37 resultados para Ultrasonic irradiation
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Surgical navigation has proven to be a minimally invasive procedure that enables precise surgical interventions with reduced exposure to irradiation for patient and personnel. Fluoroscopy-based modules have prevailed on the market. For certain operations of the pelvis computed tomography is necessary with its high imaging quality and considerably larger scan volume. To enable navigation in these cases, matching of the CT data set and the patient's real pelvic bone is essential. The common pair point-matching algorithm is complemented by the surface-matching algorithm to achieve an even higher overall precision of the system. For conventional surface matching with a solid pointer, the bone has to be exposed from soft tissue quite extensively, using a solid pointer. This conflicts with the claim of computer-assisted surgery to be minimally invasive. We integrated an A-mode ultrasonic pointer with the intention to perform extended surface matching on the pelvic bone noninvasively. Related to the conventional method, comparable and to some extent even improved precision conditions could be established.
Resumo:
To establish the feasibility and tolerability of gefitinib (ZD1839, Iressa) with radiation (RT) or concurrent chemoradiation (CRT) with cisplatin (CDDP) in patients with advanced non-small cell lung cancer (NSCLC).
Resumo:
To assess safety and efficacy of tailored total lymphoid irradiation (tTLI) in cardiac transplant patients.
Resumo:
Root canal treatment is a frequently performed dental procedure and is carried out on teeth in which irreversible pulpitis has led to necrosis of the dental pulp. Removal of the necrotic tissue remnants and cleaning and shaping of the root canal are important phases of root canal treatment. Treatment options include the use of hand and rotary instruments and methods using ultrasonic or sonic equipment. OBJECTIVES: The objectives of this systematic review of randomized controlled trials were to determine the relative clinical effectiveness of hand instrumentation versus ultrasonic instrumentation alone or in conjunction with hand instrumentation for orthograde root canal treatment of permanent teeth. MATERIAL AND METHODS: The search strategy retrieved 226 references from the Cochrane Oral Health Group Trials Register (7), the Cochrane Central Register of Controlled Trials (CENTRAL) (12), MEDLINE (192), EMBASE (8) and LILACS (7). No language restriction was applied. The last electronic search was conducted on December 13th, 2007. Screening of eligible studies was conducted in duplicate and independently. RESULTS: Results were to be expressed as fixed-effect or random-effects models using mean differences for continuous outcomes and risk ratios for dichotomous outcomes with 95% confidence intervals. Heterogeneity was to be investigated including both clinical and methodological factors. No eligible randomized controlled trials were identified. CONCLUSIONS: This review illustrates the current lack of published or ongoing randomized controlled trials and the unavailability of high-level evidence based on clinically relevant outcomes referring to the effectiveness of ultrasonic instrumentation used alone or as an adjunct to hand instrumentation for orthograde root canal treatment. In the absence of reliable research-based evidence, clinicians should base their decisions on clinical experience, individual circumstances and in conjunction with patients' preferences where appropriate. Future randomized controlled trials might focus more closely on evaluating the effectiveness of combinations of these interventions with an emphasis on not only clinically relevant, but also patient-centered outcomes.
Resumo:
Therapy of metacarpal neck fractures depending on radiographically measured palmar angulation is discussed controversially in the literature. Some authors describe normal hand function of malunited metacarpal neck fractures with a palmar angulation up to 70°; others define 30° as the uppermost limit to maintain normal hand function. However, the methods of measuring palmar angulation are not clearly defined. Here, we present a new method to measure palmar angulation using ultrasound. The aim of this prospective study is to compare the radiographic methods of measuring palmar angulation with the ultrasound method. PATIENTS/MATERIAL AND METHOD: 20 patients with a neck fracture of the metacarpals IV or V were treated either conservatively or operatively. 2 weeks after trauma or operation, an x-ray was performed. 2 examiners measured the palmar angulation on the oblique and lateral projections using 2 different methods (medullary canal and dorsal cortex methods). At the same time, the 2 examiners performed measurements of palmar angulation using ultrasound. The measurements obtained with the different methods as well as by the 2 examiners at 2 different terms were compared. Intra- and interobserver reliability of each method was calculated, and for the ultrasound method a test for accuracy of the measured angles was performed.
Resumo:
Cutaneous scleroderma is a chronic inflammatory disease of the dermal and subcutaneous connective tissue leading to sclerosis. Sclerosis of the skin can lead to dysmorphism, contractures and restrictions of movement.
Conceptual Design, Neutronic and Radioprotection Study of a Fast Neutron Irradiation Station at SINQ
Resumo:
OBJECTIVE: To describe an ultrasonic surgical aspirator assisted disk fenestration technique in dogs. STUDY DESIGN: Descriptive cadaveric and prospective clinical study. ANIMALS: Fresh Beagle cadavers (n=5) and 10 chondrodystrophic dogs with thoracolumbar disk extrusion. METHODS: Cadaveric study: Intervertebral disks T12-L2 were fenestrated with the CUSA Excel in 5 Beagle cadavers, and fenestration efficacy assessed by morphologic examination of the completeness of fenestration and size of annulotomy. Clinical study: the affected intervertebral disk was fenestrated in 10 chondrodystrophic dogs treated by hemilaminectomy for thoracolumbar disk disease. Efficacy of fenestration was evaluated. RESULTS: Mean time necessary to perform CUSA assisted fenestration was 8 minutes (range, 5-10 minutes) for each disk in cadavers and patients. In cadaver spines, removal of the nucleus pulposus was complete in 11/15 disks. In 4 disks, remnants of nucleus pulposus material were observed on the contralateral side. Nuclear material was normal in 9/15 disks and showed evidence of chondroid degeneration on histopathologic examination in the 6 disks. Median annulotomy size was 3 mm. Clinically, no signs of early recurrence were observed and all dogs recovered uneventfully. CONCLUSIONS: CUSA assisted fenestration is a safe and efficient method of fenestration for removal of most of the nucleus pulposus through a limited annulotomy.
Resumo:
Abstract Purpose: To further evaluate the use of microbeam irradiation (MBI) as a potential means of non-invasive brain tumor treatment by investigating the induction of a bystander effect in non-irradiated tissue. Methods: Adult rats were irradiated with 35 or 350 Gy at the European Synchotron Research Facility (ESRF), using homogenous (broad beam) irradiation (HI) or a high energy microbeam delivered to the right brain hemisphere only. The proteome of the frontal lobes were then analyzed using two-dimensional electrophoresis (2-DE) and mass spectrometry. Results: HI resulted in proteomic responses indicative of tumourigenesis; increased albumin, aconitase and triosphosphate isomerase (TPI), and decreased dihydrolipoyldehydrogenase (DLD). The MBI bystander effect proteomic changes were indicative of reactive oxygen species mediated apoptosis; reduced TPI, prohibitin and tubulin and increased glial fibrillary acidic protein (GFAP). These potentially anti-tumourigenic apoptotic proteomic changes are also associated with neurodegeneration. However the bystander effect also increased heat shock protein (HSP) 71 turnover. HSP 71 is known to protect against all of the neurological disorders characterized by the bystander effect proteome changes. Conclusions: These results indicate that the collective interaction of these MBI-induced bystander effect proteins and their mediation by HSP 71, may confer a protective effect which now warrants additional experimental attention.
Resumo:
Laser tissue welding and soldering is being increasingly used in the clinical setting for defined surgical procedures. The exact induced changes responsible for tensile strength are not yet fully investigated. To further improve the strength of the bonding, a better understanding of the laser impact at the subcellular level is necessary. The goal of this study was to analyze whether the effect of laser irradiation on covalent bonding in pure collagen using irradiances typically applied for tissue soldering. Pure rabbit and equine type I collagen were subjected to laser irradiation. In the first part of the study, rabbit and equine collagen were compared using identical laser and irradiation settings. In the second part of the study, equine collagen was irradiated at increasing laser powers. Changes in covalent bonding were studied indirectly using the sodium dodecylsulfate polyacrylamide gel electrophoresis (SDS-PAGE) technique. Tensile strengths of soldered membranes were measured with a calibrated tensile force gauge. In the first experiment, no differences between the species-specific collagen bands were noted, and no changes in banding were found on SDS-PAGE after laser irradiation. In the second experiment, increasing laser irradiation power showed no effect on collagen banding in SDS-PAGE. Finally, the laser tissue soldering of pure collagen membranes showed virtually no determinable tensile strength. Laser irradiation of pure collagen at typical power settings and exposure times generally used in laser tissue soldering does not induce covalent bonding between collagen molecules. This is true for both rabbit and equine collagen proveniences. Furthermore, soldering of pure collagen membranes without additional cellular components does not achieve the typical tensile strength reported in native, cell-rich tissues. This study is a first step in a better understanding of laser impact at the molecular level and might prove useful in engineering of combined collagen-soldering matrix membranes for special laser soldering applications.