36 resultados para circular patch resonators

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the field of computer assisted orthopedic surgery (CAOS) the anterior pelvic plane (APP) is a common concept to determine the pelvic orientation by digitizing distinct pelvic landmarks. As percutaneous palpation is - especially for obese patients - known to be error-prone, B-mode ultrasound (US) imaging could provide an alternative means. Several concepts of using ultrasound imaging to determine the APP landmarks have been introduced. In this paper we present a novel technique, which uses local patch statistical shape models (SSMs) and a hierarchical speed of sound compensation strategy for an accurate determination of the APP. These patches are independently matched and instantiated with respect to associated point clouds derived from the acquired ultrasound images. Potential inaccuracies due to the assumption of a constant speed of sound are compensated by an extended reconstruction scheme. We validated our method with in-vitro studies using a plastic bone covered with a soft-tissue simulation phantom and with a preliminary cadaver trial.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gerbode's defect, a left ventricular-to-right atrial communication, with involvement of the tricuspid valve acquired after bacterial endocarditis can be challenging to repair. We report a modified technique for a shunt closure and reconstruction of the tricuspid valve using a plicated bovine pericardial patch. Combining such a repair with a left ventricular patch resulted in a complete defect closure and competent tricuspid valve without regurgitation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Carotid endarterectomy (CEA) reduces the risk of stroke in patients with symptomatic (>50%) and asymptomatic (>60%) carotid artery stenosis. Here we report the midterm results of a microsurgical non-patch technique and compare these findings to those in the literature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND AIMS: Naturally occurring anti-idiotypic antibodies structurally mimic the original antibody epitope. Anti-idiotypes, therefore, are interesting tools for the portrayal of conformational B-cell epitopes of allergens. In this study we used this strategy particularly for major timothy grass pollen (Phleum pratense) allergen Phl p 1. METHODS AND RESULTS: We used a combinatorial phage display library constructed from the peripheral IgG repertoire of a grass pollen allergic patient which was supposed to contain anti-idiotypic Fab specificities. Using purified anti-Phl p 1 IgG for biopanning, several Fab displaying phage clones could be isolated. 100 amplified colonies were screened for their binding capacity to anti-Phl p 1-specific antibodies, finally resulting in four distinct Fab clones according to sequence analysis. Interestingly, heavy chains of all clones derived from the same germ line sequence and showed high homology in their CDRs. Projecting their sequence information on the surface of the natural allergen Phl p 1 (PDB ID: 1N10) indicated matches on the N-terminal domain of the homo-dimeric allergen, including the bridging region between the two monomers. The resulting epitope patches were formed by spatially distant sections of the primary allergen sequence. CONCLUSION: In this study we report that anti-idiotypic specificities towards anti-Phl p 1 IgG, selected from a Fab library of a grass pollen allergic patient, mimic a conformational epitope patch being distinct from a previously reported IgE epitope area.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background—Pulmonary vein stenosis (PVST) is a well-known complication of pulmonary vein isolation (PVI). Specific anatomically designed ablation catheters for antral PVI have not been evaluated with regard to the incidence of PVST. We investigated the incidence, severity, and characteristics of PVST after PVI with the Pulmonary Vein Ablation Catheter (PVAC) and phased radiofrequency technology. Methods and Results A total of 100 patients (55 men) underwent PVI for atrial fibrillation using the PVAC. PVI was guided by selective angiography of each pulmonary vein (PV) in 70 (70%) patients and by reconstructed 3D atriography (ATG) in 30 (30%) patients. Gadolinium-enhanced MRI or multidetector CT was performed in all patients before treatment and 93±78 days after PVI. PVST was classified as follows: insignificant (<25%), mild (25%–50%), moderate (50%–75%), or severe (>75%). A total of 410 PVs were analyzed. Cardiac imaging demonstrated a detectable narrowing of the PV diameter in 23 (23%) patients and in 28 (7%) PVs. In detail, insignificant PVST was observed in 12 (2.9%) PVs, mild PVST in 15 (3.7%), and moderate PVST in 1 (0.2%). No instances of severe PVST were observed. The use of 3D-ATG was associated with a lower incidence of PVST (0.8% [95% CI, 0.0%–2.2%] versus 5.4% [95% CI, 2.7%–8.1%], P=0.027). Conclusions To our knowledge, this study is the first to report the incidence of PVST using the PVAC. In this regard, the PVAC seems to be safe if used in an experienced center. In addition, the use of 3D-ATG may decrease the risk of PVST.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Epidural blood patch (EBP) is one therapeutic measure for patients suffering from spontaneous intracranial hypotension (SIH) or post-lumbar puncture headaches. It has been proposed that an EBP may directly seal a spinal cerebrospinal fluid (CSF) fistula or result in an increase in intracranial pressure (ICP) by a shift of CSF from the spinal to the intracranial compartment. To the best of our knowledge this is the first case of a patient with SIH and neurological deterioration in whom ICP was measured before, during, and after spinal EBP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To report stabilization of closed, comminuted distal metaphyseal transverse fractures of the left tibia and fibula in a tiger using a hybrid circular-linear external skeletal fixator. STUDY DESIGN: Clinical report. ANIMAL: Juvenile tiger (15 months, 90 kg). METHODS: From imaging studies, the tiger had comminuted distal metaphyseal transverse fractures of the left tibia and fibula, with mild caudolateral displacement and moderate compression. Multiple fissures extended from the fractures through the distal metaphyses, extending toward, but not involving the distal tibial and fibular physes. A hybrid circular-linear external skeletal fixator was applied by closed reduction, to stabilize the fractures. RESULTS: The fractures healed and the fixator was removed 5 weeks after stabilization. Limb length and alignment were similar to the normal contralateral limb at hospital discharge, 8 weeks after surgery. Two weeks later, the tiger had fractures of the right tibia and fibula and was euthanatized. Necropsy confirmed pathologic fractures ascribed to copper deficiency. CONCLUSION: Closed application of the hybrid construct provided sufficient stability to allow this 90 kg tiger's juxta-articular fractures to heal with minimal complications and without disrupting growth from the adjacent physes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The pattern of contact sensitization to the supposedly most important allergens assembled in the baseline series differs between countries, presumably at least partly because of exposure differences. Objectives. To describe the prevalence of contact sensitization to allergens tested in consecutive patients in the years 2007 and 2008, and to discuss possible differences.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vascular surgeons perform numerous highly sophisticated and delicate procedures. Due to restrictions in training time and the advent of endovascular techniques, new concepts including alternative environments for training and assessment of surgical skills are required. Over the past decade, training on simulators and synthetic models has become more sophisticated and lifelike. This study was designed to evaluate the impact of a 3-day intense training course in open vascular surgery on both specific and global vascular surgical skills.

Relevância:

20.00% 20.00%

Publicador: