14 resultados para ease of discovery

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the ease of application of two-piece, graduated, compression systems for the treatment of venous ulcers. METHODS: Four kits used to provide limb compression in the management of venous ulcers were evaluated. These have been proven to be non-inferior to various types of bandages in clinical trials. The interface pressure exerted above the ankle by the under-stocking and the complete compression system and the force required to pull the over-stocking off were assessed in vitro. Ease of application of the four kits was evaluated in four sessions by five nurses who put stockings on their own legs in a blinded manner. They expressed their assessment of the stockings using a series of visual analogue scales (VASs). RESULTS: The Sigvaris Ulcer X((R)) kit provided a mean interface pressure of 46 mmHg and required a force in the range of 60-90 N to remove it. The Mediven((R)) ulcer kit exerted the same pressure but required force in the range of 150-190 N to remove it. Two kits (SurePress((R)) Comfort and VenoTrain((R)) Ulcertec) exerted a mean pressure of only 25 mmHg and needed a force in the range of 100-160 N to remove them. Nurses judged the Ulcer X and SurePress kits easiest to apply. Application of the VenoTrain kit was found slightly more difficult. The Mediven kit was judged to be difficult to use. CONCLUSIONS: Comparison of ease of application of compression-stocking kits in normal legs revealed marked differences between them. Only one system exerted a high pressure and was easy to apply. Direct comparison of these compression kits in leg-ulcer patients is required to assess whether our laboratory findings correlate with patient compliance and ulcer healing.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Two major difficulties arise when taking blood samples in children: the challenge of venous access and the comparatively large amount of blood required.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present study investigated how ease of imagery influences source monitoring accuracy. Two experiments were conducted in order to examine how ease of imagery influences the probability of source confusions of perceived and imagined completions of natural symmetric shapes. The stimuli consisted of binary pictures of natural objects, namely symmetric pictures of birds, butterflies, insects, and leaves. The ease of imagery (indicating the similarity of the sources) and the discriminability (indicating the similarity of the items) of each stimulus were estimated in a pretest and included as predictors of the memory performance for these stimuli. It was found that confusion of the sources becomes more likely when the imagery process was relatively easy. However, if the different processes of source monitoring-item memory, source memory and guessing biases-are disentangled, both experiments support the assumption that the effect of decreased source memory for easily imagined stimuli is due to decision processes and misinformation at retrieval rather than encoding processes and memory retention. The data were modeled with a Bayesian hierarchical implementation of the one high threshold source monitoring model.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Because the recommendation to use flowables for posterior restorations is still a matter of debate, the objective of this study was to determine in a nationwide survey in Germany how frequently, for what indications, and for what reasons, German dentists use flowable composites in posterior teeth. In addition, the acceptance of a simplified filling technique for posterior restorations using a low stress flowable composite was evaluated. Completed questionnaires from all over Germany were returned by 1,449 dentists resulting in a response rate of 48.5%; 78.6% of whom regularly used flowable composites for posterior restorations. The most frequent indications were cavity lining (80.1%) and small Class I fillings (74.2%). Flowables were less frequently used for small Class II fillings (22.7%) or other indications (13.6%). Most frequent reasons given for the use of flowables in posterior teeth were the prevention of voids (71.7%) and superior adaptation to cavity walls (72.9%), whereas saving time was considered less important (13.8%). Based on the subjective opinion of the dentists the simplified filling technique seemed to deliver advantages compared to the methods used to date particularly with regard to good cavity adaptation and ease of use. In conclusion, resin composites are the standard material type used for posterior restorations by general dental practitioners in Germany and most dentists use flowable composites as liners.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND Recommendations from international task forces on geriatric assessment emphasize the need for research including validation of cancer-specific geriatric assessment (C-SGA) tools in oncological settings. The objective of this study was to evaluate the feasibility of the SAKK Cancer-Specific Geriatric Assessment (C-SGA) in clinical practice. METHODS A cross sectional study of cancer patients >=65 years old (N = 51) with pathologically confirmed cancer presenting for initiation of chemotherapy treatment (07/01/2009-03/31/2011) at two oncology departments in Swiss canton hospitals: Kantonsspital Graubunden (KSGR N = 25), Kantonsspital St. Gallen (KSSG N = 26). Data was collected using three instruments, the SAKK C-SGA plus physician and patient evaluation forms. The SAKK C-SGA includes six measures covering five geriatric assessment domains (comorbidity, function, psychosocial, nutrition, cognition) using a mix of medical record abstraction (MRA) and patient interview. Five individual domains and one overall SAKK C-SGA score were calculated and dichotomized as below/above literature-based cut-offs. The SAKK C-SGA was evaluated by: patient and physician estimated time to complete, ease of completing, and difficult or unanswered questions. RESULTS Time to complete the patient questionnaire was considered acceptable by almost all (>=96%) patients and physicians. Patients reported slightly shorter times to complete the questionnaire than physicians (17.33 +/- 7.34 vs. 20.59 +/- 6.53 minutes, p = 0.02). Both groups rated the patient questionnaire as easy/fairly easy to complete (91% vs. 84% respectively, p = 0.14) with few difficult or unanswered questions. The MRA took on average 8.32 +/- 4.72 minutes to complete. Physicians (100%) considered time to complete MRA acceptable, 96% rated it as easy/fairly easy to complete. Individual study site populations differed on health-related characteristics (excellent/good physician-rated general health KSGR 71% vs. KSSG 32%, p = 0.007). The overall mean C-SGA score was 2.4 +/- 1.12. Patients at KSGR had lower C-SGA scores (2.00 +/- 1.19 vs. 2.81 +/- 0.90, p = 0.009) and a smaller proportion (28% vs.65%, p = 0.008) was above the C-SGA cut-off score compared to KSSG. CONCLUSIONS These results suggest the SAKK C-SGA is a feasible practical tool for use in clinical practice. It demonstrated discriminative ability based on objective geriatric assessment measures, but additional investigations on use for clinical decision-making are warranted. The SAKK C-SGA also provides important usable domain information for intervention to optimize outcomes in older cancer patients.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The ectoparasitic mite Varroa destructor acting as a virus vector constitutes a central mechanism for losses of managed honey bee, Apis mellifera, colonies. This creates demand for an easy, accurate and cheap diagnostic tool to estimate the impact of viruliferous mites in the field. Here we evaluated whether the clinical signs of the ubiquitous and mite-transmitted deformed wing virus (DWV) can be predictive markers of winter losses. In fall and winter 2007/2008, A.m. carnica workers with apparent wing deformities were counted daily in traps installed on 29 queenright colonies. The data show that colonies which later died had a significantly higher proportion of workers with wing deformities than did those which survived. There was a significant positive correlation between V. destructor infestation levels and the number of workers displaying DWV clinical signs, further supporting the mite's impact on virus infections at the colony level. A logistic regression model suggests that colony size, the number of workers with wing deformities and V. destructor infestation levels constitute predictive markers for winter colony losses in this order of importance and ease of evaluation.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Discrepancies in finite-element model predictions of bone strength may be attributed to the simplified modeling of bone as an isotropic structure due to the resolution limitations of clinical-level Computed Tomography (CT) data. The aim of this study is to calculate the preferential orientations of bone (the principal directions) and the extent to which bone is deposited more in one direction compared to another (degree of anisotropy). Using 100 femoral trabecular samples, the principal directions and degree of anisotropy were calculated with a Gradient Structure Tensor (GST) and a Sobel Structure Tensor (SST) using clinical-level CT. The results were compared against those calculated with the gold standard Mean-Intercept-Length (MIL) fabric tensor using micro-CT. There was no significant difference between the GST and SST in the calculation of the main principal direction (median error=28°), and the error was inversely correlated to the degree of transverse isotropy (r=−0.34, p<0.01). The degree of anisotropy measured using the structure tensors was weakly correlated with the MIL-based measurements (r=0.2, p<0.001). Combining the principal directions with the degree of anisotropy resulted in a significant increase in the correlation of the tensor distributions (r=0.79, p<0.001). Both structure tensors were robust against simulated noise, kernel sizes, and bone volume fraction. We recommend the use of the GST because of its computational efficiency and ease of implementation. This methodology has the promise to predict the structural anisotropy of bone in areas with a high degree of anisotropy, and may improve the in vivo characterization of bone.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Both deepening sleep and evolving epileptic seizures are associated with increasing slow-wave activity. Larger-scale functional networks derived from electroencephalogram indicate that in both transitions dramatic changes of communication between brain areas occur. During seizures these changes seem to be 'condensed', because they evolve more rapidly than during deepening sleep. Here we set out to assess quantitatively functional network dynamics derived from electroencephalogram signals during seizures and normal sleep. Functional networks were derived from electroencephalogram signals from wakefulness, light and deep sleep of 12 volunteers, and from pre-seizure, seizure and post-seizure time periods of 10 patients suffering from focal onset pharmaco-resistant epilepsy. Nodes of the functional network represented electrical signals recorded by single electrodes and were linked if there was non-random cross-correlation between the two corresponding electroencephalogram signals. Network dynamics were then characterized by the evolution of global efficiency, which measures ease of information transmission. Global efficiency was compared with relative delta power. Global efficiency significantly decreased both between light and deep sleep, and between pre-seizure, seizure and post-seizure time periods. The decrease of global efficiency was due to a loss of functional links. While global efficiency decreased significantly, relative delta power increased except between the time periods wakefulness and light sleep, and pre-seizure and seizure. Our results demonstrate that both epileptic seizures and deepening sleep are characterized by dramatic fragmentation of larger-scale functional networks, and further support the similarities between sleep and seizures.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND The majority of radiological reports are lacking a standard structure. Even within a specialized area of radiology, each report has its individual structure with regards to details and order, often containing too much of non-relevant information the referring physician is not interested in. For gathering relevant clinical key parameters in an efficient way or to support long-term therapy monitoring, structured reporting might be advantageous. OBJECTIVE Despite of new technologies in medical information systems, medical reporting is still not dynamic. To improve the quality of communication in radiology reports, a new structured reporting system was developed for abdominal aortic aneurysms (AAA), intended to enhance professional communication by providing the pertinent clinical information in a predefined standard. METHODS Actual state analysis was performed within the departments of radiology and vascular surgery by developing a Technology Acceptance Model. The SWOT (strengths, weaknesses, opportunities, and threats) analysis focused on optimization of the radiology reporting of patients with AAA. Definition of clinical parameters was achieved by interviewing experienced clinicians in radiology and vascular surgery. For evaluation, a focus group (4 radiologists) looked at the reports of 16 patients. The usability and reliability of the method was validated in a real-world test environment in the field of radiology. RESULTS A Web-based application for radiological "structured reporting" (SR) was successfully standardized for AAA. Its organization comprises three main categories: characteristics of pathology and adjacent anatomy, measurements, and additional findings. Using different graphical widgets (eg, drop-down menus) in each category facilitate predefined data entries. Measurement parameters shown in a diagram can be defined for clinical monitoring and be adducted for quick adjudications. Figures for optional use to guide and standardize the reporting are embedded. Analysis of variance shows decreased average time required with SR to obtain a radiological report compared to free-text reporting (P=.0001). Questionnaire responses confirm a high acceptance rate by the user. CONCLUSIONS The new SR system may support efficient radiological reporting for initial diagnosis and follow-up for AAA. Perceived advantages of our SR platform are ease of use, which may lead to more accurate decision support. The new system is open to communicate not only with clinical partners but also with Radiology Information and Hospital Information Systems.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Prevention and treatment of intraoperative hypoxemia in horses is difficult and both efficacy and safety of therapeutic maneuvers have to be taken into account. Inhaled salbutamol has been suggested as treatment of hypoxia in horses during general anesthesia, due to safety and ease of the technique. The present report describes the occurrence of clinically relevant unwanted cardiovascular effects (i.e. tachycardia and blood pressure modifications) in 5 horses undergoing general anesthesia in dorsal recumbency after salbutamol inhalation. Balanced anesthesia based on inhalation of isoflurane in oxygen or oxygen and air and continuous rate infusion (CRI) of lidocaine, romifidine, or combination of lidocaine and guaifenesine and ketamine was provided. Supportive measures were necessary to restore normal cardiovascular function in all horses but no long-term adverse effects were noticed in any of the cases.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

INTRODUCTION Though developed for thoracic insufficiency syndrome, the spinal growth-stimulating potential and the ease of placement of vertical expandable titanium ribs (VEPTRs) has resulted in their widespread use for early-onset spine deformity. Observation of implant-related ossifications warrants further assessment, since they may be detrimental to the function-preserving non-fusion strategy. PATIENTS AND METHODS Radiographs (obtained pre and post index procedure, and at 4-year follow-up) and the records of 65 VEPTR patients from four paediatric spine centres were analysed. Ossifications were classified as type I (at anchor points), type II (along the central part) or type III (re-ossification after thoracostomy). RESULTS The average age at the index procedure was 6.5 years (min 1, max 13.7). The most prevalent spine problem was congenital scoliosis (37) with rib fusions (34), followed by neuromuscular and syndromic deformities (13 and 8, respectively). Idiopathic and secondary scoliosis (e.g. after thoracotomy) were less frequent (3 and 4, respectively). Forty-two of the 65 (65 %) patients showed ossifications, half of which were around the anchors. Forty-five percent (15/33) without pre-existing rib fusions developed a type II ossification along the implant. Re-ossifications of thoracostomies were less frequent (5/34, 15 %). The occurrence of ossifications was not associated with patient-specific factors. CONCLUSIONS Implant-related ossifications around VEPTR are common. In contrast to harmless bone formation around anchors, ossifications around the telescopic part and the rod section are troublesome in view of their possible negative impact on chest cage compliance and spinal mobility. This potential side effect needs to be considered during implant selection, particularly in patients with originally normal thoracic and spinal anatomy.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

River bedload surveyed at 50 sites in Westland is dominated by Alpine Schist or Torlesse Greywacke from the Alpine Fault hanging wall, with subordinate Pounamu Ultramafics or footwall-derived Western Province rocks. Tumbling experiments found ultramafics to have the lowest attrition rates, compared with greywacke sandstone and granite (which abrade to produce silt to medium-sand), or incompetent schist (which fragments). Arahura has greater total concentrations (103–105 t/km2) and proportions (5–40%) of ultramafic bedload compared with Hokitika and Taramakau catchments (101–104 t/km2, mostly <10%), matching relative areas of mapped Pounamu Ultramafic bedrock, but enriched relative to absolute areal proportions. Western Province rocks downthrown by the Alpine Fault are under-represented in the bedload. Enriched concentrations of ultramafic bedload decrease rapidly with distance downstream from source rock outcrops, changing near prominent ice-limit moraines. Bedload evolution with transport involves both downstream fining and dilution from tributaries, in a sediment supply regime more strongly influenced by tectonics and the imprint of past glaciation. Treasured New Zealand pounamu (jade) is associated with ultramafic rocks. Chances of discovery vary between catchments, are increased near glacial moraines, and are highest near source-rock outcrops in remote mountain headwaters.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The use of infrared thermography for the identification of lameness in cattle has increased in recent years largely because of its non-invasive properties, ease of automation and continued cost reductions. Thermography can be used to identify and determine thermal abnormalities in animals by characterizing an increase or decrease in the surface temperature of their skin. The variation in superficial thermal patterns resulting from changes in blood flow in particular can be used to detect inflammation or injury associated with conditions such as foot lesions. Thermography has been used not only as a diagnostic tool, but also to evaluate routine farm management. Since 2000, 14 peer reviewed papers which discuss the assessment of thermography to identify and manage lameness in cattle have been published. There was a large difference in thermography performance in these reported studies. However, thermography was demonstrated to have utility for the detection of contralateral temperature difference and maximum foot temperature on areas of interest. Also apparent in these publications was that a controlled environment is an important issue that should be considered before image scanning.