139 resultados para heart left atrium volume

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Current concepts of catheter ablation for atrial fibrillation (AF) commonly use three-dimensional (3D) reconstructions of the left atrium (LA) for orientation, catheter navigation, and ablation line placement. OBJECTIVES: The purpose of this study was to compare the 3D electroanatomic reconstruction (Carto) of the LA, pulmonary veins (PVs), and esophagus with the true anatomy displayed on multislice computed tomography (CT). METHODS: In this prospective study, 100 patients undergoing AF catheter ablation underwent contrast-enhanced spiral CT scan with barium swallow and subsequent multiplanar and 3D reconstructions. Using Carto, circumferential plus linear LA lesions were placed. The esophagus was tagged and integrated into the Carto map. RESULTS: Compared with the true anatomy on CT, the electroanatomic reconstruction accurately displayed the true distance between the lower PVs; the distances between left upper PV, left lower PV, right lower PV, and center of the esophagus; the longitudinal diameter of the encircling line around the funnel of the left PVs; and the length of the mitral isthmus line. Only the distances between the upper PVs, the distance between the right upper PV and esophagus, and the diameter of the right encircling line were significantly shorter on the electroanatomic reconstructions. Furthermore, electroanatomic tagging of the esophagus reliably visualized the true anatomic relationship to the LA. On multiple tagging and repeated CT scans, the LA and esophagus showed a stable anatomic relationship, without relevant sideward shifting of the esophagus. CONCLUSION: Electroanatomic reconstruction can display with high accuracy the true 3D anatomy of the LA and PVs in most of the regions of interest for AF catheter ablation. In addition, Carto was able to visualize the true anatomic relationship between the esophagus and LA. Both structures showed a stable anatomic relationship on Carto and CT without relevant sideward shifting of the esophagus.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Evidence from animal and human studies imply the amygdala as the most critical structure involved in processing of fear-relevant stimuli. In phobias, the amygdala seems to play a crucial role in the pathogenesis and maintenance of the disorder. However, the neuropathology of specific phobias remains poorly understood. In the present study, we investigated whether patients with spider phobia show altered amygdala volumes as compared to healthy control subjects.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Persistent atrial fibrillation (AF) ablation may lead to partial disconnection of the coronary sinus (CS). As a result, disparate activation sequences of the local CS versus contiguous left atrium (LA) may be observed during atrial tachycardia (AT). We aimed to evaluate the prevalence of this phenomenon and its impact on activation mapping.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The current article presents a novel physiological control algorithm for ventricular assist devices (VADs), which is inspired by the preload recruitable stroke work. This controller adapts the hydraulic power output of the VAD to the end-diastolic volume of the left ventricle. We tested this controller on a hybrid mock circulation where the left ventricular volume (LVV) is known, i.e., the problem of measuring the LVV is not addressed in the current article. Experiments were conducted to compare the response of the controller with the physiological and with the pathological circulation, with and without VAD support. A sensitivity analysis was performed to analyze the influence of the controller parameters and the influence of the quality of the LVV signal on the performance of the control algorithm. The results show that the controller induces a response similar to the physiological circulation and effectively prevents over- and underpumping, i.e., ventricular suction and backflow from the aorta to the left ventricle, respectively. The same results are obtained in the case of a disturbed LVV signal. The results presented in the current article motivate the development of a robust, long-term stable sensor to measure the LVV.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Rapid pulmonary vein (PV) activity has been shown to maintain paroxysmal atrial fibrillation (AF). We evaluated in persistent AF the cycle length (CL) gradient between PVs and the left atrium (LA) in an attempt to identify the subset of patients where PVs play an important role. METHODS AND RESULTS Ninety-seven consecutive patients undergoing first ablation for persistent AF were studied. For each PV, the CL of the fastest activation was assessed over 1 minute (PVfast) using Lasso recordings. The PV to LA CL gradient was quantified by the ratio of PVfast to LA appendage (LAA) AF CL. Stepwise ablation terminated AF in 73 patients (75%). In the AF termination group, the PVfast CL was much shorter than the LAA CL resulting in lower PVfast/LAA ratios compared with the nontermination group (71±10% versus 92±7%; P<0.001). Within the termination group, PVfast/LAA ratios were notably lower if AF terminated after PV isolation or limited adjunctive substrate ablation compared with patients who required moderate or extensive ablation (63±6% versus 75±8%; P<0.001). PVfast/LAA ratio <69% predicted AF termination after PV isolation or limited substrate ablation with 74% positive predictive value and 95% negative predictive value. After a mean follow-up of 29±17 months, freedom from arrhythmia recurrence off-antiarrhythmic drugs was achieved in most patients with PVfast/LAA ratios <69% as opposed to the remaining population (80% versus 43%; P<0.001). CONCLUSIONS The PV to LA CL gradient may identify the subset of patients in whom persistent AF is likely to terminate after PV isolation or limited substrate ablation and better long-term outcomes are achieved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Recent data have suggested a relation among long-term endurance sport practice, left atrial remodeling, and atrial fibrillation. We investigated the influence of an increased vagal tone, represented by the early repolarization (ER) pattern, on diastolic function and left atrial size in professional soccer players. Fifty-four consecutive athletes underwent electrocardiography, echocardiography, and exercise testing as part of their preparticipation screening. Athletes were divided into 2 groups according to presence or absence of an ER pattern, defined as a ST-segment elevation at the J-point (STE) > or =0.1 mm in 2 leads. For linear comparisons average STE was calculated. Mean age was 24 +/- 4 years. Twenty-five athletes (46%) showed an ER pattern. Athletes with an ER pattern had a significant lower heart rate (54 +/- 9 vs 62 +/- 11 beats/min, p = 0.024), an increased E/e' ratio (6.1 +/- 1.2 vs 5.1 +/- 1.0, p = 0.002), and larger volumes of the left atrium (25.6 +/- 7.3 vs 21.8 +/- 5.0 ml/m(2), p = 0.031) compared to athletes without an ER pattern. There were no significant differences concerning maximum workload, left ventricular dimensions, and systolic function. Univariate regression analysis revealed significant correlations among age, STE, and left atrial volume. In a stepwise multivariate regression analysis age, STE and e' contributed independently to left atrial size (r = 0.659, p <0.001). In conclusion, athletes with an ER pattern had an increased E/e' ratio, reflecting a higher left atrial filling pressure, contributing to left atrial remodeling over time.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Left atrium (LA) dilation and P-wave duration are linked to the amount of endurance training and are risk factors for atrial fibrillation (AF). The aim of this study was to evaluate the impact of LA anatomical and electrical remodeling on its conduit and pump function measured by two-dimensional speckle tracking echocardiography (STE). Method Amateur male runners > 30 years were recruited. Study participants (n = 95) were stratified in 3 groups according to lifetime training hours: low (< 1500 h, n = 33), intermediate (1500 to 4500 h, n = 32) and high training group (> 4500 h, n = 30). Results No differences were found, between the groups, in terms of age, blood pressure, and diastolic function. LA maximal volume (30 ± 5, 33 ± 5 vs. 37 ± 6 ml/m2, p < 0.001), and conduit volume index (9 ± 3, 11 ± 3 vs. 12 ± 3 ml/m2, p < 0.001) increased significantly from the low to the high training group, unlike the STE parameters: pump strain − 15.0 ± 2.8, − 14.7 ± 2.7 vs. − 14.9 ± 2.6%, p = 0.927; conduit strain 23.3 ± 3.9, 22.1 ± 5.3 vs. 23.7 ± 5.7%, p = 0.455. Independent predictors of LA strain conduit function were age, maximal early diastolic velocity of the mitral annulus, heart rate and peak early diastolic filling velocity. The signal-averaged P-wave (135 ± 11, 139 ± 10 vs. 148 ± 14 ms, p < 0.001) increased from the low to the high training group. Four episodes of non-sustained AF were recorded in one runner of the high training group. Conclusion The LA anatomical and electrical remodeling does not have a negative impact on atrial mechanical function. Hence, a possible link between these risk factors for AF and its actual, rare occurrence in this athlete population, could not be uncovered in the present study.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mapping and ablation of atrial tachycardias (ATs) secondary to catheter ablation of atrial fibrillation (AF) is often challenging due to the complex atrial substrate, different AT mechanisms, and potential origin not only in the left atrium (LA) but also from the right atrium (RA) and the adjacent thoracic veins.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mitral regurgitation (MR) involves systolic retrograde flow from the left ventricle into the left atrium. While trivial MR is frequent in healthy subjects, moderate to severe MR constitutes the second most prevalent valve disease after aortic valve stenosis. Major causes of severe MR in Western countries include degenerative valve disease (myxomatous disease, flail leaflet, annular calcification) and ischaemic heart disease, while rheumatic disease remains a major cause of MR in developing countries. Chronic MR typically progresses insidiously over many years. Once established, however, severe MR portends a poor prognosis. The severity of MR can be assessed by various techniques, Doppler echocardiography being the most widely used. Mitral valve surgery is the only treatment of proven efficacy. It alleviates clinical symptoms and prevents ventricular dilatation and heart failure (or, at least, it attenuates further progression of these abnormalities). Valve repair significantly improves clinical outcomes compared with valve replacement, reducing mortality by approximately 70%. Reverse LV remodelling after valve repair occurs in half of patients with functional MR. Percutaneous, catheter-based to mitral valve repair is a novel approach currently under clinical scrutiny, with encouraging preliminary results. This modality may provide a valuable alternative to mitral valve surgery, especially in critically ill patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Veteran endurance athletes have an increased risk of developing atrial fibrillation (AF), with a striking male predominance. We hypothesized that male athletes were more prone to atrial and ventricular remodeling and investigated the signal-averaged P wave and factors that promote the occurrence of AF. Nonelite athletes scheduled to participate in the 2010 Grand Prix of Bern, a 10-mile race, were invited. Of the 873 marathon and nonmarathon runners who were willing to participate, 68 female and 70 male athletes were randomly selected. The runners with cardiovascular disease or elevated blood pressure (>140/90 mm Hg) were excluded. Thus, 121 athletes were entered into the final analysis. Their mean age was 42 ± 7 years. No gender differences were found for age, lifetime training hours, or race time. The male athletes had a significantly longer signal-averaged P-wave duration (136 ± 12 vs 122 ± 10 ms; p <0.001). The left atrial volume was larger in the male athletes (56 ± 13 vs 49 ± 10 ml; p = 0.001), while left atrial volume index showed no differences (29 ± 7 vs 30 ± 6 ml/m²; p = 0.332). In male athletes, the left ventricular mass index (107 ± 17 vs 86 ± 16 g/m²; p <0.001) and relative wall thickness (0.44 ± 0.06 vs 0.41 ± 0.07; p = 0.004) were greater. No differences were found in the left ventricular ejection fraction (63 ± 4% vs 66 ± 6%; p = 0.112) and mitral annular tissue Doppler e' velocity (10.9 ± 1.5 vs 10.6 ± 1.5 cm/s; p = 0.187). However, the tissue Doppler a' velocity was higher (8.7 ± 1.2 vs 7.6 ± 1.3 cm/s; p < 0.001) in the male athletes. Male athletes had a higher systolic blood pressure at rest (123 ± 9 vs 110 ± 11 mm Hg; p < 0.001) and at peak exercise (180 ± 15 vs 169 ± 19 mm Hg; p = 0.001). In the frequency domain analysis of heart rate variability, the sympatho-vagal balance, represented by the low/high-frequency power ratio, was significantly greater in male athletes (5.8 ± 2.8 vs 3.9 ± 1.9; p < 0.001). Four athletes (3.3%) had at least one documented episode of paroxysmal AF, all were men (p = 0.042). In conclusion, for a comparable amount of training and performance, male athletes showed a more pronounced atrial remodeling, a concentric type of ventricular remodeling, and an altered diastolic function. A higher blood pressure at rest and during exercise and a higher sympathetic tone might be causal. The altered left atrial substrate might facilitate the occurrence of AF.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We describe the case of a 59-year-old man who had aortic regurgitation and a hypoplastic aortic valve and for whom an echocardiography evaluation revealed a vascular tumor in the roof of the left atrium, which was suspected to be a hemangioma. After undergoing preoperative invasive catheter coronary angiography, echocardiography, and multislice computed tomography examinations, the patient underwent an aortic miniroot replacement. Intraoperative findings confirmed the findings of the preoperative evaluations. The tumor, although macroscopically verified as a hemangioma, was not resected because of the tumor's position and size, and the threat of uncontrollable bleeding. After an uneventful postoperative clinical course, a subsequent successful transcatheter coil occlusion of the coronary fistula from the left circumflex coronary artery was performed as an alternative to surgical resection of the tumor. This case emphasizes the future role of a multimodality hybrid approach for diagnosis, planning (different 2- and 3-dimensional imaging modalities), and treatment in the form of combining interventional (transcatheter) and surgical (open heart) techniques, which could optimize different treatment strategies. This approach could be further improved by increasing the installations of hybrid operating rooms.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: To assess feasibility and outcomes of left atrial appendage (LAA) closure when using a patent foramen ovale (PFO) for left atrial access. Background: Because of the fear of entering the left atrium too high, using a PFO for left atrial access during LAA occlusion (LAAO) is generally discouraged. We report our single-center experience using a concomitant PFO for LAAO, thereby avoiding transseptal puncture. METHODS: LAAO was performed with local anesthesia and fluoroscopic guidance only (no echocardiography). The Amplatzer Cardiac Plug (ACP) was used in all patients. After LAAO, the PFO was closed at the same sitting, using an Amplatzer occluder through the ACP delivery sheath. Patients were discharged the same or the following day on dual antiplatelet therapy for 1-6 months, at which time a follow-up transesophageal echocardiogram (TEE) was performed. RESULTS: In 49 (96%) of 51 patients (35 males, age 70.9 ± 11.9 years), LAAO was successful using the PFO for left atrial access. In one patient, a long tunnel PFO precluded LAAO, which was performed via a more caudal transseptal puncture. In a second patient, a previously inserted ASD occluder precluded LAAO, which was abandoned because of pericardial bleeding. PFO closure was successful in all patients. Follow-up TEE was performed in 43 patients 138 ± 34 days after the procedure. It showed proper sitting of both devices in all patients. CONCLUSIONS: Using a PFO for LAAO had a high success rate and could be the default access in all patients with a PFO, potentially reducing procedural complications arising from transseptal puncture.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

UNLABELLED Topography of the esophagus in atrial fibrillation ablation. INTRODUCTION The close anatomic relationship of the posterior wall of the left atrium (LA) and the thermosensitive esophagus creates a potential hazard in catheter ablation procedures. METHODS AND RESULTS In 30 patients (pts) with atrial fibrillation (AF) undergoing catheter ablation, we prospectively studied the course and contact of the esophagus in relation to LA and the topographic proximity to ablation lines encircling the right-sided and left-sided pulmonary veins (PV) as well as to the posterior line connecting the encircling lines using the electromagnetic mapping system for reconstruction of LA and for tagging of the esophagus. This new technique of anatomic tagging of the esophagus was validated against the CT scan as a standard imaging procedure. The esophageal course was highly variable, extending from courses in direct vicinity to the left- or right-sided PV as well as in the midportion of the posterior LA. In order to avoid energy application in direct proximity to the esophagus, adjustments of the left and right PV encircling lines were necessary in 14/30 pts (47%) and 3/30 (10%). In 30 pts (100%), the mid- to inferior areas of the posterior LA revealed contact with the esophagus. Therefore, posterior and inferior linear ablation lines were abandoned and shifted to superior in 29 pts (97%). CONCLUSIONS Anatomic tagging of esophagus revealed a highly variable proximity to different areas of the posterior LA suggesting individual adjustment of encircling and linear ablation lines in AF ablation procedures to avoid the life threatening complication of esophagus perforation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Recently developed technologies allow aortic valve implantation off-pump in a beating heart. In this procedure, the native, stenotic aortic valve is not removed, but simply crushed by a pressure balloon mounted on a percutaneous catheter. Removal of the native aortic cusps before valve replacement may reduce the incidence of annular or cuspal calcium embolization and late perivalvular leaks and increase implantable valve size. However, a temporary valve system in the ascending aorta may be necessary to maintain hemodynamic stability by reducing acute aortic regurgitation and left ventricular volume overload. This study evaluates the hemodynamic effects of a wire-mounted, monoleaflet, temporary valve apparatus in a mechanical cardiovascular simulator. Aortic flow, systemic pressure and left ventricular pressure were continuously monitored. An intraluminal camera obtained real-time proximal and distal images of the valve in operation. Insertion of the parachute valve in the simulator increased diastolic pressure from 7 to 38 mm Hg. Cardiac output increased from 2.08 to 4.66 L/min and regurgitant volume decreased from 65 to 23 mL. In conclusion, placement of a temporary valve in the ascending aorta may help maintain hemodynamic stability and improve off-pump aortic valve replacement.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIMS Transcatheter mitral valve replacement (TMVR) is an emerging technology with the potential to treat patients with severe mitral regurgitation at excessive risk for surgical mitral valve surgery. Multimodal imaging of the mitral valvular complex and surrounding structures will be an important component for patient selection for TMVR. Our aim was to describe and evaluate a systematic multi-slice computed tomography (MSCT) image analysis methodology that provides measurements relevant for transcatheter mitral valve replacement. METHODS AND RESULTS A systematic step-by-step measurement methodology is described for structures of the mitral valvular complex including: the mitral valve annulus, left ventricle, left atrium, papillary muscles and left ventricular outflow tract. To evaluate reproducibility, two observers applied this methodology to a retrospective series of 49 cardiac MSCT scans in patients with heart failure and significant mitral regurgitation. For each of 25 geometrical metrics, we evaluated inter-observer difference and intra-class correlation. The inter-observer difference was below 10% and the intra-class correlation was above 0.81 for measurements of critical importance in the sizing of TMVR devices: the mitral valve annulus diameters, area, perimeter, the inter-trigone distance, and the aorto-mitral angle. CONCLUSIONS MSCT can provide measurements that are important for patient selection and sizing of TMVR devices. These measurements have excellent inter-observer reproducibility in patients with functional mitral regurgitation.