pregnancy after TTP manifestations occurring in the first trimester; most importantly, our experience represents the first case of atypical manifestation due to neurologic and kidney manifestations preceding laboratory assay alterations. RESULTS We treated a patient with plasma replacement of 30 mL/kg/day and daily plasmapheresis in combination with continuous infusion of fresh-frozen plasma 10 mL/kg/day. The response of clinical manifestation immediately improved. At 30 weeks, the patient had multiple episodes of high blood pressure and concomitant decrease of hemoglobin and platelet count, so a cesarean section was immediately performed. She delivered a healthy female baby. CONCLUSION Early diagnosis by ADAMTS13 activity, occasionally occurring before clinical manifestations, aided us in promptly administering commended and life-saving treatments.
Resumo:
There is no accepted way of measuring prothrombin time without time loss for patients undergoing major surgery who are at risk of intraoperative dilution and consumption coagulopathy due to bleeding and volume replacement with crystalloids or colloids. Decisions to transfuse fresh frozen plasma and procoagulatory drugs have to rely on clinical judgment in these situations. Point-of-care devices are considerably faster than the standard laboratory methods. In this study we assessed the accuracy of a Point-of-care (PoC) device measuring prothrombin time compared to the standard laboratory method. Patients undergoing major surgery and intensive care unit patients were included. PoC prothrombin time was measured by CoaguChek XS Plus (Roche Diagnostics, Switzerland). PoC and reference tests were performed independently and interpreted under blinded conditions. Using a cut-off prothrombin time of 50%, we calculated diagnostic accuracy measures, plotted a receiver operating characteristic (ROC) curve and tested for equivalence between the two methods. PoC sensitivity and specificity were 95% (95% CI 77%, 100%) and 95% (95% CI 91%, 98%) respectively. The negative likelihood ratio was 0.05 (95% CI 0.01, 0.32). The positive likelihood ratio was 19.57 (95% CI 10.62, 36.06). The area under the ROC curve was 0.988. Equivalence between the two methods was confirmed. CoaguChek XS Plus is a rapid and highly accurate test compared with the reference test. These findings suggest that PoC testing will be useful for monitoring intraoperative prothrombin time when coagulopathy is suspected. It could lead to a more rational use of expensive and limited blood bank resources.