11 resultados para Quality Evaluation

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tandem mass spectral libraries are gaining more and more importance for the identification of unknowns in different fields of research, including metabolomics, forensics, toxicology, and environmental analysis. Particularly, the recent invention of reliable, robust, and transferable libraries has increased the general acceptance of these tools. Herein, we report on results obtained from thorough evaluation of the match reliabilities of two tandem mass spectral libraries: the MSforID library established by the Oberacher group in Innsbruck and the Weinmann library established by the Weinmann group in Freiburg. Three different experiments were performed: (1) Spectra of the libraries were searched against their corresponding library after excluding either this single compound-specific spectrum or all compound-specific spectra prior to searching; (2) the libraries were searched against each other using either library as reference set or sample set; (3) spectra acquired on different mass spectrometric instruments were matched to both libraries. Almost 13,000 tandem mass spectra were included in this study. The MSforID search algorithm was used for spectral matching. Statistical evaluation of the library search results revealed that principally both libraries enable the sensitive and specific identification of compounds. Due to higher mass accuracy of the QqTOF compared with the QTrap instrument, matches to the MSforID library were more reliable when comparing spectra with both libraries. Furthermore, only the MSforID library was shown to be efficiently transferable to different kinds of tandem mass spectrometers, including "tandem-in-time" instruments; this is due to the coverage of a large range of different collision energy settings-including the very low range-which is an outstanding characteristics of the MSforID library.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE To investigate the quality of the data disseminated via the Internet regarding pain experienced by orthodontic patients. MATERIALS AND METHODS A systematic online search was performed for 'orthodontic pain' and 'braces pain' separately using five search engines. The first 25 results from each search term-engine combination were pooled for analysis. After excluding advertising sites, discussion groups, video feeds, and links to scientific articles, 25 Web pages were evaluated in terms of accuracy, readability, accessibility, usability, and reliability using recommended research methodology; reference textbook material, the Flesch Reading Ease Score; and the LIDA instrument. Author and information details were also recorded. RESULTS Overall, the results indicated a variable quality of the available informational material. Although the readability of the Web sites was generally acceptable, the individual LIDA categories were rated of medium or low quality, with average scores ranging from 16.9% to 86.2%. The orthodontic relevance of the Web sites was not accompanied by the highest assessment results, and vice versa. CONCLUSIONS The quality of the orthodontic pain information cited by Web sources appears to be highly variable. Further structural development of health information technology along with public referral to reliable sources by specialists are recommended.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Data on antimicrobial use play a key role in the development of policies for the containment of antimicrobial resistance. On-farm data could provide a detailed overview of the antimicrobial use, but technical and methodological aspects of data collection and interpretation, as well as data quality need to be further assessed. The aims of this study were (1) to quantify antimicrobial use in the study population using different units of measurement and contrast the results obtained, (2) to evaluate data quality of farm records on antimicrobial use, and (3) to compare data quality of different recording systems. During 1 year, data on antimicrobial use were collected from 97 dairy farms. Antimicrobial consumption was quantified using: (1) the incidence density of antimicrobial treatments; (2) the weight of active substance; (3) the used daily dose and (4) the used course dose for antimicrobials for intestinal, intrauterine and systemic use; and (5) the used unit dose, for antimicrobials for intramammary use. Data quality was evaluated by describing completeness and accuracy of the recorded information, and by comparing farmers' and veterinarians' records. Relative consumption of antimicrobials depended on the unit of measurement: used doses reflected the treatment intensity better than weight of active substance. The use of antimicrobials classified as high priority was low, although under- and overdosing were frequently observed. Electronic recording systems allowed better traceability of the animals treated. Recording drug name or dosage often resulted in incomplete or inaccurate information. Veterinarians tended to record more drugs than farmers. The integration of veterinarian and farm data would improve data quality.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The quality of husbandry of Franches-Montagnes horses (FM) in Switzerland is evaluated on the basis of an investigation carried out in 2002 by the Swiss FM breeding federation. Questionnaires were sent to 3500 of its members and the results include data from 968 breeding enterprises, housing a total of 3965 FM: 46.1% were breeding mares (61.0% with foal at foot), 26.5% young stock, 1.3% stallions and 26.0% non breeding stock (74.6% of which were pleasure horses and 25.4% working horses). 57.6% of the FM were housed in individual boxes with or without permanent outdoor access, 25.4% were hold in groups with or without permanent outdoor access, the remaining 17.0% were kept in standing stalls. 95.0% of the FM had at least visual contact with other equines and 99.2% had sufficient light in their stable. 88.1% were stabled on long stalk straw, while only 4.3% were bedded on other materials other than straw. The average time spent at pasture per horse and per week ranged from 96.5 +/- 51.6 hours in summer to 27.2 +/- 26.7 hours in winter. On average, a FM is used for 8.3 +/- 6.5 hours per week. Horses with an paddock at their disposal spend an average of 39.8 +/- 45.9 hours there per week.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVES: To assess magnetic resonance (MR)-colonography (MRC) for detection of colorectal lesions using two different T1w three-dimensional (3D)-gradient-recalled echo (GRE)-sequences and integrated parallel data acquisition (iPAT) at a 3.0 Tesla MR-unit. MATERIALS AND METHODS: In this prospective study, 34 symptomatic patients underwent dark lumen MRC at a 3.0 Tesla unit before conventional colonoscopy (CC). After colon distension with tap water, 2 high-resolution T1w 3D-GRE [3-dimensional fast low angle shot (3D-FLASH), iPAT factor 2 and 3D-volumetric interpolated breathhold examination (VIBE), iPAT 3] sequences were acquired without and after bolus injection of gadolinium. Prospective evaluation of MRC was performed. Image quality of the different sequences was assessed qualitatively and quantitatively. The findings of the same day CC served as standard of reference. RESULTS: MRC identified all polyps >5 mm (16 of 16) in size and all carcinomas (4 of 4) correctly. Fifty percent of the small polyps quality was excellent in 94% (384 of 408 colonic segments) using the 3D-FLASH and in 92% (376 of 408) for the VIBE. The 3D-FLASH sequence showed a 3-fold increase in signal-to-noise ratio (8 +/- 3.3 standard deviation (SD) in lesions without contrast enhancement (CE); 24.3 +/- 7.8 SD after CE). For the 3D-VIBE sequence, signal-to-noise ratio doubled in the detected lesions (147 +/- 54 SD without and 292 +/- 168 SD after CE). Although image quality was ranked lower in the VIBE, the image quality score of both sequences showed no statistical significant difference (chi > 0.6). CONCLUSIONS: MRC using 3D-GRE-sequences and iPAT is feasible at 3.0 T-systems. The high-resolution 3D-FLASH was slightly preferred over the 3D-VIBE because of better image quality, although both used sequences showed no statistical significant difference.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVE: To compare anesthesia recovery quality after racemic (R-/S-) or S-ketamine infusions during isoflurane anesthesia in horses. ANIMALS: 10 horses undergoing arthroscopy. PROCEDURES: After administration of xylazine for sedation, horses (n = 5/group) received R-/S-ketamine (2.2 mg/kg) or S-ketamine (1.1 mg/kg), IV, for anesthesia induction. Anesthesia was maintained with isoflurane in oxygen and R-/S-ketamine (1 mg/kg/h) or S-ketamine (0.5 mg/kg/h). Heart rate, invasive mean arterial pressure, and end-tidal isoflurane concentration were recorded before and during surgical stimulation. Arterial blood gases were evaluated every 30 minutes. Arterial ketamine and norketamine enantiomer plasma concentrations were quantified at 60 and 120 minutes. After surgery, horses were kept in a padded recovery box, sedated with xylazine, and video-recorded for evaluation of recovery quality by use of a visual analogue scale (VAS) and a numeric rating scale. RESULTS: Horses in the S-ketamine group had better numeric rating scale and VAS values than those in the R-/S-ketamine group. In the R-/S-ketamine group, duration of infusion was positively correlated with VAS value. Both groups had significant increases in heart rate and mean arterial pressure during surgical stimulation; values in the R-/S-ketamine group were significantly higher than those of the S-ketamine group. Horses in the R-/S-ketamine group required slightly higher end-tidal isoflurane concentration to maintain a surgical plane of anesthesia. Moderate respiratory acidosis and reduced oxygenation were evident. The R-norketamine concentrations were significantly lower than S-norketamine concentrations in the R-/S-ketamine group. CONCLUSIONS AND CLINICAL RELEVANCE: Compared with R-/S-ketamine, anesthesia recovery was better with S-ketamine infusions in horses.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Because of the important morbidity and mortality associated with osteoporosis, it is essential to detect subjects at risk by screening methods, such as bone quantitative ultrasounds (QUSs). Several studies showed that QUS could predict fractures. None, however, compared prospectively different QUS devices, and few data of quality controls (QCs) have been published. The Swiss Evaluation of the Methods of Measurement of Osteoporotic Fracture Risk is a prospective multicenter study that compared three QUSs for the assessment of hip fracture risk in a population of 7609 women age >/=70 yr. Because the inclusion phase lasted 20 mo, and because 10 centers participated in this study, QC became a major issue. We therefore developed a QC procedure to assess the stability and precision of the devices, and for their cross-calibration. Our study focuses on the two heel QUSs. The water bath system (Achilles+) had a higher precision than the dry system (Sahara). The QC results were highly dependent on temperature. QUS stability was acceptable, but Sahara must be calibrated regularly. A sufficient homogeneity among all the Sahara devices could be demonstrated, whereas significant differences were found among the Achilles+ devices. For speed of sound, 52% of the differences among the Achilles+ was explained by the water s temperature. However, for broadband ultrasound attenuation, a maximal difference of 23% persisted after adjustment for temperature. Because such differences could influence measurements in vivo, it is crucial to develop standardized phantoms to be used in prospective multicenter studies.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In the present study, the oral health-related quality of life of 18 patients (13 men and 5 women) was evaluated using validated questionnaires as proposed by the European Organization of Research and Treatment of Cancer (EORTC). The patients belonged to a cohort of 48 patients, whose prosthetic treatment was performed during the years 2004-2007. In the course of tumor resection, 12 patients underwent graft surgery and 14 patients radiotherapy. One patient required a nasal epithesis since resection of the nose became necessary. Five patients underwent a full block resection of the mandible, and tumor resection in 3 patients resulted in a large oronasal communication. Prosthetic rehabilitation was performed in all patients, and the follow-up period with regular care covered a minimum of 3 years. Eleven patients received dental implants for better support and retention of the prostheses. In spite of compromised oral conditions, functional restrictions, and some difficulties with the prostheses, the answers to the questionnaire were quite positive. The majority judged their general health as good or even excellent. The subjective perception of the patients may contradict the objective view by the dentist. In fact, the individual patient's history and experience provide a better understanding of the impact of oral tumors on daily life. The overall assessment identified 4 items that were perceived as major problems by all patients: swallowing solid food, dry mouth, limited mouth opening, and appearance. Prosthetic rehabilitation has only a limited influence on such problems.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The performance of high-resolution CZE for determination of carbohydrate-deficient transferrin (CDT) in human serum based on internal and external quality data gathered over a 10-year period is reported. The assay comprises mixing of serum with a Fe(III) ion-containing solution prior to analysis of the iron saturated mixture in a dynamically double-coated capillary using a commercial buffer at alkaline pH. CDT values obtained with a human serum of a healthy individual and commercial quality control sera are shown to vary less than 10%. Values of a control from a specific lot were found to slowly decrease as function of time (less than 10% per year). Furthermore, due to unknown reasons, gradual changes in the monitored pattern around pentasialo-transferrin were detected, which limit the use of commercial control sera of the same lot to less than 2 years. Analysis of external quality control sera revealed correct classification of the samples over the entire 10-year period. Data obtained compare well with those of HPLC and CZE assays of other laboratories. The data gathered over a 10-year period demonstrate the robustness of the high-resolution CZE assay. This is the first account of a CZE-based CDT assay with complete internal and external quality assessment over an extended time period.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The widespread use of wireless enabled devices and the increasing capabilities of wireless technologies has promoted multimedia content access and sharing among users. However, the quality perceived by the users still depends on multiple factors such as video characteristics, device capabilities, and link quality. While video characteristics include the video time and spatial complexity as well as the coding complexity, one of the most important device characteristics is the battery lifetime. There is the need to assess how these aspects interact and how they impact the overall user satisfaction. This paper advances previous works by proposing and validating a flexible framework, named EViTEQ, to be applied in real testbeds to satisfy the requirements of performance assessment. EViTEQ is able to measure network interface energy consumption with high precision, while being completely technology independent and assessing the application level quality of experience. The results obtained in the testbed show the relevance of combined multi-criteria measurement approaches, leading to superior end-user satisfaction perception evaluation .

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVE To evaluate a questionnaire for obtaining owner-perceived, weighted quality-oflife assessments for dogs with spinal cord injuries. DESIGN Evaluation study. Animals-100 dogs with spinal cord injuries and 48 healthy control dogs. PROCEDURES The questionnaire was adapted from a questionnaire (the schedule for the evaluation of individual quality of life-direct weighting) used for human patients. Specifically, owners were asked to identify 5 areas or activities they believed had the most influence on their dogs' quality of life, assess their dogs' current status in each of those areas, and provide a weighting for the importance of each area. Results were used to construct a weighted quality-of-life score ranging from 0 to 100 for each dog. Owners were also asked to provide a quality-of-life score with a visual analog scale (VAS). RESULTS A good correlation was found between weighted and VAS quality-of-life scores. Dogs with spinal cord injuries had weighted quality-of-life scores that were significantly lower than scores for control dogs. Quality-of-life areas and activities provided by owners of dogs with spinal cord injuries were similar to areas and activities provided by owners of healthy control dogs and could mostly be encompassed by 5 broader domains: mobility, play or mental stimulation, health, companionship, and other. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested that the questionnaire could be used to obtain owner-perceived, weighted quality-of-life assessments for dogs with spinal cord injuries. Obtaining owner-perceived quality-of-life assessments for individual dogs should allow veterinarians to better address quality-of-life concerns and expectations of owners.