4 resultados para UAS Dependability
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Background and objective: Autoaggressive nail disorders span a wide range of clinical changes, but they often remain undiagnosed. This article is intended to help the practitioner to make the correct diagnosis and institute an accepted treatment. Material and method: The patient charts of 1800 patients seen by the author between the years 2000-2011 in 6 different European countries were evaluated using photographs of finger and toenails. Results: The most common condition is onycholysis induced by overzealous manicure. The habit tic of maniacally pushing back the proximal nail fold of one or both thumb nails is frequent and often misdiagnosed. Heller’s median canaliform dystrophy is probably also due to a similar injury mechanism. Onychophagia is relatively com- mon and seen both in children and adults. Onychotillomania is less frequent and almost exclusively seen in adults. Onychotemnomania is even less frequent. Onychoteiromania is sowhere between the latter two habits. Onychodaknomania is exceptional and usually a sign of an underlying psychiatric disorder. There was no substantial difference in the prevalence of these conditions among the different countries visited. Conclusions: Auto aggressive nail injury is common, but often difficult to diagnose. Patient care requires not only an in-depth knowledge of virtually all nail diseases, but also a cautious and empathic patient examination and treatment
Resumo:
In this article, the Society for Personality and Social Psychology (SPSP) Task Force on Publication and Research Practices offers a brief statistical primer and recommendations for improving the dependability of research. Recommendations for research practice include (a) describing and addressing the choice of N (sample size) and consequent issues of statistical power, (b) reporting effect sizes and 95% confidence intervals (CIs), (c) avoiding “questionable research practices” that can inflate the probability of Type I error, (d) making available research materials necessary to replicate reported results, (e) adhering to SPSP’s data sharing policy, (f) encouraging publication of high-quality replication studies, and (g) maintaining flexibility and openness to alternative standards and methods. Recommendations for educational practice include (a) encouraging a culture of “getting it right,” (b) teaching and encouraging transparency of data reporting, (c) improving methodological instruction, and (d) modeling sound science and supporting junior researchers who seek to “get it right.”
Resumo:
Abstract Background: The aim of this study was to examine mechanical, microbiologic, and morphologic changes of the appendicle rim to assess if it is appropriate to dissect the appendix with the ultrasound-activated scalpel (UAS) during laparoscopic appendectomy. Materials and Methods: After laparoscopic resection of the appendix, using conventional Roeder slings, we investigated 50 appendicle rims with an in vitro procedure. The overall time of dissection of the mesoappendix with UAS was noted. Following removal, the appendix was dissected in vitro with the UAS one cme from the resection rim. Seal-burst pressures were recorded. Bacterial cultures of the UAS-resected rim were compared with those of the scissors resected rim. Tissue changes were quantified histologically with hematoxylin and eosin (HE) stains. Results: The average time to dissect the mesoappendix was 228 seconds (25-900). Bacterial culture growths were less in the UAS-resected probes (7 versus 36 positive probes; (p > 0.01). HE-stained tissues revealed mean histologic changes in the lamina propria muscularis externa of 2 mm depth. The seal-burst pressure levels of the appendicle lumen had a mean of 420 mbar. Seal-burst pressures and depths of histologic changes were not dependent on the different stages of appendicitis investigated, gender, or age groups. Seal-burst pressure levels were not related to different depths of tissue changes (P = 0.64). Conclusions: The UAS is a rapid instrument for laparoscopic appendectomy and appears to be safe with respect to stability, sterility and tissue changes. It avoids complex time consuming instrument change manoeuvres and current transmission, which may induce intra- and postoperative complications. Our results suggest that keeping a safety margin of at least 5 mm from the bowel would be sufficient to avoid thermal damage.
Resumo:
CRISPR/Cas9-mediated targeted mutagenesis allows efficient generation of loss-of-function alleles in zebrafish. To date this technology has been primarily used to generate genetic knockout animals. Nevertheless, the study of the function of certain loci might require tight spatiotemporal control of gene inactivation. Here, we show that tissue-specific gene disruption can be achieved by driving Cas9 expression with the Gal4/UAS system. Furthermore, by combining the Gal4/UAS and Cre/loxP systems, we establish a versatile tool to genetically label mutant cell clones, enabling their phenotypic analysis. Our technique has the potential to be applied to diverse model organisms, enabling tissue-specific loss-of-function and phenotypic characterization of live and fixed tissues.