Microfenestration using the CUSA Excel ultrasonic aspiration system in chondrodystrophic dogs with thoracolumbar disk extrusion: a descriptive cadaveric and clinical study
Data(s) |
2011
|
---|---|
Resumo |
OBJECTIVE: To describe an ultrasonic surgical aspirator assisted disk fenestration technique in dogs. STUDY DESIGN: Descriptive cadaveric and prospective clinical study. ANIMALS: Fresh Beagle cadavers (n=5) and 10 chondrodystrophic dogs with thoracolumbar disk extrusion. METHODS: Cadaveric study: Intervertebral disks T12-L2 were fenestrated with the CUSA Excel in 5 Beagle cadavers, and fenestration efficacy assessed by morphologic examination of the completeness of fenestration and size of annulotomy. Clinical study: the affected intervertebral disk was fenestrated in 10 chondrodystrophic dogs treated by hemilaminectomy for thoracolumbar disk disease. Efficacy of fenestration was evaluated. RESULTS: Mean time necessary to perform CUSA assisted fenestration was 8 minutes (range, 5-10 minutes) for each disk in cadavers and patients. In cadaver spines, removal of the nucleus pulposus was complete in 11/15 disks. In 4 disks, remnants of nucleus pulposus material were observed on the contralateral side. Nuclear material was normal in 9/15 disks and showed evidence of chondroid degeneration on histopathologic examination in the 6 disks. Median annulotomy size was 3 mm. Clinically, no signs of early recurrence were observed and all dogs recovered uneventfully. CONCLUSIONS: CUSA assisted fenestration is a safe and efficient method of fenestration for removal of most of the nucleus pulposus through a limited annulotomy. |
Formato |
application/pdf |
Identificador |
http://boris.unibe.ch/12046/1/Forterre_2011.pdf Forterre, Franck; Dickomeit, Mark; Senn, David; Gorgas, Daniela; Spreng, David (2011). Microfenestration using the CUSA Excel ultrasonic aspiration system in chondrodystrophic dogs with thoracolumbar disk extrusion: a descriptive cadaveric and clinical study. Veterinary surgery, 40(1), pp. 34-9. Oxford: Wiley-Blackwell 10.1111/j.1532-950X.2010.00780.x <http://dx.doi.org/10.1111/j.1532-950X.2010.00780.x> doi:10.7892/boris.12046 info:doi:10.1111/j.1532-950X.2010.00780.x urn:issn:0161-3499 |
Idioma(s) |
eng |
Publicador |
Wiley-Blackwell |
Relação |
http://boris.unibe.ch/12046/ |
Direitos |
info:eu-repo/semantics/restrictedAccess |
Fonte |
Forterre, Franck; Dickomeit, Mark; Senn, David; Gorgas, Daniela; Spreng, David (2011). Microfenestration using the CUSA Excel ultrasonic aspiration system in chondrodystrophic dogs with thoracolumbar disk extrusion: a descriptive cadaveric and clinical study. Veterinary surgery, 40(1), pp. 34-9. Oxford: Wiley-Blackwell 10.1111/j.1532-950X.2010.00780.x <http://dx.doi.org/10.1111/j.1532-950X.2010.00780.x> |
Palavras-Chave | #630 Agriculture |
Tipo |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion PeerReviewed |