71 resultados para correlation coefficients

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

There is a growing concern by regulatory authorities for the selection of antibiotic resistance caused by the use of biocidal products. We aimed to complete the detailed information on large surveys by investigating the relationship between biocide and antibiotic susceptibility profiles of a large number of Staphylococcus aureus isolates using four biocides and antibiotics commonly used in clinical practice. The minimal inhibitory concentration (MIC) for most clinically-relevant antibiotics was determined according to the standardized methodology for over 1600 clinical S. aureus isolates and compared to susceptibility profiles of benzalkonium chloride, chlorhexidine, triclosan, and sodium hypochlorite. The relationship between antibiotic and biocide susceptibility profiles was evaluated using non-linear correlations. The main outcome evidenced was an absence of any strong or moderate statistically significant correlation when susceptibilities of either triclosan or sodium hypochlorite were compared for any of the tested antibiotics. On the other hand, correlation coefficients for MICs of benzalkonium chloride and chlorhexidine were calculated above 0.4 for susceptibility to quinolones, beta-lactams, and also macrolides. Our data do not support any selective pressure for association between biocides and antibiotics resistance and furthermore do not allow for a defined risk evaluation for some of the compounds. Importantly, our data clearly indicate that there does not involve any risk of selection for antibiotic resistance for the compounds triclosan and sodium hypochlorite. These data hence infer that biocide selection for antibiotic resistance has had so far a less significant impact than feared.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVE: To investigate correlations between preoperative hearing thresholds and postoperative aided thresholds and speech understanding of users of Bone-anchored Hearing Aids (BAHA). Such correlations may be useful to estimate the postoperative outcome with BAHA from preoperative data. STUDY DESIGN: Retrospective case review. SETTING: Tertiary referral center. PATIENTS:: Ninety-two adult unilaterally implanted BAHA users in 3 groups: (A) 24 subjects with a unilateral conductive hearing loss, (B) 38 subjects with a bilateral conductive hearing loss, and (C) 30 subjects with single-sided deafness. INTERVENTIONS: Preoperative air-conduction and bone-conduction thresholds and 3-month postoperative aided and unaided sound-field thresholds as well as speech understanding using German 2-digit numbers and monosyllabic words were measured and analyzed. MAIN OUTCOME MEASURES: Correlation between preoperative air-conduction and bone-conduction thresholds of the better and of the poorer ear and postoperative aided thresholds as well as correlations between gain in sound-field threshold and gain in speech understanding. RESULTS: Aided postoperative sound-field thresholds correlate best with BC threshold of the better ear (correlation coefficients, r2 = 0.237 to 0.419, p = 0.0006 to 0.0064, depending on the group of subjects). Improvements in sound-field threshold correspond to improvements in speech understanding. CONCLUSION: When estimating expected postoperative aided sound-field thresholds of BAHA users from preoperative hearing thresholds, the BC threshold of the better ear should be used. For the patient groups considered, speech understanding in quiet can be estimated from the improvement in sound-field thresholds.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We present a geospatial model to predict the radiofrequency electromagnetic field from fixed site transmitters for use in epidemiological exposure assessment. The proposed model extends an existing model toward the prediction of indoor exposure, that is, at the homes of potential study participants. The model is based on accurate operation parameters of all stationary transmitters of mobile communication base stations, and radio broadcast and television transmitters for an extended urban and suburban region in the Basel area (Switzerland). The model was evaluated by calculating Spearman rank correlations and weighted Cohen's kappa (kappa) statistics between the model predictions and measurements obtained at street level, in the homes of volunteers, and in front of the windows of these homes. The correlation coefficients of the numerical predictions with street level measurements were 0.64, with indoor measurements 0.66, and with window measurements 0.67. The kappa coefficients were 0.48 (95%-confidence interval: 0.35-0.61) for street level measurements, 0.44 (95%-CI: 0.32-0.57) for indoor measurements, and 0.53 (95%-CI: 0.42-0.65) for window measurements. Although the modeling of shielding effects by walls and roofs requires considerable simplifications of a complex environment, we found a comparable accuracy of the model for indoor and outdoor points.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: To determine the performance of a newly developed examination chair as compared with the clinical standard of assessing internal rotation (IR) of the flexed hip with a goniometer. METHODS: The examination chair allowed measurement of IR in a sitting position simultaneously in both hips, with hips and knees flexed 90 degrees, lower legs hanging unsupported and a standardized load of 5 kg applied to both ankles using a bilateral pulley system. Clinical assessment of IR was performed in supine position with hips and knees flexed 90 degrees using a goniometer. Within the framework of a population-based inception cohort study, we calculated inter-observer agreement in two samples of 84 and 64 consecutive, unselected young asymptomatic males using intra-class correlation coefficients (ICC) and determined the correlation between IR assessed with examination chair and clinical assessment. RESULTS: Inter-observer agreement was excellent for the examination chair (ICC right hip, 0.92, 95% confidence interval [CI] 0.89-0.95; ICC left hip, 0.90, 95% CI 0.86-0.94), and considerably higher than that seen with clinical assessment (ICC right hip, 0.65, 95% CI 0.49-0.77; ICC left hip, 0.69, 95% CI 0.54-0.80, P for difference in ICC between examination chair and clinical assessment correlation was strong (Pearson's coefficient, 0.75, 95% CI 0.62-0.84). CONCLUSIONS: The use of the examination chair resulted in a precise assessment of hip IR in our population-based inception cohort study of young asymptomatic males. It was strongly correlated with standard clinical assessment of IR but was considerably more reliable.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study evaluated the performance of the DIAGNOdent pen laser fluorescence device (LFpen) in comparison with visual examination (VE), bitewing radiographs (BW) and visual examination combined with bitewing radiographs (VEBW) in detecting secondary approximal caries associated with composite restorations. In total, 60 approximal surfaces from 43 permanent molars with composite restorations were assessed twice by two examiners using the LFpen, VE, BW and VEBW. After histological preparation and hardness measurements, the sample was assigned to either a crown or root caries group, depending on the location of the lesions as the gold standard. For crown caries at D1, the highest values of specificity and sensitivity were observed for the LFpen at a cutoff value of 18 (1.00) and for the VEBW (0.89). At D3 (cutoff of 30), the LFpen showed the highest values of sensitivity and specificity. For root caries, the LFpen and VEBW showed the highest values of specificity (0.54), sensitivity (0.81) and accuracy (0.69). The Spearman rank correlation coefficients for crown/root caries with histology were 0.54/0.37 (LFpen), 0.29/0.10 (BW), 0.29/0.18 (VE) and 0.23/0.37 (VEBW). For the LFpen, the ICC varied from 0.80 (interexaminer) to 0.97 (intraexaminer B); the kappa value was 0.19 for BW and 0.35 for VE (interexaminer). Intraexaminer kappa values for BW were 0.25 (A) and 0.29 (B), and those for VE were 0.31 (A) and 0.32 (B). The LFpen device exhibited a performance comparable to that of conventional methods but with higher interexaminer reproducibility. Therefore, the LFpen should be considered an auxiliary method for the detection of secondary approximal caries associated with composite restorations.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Osteoarticular allograft is one possible treatment in wide surgical resections with large defects. Performing best osteoarticular allograft selection is of great relevance for optimal exploitation of the bone databank, good surgery outcome and patient’s recovery. Current approaches are, however, very time consuming hindering these points in practice. We present a validation study of a software able to perform automatic bone measurements used to automatically assess the distal femur sizes across a databank. 170 distal femur surfaces were reconstructed from CT data and measured manually using a size measure protocol taking into account the transepicondyler distance (A), anterior-posterior distance in medial condyle (B) and anterior-posterior distance in lateral condyle (C). Intra- and inter-observer studies were conducted and regarded as ground truth measurements. Manual and automatic measures were compared. For the automatic measurements, the correlation coefficients between observer one and automatic method, were of 0.99 for A measure and 0.96 for B and C measures. The average time needed to perform the measurements was of 16 h for both manual measurements, and of 3 min for the automatic method. Results demonstrate the high reliability and, most importantly, high repeatability of the proposed approach, and considerable speed-up on the planning.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This pilot study defines the feasibility of cartilage assessment in symptomatic femoroacetabular impingement patients using intra-articular delayed gadolinium-enhanced MRI of cartilage (ia-dGEMRIC). Nine patients were scanned preliminary to study the contrast infiltration process into hip joint cartilage. Twenty-seven patients with symptomatic femoroacetabular impingement were subsequently scanned with intra-articular delayed gadolinium-enhanced MRI of cartilage. These T(1) findings were correlated to morphological findings. Zonal variations were studied. This pilot study demonstrates a significant difference between the pre- and postcontrast T(1) values (P < 0.001) remaining constant for 45 min. We noted higher mean T(1) values in morphologically normal-appearing cartilage than in damaged cartilage, which was statistically significant for all zones except the anterior-superior zone. Intraobserver (0.972) and interobserver correlation coefficients (0.933) were statistically significant. This study outlines the feasibility of intra-articular delayed gadolinium-enhanced MRI of cartilage for assessment of cartilage changes in patients with femoroacetabular impingement. It can also define the topographic extent and differing severities of cartilage damage.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The level of improvement in the audiological results of Baha(®) users mainly depends on the patient's preoperative hearing thresholds and the type of Baha sound processor used. This investigation shows correlations between the preoperative hearing threshold and postoperative aided thresholds and audiological results in speech understanding in quiet of 84 Baha users with unilateral conductive hearing loss, bilateral conductive hearing loss and bilateral mixed hearing loss. Secondly, speech understanding in noise of 26 Baha users with different Baha sound processors (Compact, Divino, and BP100) is investigated. Linear regression between aided sound field thresholds and bone conduction (BC) thresholds of the better ear shows highest correlation coefficients and the steepest slope. Differences between better BC thresholds and aided sound field thresholds are smallest for mid-frequencies (1 and 2 kHz) and become larger at 0.5 and 4 kHz. For Baha users, the gain in speech recognition in quiet can be expected to lie in the order of magnitude of the gain in their hearing threshold. Compared to its predecessor sound processors Baha(®) Compact and Baha(®) Divino, Baha(®) BP100 improves speech understanding in noise significantly by +0.9 to +4.6 dB signal-to-noise ratio, depending on the setting and the use of directional microphone. For Baha users with unilateral and bilateral conductive hearing loss and bilateral mixed hearing loss, audiological results in aided sound field thresholds can be estimated with the better BC hearing threshold. The benefit in speech understanding in quiet can be expected to be similar to the gain in their sound field hearing threshold. The most recent technology of Baha sound processor improves speech understanding in noise by an order of magnitude that is well perceived by users and which can be very useful in everyday life.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: To evaluate diffusion-weighted magnetic resonance (MR) imaging of the human placenta in fetuses with and fetuses without intrauterine growth restriction (IUGR) who were suspected of having placental insufficiency. MATERIALS AND METHODS: The study was approved by the local ethics committee, and written informed consent was obtained. The authors retrospectively evaluated 1.5-T fetal MR images from 102 singleton pregnancies (mean gestation ± standard deviation, 29 weeks ± 5; range, 21-41 weeks). Morphologic and diffusion-weighted MR imaging were performed. A region of interest analysis of the apparent diffusion coefficient (ADC) of the placenta was independently performed by two observers who were blinded to clinical data and outcome. Placental insufficiency was diagnosed if flattening of the growth curve was detected at obstetric ultrasonography (US), if the birth weight was in the 10th percentile or less, or if fetal weight estimated with US was below the 10th percentile. Abnormal findings at Doppler US of the umbilical artery and histopathologic examination of specimens from the placenta were recorded. The ADCs in fetuses with placental insufficiency were compared with those in fetuses of the same gestational age without placental insufficiency and tested for normal distribution. The t tests and Pearson correlation coefficients were used to compare these results at 5% levels of significance. RESULTS: Thirty-three of the 102 pregnancies were ultimately categorized as having an insufficient placenta. MR imaging depicted morphologic changes (eg, infarction or bleeding) in 27 fetuses. Placental dysfunction was suspected in 33 fetuses at diffusion-weighted imaging (mean ADC, 146.4 sec/mm(2) ± 10.63 for fetuses with placental insufficiency vs 177.1 sec/mm(2) ± 18.90 for fetuses without placental insufficiency; P < .01, with one false-positive case). The use of diffusion-weighted imaging in addition to US increased sensitivity for the detection of placental insufficiency from 73% to 100%, increased accuracy from 91% to 99%, and preserved specificity at 99%. CONCLUSION: Placental dysfunction associated with growth restriction is associated with restricted diffusion and reduced ADC. A decreased ADC used as an early marker of placental damage might be indicative of pregnancy complications such as IUGR.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The Pulmonary Embolism Severity Index (PESI) is a validated clinical prognostic model for patients with acute pulmonary embolism (PE). Our goal was to assess the PESI's inter-rater reliability in patients diagnosed with PE. We prospectively identified consecutive patients diagnosed with PE in the emergency department of a Swiss teaching hospital. For all patients, resident and attending physician raters independently collected the 11 PESI variables. The raters then calculated the PESI total point score and classified patients into one of five PESI risk classes (I-V) and as low (risk classes I/II) versus higher-risk (risk classes III-V). We examined the inter-rater reliability for each of the 11 PESI variables, the PESI total point score, assignment to each of the five PESI risk classes, and classification of patients as low versus higher-risk using kappa ( ) and intra-class correlation coefficients (ICC). Among 48 consecutive patients with an objective diagnosis of PE, reliability coefficients between resident and attending physician raters were > 0.60 for 10 of the 11 variables comprising the PESI. The inter-rater reliability for the PESI total point score (ICC: 0.89, 95% CI: 0.81-0.94), PESI risk class assignment ( : 0.81, 95% CI: 0.66-0.94), and the classification of patients as low versus higher-risk ( : 0.92, 95% CI: 0.72-0.98) was near perfect. Our results demonstrate the high reproducibility of the PESI, supporting the use of the PESI for risk stratification of patients with PE.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background Leg edema is a common manifestation of various underlying pathologies. Reliable measurement tools are required to quantify edema and monitor therapeutic interventions. Aim of the present work was to investigate the reproducibility of optoelectronic leg volumetry over 3 weeks' time period and to eliminate daytime related within-individual variability. Methods Optoelectronic leg volumetry was performed in 63 hairdressers (mean age 45 ± 16 years, 85.7% female) in standing position twice within a minute for each leg and repeated after 3 weeks. Both lower leg (legBD) and whole limb (limbBF) volumetry were analysed. Reproducibility was expressed as analytical and within-individual coefficients of variance (CVA, CVW), and as intra-class correlation coefficients (ICC). Results A total of 492 leg volume measurements were analysed. Both legBD and limbBF volumetry were highly reproducible with CVA of 0.5% and 0.7%, respectively. Within-individual reproducibility of legBD and limbBF volumetry over a three weeks' period was high (CVW 1.3% for both; ICC 0.99 for both). At both visits, the second measurement revealed a significantly higher volume compared to the first measurement with a mean increase of 7.3 ml ± 14.1 (0.33% ± 0.58%) for legBD and 30.1 ml ± 48.5 ml (0.52% ± 0.79%) for limbBF volume. A significant linear correlation between absolute and relative leg volume differences and the difference of exact day time of measurement between the two study visits was found (P < .001). A therefore determined time-correction formula permitted further improvement of CVW. Conclusions Leg volume changes can be reliably assessed by optoelectronic leg volumetry at a single time point and over a 3 weeks' time period. However, volumetry results are biased by orthostatic and daytime-related volume changes. The bias for day-time related volume changes can be minimized by a time-correction formula.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to compare craniofacial morphology and soft tissue profiles in patients with complete bilateral cleft lip and palate at 9 years of age, treated in two European cleft centres with delayed hard palate closure but different treatment protocols. The cephalometric data of 83 consecutively treated patients were compared (Gothenburg, N=44; Nijmegen, N=39). In total, 18 hard tissue and 10 soft tissue landmarks were digitized by one operator. To determine the intra-observer reliability 20 cephalograms were digitized twice with a monthly interval. Paired t-test, Pearson correlation coefficients and multiple regression models were applied for statistical analysis. Hard and soft tissue data were superimposed using the Generalized Procrustes Analysis. In Nijmegen, the maxilla was protrusive for hard and soft tissue values (P=0.001, P=0.030, respectively) and the maxillary incisors were retroclined (P<0.001), influencing the nasolabial angle, which was increased in comparison with Gothenburg (P=0.004). In conclusion, both centres showed a favourable craniofacial form at 9-10 years of age, although there were significant differences in the maxillary prominence, the incisor inclination and soft tissue cephalometric values. Follow-up of these patients until facial growth has ceased, may elucidate components for outcome improvement.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Posterior lumbar fusion is a frequently performed procedure in spinal surgery. High percentages of good and excellent results are indicated by physicians. On the other hand patient-based outcomes are reported. Little is known about the correlations of these two assessment types. We aimed at their comparison. The analysis included 1013 patients with degenerative spinal disease or spondylolisthesis from an international spine registry, treated with posterior lumbar fusion. All patients were pre/postop assessed by physician-based McNab criteria (‘excellent’, ‘good’, ‘fair’, ‘poor’). Of these patients, 210 (mean age 61 years; 57% females) were in addition assessed by patient-based Oswestry Disability Index (ODI). The remaining 803 patients (mean age 59 years; 56% females) were assessed by patient-based Core Outcome Measure Index (COMI), including Visual Analogue Scale (VAS) for back and leg pain as well as verbal self-rating (‘helped a lot’, ‘helped’, ‘helped only little’, ‘didn’t help’, ‘made things worse’). McNab criteria were compared to the Minimal Clinically Important Difference (MCID) in ODI (12.8), in VAS back (1.2) and leg pain (1.6). We investigated the correlations between McNab criteria and these patient-based outcomes. In the ‘excellent’ group as rated by physicians, the proposed MCID was reached in 83% of patients for ODI, in 69% for VAS back and in 83% for VAS leg pain. All patients said the treatment had ‘helped’ or ‘helped a lot’. In the ‘good’ group 56% (ODI), 66% (back pain) and 86% (leg pain) reached the MCID. 96% of patients perceived the treatment as positive. In the ‘fair’ group 37% (ODI), 55% (back pain) and 63% (leg pain) reached the MCID. 49% had positive treatment considerations. The ‘poor’ group revealed 30% (ODI), 35% (back pain) and 44% (leg pain) of patients with reached MCID. Only 15% rated the treatment as positive. The Spearman correlation coefficients between McNab criteria on the one hand and ODI, back and leg pain as well as patients’ verbal self-rating on the other hand were 0.57, 0.37, 0.36 and 0.46 respectively. The comparison of physician and patient-based outcomes showed the highest correlations between McNab criteria and ODI, somewhat weaker correlations with patients’ self-rating and the weakest correlations with back and leg pain. Based on these findings, physicians’ evaluation of patient outcomes can be considered a valuable part of patient assessment, corresponding very well with patients’ perceptions of success or failure of spinal surgery.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Perennial snow and ice (PSI) extent is an important parameter of mountain environments with regard to its involvement in the hydrological cycle and the surface energy budget. We investigated interannual variations of PSI in nine mountain regions of interest (ROI) between 2000 and 2008. For that purpose, a novel MODIS data set processed at the Canada Centre for Remote Sensing at 250 m spatial resolution was utilized. The extent of PSI exhibited significant interannual variations, with coefficients of variation ranging from 5% to 81% depending on the ROI. A strong negative relationship was found between PSI and positive degree-days (threshold 0°C) during the summer months in most ROIs, with linear correlation coefficients (r) being as low as r = −0.90. In the European Alps and Scandinavia, PSI extent was significantly correlated with annual net glacier mass balances, with r = 0.91 and r = 0.85, respectively, suggesting that MODIS-derived PSI extent may be used as an indicator of net glacier mass balances. Validation of PSI extent in two land surface classifications for the years 2000 and 2005, GLC-2000 and Globcover, revealed significant discrepancies of up to 129% for both classifications. With regard to the importance of such classifications for land surface parameterizations in climate and land surface process models, this is a potential source of error to be investigated in future studies. The results presented here provide an interesting insight into variations of PSI in several ROIs and are instrumental for our understanding of sensitive mountain regions in the context of global climate change assessment.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A universal and robust analytical method for the determination of Δ9-tetrahydrocannabinol (THC) and two of its metabolites Δ9-(11-OH)-tetrahydrocannabinol (11-OH-THC) and 11-nor-Δ9-carboxy-tetrahydrocannabinol (THC-COOH) in human whole blood was developed and validated for use in forensic toxicology. Protein precipitation, integrated solid phase extraction and on-line enrichment followed by high-performance liquid chromatography separation and detection with a triple quadrupole mass spectrometer were combined. The linear ranges used for the three cannabinoids were from 0.5 to 20 ng/mL for THC and 11-OH-THC and from 2.5 to 100 ng/mL for THC-COOH, therefore covering the requirements for forensic use. Correlation coefficients of 0.9980 or better were achieved for all three analytes. No relevant hydrolysis was observed for THC-COOH glucuronide with this procedure--in contrast to our previous GC-MS procedure, which obviously lead to an artificial increase of the THC-COOH concentration due to the hydrolysis of the glucuronide-conjugate occurring at high pH during the phase-transfer catalyzed methylation step.