13 resultados para endotracheal tube cuff pressure

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE To study the hemodynamic effects of exogenously administered endothelin-1 (ET-1), a peptide produced by endothelial cells with potent non-adrenergically mediated vasoconstrictor properties. METHODS A prospective drug intervention study was carried out in a resuscitation research laboratory. Fifteen mixed-breed dogs were anesthetized and instrumented for hemodynamic monitoring. Asphyxia arrest was produced by clamping the endotracheal tube. Hemodynamic data were collected continuously. Following loss of aortic fluctuations monitored by thoracic aortic catheter, the animals remained in pulseless electrical activity (PEA) for 10 minutes. After 10 minutes of no-flow PEA, closed-chest CPR was begun and the animals were randomized to one of three treatment groups (EPI, 0.02 mg/kg epinephrine IV every 3 minutes; ENDO, 100 micrograms ET-1 IV at 0 minutes; and EPI/ENDO, a combination of the EPI and ENDO treatments). RESULTS ENDO and EPI alone produced similar coronary perfusion pressures (CPPs). The EPI/ENDO combination produced significantly improved CPP compared with that of either EPI or ENDO alone. In the EPI group, the best mean CPP was 16 +/- 14 mm Hg and occurred 7 minutes after drug administration. In the ENDO group, the best mean CPP was 28 +/- 7 mm Hg and occurred 13 minutes after drug administration. In the EPI/ENDO combination group, the best mean CPP was 61 +/- 37 mm Hg and occurred 7 minutes after drug administration (p < 0.05 compared with the EPI and ENDO groups alone). CONCLUSION ET-1 is a potent vasoconstrictor. The combination of EPI and ENDO significantly improved CPP compared with that for either agent alone. ET-1 should be investigated further as a vasoconstrictor in cardiac arrest.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Although postmortem imaging has gained prominence in the field of forensic medicine, evaluation of the postmortem lung remains problematic. Specifically, differentiation of normal postmortem changes and pathological pulmonary changes is challenging and at times impossible. In this study, five corpses were ventilated using a mechanical ventilator with a pressure of 40 mbar (40.8 cm H(2)O). The ventilation was performed via an endotracheal tube, a larynx mask or a continuous positive airway pressure mask. Postmortem computed tomographic images of the lungs before and with a ventilation of 40 mbar (40.8 cm H(2)O) were evaluated and the lung volumes were measured with segmentation software. Postmortem ventilation led to a clearly visible decrease of both the density in the dependant parts of the lungs and ground glass attenuation, whereas consolidated areas remained unchanged. Furthermore, a mean increase in the lung volume of 2.10 l was seen. Pathological changes such as septal thickening or pulmonary nodules in the lung parenchyma became more detectable with postmortem ventilation. Intracorporal postmortem mechanical ventilation of the lungs appears to be an effective method for enhancing detection of small pathologies of the lung parenchyma as well as for discriminating between consolidation, ground glass attenuation and position-dependent density.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Postmortem imaging has gained prominence in the field of forensic pathology. Even with experience in this procedure, difficulties arise in evaluating pathologies of the postmortem lung. The effect of postmortem ventilation with applied pressures of 10, 20, 30 and 40mbar was evaluated in 10 corpses using simultaneous postmortem computed tomography (pmCT) scans. Ventilation was performed via a continuous positive airway pressure mask (n=5), an endotracheal tube (n=4) and a laryngeal mask (n=1) using a portable home care ventilator. The lung volumes were measured and evaluated by a segmentation technique based on reconstructed CT data. The resulting changes to the lungs were analyzed. Postmortem ventilation at 40mbar induced a significant (p<0.05) unfolding of the lungs, with a mean volume increase of 1.32l. Small pathologies of the lung such as scarring and pulmonary nodules as well as emphysema were revealed, while inner livores were reduced. Even though lower ventilation pressures resulted in a significant (p<0.05) volume increase, pathologies were best evaluated when a pressure of 40mbar was applied, due to the greater reduction of the inner livores. With the ventilation-induced expansion of the lungs, a decrease in the heart diameter and gaseous distension of the stomach was recognized. In conclusion, postmortem ventilation is a feasible method for improving evaluation of the lungs and detection of small lung pathologies. This is because of the volume increase in the air-filled portions of the lung and reduced appearance of inner livores.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Percutaneous dilatational tracheostomy (PDT) is a frequently conducted procedure in critically ill patients. Bronchoscopic guidance of PDT is generally recommended to minimize the risk of unintentional tracheal injury. We present a case of tracheal tear and tension pneumothorax, a rare but potentially life-threatening complication, during continuously bronchoscopy-guided PDT. Sealing the large tracheal air fistula with the cuff of an endotracheal tube helped bridge time to definitive surgical repair in our patient. Bronchoscopic guidance may minimize, but cannot completely eliminate, the risk of tracheal injury during PDT.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: Neurally adjusted ventilatory assist uses the electrical activity of the diaphragm (EAdi)-a pneumatically-independent signal-to control the timing and pressure of the ventilation delivered, and should not be affected by leaks. The aim of this study was to evaluate whether NAVA can deliver assist in synchrony and proportionally to EAdi after extubation, with a leaky non-invasive interface. DESIGN AND SETTING: Prospective, controlled experimental study in an animal laboratory. ANIMALS: Ten rabbits, anesthetized, mechanically ventilated. INTERVENTIONS: Following lung injury, the following was performed in sequential order: (1) NAVA delivered via oral endotracheal tube with PEEP; (2) same as (1) without PEEP; (3) non-invasive NAVA at unchanged NAVA level and no PEEP via a single nasal prong; (4) no assist; (5) non-invasive NAVA at progressively increasing NAVA levels. MEASUREMENTS AND RESULTS: EAdi, esophageal pressure, blood gases and hemodynamics were measured during each condition. For the same NAVA level, the mean delivered pressure above PEEP increased from 3.9[Symbol: see text]+/-[Symbol: see text]1.4[Symbol: see text]cmH(2)O (intubated) to 7.5[Symbol: see text]+/-[Symbol: see text]3.8[Symbol: see text]cmH(2)O (non-invasive) (p[Symbol: see text]<[Symbol: see text]0.05) because of increased EAdi. No changes were observed in PaO(2) and PaCO(2). Increasing the NAVA level fourfold during non-invasive NAVA restored EAdi and esophageal pressure swings to pre-extubation levels. Triggering (106[Symbol: see text]+/-[Symbol: see text]20[Symbol: see text]ms) and cycling-off delays (40[Symbol: see text]+/-[Symbol: see text]21[Symbol: see text]ms) during intubation were minimal and not worsened by the leak (95[Symbol: see text]+/-[Symbol: see text]13[Symbol: see text]ms and 33[Symbol: see text]+/-[Symbol: see text]9[Symbol: see text]ms, respectively). CONCLUSION: NAVA can be effective in delivering non-invasive ventilation even when the interface with the patient is excessively leaky, and can unload the respiratory muscles while maintaining synchrony with the subject's demand.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Nebulized surfactant therapy has been proposed as an alternative method of surfactant administration. The use of a perforated vibrating membrane nebulizer provides a variety of advantages over conventional nebulizers. We investigated the molecular structure and integrity of poractant alfa pre- and post-nebulization. METHOD Curosurf® was nebulized using an Investigational eFlow® Nebulizer System. Non-nebulized surfactant ("NN"), recollected surfactant droplets from nebulization through an endotracheal tube ("NT") and nebulization of surfactant directly onto a surface ("ND") were investigated by transmission electron microscopy. Biophysical characteristics were assessed by the Langmuir-Wilhelmy balance and the Captive Bubble Surfactometer. RESULTS Volume densities of lamellar body-like forms (LBL) and multi-lamellar forms (ML) were high for "NN" and "NT" samples (38.8% vs. 47.7% for LBL and 58.2% vs. 47.8% for ML). In the "ND" sample, we found virtually no LBL's, ML's (72.6%) as well as uni-lamellar forms (16.4%) and a new structure, the "garland-like" forms (9.4%). Surface tension for "NN" and "NT" was 23.33 ± 0.29 and 25.77 ± 1.12 mN/m, respectively. Dynamic compression-expansion cycling minimum surface tensions were between 0.91 and 1.77 mN/m. CONCLUSION The similarity of surfactant characteristics of nebulized surfactant via a tube and the non-nebulized surfactant suggests that vibrating membrane nebulizers are suitable for surfactant nebulization. Alterations in surfactant morphology and characteristics after nebulization were transient. A new structural subtype of surfactant was identified. Pediatr Pulmonol. 2014; 49:348-356. © 2013 Wiley Periodicals, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

STUDY OBJECTIVE To determine the effectiveness of an esophageal doppler device to non-invasively detect experimental pseudo-electromechanical dissociation (pseudo-EMD). DESIGN Prospective, controlled, laboratory investigation using an asphyxial canine cardiac arrest model and a newly-developed esophageal flat-flow probe doppler unit. INTERVENTIONS Mongrel dogs (20) were instrumented for hemodynamic monitoring. The esophageal doppler probe was placed in the distal esophagus of each animal. Electromechanical dissociation (EMD) was induced by clamping the endotracheal tube. MEASUREMENTS AND MAIN RESULTS A period of pseudo-EMD was defined as the time where cardiac contractility was present, measured by a micromanometer tipped thoracic aortic catheter, without concurrent femoral pulses by palpation. The pseudo-EMD period could be produced consistently in all 20 animals. The characteristic doppler flow sounds were easily heard using the esophageal device in all animals. The time from endotracheal tube clamping until loss of femoral pulses was 622 +/- 96 s; until loss of radial artery doppler signals was 616 +/- 92 s; until loss of esophageal doppler signals was 728 +/- 88 s; and until loss of aortic fluctuations by thoracic aortic catheter was 728 +/- 82 s. The times to loss of esophageal doppler sounds and loss of aortic fluctuations were not significantly different. However, they were significantly longer than the time to loss of femoral pulses (P < 0.02). CONCLUSIONS The canine asphyxial EMD model can be used for short experimental studies of pseudo-EMD. Pseudo-EMD can be consistently and non-invasively detected with this esophageal doppler device. The device is as reliable as a micromanometer tipped aortic arch catheter in detecting pseudo-EMD. The doppler device could potentially be useful in improving recognition of near cardiac arrest in pre-hospital and emergency department settings. Further research on the utility of this device in other models of low-flow states should be performed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

ABSTRACT The authors describe two animals (one dog and one cat) that were presented with severe respiratory distress after trauma. Computerized tomographic imaging under general anesthesia revealed, in both cases, complete tracheal transection. Hypoxic episodes during anesthesia were relieved by keeping the endotracheal tube (ETT) positioned in the cranial part of the transected trachea and by allowing spontaneous breathing. Surgical preparation was performed quickly, and patients were kept in a sternal position to improve ventilation and oxygenation, and were only turned into dorsal recumbency shortly before surgical incision. A sterile ETT was guided into the distal part of the transected trachea by the surgeon, at which point mechanical ventilation was started. Both animals were successfully discharged from hospital a few days after surgery. Rapid and well-coordinated teamwork seemed to contribute to the good outcome. Precise planning and communication between anesthetists, surgeons, and technicians, as well as a quick course of action prior to correct ETT positioning helped to overcome critical phases.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION: This case report describes the anaesthetic management of exploratory thoracoscopy and alternating one lung ventilation (OLV) in a dog with a pulmonary bulla, and the application of continuous positive airway pressure (CPAP) to the non-ventilated lung for preventing and treating hypoxia. CASE HISTORY: A 6-year-old, male castrated Border collie was scheduled for exploratory thoracoscopy to investigate spontaneous pnemothorax that had not resolved with repeated suction. Specific requirements for the thoracoscopy were alternating OLV to allow the surgical access to the right middle lobe and its removal, and the examination of the left hemithorax to rule out the presence of other lesions. DIAGNOSIS AND MANAGEMENT: Selective lung ventilation was performed with a double lumen endobronchial tube (DLT), inserted under endoscopic guidance. After a short period of two lung ventilation during preparation of the surgical field, alternating OLV was performed, combining CPAP, provided to the non-ventilated lung via a Mapleson D breathing system, and positive end-expiratory pressure (PEEP) applied to the ventilated lung. Left OLV occurred first and resection of the right middle pulmonary lobe was successfully performed; right OLV followed to allow the examination of the left hemithorax. DISCUSSION AND CONCLUSIONS: The combination of CPAP and PEEP resulted in a satisfactory intra-operative management of hypoxemia. Alternating OLV can be performed successfully by using a DLT. CPAP, commonly employed in human medicine, should be considered an important tool in the anaesthetic management of OLV in small animals.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

After an uneventful general anesthesia, in a horse negative pressure pulmonary edema developed due to acute upper airway obstruction during the anesthetic recovery phase after colic surgery. No pathologic alteration of respiration was observed until the horse stood up and began suffocating. The horse had recovered with the nasogastric tube in situ. This, together with the postmortem diagnosis of laryngeal hemiplegia resulted in impairment of airflow through the larynx and development of pulmonary edema. Our objective is to alert clinicians about the possible hazard of recovery with an in-situ nasogastric tube.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: The single-use supraglottic airway devices LMA-Supreme (LMA-S; Laryngeal Mask Company, Henley-on-Thames, United Kingdom) and i-gel (Intersurgical Ltd, Wokingham, Berkshire, United Kingdom) have a second tube for gastric tube insertion. Only the LMA-S has an inflatable cuff. They have the same clinical indications and might be useful for difficult airway management. This prospective, crossover, randomized controlled trial was performed in a simulated difficult airway scenario using an extrication collar limiting mouth opening and neck movement. METHODS: Sixty patients were included. Both devices were placed in random order in each patient. Primary outcome was overall success rate. Other measurements were time to successful ventilation, airway leak pressure, fiberoptic glottic view, and adverse events. RESULTS: Success rate for the LMA-S was 95% versus 93% for the i-gel (P = 1.000). LMA-S needed shorter insertion time (34 +/- 12 s vs. 42 +/- 23 s, P = 0.024). Tidal volumes and airway leak pressure were similar (LMA-S 26 +/- 8 cm H20; i-gel 27 +/- 9 cm H20; P = 0.441). Fiberoptic view through the i-gel showed less epiglottic downfolding. Overall agreement in insertion outcome was 54 (successes) and 1 (failure) or 55 (92%) of 60 patients. The difference in success rate was 1.7% (95% CI -11.3% to 7.6%). CONCLUSIONS: Both airway devices had similar insertion success and clinical performance in the simulated difficult airway situation. The authors found less epiglottic downfolding and better fiberoptic view but longer insertion time with the i-gel. Our study shows that both devices are feasible for emergency airway management in patients with reduced neck movement and limited mouth opening.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Plant cell expansion is controlled by a fine-tuned balance between intracellular turgor pressure, cell wall loosening and cell wall biosynthesis. To understand these processes, it is important to gain in-depth knowledge of cell wall mechanics. Pollen tubes are tip-growing cells that provide an ideal system to study mechanical properties at the single cell level. With the available approaches it was not easy to measure important mechanical parameters of pollen tubes, such as the elasticity of the cell wall. We used a cellular force microscope (CFM) to measure the apparent stiffness of lily pollen tubes. In combination with a mechanical model based on the finite element method (FEM), this allowed us to calculate turgor pressure and cell wall elasticity, which we found to be around 0.3 MPa and 20–90 MPa, respectively. Furthermore, and in contrast to previous reports, we showed that the difference in stiffness between the pollen tube tip and the shank can be explained solely by the geometry of the pollen tube. CFM, in combination with an FEM-based model, provides a powerful method to evaluate important mechanical parameters of single, growing cells. Our findings indicate that the cell wall of growing pollen tubes has mechanical properties similar to rubber. This suggests that a fully turgid pollen tube is a relatively stiff, yet flexible cell that can react very quickly to obstacles or attractants by adjusting the direction of growth on its way through the female transmitting tissue.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Most medical implants run on batteries, which require costly and tedious replacement or recharging. It is believed that micro-generators utilizing intracorporeal energy could solve these problems. However, such generators do not, at this time, meet the energy requirements of medical implants.This paper highlights some essential aspects of designing and implementing a power source that scavenges energy from arterial expansion and contraction to operate an implanted medical device. After evaluating various potentially viable transduction mechanisms, the fabricated prototype employs an electromagnetic transduction mechanism. The artery is inserted into a laboratory-fabricated flexible coil which is permitted to freely deform in a magnetic field. This work also investigates the effects of the arterial wall's material properties on energy harvesting potential. For that purpose, two types of arteries (Penrose X-ray tube, which behave elastically, and an artery of a Göttinger minipig, which behaves viscoelastically) were tested. No noticeable difference could be observed between these two cases. For the pig artery, average harvestable power was 42 nW. Moreover, peak power was 2.38 μW. Both values are higher than those of the current state of the art (6 nW/16 nW). A theoretical modelling of the prototype was developed and compared to the experimental results.