290 resultados para SUPRACONDYLAR FEMORAL FRACTURES
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
BACKGROUND: Percutaneous Kirschner wire fixation represents the classic treatment for displaced supracondylar humeral fractures in childhood. This type of treatment first requires satisfactory reduction of the fracture. Failure to achieve a satisfactory reduction or inadequate stabilization can result in instability of the fracture fragments, which can result in either an unsatisfactory cosmetic or functional outcome. In our experience, these problems can be overcome with the use of a small lateral external fixator. METHODS: Between 1999 and 2005, thirty-one of 170 Gartland type-III supracondylar humeral fractures were treated with a lateral external fixator. The outcome of treatment was analyzed with regard to limb alignment, elbow movement, cosmetic appearance, and patient satisfaction. RESULTS: In twenty-eight of the thirty-one patients, a satisfactory reduction was achieved with closed methods. All children except one had a normal or good range of movement. The cosmetic result was excellent in all cases. All of the children and their parents stated that they would choose this treatment again. CONCLUSIONS: The use of a small lateral external fixator seems to be a safe alternative for the treatment of displaced supracondylar fractures of the humerus when a closed reduction appears to be unattainable by means of manipulation alone or when sufficient stability is not achieved with standard methods of Kirschner wire fixation.
Resumo:
BACKGROUND Closed reduction and pinning is the accepted treatment choice for dislocated supracondylar humeral fractures in children (SCHF). Rates of open reduction, complications and outcome are reported to be dependent on delay of surgery. We investigated whether delay of surgery had influence on the incidence of open reduction, complications and outcome of surgical treatment of SCHFs in the authors' institution. METHODS Three hundred and forty-one children with 343 supracondylar humeral fractures (Gartland II: 144; Gartland III: 199) who underwent surgery between 2000 and 2009 were retrospectively analysed. The group consisted of 194 males and 149 females. The average age was 6.3 years. Mean follow-up was 6.2 months. Time interval between trauma and surgical intervention was determined using our institutional database. Clinical and radiographical data were collected for each group. Influence of delay of treatment on rates of open reduction, complications and outcome was calculated using logistic regression analysis. Furthermore, patients were grouped into 4 groups of delay (<6 h, n = 166; 6-12 h, n = 95; 12-24 h, n = 68; >24 h, n = 14) and the aforementioned variables were compared among these groups. RESULTS The incidence of open procedures in 343 supracondylar humeral fractures was 2.6 %. Complication rates were similar to the literature (10.8 %) primarily consisting of transient neurological impairments (9.0 %) which all were fully reversible by conservative treatment. Poor outcome was seen in 1.7 % of the patients. Delay of surgical treatment had no influence on rates of open surgery (p = 0.662), complications (p = 0.365) or poor outcome (p = 0.942). CONCLUSIONS In this retrospective study delay of treatment of SCHF did not have significant influence on the incidence of open reduction, complications, and outcome. Therefore, in SCHF with sufficient blood perfusion and nerve function, elective treatment is reasonable to avoid surgical interventions in the middle of the night which are stressful and wearing both for patients and for surgeons. LEVEL OF EVIDENCE III (retrospective comparative study).
Resumo:
End caps are intended to prevent nail migration (push-out) in elastic stable intramedullary nailing. The aim of this study was to investigate the force at failure with and without end caps, and whether different insertion angles of nails and end caps would alter that force at failure. Simulated oblique fractures of the diaphysis were created in 15 artificial paediatric femurs. Titanium Elastic Nails with end caps were inserted at angles of 45°, 55° and 65° in five specimens for each angle to create three study groups. Biomechanical testing was performed with axial compression until failure. An identical fracture was created in four small adult cadaveric femurs harvested from two donors (both female, aged 81 and 85 years, height 149 cm and 156 cm, respectively). All femurs were tested without and subsequently with end caps inserted at 45°. In the artificial femurs, maximum force was not significantly different between the three groups (p = 0.613). Push-out force was significantly higher in the cadaveric specimens with the use of end caps by an up to sixfold load increase (830 N, standard deviation (SD) 280 vs 150 N, SD 120, respectively; p = 0.007). These results indicate that the nail and end cap insertion angle can be varied within 20° without altering construct stability and that the risk of elastic stable intramedullary nailing push-out can be effectively reduced by the use of end caps.
Resumo:
The aim of this study was to evaluate the ability of dual energy X-rays absorptiometry (DXA) areal bone mineral density (aBMD) measured in different regions of the proximal part of the human femur for predicting the mechanical properties of matched proximal femora tested in two different loading configurations. 36 pairs of fresh frozen femora were DXA scanned and tested until failure in two loading configurations: a fall on the side or a one-legged standing. The ability of the DXA output from four different regions of the proximal femur in predicting the femoral mechanical properties was measured and compared for the two loading scenarios. The femoral neck DXA BMD was best correlated to the femoral ultimate force for both configurations and predicted significantly better femoral failure load (R2=0.80 vs. R2=0.66, P<0.05) when simulating a side than when simulating a standing configuration. Conversely, the work to failure was predicted similarly for both loading configurations (R2=0.54 vs. R2=0.53, P>0.05). Therefore, neck BMD should be considered as one of the key factors for discriminating femoral fracture risk in vivo. Moreover, the better predictive ability of neck BMD for femoral strength if tested in a fall compared to a one-legged stance configuration suggests that DXA's clinical relevance may not be as high for spontaneous femoral fractures than for fractures associated to a fall.
Resumo:
OBJECTIVE Precise adaptable fixation of a supracondylar humerus osteotomy with a radial/lateral external fixator to correct posttraumatic cubitus varus. INDICATIONS Acquired, posttraumatic cubitus varus as a result of a malhealed and unsatisfactorily treated supracondylar humerus fracture. Idiopathic, congenital cubitus varus (very seldom) if the child (independent of age and after complete healing) is cosmetically impaired; stability of the elbow is reduced due to malalignment (hyperextension); secondary problems and pain (e. g., irritation of the ulnar nerve) are expected or already exist; or there is an explicit wish of the child/parents (relative indication). CONTRAINDICATIONS In principle there are no contraindications provided that the indication criteria are filled. The common argument of age does not represent a contraindication in our opinion, since angular remodeling at the distal end of the humerus is practically nonexistent. SURGICAL TECHNIQUE Basically, the surgical technique of the radial external fixator is used as previously described for stabilization of complex supracondylar humeral fractures. With the patient in supine position, the arm is placed freely on an arm table. Using a 4-5 cm long skin incision along the radial, supracondylar, the extracapsular part of the distal humerus is prepared, whereby great caution regarding the radial nerve is advised. In contrast to the procedure used in radial external fixation for supracondylar humeral fracture treatment, two Schanz screws are always fixed in each fragment at a distance of 1.5-2 cm. The osteotomy must allow the fragment to freely move in all directions. The proximal and distal two Schanz screws are then connected with short 4 mm carbon or stainless steel rods. These two rods are connected with each other over another rod using the tub-to-tub technique. Now the preliminary correction according the clinical situation can be performed and the clamps are tightened. Anatomical axis and function are checked. If these are radiologically and clinically perfect, all clamps are definitively tightened; if the alignment or the function is not perfect, then further adjustments can be made. POSTOPERATIVE MANAGEMENT Due to the excellent stability, further immobilization not necessary. Immediate functional follow-up treatment performed according to pain. RESULTS Adequate healing is usually expected within 6 weeks. At this time the external fixator can be removed in the fracture clinic. Because the whole operation is performed in an extraarticular manner and the mobility of the elbow is not affected, deterioration of function has never been observed. Also regarding the cosmetic/anatomical situation, good results are expected because they were already achieved intraoperatively.
Resumo:
Rebound-associated vertebral fractures may follow treatment discontinuation of highly potent reversible bone antiresorptives, resulting from the synergy of rapid bone resorption and accelerated microdamage accumulation in trabecular bone. INTRODUCTION The purposes of this study are to characterize rebound-associated vertebral fractures following the discontinuation of a highly potent reversible antiresorptive therapy based on clinical observation and propose a pathophysiological rationale. METHODS This study is a case report of multiple vertebral fractures early after discontinuation of denosumab therapy in a patient with hormone receptor-positive non-metastatic breast cancer treated with an aromatase inhibitor. RESULTS Discontinuation of highly potent reversible bone antiresorptives such as denosumab may expose patients to an increased fracture risk due to the joined effects of absent microdamage repair during therapy followed by synchronous excess activation of multiple bone remodelling units at the time of loss-of-effect. We suggest the term rebound-associated vertebral fractures (RVF) for this phenomenon characterized by the presence of multiple new clinical vertebral fractures, associated with either no or low trauma, in a context consistent with the presence of high bone turnover and rapid loss of lumbar spine bone mineral density (BMD) occurring within 3 to 12 months after discontinuation (loss-of-effect) of a reversible antiresorptive therapy in the absence of secondary causes of bone loss or fractures. Unlike atypical femoral fractures that emerge from failure of microdamage repair in cortical bone with long-term antiresorptive treatment, RVF originate from the synergy of rapid bone resorption and accelerated microdamage accumulation in trabecular bone triggered by the discontinuation of highly potent reversible antiresorptives. CONCLUSIONS Studies are urgently needed to i) prove the underlying pathophysiological processes suggested above, ii) establish the predictive criteria exposing patients to an increased risk of RVF, and iii) determine appropriate treatment regimens to be applied in such patients.