7 resultados para electronic effects

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

60.00% 60.00%

Publicador:

Resumo:

We report a detailed physical analysis on a family of isolated, antiferro-magnetically (AF) coupled, chromium(III) finite chains, of general formula (Cr(RCO(2))(2)F)(n) where the chain length n = 6 or 7. Additionally, the chains are capped with a selection of possible terminating ligands, including hfac (= 1,1,1,5,5,5-hexafluoropentane-2,4-dionate(1-)), acac (= pentane-2,4-dionate(1-)) or (F)(3). Measurements by inelastic neutron scattering (INS), magnetometery and electron paramagnetic resonance (EPR) spectroscopy have been used to study how the electronic properties are affected by n and capping ligand type. These comparisons allowed the subtle electronic effects the choice of capping ligand makes for odd member spin 3/2 ground state and even membered spin 0 ground state chains to be investigated. For this investigation full characterisation of physical properties have been performed with spin Hamiltonian parameterisation, including the determination of Heisenberg exchange coupling constants and single ion axial and rhombic anisotropy. We reveal how the quantum spin energy levels of odd or even membered chains can be modified by the type of capping ligand terminating the chain. Choice of capping ligands enables Cr-Cr exchange coupling to be adjusted by 0, 4 or 24%, relative to Cr-Cr exchange coupling within the body of the chain, by the substitution of hfac, acac or (F)(3) capping ligands to the ends of the chain, respectively. The manipulation of quantum spin levels via ligands which play no role in super-exchange, is of general interest to the practise of spin Hamilton modelling, where such second order effects are generally not considered of relevance to magnetic properties.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Electronic tuning effects of substituents at the 4- and 8-positions of benzothiadiazole (BTD) within the fused tetrathiafulvalene–BTD donor–acceptor dyad have been studied. The electron acceptor strength of BTD is greatly increased by replacing Br with CN groups, extending the optical absorption of the small dyad into the near-IR region and importantly, the charge transport can be switched from p-type to ambipolar behaviour.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Four new tetrathiafulvalene (TTF)-based dyes featured with a donor–bridge–acceptor (D–π–A) structure were synthesized and characterized. All of them undergo two reversible oxidations to form stable radical cation and dication species. The electronic interactions between the TTF donor and the cyanoacrylic acid acceptor through the different π-linkers have been demonstrated by the presence of a photo-induced intramolecular charge-transfer (ICT) absorption band in the visible region. A red shift of the ICT state can be finely tuned by the degree of aromaticity and extended conjugation of π-bridges. To some extent, the oxidation potentials of these dyes are affected by the nature of π-bridges. They have been applied in organic dye-sensitized solar cells, showing relatively low power conversion efficiencies of up to 0.87% due to substantial charge recombination losses.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To determine the effect of glucosamine, chondroitin, or the two in combination on joint pain and on radiological progression of disease in osteoarthritis of the hip or knee. Design Network meta-analysis. Direct comparisons within trials were combined with indirect evidence from other trials by using a Bayesian model that allowed the synthesis of multiple time points. MAIN OUTCOME MEASURE: Pain intensity. Secondary outcome was change in minimal width of joint space. The minimal clinically important difference between preparations and placebo was prespecified at -0.9 cm on a 10 cm visual analogue scale. DATA SOURCES: Electronic databases and conference proceedings from inception to June 2009, expert contact, relevant websites. Eligibility criteria for selecting studies Large scale randomised controlled trials in more than 200 patients with osteoarthritis of the knee or hip that compared glucosamine, chondroitin, or their combination with placebo or head to head. Results 10 trials in 3803 patients were included. On a 10 cm visual analogue scale the overall difference in pain intensity compared with placebo was -0.4 cm (95% credible interval -0.7 to -0.1 cm) for glucosamine, -0.3 cm (-0.7 to 0.0 cm) for chondroitin, and -0.5 cm (-0.9 to 0.0 cm) for the combination. For none of the estimates did the 95% credible intervals cross the boundary of the minimal clinically important difference. Industry independent trials showed smaller effects than commercially funded trials (P=0.02 for interaction). The differences in changes in minimal width of joint space were all minute, with 95% credible intervals overlapping zero. Conclusions Compared with placebo, glucosamine, chondroitin, and their combination do not reduce joint pain or have an impact on narrowing of joint space. Health authorities and health insurers should not cover the costs of these preparations, and new prescriptions to patients who have not received treatment should be discouraged.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose:  Most recently light and mobile reading devices with high display resolutions have become popular and they may open new possibilities for reading applications in education, business and the private sector. The ability to adapt font size may also open new reading opportunities for people with impaired or low vision. Based on their display technology two major groups of reading devices can be distinguished. One type, predominantly found in dedicated e-book readers, uses electronic paper also known as e-Ink. Other devices, mostly multifunction tablet-PCs, are equipped with backlit LCD displays. While it has long been accepted that reading on electronic displays is slow and associated with visual fatigue, this new generation is explicitly promoted for reading. Since research has shown that, compared to reading on electronic displays, reading on paper is faster and requires fewer fixations per line, one would expect differential effects when comparing reading behaviour on e-Ink and LCD. In the present study we therefore compared experimentally how these two display types are suited for reading over an extended period of time. Methods:  Participants read for several hours on either e-Ink or LCD, and different measures of reading behaviour and visual strain were regularly recorded. These dependent measures included subjective (visual) fatigue, a letter search task, reading speed, oculomotor behaviour and the pupillary light reflex. Results:  Results suggested that reading on the two display types is very similar in terms of both subjective and objective measures. Conclusions:  It is not the technology itself, but rather the image quality that seems crucial for reading. Compared to the visual display units used in the previous few decades, these more recent electronic displays allow for good and comfortable reading, even for extended periods of time.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background:Erythropoiesis-stimulating agents (ESAs) reduce the need for red blood cell transfusions; however, they increase the risk of thromboembolic events and mortality. The impact of ESAs on quality of life (QoL) is controversial and led to different recommendations of medical societies and authorities in the USA and Europe. We aimed to critically evaluate and quantify the effects of ESAs on QoL in cancer patients.Methods:We included data from randomised controlled trials (RCTs) on the effects of ESAs on QoL in cancer patients. Randomised controlled trials were identified by searching electronic data bases and other sources up to January 2011. To reduce publication and outcome reporting biases, we included unreported results from clinical study reports. We conducted meta-analyses on fatigue- and anaemia-related symptoms measured with the Functional Assessment of Cancer Therapy-Fatigue (FACT-F) and FACT-Anaemia (FACT-An) subscales (primary outcomes) or other validated instruments.Results:We identified 58 eligible RCTs. Clinical study reports were available for 27% (4 out of 15) of the investigator-initiated trials and 95% (41 out of 43) of the industry-initiated trials. We excluded 21 RTCs as we could not use their QoL data for meta-analyses, either because of incomplete reporting (17 RCTs) or because of premature closure of the trial (4 RCTs). We included 37 RCTs with 10 581 patients; 21 RCTs were placebo controlled. Chemotherapy was given in 27 of the 37 RCTs. The median baseline haemoglobin (Hb) level was 10.1 g dl(-1); in 8 studies ESAs were stopped at Hb levels below 13 g dl(-1) and in 27 above 13 g dl(-1). For FACT-F, the mean difference (MD) was 2.41 (95% confidence interval (95% CI) 1.39-3.43; P<0.0001; 23 studies, n=6108) in all cancer patients and 2.81 (95% CI 1.73-3.90; P<0.0001; 19 RCTs, n=4697) in patients receiving chemotherapy, which was below the threshold (⩾3) for a clinically important difference (CID). Erythropoiesis-stimulating agents had a positive effect on anaemia-related symptoms (MD 4.09; 95% CI 2.37-5.80; P=0.001; 14 studies, n=2765) in all cancer patients and 4.50 (95% CI 2.55-6.45; P<0.0001; 11 RCTs, n=2436) in patients receiving chemotherapy, which was above the threshold (⩾4) for a CID. Of note, this effect persisted when we restricted the analysis to placebo-controlled RCTs in patients receiving chemotherapy. There was some evidence that the MDs for FACT-F were above the threshold for a CID in RCTs including cancer patients receiving chemotherapy with Hb levels below 12 g dl(-1) at baseline and in RCTs stopping ESAs at Hb levels above 13 g dl(-1). However, these findings for FACT-F were not confirmed when we restricted the analysis to placebo-controlled RCTs in patients receiving chemotherapy.Conclusions:In cancer patients, particularly those receiving chemotherapy, we found that ESAs provide a small but clinically important improvement in anaemia-related symptoms (FACT-An). For fatigue-related symptoms (FACT-F), the overall effect did not reach the threshold for a CID.British Journal of Cancer advance online publication, 17 April 2014; doi:10.1038/bjc.2014.171 www.bjcancer.com.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE To systematically appraise whether anti-infective protocols are effective in preventing biologic implant complications and implant loss after a mean observation period ≥ 10 years after loading. MATERIALS AND METHODS An electronic search of Medline via PubMed and Embase via Ovid databases complemented by manual search was conducted up to October 31, 2012. Studies were included provided that they were published in English, German, French, or Italian, and conducted on ≥ 20 partially and fully edentulous patients with dental implants and regular (≥ 1×/year) supportive periodontal therapy (SPT) over a mean observation period ≥ 10 years. Assessment of the identified studies and data extraction were performed independently by two reviewers. Authors were contacted if required. Collected data were reported by descriptive methods. RESULTS The initial electronic search resulted in the identification of 994 titles from Medline via PubMed and 531 titles from Embase via Ovid databases, respectively. After elimination of duplicate titles and exclusion of 60 full-text articles, 143 articles were analyzed, resulting in 15 studies eligible for qualitative analysis. The implant survival rate ranged from 85.7% to 99.2% after a mean observation period ≥ 10 years. One comparative study assessed the effects of regular SPT on the occurrence of biologic complications and implant loss. Overall, regular diagnosis and implementation of anti-infective therapeutic protocols were effective in the management of biological complications and prevention of implant loss. Residual probing depths at the end of active periodontal therapy and development of reinfection during supportive periodontal therapy (SPT) represented a significant risk for the onset of peri-implantitis and implant loss. Comparative studies indicated that implant survival and success rates were lower in periodontally compromised vs noncompromised patients. CONCLUSIONS In order to achieve high long-term survival and success rates of dental implants and their restorations, enrollment in regular SPT including anti-infective preventive measures should be implemented. Therapy of peri-implant mucositis should be considered as a preventive measure for the onset of peri-implantitis. Completion of active periodontal therapy should precede implant placement in periodontally compromised patients.