26 resultados para Spatial multi-beam module

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, we report on an optical tolerance analysis of the submillimeter atmospheric multi-beam limb sounder, STEAMR. Physical optics and ray-tracing methods were used to quantify and separate errors in beam pointing and distortion due to reflector misalignment and primary reflector surface deformations. Simulations were performed concurrently with the manufacturing of a multi-beam demonstrator of the relay optical system which shapes and images the beams to their corresponding receiver feed horns. Results from Monte Carlo simulations show that the inserts used for reflector mounting should be positioned with an overall accuracy better than 100 μm (~ 1/10 wavelength). Analyses of primary reflector surface deformations show that a deviation of magnitude 100 μm can be tolerable before deployment, whereas the corresponding variations should be less than 30 μm during operation. The most sensitive optical elements in terms of misalignments are found near the focal plane. This localized sensitivity is attributed to the off-axis nature of the beams at this location. Post-assembly mechanical measurements of the reflectors in the demonstrator show that alignment better than 50 μm could be obtained.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, we present a novel technique for the removal of astigmatism in submillimeter-wave optical systems through employment of a specific combination of so-called astigmatic off-axis reflectors. This technique treats an orthogonally astigmatic beam using skew Gaussian beam analysis, from which an anastigmatic imaging network is derived. The resultant beam is considered truly stigmatic, with all Gaussian beam parameters in the orthogonal directions being matched. This is thus considered an improvement over previous techniques wherein a beam corrected for astigmatism has only the orthogonal beam amplitude radii matched, with phase shift and phase radius of curvature not considered. This technique is computationally efficient, negating the requirement for computationally intensive numerical analysis of shaped reflector surfaces. The required optical surfaces are also relatively simple to implement compared to such numerically optimized shaped surfaces. This technique is implemented in this work as part of the complete optics train for the STEAMR antenna. The STEAMR instrument is envisaged as a mutli-beam limb sounding instrument operating at submillimeter wavelengths. The antenna optics arrangement for this instrument uses multiple off-axis reflectors to control the incident radiation and couple them to their corresponding receiver feeds. An anastigmatic imaging network is successfully implemented into an optical model of this antenna, and the resultant design ensures optimal imaging of the beams to the corresponding feed horns. This example also addresses the challenges of imaging in multi-beam antenna systems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes sideband response measurements and atmospheric observations with a double sideband and two Single Sideband (SSB) receiver prototypes developed for the multi-beam limb sounder instrument stratosphere-troposphere exchange and climate monitor radiometer. We first show an advanced Fourier-Transform Spectroscopy (FTS) method for sideband response and spurious signal characterization. We then present sideband response measurements of the different prototype receivers and we compare the results of the SSB receivers with sideband measurements by injecting a continuous wave signal into the upper and lower sidebands. The receivers were integrated into a total-power radiometer and atmospheric observations were carried out. The observed spectra were compared to forward model spectra to conclude on the sideband characteristics of the different receivers. The two sideband characterization methods show a high degree of agreement for both SSB receivers with various local oscillator settings. The measured sideband response was used to correct the forward model simulations. This improves the agreement with the atmospheric observations and explains spectral features caused by an unbalanced sideband response. The FTS method also allows to quantify the influence of spurious harmonic responses of the receiver.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Heterodyne receivers at millimeter and submillimeter wavelength are widely used for radiometric spectral line observations for atmospheric remote sensing or radio astronomy. The quantitative analysis of such observations requires an accurate knowledge of the mixers's sideband ratio. In addition, its potential sensitivity to spurious harmonics needs to be well understood. In this paper, we discuss a measurement technique for these receiver characteristics, which is based on a scanning Martin Puplett Interferometer used in conjunction with a wide band digital autocorrelation spectrometer for the analysis of the intermediate frequency band. We present measurement results of different double sideband and sideband separating mixers, which were developed for the proposed 340GHz multi-beam limb sounder STEAMR.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

To determine the outcome of patients with brain metastasis (BM) from lung cancer treated with an external beam radiotherapy boost (RTB) after whole brain radiotherapy (WBRT).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In order to study further the long-range correlations ("ridge") observed recently in p+Pb collisions at sqrt(s_NN) =5.02 TeV, the second-order azimuthal anisotropy parameter of charged particles, v_2, has been measured with the cumulant method using the ATLAS detector at the LHC. In a data sample corresponding to an integrated luminosity of approximately 1 microb^(-1), the parameter v_2 has been obtained using two- and four-particle cumulants over the pseudorapidity range |eta|<2.5. The results are presented as a function of transverse momentum and the event activity, defined in terms of the transverse energy summed over 3.1spatial extent of the p+Pb collision system, the large magnitude of v_2 and its similarity to hydrodynamic predictions provide additional evidence for the importance of final-state effects in p+Pb reactions.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A detector based on doped silica and optical fibers was developed to monitor the profile of particle accelerator beams of intensity ranging from 1 pA to tens of µA. Scintillation light produced in a fiber moving across the beam is measured, giving information on its position, shape and intensity. The detector was tested with a continuous proton beam at the 18 MeV Bern medical cyclotron used for radioisotope production and multi-disciplinary research. For currents from 1 pA to 20 µA, Ce3+ and Sb3+ doped silica fibers were used as sensors. Read out systems based on photodiodes, photomultipliers and solid state photomultipliers were employed. Profiles down to the pA range were measured with this method for the first time. For currents ranging from 1 pA to 3 µA, the integral of the profile was found to be linear with respect to the beam current, which can be measured by this detector with an accuracy of ∼1%. The profile was determined with a spatial resolution of 0.25 mm. For currents ranging from 5 µA to 20 µA, thermal effects affect light yield and transmission, causing distortions of the profile and limitations in monitoring capabilities. For currents higher than ∼1 µA, non doped optical fibers for both producing and transporting scintillation light were also successfully employed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A spatial, electro-optical autocorrelation (EOA) interferometer using the vertically polarized lobes of coherent transition radiation (CTR) has been developed as a single-shot electron bunch length monitor at an optical beam port downstream the 100 MeV preinjector LINAC of the Swiss Light Source. This EOA monitor combines the advantages of step-scan interferometers (high temporal resolution) [D. Mihalcea et al., Phys. Rev. ST Accel. Beams 9, 082801 (2006) and T. Takahashi and K. Takami, Infrared Phys. Technol. 51, 363 (2008)] and terahertz-gating technologies [U. Schmidhammer et al., Appl. Phys. B: Lasers Opt. 94, 95 (2009) and B. Steffen et al., Phys. Rev. ST Accel. Beams 12, 032802 (2009)] (fast response), providing the possibility to tune the accelerator with an online bunch length diagnostics. While a proof of principle of the spatial interferometer was achieved by step-scan measurements with far-infrared detectors, the single-shot capability of the monitor has been demonstrated by electro-optical correlation of the spatial CTR interference pattern with fairly long (500 ps) neodymium-doped yttrium aluminum garnet (Nd:YAG) laser pulses in a ZnTe crystal. In single-shot operation, variations of the bunch length between 1.5 and 4 ps due to different phase settings of the LINAC bunching cavities have been measured with subpicosecond time resolution.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

External beam proton radiation therapy has been used since 1975 to treat choroidal melanoma. For tumor location determination during proton radiation treatment, surgical tantalum clips are registered with image data. This report introduces the intraoperative application of an opto-electronic navigation system to determine with high precision the position of the tantalum markers and their spatial relationship to the tumor and anatomical landmarks. The application of the technique in the first 4 patients is described.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To compare diagnostic accuracy of multi-station, high-spatial resolution contrast-enhanced MR angiography (CE-MRA) of the lower extremities with digital subtraction angiography (DSA) as the reference standard in patients with symptomatic peripheral arterial occlusive disease. MATERIALS AND METHODS: Of 485 consecutive patients undergoing a run-off CE-MRA, 152 patients (86 male, 66 female; mean age, 71.6 years) with suspected peripheral arterial occlusive disease were included into our Institutional Review Board approved study. All patients underwent MRA and DSA of the lower extremities within 30 days. MRA was performed at 1.5 Tesla with a single bolus of 0.1 mmol/kg body weight of gadobutrol administered at a rate of 2.0 mL/s at three stations. Two readers evaluated the MRA images independently for stenosis grade and image quality. Sensitivity and specificity were derived. RESULTS: Sensitivity and specificity ranged from 73% to 93% and 64% to 89% and were highest in the thigh area. Both readers showed comparable results. Evaluation of good and better quality MRAs resulted in a considerable improvement in diagnostic accuracy. CONCLUSION: Contrast-enhanced MRA demonstrates good sensitivity and specificity in the investigation of the vasculature of the lower extremities. While a minor investigator experience dependence remains, it is standardizable and shows good inter-observer agreement. Our results confirm that the administration of Gadobutrol at a standard dose of 0.1 mmol/kg for contrast-enhanced runoff MRA is able to detect hemodynamically relevant stenoses. Use of contrast-enhanced MRA as an alternative to intra-arterial DSA in the evaluation and therapeutic planning of patients with suspected peripheral arterial occlusive disease is well justified. J. Magn. Reson. Imaging 2013;37:1427-1435. © 2012 Wiley Periodicals, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In order to explore the genetic diversity within Echinococcus multilocularis (E. multilocularis), the cestode responsible for the alveolar echinococcosis (AE) in humans, a microsatellite, composed of (CA) and (GA) repeats and designated EmsB, was isolated and characterized in view of its nature and potential field application. PCR-amplification with specific primers exhibited a high degree of size polymorphism between E. multilocularis and Echinococcus granulosus sheep (G1) and camel (G6) strains. Fluorescent-PCR was subsequently performed on a panel of E. multilocularis isolates to assess intra-species polymorphism level. EmsB provided a multi-peak profile, characterized by tandemly repeated microsatellite sequences in the E. multilocularis genome. This "repetition of repeats" feature provided to EmsB a high discriminatory power in that eight clusters, supported by bootstrap p-values larger than 95%, could be defined among the tested E. multilocularis samples. We were able to differentiate not only the Alaskan from the European samples, but also to detect different European isolate clusters. In total, 25 genotypes were defined within 37 E. multilocularis samples. Despite its complexity, this tandem repeated multi-loci microsatellite possesses the three important features for a molecular marker, i.e. sensitivity, repetitiveness and discriminatory power. It will permit assessing the genetic polymorphism of E. multilocularis and to investigate its spatial distribution in detail.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Currently photon Monte Carlo treatment planning (MCTP) for a patient stored in the patient database of a treatment planning system (TPS) can usually only be performed using a cumbersome multi-step procedure where many user interactions are needed. This means automation is needed for usage in clinical routine. In addition, because of the long computing time in MCTP, optimization of the MC calculations is essential. For these purposes a new graphical user interface (GUI)-based photon MC environment has been developed resulting in a very flexible framework. By this means appropriate MC transport methods are assigned to different geometric regions by still benefiting from the features included in the TPS. In order to provide a flexible MC environment, the MC particle transport has been divided into different parts: the source, beam modifiers and the patient. The source part includes the phase-space source, source models and full MC transport through the treatment head. The beam modifier part consists of one module for each beam modifier. To simulate the radiation transport through each individual beam modifier, one out of three full MC transport codes can be selected independently. Additionally, for each beam modifier a simple or an exact geometry can be chosen. Thereby, different complexity levels of radiation transport are applied during the simulation. For the patient dose calculation, two different MC codes are available. A special plug-in in Eclipse providing all necessary information by means of Dicom streams was used to start the developed MC GUI. The implementation of this framework separates the MC transport from the geometry and the modules pass the particles in memory; hence, no files are used as the interface. The implementation is realized for 6 and 15 MV beams of a Varian Clinac 2300 C/D. Several applications demonstrate the usefulness of the framework. Apart from applications dealing with the beam modifiers, two patient cases are shown. Thereby, comparisons are performed between MC calculated dose distributions and those calculated by a pencil beam or the AAA algorithm. Interfacing this flexible and efficient MC environment with Eclipse allows a widespread use for all kinds of investigations from timing and benchmarking studies to clinical patient studies. Additionally, it is possible to add modules keeping the system highly flexible and efficient.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Monte Carlo (code GEANT) produced 6 and 15 MV phase space (PS) data were used to define several simple photon beam models. For creating the PS data the energy of starting electrons hitting the target was tuned to get correct depth dose data compared to measurements. The modeling process used the full PS information within the geometrical boundaries of the beam including all scattered radiation of the accelerator head. Scattered radiation outside the boundaries was neglected. Photons and electrons were assumed to be radiated from point sources. Four different models were investigated which involved different ways to determine the energies and locations of beam particles in the output plane. Depth dose curves, profiles, and relative output factors were calculated with these models for six field sizes from 5x5 to 40x40cm2 and compared to measurements. Model 1 uses a photon energy spectrum independent of location in the PS plane and a constant photon fluence in this plane. Model 2 takes into account the spatial particle fluence distribution in the PS plane. A constant fluence is used again in model 3, but the photon energy spectrum depends upon the off axis position. Model 4, finally uses the spatial particle fluence distribution and off axis dependent photon energy spectra in the PS plane. Depth dose curves and profiles for field sizes up to 10x10cm2 were not model sensitive. Good agreement between measured and calculated depth dose curves and profiles for all field sizes was reached for model 4. However, increasing deviations were found for increasing field sizes for models 1-3. Large deviations resulted for the profiles of models 2 and 3. This is due to the fact that these models overestimate and underestimate the energy fluence at large off axis distances. Relative output factors consistent with measurements resulted only for model 4.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present the first 7500 yr long multi-proxy record from a raised bog located at the southern Baltic coast, Poland. Testate amoebae, plant macrofossils, pollen and microscopic charcoal were used to reconstruct environmental changes in Pomerania (northern Poland, Kaszuby Lakeland) from a 7-m thick peat archive of Stążki bog dated 5500 BC–AD 1250. We obtained a record of proxies representing different spatial scales: regional vegetation changed simultaneously with local vegetation, and testate amoebae showed a pattern of change similar to that of pollen and plant macrofossils. On the basis of the combined proxies, we distinguished three hydroclimatic stages: moist conditions 5500–3450 BC, drier conditions with regionally increased fires up to 600 BC, and again moist conditions from 600 BC onward. During the drier interval, a first climatic shift to wetter conditions at 1700 BC is indicated by regional pollen as the replacement of Corylus by Carpinus, and locally by, e.g., the increase of Hyalosphenia elegans and mire plants such as Sphagnum sec. Cuspidata. Furthermore, we observed a correlation since 600 BC among the re-expansion of Carpinus (after a sudden decline ca. 950 BC), increased peat accumulation, increase of Hyalosphenia species, and fewer fires, suggesting lower evapotranspiration and a stable high water table in the bog. Fagus started to expand after AD 810 gradually replacing Carpinus, which was possibly due to a gradually more oceanic climate, though we cannot exclude human impact on the forests. Peat accumulation, determined by radiocarbon dating, varied with bog surface wetness. The hydroclimatic phases found in Stążki peatland are similar to moisture changes recorded in other sites from Poland and Europe. This is the first detailed record of hydroclimatic change during the Holocene in the southern Baltic region, so it forms a reference site for further studies on other southern Baltic bogs that are in progress.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Long term quality of life data of adult patients harboring intracranial ependymomas have not been reported. The role of adjuvant radiation therapy in Grade II ependymomas is unclear and differs from study to study. We therefore sought to retrospectively analyze outcome and quality of life of adult patients that were operated on intracranial ependymomas at four different surgical centers in two countries. All patients were attempted to be contacted via telephone to assess quality of life (QoL) at the time of the telephone interview. The standard EORTC QoL Questionnaire C30 (EORTC QLQ-C30) and the EORTC QLQ-Brain Cancer Module (QLQ-BN20) were used. 64 adult patients with intracranial ependymomas were included in the study. The only factor that was associated with increased survival was age <55 years (p < 0.001). Supratentorial location was correlated with shorter progression free survival than infratentorial location (PFS; p = 0.048). In WHO Grade II tumors local irradiation did not lead to increased PFS (p = 0.888) or overall survival (p = 0.801). Even for incompletely resected Grade II tumors local irradiation did not lead to a benefit in PFS (p = 0.911). In a multivariate analysis of QoL, irradiated patients had significantly worse scores in the item "fatigue" (p = 0.037) than non-irradiated patients. Here we present QoL data of adult patients with intracranial ependymomas. Our data show that local radiation therapy may have long-term effects on patients' QoL. Since in the incompletely resected Grade II tumors local irradiation did not lead to a benefit in PFS in this retrospective study, prospective randomized studies are necessary. In addition to age, supratentorial tumor location is associated with a worse prognosis in adult ependymoma patients.