Resumo:
We report the case of a woman with syncope and persistently prolonged QTc interval. Screening of congenital long QT syndrome (LQTS) genes revealed that she was a heterozygous carrier of a novel KCNH2 mutation, c.G238C. Electrophysiological and biochemical characterizations unveiled the pathogenicity of this new mutation, displaying a 2-fold reduction in protein expression and current density due to a maturation/trafficking-deficient mechanism. The patient's phenotype can be fully explained by this observation. This study illustrates the importance of performing genetic analyses and mutation characterization when there is a suspicion of congenital LQTS. Identifying mutations in the PAS domain or other domains of the hERG1 channel and understanding their effect may provide more focused and mutation-specific risk assessment in this population.
Resumo:
BACKGROUND: Elevated plasma fibrinogen levels have prospectively been associated with an increased risk of coronary artery disease in different populations. Plasma fibrinogen is a measure of systemic inflammation crucially involved in atherosclerosis. The vagus nerve curtails inflammation via a cholinergic antiinflammatory pathway. We hypothesized that lower vagal control of the heart relates to higher plasma fibrinogen levels. METHODS: Study participants were 559 employees (age 17-63 years; 89% men) of an airplane manufacturing plant in southern Germany. All subjects underwent medical examination, blood sampling, and 24-hour ambulatory heart rate recording while kept on their work routine. The root mean square of successive differences in RR intervals during the night period (nighttime RMSSD) was computed as the heart rate variability index of vagal function. RESULTS: After controlling for demographic, lifestyle, and medical factors, nighttime RMSSD explained 1.7% (P = 0.001), 0.8% (P = 0.033), and 7.8% (P = 0.007), respectively, of the variance in fibrinogen levels in all subjects, men, and women. Nighttime RMSSD and fibrinogen levels were stronger correlated in women than in men. In all workers, men, and women, respectively, there was a mean +/- SEM increase of 0.41 +/- 0.13 mg/dL, 0.28 +/- 0.13 mg/dL, and 1.16 +/- 0.41 mg/dL fibrinogen for each millisecond decrease in nighttime RMSSD. CONCLUSIONS: Reduced vagal outflow to the heart correlated with elevated plasma fibrinogen levels independent of the established cardiovascular risk factors. This relationship seemed comparably stronger in women than men. Such an autonomic mechanism might contribute to the atherosclerotic process and its thrombotic complications.
The optimal lead insertion depth for esophageal ECG recordings with respect to atrial signal quality
Resumo:
BACKGROUND Diagnosing supraventricular arrhythmias by conventional long-term ECG can be cumbersome because of poor p-waves. Esophageal long-term electrocardiography (eECG) has an excellent sensitivity for atrial signals and may overcome this limitation. However, the optimal lead insertion depth (OLID) is not known. METHODS We registered eECGs at different lead insertion depths in 27 patients and analyzed 199,716 atrial complexes with respect to signal amplitude and slope. Correlation and regression analyses were used to find a criterion for OLID. RESULTS Atrial signal amplitudes and slopes significantly depend on lead insertion depth. OLID correlates with body height (rSpearman=0.71) and can be estimated by OLID [cm]=0.25*body height[cm]-7cm. At this insertion depth, we recorded the largest esophageal atrial signal amplitudes (1.27±0.86mV), which were much larger compared to conventional surface lead II (0.19±0.10mV, p<0.0001). CONCLUSION The OLID depends on body height and can be calculated by a simple regression formula.
Resumo:
Background: Ischemia monitoring cannot always be performed by 12-lead ECG. Hence, the individual performance of the ECG leads is crucial. No experimental data on the ECG's specificity for transient ischemia exist. Methods: In 45 patients a 19-lead ECG was registered during a 1-minute balloon occlusion of a coronary artery (left anterior descending artery [LAD], right coronary artery [RCA] or left circumflex artery [LCX]). ST-segment shifts and sensitivity/specificity of the leads were measured. Results: During LAD occlusion, V3 showed maximal ST-segment elevation (0.26 mV [IQR 0.16–0.33 mV], p = 0.001) and sensitivity/specificity (88% and 80%). During RCA occlusion, III showed maximal ST-elevation (0.2 mV [IQR 0.09–0.26 mV], p = 0.004), aVF had the best sensitivity/specificity (85% and 68%). During LCX occlusion, V6 showed maximal ST-segment elevation (0.04 mV [IQR 0.02–0.14 mV], p = 0.005), and sensitivity/specificity was (31%/92%) but could be improved (63%/72%) using an optimized cut-off for ischemia. Conclusion: V3, aVF and V6 show the best performance to detect transient ischemia.
Resumo:
BACKGROUND: Several parameters of heart rate variability (HRV) have been shown to predict the risk of sudden cardiac death (SCD) in cardiac patients. There is consensus that risk prediction is increased when measuring HRV during specific provocations such as orthostatic challenge. For the first time, we provide data on reproducibility of such a test in patients with a history of acute coronary syndrome. METHODS: Sixty male patients (65+/-8years) with a history of acute coronary syndrome on stable medication were included. HRV was measured in supine (5min) and standing (5min) position on 2 occasions separated by two weeks. For risk assessment relevant time-domain [standard deviation of all R-R intervals (SDNN) and root mean squared standard differences between adjacent R-R intervals (RMSSD)], frequency domain [low-frequency power (LF), high-frequency power (HF) and LF/HF power ratio] and short-term fractal scaling component (DF1) were computed. Absolute reproducibility was assessed with the standard errors of the mean (SEM) and 95% limits of random variation, and relative reproducibility by the intraclass correlation coefficient (ICC). RESULTS: We found comparable SEMs and ICCs in supine position and after an orthostatic challenge test. All ICCs were good to excellent (ICCs between 0.636 and 0.869). CONCLUSIONS: Reproducibility of HRV parameters during orthostatic challenge is good and comparable with supine position.
Resumo:
OBJECTIVE Abnormal ECG findings suggestive of cardiac disease are frequent in patients with funnel chest, although structural heart disease is rare. Electrocardiographic characteristics and changes following new surgical treatments in young adults are not described so far. The aim of the study was to analyze electrocardiographic characteristics of patients with funnel chest before and after minimally invasive funnel chest correction by the Nuss procedure. METHODS Twenty-six patients with surgical correction of funnel chest using pectus bar were included. Twelve-lead ECGs before and later than one year after surgery were analyzed. RESULTS In postoperative ECGs, amplitude of P wave in lead II and negative terminal amplitude of P wave in lead V1 decreased from 0.13 to 0.10mV (p=0.03), and from 0.10 to 0.04mV (p<0.001), respectively. Mean QRS duration decreased from 108ms to 98ms (p=0.003) after correction. A pathological left and right Sokolow-Lyon index was observed in 35% and 23% of patients before, versus 8% (p=0.04) and 0% (p=0.01) after correction, respectively. In contrast, the rate of patients with J wave pattern in precordial leads V4-V6 increased from 8% before to 42% after surgery (p=0.004). CONCLUSIONS ECG abnormalities in patients with funnel chest are frequent, and can normalize after surgical correction by the Nuss procedure. De novo J wave pattern in precordial leads V4-V6 is a frequent finding after surgical funnel chest correction using pectus bar.
Resumo:
PURPOSE Paroxysmal atrial fibrillation (PAF) often remains undiagnosed. Long-term surface ECG is used for screening, but has limitations. Esophageal ECG (eECG) allows recording high quality atrial signals, which were used to identify markers for PAF. METHODS In 50 patients (25 patients with PAF; 25 controls) an eECG and surface ECG was recorded simultaneously. Partially A-V blocked atrial runs (PBARs) were quantified, atrial signal duration in eECG was measured. RESULTS eECG revealed 1.8‰ of atrial premature beats in patients with known PAF to be PBARs with a median duration of 853ms (interquartile range (IQR) 813-1836ms) and a median atrial cycle length of 366ms (IQR 282-432ms). Even during a short recording duration of 2.1h (IQR 1.2-17.2h), PBARs occurred in 20% of PAF patients but not in controls (p=0.05). Left atrial signal duration was predictive for PAF (72% sensitivity, 80% specificity). CONCLUSIONS eECG reveals partially blocked atrial runs and prolonged left atrial signal duration - two novel surrogate markers for PAF.