64 resultados para blood glucose monitoring
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Self-monitoring of blood glucose plays an important role in the management of diabetes and has been shown to improve metabolic control. The use of blood glucose meters in clinical practice requires sufficient reliability to allow adequate treatment. Direct comparison of different blood glucose meters in clinical practice, independent of the manufactures is scarce. We, therefore, aimed to evaluate three frequently used blood glucose meters in daily clinical practice.
Resumo:
Self-monitoring of blood glucose (SMBG) in type 2 diabetes has increasingly been shown to display beneficial effects on glycemic control. SMBG is not only associated with a reduction of hemoglobin A1c but has also been demonstrated to increase patients' awareness of the disease. SMBG has also the potential to visualize and predict hypoglycemic episodes. International guidelines by the International Diabetes Federation, the European Society of Cardiology, and the European Association for the Study of Diabetes and also the International Society for Pediatric and Adolescent Diabetes emphasize that SMBG is an integral part of self-management. More recently, two European consensus documents have been published to give recommendations for frequency and timing of SMBG also for various clinical scenarios. Recently, a European expert panel was held to further facilitate and enhance standardized approaches to SMBG. The aim was to present simple, clinically meaningful, and standardized SMBG strategies for type 2 diabetes. The panel recommended a less intensive and an intensive scheme for SMBG across the type 2 diabetes continuum. The length and frequency of SMBG performance depend on the clinical circumstances and the quality of glycemic control. The expert panel also recommended further evaluation of various schemes for SMBG in type 2 diabetes in clinical studies.
Resumo:
The role of glucagon-like peptide (GLP)-1-based treatment approaches for type 2 diabetes mellitus (T2DM) is increasing. Although self-monitoring of blood glucose (SMBG) has been performed in numerous studies on GLP-1 analogs and dipeptidyl peptidase-4 inhibitors, the potential role of SMBG in GLP-1-based treatment strategies has not been elaborated. The expert recommendation suggests individualized SMBG strategies in GLP-1-based treatment approaches and suggests simple and clinically applicable SMBG schemes. Potential benefits of SMBG in GLP-1-based treatment approaches are early assessment of treatment success or failure, timely modification of treatment, detection of hypoglycemic episodes, assessment of glucose excursions, and support of diabetes management and diabetes education. Its length and frequency should depend on the clinical setting and the quality of metabolic control. It is considered to play an important role for the optimization of diabetes management in T2DM patients treated with GLP-1-based approaches.
Resumo:
To assess the effect of self-monitoring of blood glucose (SMBG) on glycaemic control in non-insulin treated patients with type 2 diabetes by means of a systematic review and meta-analysis.
Resumo:
The increasing role for structured and personalized self-monitoring of blood glucose (SMBG) in management of type 2 diabetes has been underlined by randomized and prospective clinical trials. These include Structured Testing Program (or STeP), St. Carlos, Role of Self-Monitoring of Blood Glucose and Intensive Education in Patients with Type 2 Diabetes Not Receiving Insulin, and Retrolective Study Self-Monitoring of Blood Glucose and Outcome in Patients with Type 2 Diabetes (or ROSSO)-in-praxi follow-up. The evidence for the benefit of SMBG both in insulin-treated and non-insulin-treated patients with diabetes is also supported by published reviews, meta-analyses, and guidelines. A Cochrane review reported an overall effect of SMBG on glycemic control up to 6 months after initiation, which was considered to subside after 12 months. Particularly, the 12-month analysis has been criticized for the inclusion of a small number of studies and the conclusions drawn. The aim of this article is to review key publications on SMBG and also to put them into perspective with regard to results of the Cochrane review and current aspects of diabetes management.
Resumo:
The role for the novel treatment approach of sodium-glucose cotransporter-2 (SGLT-2) in type 2 diabetes is increasing. Structured self-monitoring of blood glucose (SMBG), based on a less intensive and a more intensive scheme, may contribute to an optimization of SGLT-2 inhibitor based treatment. The current expert recommendation suggests individualized approaches of SMBG, using simple and clinically applicable schemes. Potential benefits of SMBG in SGLT-2 inhibitor based treatment approaches are early assessment of treatment success or failure, timely modification of treatment, detection of hypoglycemic episodes, assessment of glucose excursions, and support of diabetes management and education. The length and frequency of SMBG should depend on the clinical setting and the quality of metabolic control.
Resumo:
ntroduction: The ProAct study has shown that a pump switch to the Accu-Chek® Combo system (Roche Diagnostics Deutschland GmbH, Mannheim, Germany) in type 1 diabetes patients results in stable glycemic control with significant improvements in glycated hemoglobin (HbA1c) in patients with unsatisfactory baseline HbA1c and shorter pump usage time. Patients and Methods: In this post hoc analysis of the ProAct database, we investigated the glycemic control and glycemic variability at baseline by determination of several established parameters and scores (HbA1c, hypoglycemia frequency, J-score, Hypoglycemia and Hyperglycemia Indexes, and Index of Glycemic Control) in participants with different daily bolus and blood glucose measurement frequencies (less than four day, four or five per day, and more than five per day, in both cases). The data were derived from up to 299 patients (172 females, 127 males; age [mean±SD], 39.4±15.2 years; pump treatment duration, 7.0±5.2 years). Results: Participants with frequent glucose readings had better glycemic control than those with few readings (more than five readings per day vs. less than four readings per day: HbA1c, 7.2±1.1% vs. 8.0±0.9%; mean daily blood glucose, 151±22 mg/dL vs. 176±30 mg/dL; percentage of readings per month >300 mg/dL, 10±4% vs. 14±5%; percentage of readings in target range [80-180 mg/dL], 59% vs. 48% [P<0.05 in all cases]) and had a lower glycemic variability (J-score, 49±13 vs. 71±25 [P<0.05]; Hyperglycemia Index, 0.9±0.5 vs. 1.9±1.2 [P<0.05]; Index of Glycemic Control, 1.9±0.8 vs. 3.1±1.6 [P<0.05]; Hypoglycemia Index, 0.9±0.8 vs. 1.2±1.3 [not significant]). Frequent self-monitoring of blood glucose was associated with a higher number of bolus applications (6.1±2.2 boluses/day vs. 4.5±2.0 boluses/day [P<0.05]). Therefore, a similar but less pronounced effect on glycemic variability in favor of more daily bolus applications was observed (more than five vs. less than four bolues per day: J-score, 57±17 vs. 63±25 [not significant]; Hypoglycemia Index, 1.0±1.0 vs. 1.5±1.4 [P<0.05]; Hyperglycemia Index, 1.3±0.6 vs. 1.6±1.1 [not significant]; Index of Glycemic Control, 2.3±1.1 vs. 3.1±1.7 [P<0.05]). Conclusions: Pump users who perform frequent daily glucose readings have a better glycemic control with lower glycemic variability.
Resumo:
AIM Depending on intensity, exercise may induce a strong hormonal and metabolic response, including acid-base imbalances and changes in microcirculation, potentially interfering with the accuracy of continuous glucose monitoring (CGM). The present study aimed at comparing the accuracy of the Dexcom G4 Platinum (DG4P) CGM during continuous moderate and intermittent high-intensity exercise (IHE) in adults with type 1 diabetes (T1DM). METHODS Ten male individuals with well-controlled T1DM (HbA1c 7.0±0.6% [54±6mmol/mol]) inserted the DG4P sensor 2 days prior to a 90min cycling session (50% VO2peak) either with (IHE) or without (CONT) a 10s all-out sprint every 10min. Venous blood samples for reference glucose measurement were drawn every 10min and euglycemia (target 7mmol/l) was maintained using an oral glucose solution. Additionally, lactate and venous blood gas variables were determined. RESULTS Mean reference blood glucose was 7.6±0.2mmol/l during IHE and 6.7±0.2mmol/l during CONT (p<0.001). IHE resulted in significantly higher levels of lactate (7.3±0.5mmol/l vs. 2.6±0.3mmol/l, p<0.001), while pH values were significantly lower in the IHE group (7.27 vs. 7.38, p=0.001). Mean absolute relative difference (MARD) was 13.3±2.2% for IHE and 13.6±2.8% for CONT suggesting comparable accuracy (p=0.90). Using Clarke Error Grid Analysis, 100% of CGM values during both IHE and CONT were in zones A and B (IHE: 77% and 23%; CONT: 78% and 22%). CONCLUSIONS The present study revealed good and comparable accuracy of the DG4P CGM system during intermittent high intensity and continuous moderate intensity exercise, despite marked differences in metabolic conditions. This corroborates the clinical robustness of CGM under differing exercise conditions. CLINICAL TRIAL REGISTRATION NUMBER ClinicalTrials.gov NCT02068638.
Resumo:
OBJECTIVES: Hypoglycaemia (glucose <2.2 mmol/l) is a defining feature of severe malaria, but the significance of other levels of blood glucose has not previously been studied in children with severe malaria. METHODS: A prospective study of 437 consecutive children with presumed severe malaria was conducted in Mali. We defined hypoglycaemia as <2.2 mmol/l, low glycaemia as 2.2-4.4 mmol/l and hyperglycaemia as >8.3 mmol/l. Associations between glycaemia and case fatality were analysed for 418 children using logistic regression models and a receiver operator curve (ROC). RESULTS: There was a significant difference between blood glucose levels in children who died (median 4.6 mmol/l) and survivors (median 7.6 mmol/l, P < 0.001). Case fatality declined from 61.5% of the hypoglycaemic children to 46.2% of those with low glycaemia, 13.4% of those with normal glycaemia and 7.6% of those with hyperglycaemia (P < 0.001). Logistic regression showed an adjusted odds ratio (AOR) of 0.75 (0.64-0.88) for case fatality per 1 mmol/l increase in baseline blood glucose. Compared to a normal blood glucose, hypoglycaemia and low glycaemia both significantly increased the odds of death (AOR 11.87, 2.10-67.00; and 5.21, 1.86-14.63, respectively), whereas hyperglycaemia reduced the odds of death (AOR 0.34, 0.13-0.91). The ROC [area under the curve at 0.753 (95% CI 0.684-0.820)] indicated that glycaemia had a moderate predictive value for death and identified an optimal threshold at glycaemia <6.1 mmol/l, (sensitivity 64.5% and specificity 75.1%). CONCLUSIONS: If there is a threshold of blood glucose which defines a worse prognosis, it is at a higher level than the current definition of 2.2 mmol/l.
Resumo:
Abstract Background and Aims: Data on the influence of calibration on accuracy of continuous glucose monitoring (CGM) are scarce. The aim of the present study was to investigate whether the time point of calibration has an influence on sensor accuracy and whether this effect differs according to glycemic level. Subjects and Methods: Two CGM sensors were inserted simultaneously in the abdomen on either side of 20 individuals with type 1 diabetes. One sensor was calibrated predominantly using preprandial glucose (calibration(PRE)). The other sensor was calibrated predominantly using postprandial glucose (calibration(POST)). At minimum three additional glucose values per day were obtained for analysis of accuracy. Sensor readings were divided into four categories according to the glycemic range of the reference values (low, ≤4 mmol/L; euglycemic, 4.1-7 mmol/L; hyperglycemic I, 7.1-14 mmol/L; and hyperglycemic II, >14 mmol/L). Results: The overall mean±SEM absolute relative difference (MARD) between capillary reference values and sensor readings was 18.3±0.8% for calibration(PRE) and 21.9±1.2% for calibration(POST) (P<0.001). MARD according to glycemic range was 47.4±6.5% (low), 17.4±1.3% (euglycemic), 15.0±0.8% (hyperglycemic I), and 17.7±1.9% (hyperglycemic II) for calibration(PRE) and 67.5±9.5% (low), 24.2±1.8% (euglycemic), 15.5±0.9% (hyperglycemic I), and 15.3±1.9% (hyperglycemic II) for calibration(POST). In the low and euglycemic ranges MARD was significantly lower in calibration(PRE) compared with calibration(POST) (P=0.007 and P<0.001, respectively). Conclusions: Sensor calibration predominantly based on preprandial glucose resulted in a significantly higher overall sensor accuracy compared with a predominantly postprandial calibration. The difference was most pronounced in the hypo- and euglycemic reference range, whereas both calibration patterns were comparable in the hyperglycemic range.
Resumo:
Approximate entropy (ApEn) of blood pressure (BP) can be easily measured based on software analysing 24-h ambulatory BP monitoring (ABPM), but the clinical value of this measure is unknown. In a prospective study we investigated whether ApEn of BP predicts, in addition to average and variability of BP, the risk of hypertensive crisis. In 57 patients with known hypertension we measured ApEn, average and variability of systolic and diastolic BP based on 24-h ABPM. Eight of these fifty-seven patients developed hypertensive crisis during follow-up (mean follow-up duration 726 days). In bivariate regression analysis, ApEn of systolic BP (P<0.01), average of systolic BP (P=0.02) and average of diastolic BP (P=0.03) were significant predictors of hypertensive crisis. The incidence rate ratio of hypertensive crisis was 14.0 (95% confidence interval (CI) 1.8, 631.5; P<0.01) for high ApEn of systolic BP as compared to low values. In multivariable regression analysis, ApEn of systolic (P=0.01) and average of diastolic BP (P<0.01) were independent predictors of hypertensive crisis. A combination of these two measures had a positive predictive value of 75%, and a negative predictive value of 91%, respectively. ApEn, combined with other measures of 24-h ABPM, is a potentially powerful predictor of hypertensive crisis. If confirmed in independent samples, these findings have major clinical implications since measures predicting the risk of hypertensive crisis define patients requiring intensive follow-up and intensified therapy.
Resumo:
To assess the association of 1,5-anhydroglucitol (1,5-AG) with 2-h postprandial glucose values in type 2 diabetic patients followed over 12 months in an outpatient setting.
Resumo:
INTRODUCTION: The incidence of bloodstream infection (BSI) in extracorporeal life support (ECLS) is reported between 0.9 and 19.5%. In January 2006, the Extracorporeal Life Support Organization (ELSO) reported an overall incidence of 8.78% distributed as follows: respiratory: 6.5% (neonatal), 20.8% (pediatric); cardiac: 8.2% (neonatal) and 12.6% (pediatric). METHOD: At BC Children's Hospital (BCCH) daily surveillance blood cultures (BC) are performed and antibiotic prophylaxis is not routinely recommended. Positive BC (BC+) were reviewed, including resistance profiles, collection time of BC+, time to positivity and mortality. White blood cell count, absolute neutrophile count, immature/total ratio, platelet count, fibrinogen and lactate were analyzed 48, 24 and 0 h prior to BSI. A univariate linear regression analysis was performed. RESULTS: From 1999 to 2005, 89 patients underwent ECLS. After exclusion, 84 patients were reviewed. The attack rate was 22.6% (19 BSI) and 13.1% after exclusion of coagulase-negative staphylococci (n = 8). BSI patients were significantly longer on ECLS (157 h) compared to the no-BSI group (127 h, 95% CI: 106-148). Six BSI patients died on ECLS (35%; 4 congenital diaphragmatic hernias, 1 hypoplastic left heart syndrome and 1 after a tetralogy repair). BCCH survival on ECLS was 71 and 58% at discharge, which is comparable to previous reports. No patient died primarily because of BSI. No BSI predictor was identified, although lactate may show a decreasing trend before BSI (P = 0.102). CONCLUSION: Compared with ELSO, the studied BSI incidence was higher with a comparable mortality. We speculate that our BSI rate is explained by underreporting of "contaminants" in the literature, the use of broad-spectrum antibiotic prophylaxis and a higher yield with daily monitoring BC. We support daily surveillance blood cultures as an alternative to antibiotic prophylaxis in the management of patients on ECLS.