36 resultados para Prosthesis Evaluation Questionnaire
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
The objectives of this study were to develop and validate a tool for assessing pain in population-based observational studies and to develop three subscales for back/neck, upper extremity and lower extremity pain. Based on a literature review, items were extracted from validated questionnaires and reviewed by an expert panel. The initial questionnaire consisted of a pain manikin and 34 items relating to (i) intensity of pain in different body regions (7 items), (ii) pain during activities of daily living (18 items) and (iii) various pain modalities (9 items). Psychometric validation of the initial questionnaire was performed in a random sample of the German-speaking Swiss population. Analyses included tests for reliability, correlation analysis, principal components factor analysis, tests for internal consistency and validity. Overall, 16,634 of 23,763 eligible individuals participated (70%). Test-retest reliability coefficients ranged from 0.32 to 0.97, but only three coefficients were below 0.60. Subscales were constructed combining four items for each of the subscales. Item-total coefficients ranged from 0.76 to 0.86 and Cronbach's alpha were 0.75 or higher for all subscales. Correlation coefficients between subscales and three validated instruments (WOMAC, SPADI and Oswestry) ranged from 0.62 to 0.79. The final Pain Standard Evaluation Questionnaire (SEQ Pain) included 28 items and the pain manikin and accounted for the multidimensionality of pain by assessing pain location and intensity, pain during activity, triggers and time of onset of pain and frequency of pain medication. It was found to be reliable and valid for the assessment of pain in population-based observational studies.
Resumo:
BACKGROUND In Chopart-level amputations the heel often deviates into equinus and varus when, due to the lack of healthy anterior soft tissue, rebalancing tendon transfers to the talar head are not possible. Consequently, anterior and lateral wound dehiscence and ulceration may occur requiring higher-level amputation to achieve wound closure, with considerable loss of function for the patients. METHODS Twenty-four consecutive patients (15 diabetes, 6 trauma, and 3 tumor) had Chopart's amputation and simultaneous or delayed additional ankle dorsiflexion arthrodesis to allow for tension-free wound closure or soft tissue reconstruction, or to treat secondary recurrent ulcerations. Percutaneous Achilles tendon lengthening and subtalar arthrodesis were added as needed. Wound healing problems, time to fusion and full weight-bearing in the prosthesis, complications in the prosthesis, and the ambulatory status were assessed. Satisfaction and function were evaluated by the AmpuPro score and the validated Prosthesis Evaluation Questionnaire scale. RESULTS Five patients had successful soft tissue healing and fusions but died of their underlying disease 2 to 46 months after the operation. Two diabetic patients required a transtibial amputation. The other 17 patients were followed for 27 months (range, 13-63). The average age of the 4 women and 13 men was 53.9 years (range, 16-87). Postoperative complications included minor wound healing problems in 8 patients, wound breakdown requiring revision in 4, phantom pain in 3, residual equinus in 1, and adjacent scar carcinoma in 1 patient. The time to full weight-bearing in the prosthesis ranged from 6 to 24 weeks (mean 10). The mean AmpuPro score was 107 points (of 120), and the mean Prosthesis Evaluation Questionnaire scale was 147 points (of 200). No complications occurred with the prosthesis. Twelve patients lost 1 to 2 mobility classes (mean 0.9). The arthrodeses all healed within 2.5 months (range, 1.5 to 5 months). CONCLUSION Adding an ankle arthrodesis to a Chopart's amputation either immediately or in a delayed fashion to treat anterior soft tissue complications was a successful salvage in most patients at this amputation level. It enabled the patients to preserve the advantages of a full-length limb with terminal weight-bearing. LEVEL OF EVIDENCE Level IV, retrospective case series.
Resumo:
Background: Total knee replacement is the gold standard treatment for patients suffering from advanced symptomatic knee osteoarthritis. The main goals of knee prosthetics are pain reduction and restoration of knee motion. The new prostheses on the market such as the bi-cruciate stabilized Journey knee implant, promise a reconstruction of total physiological function of the knee with physiological range of motion and therefore high patient satisfaction. Purpose: The aim of this study was to analyze the patient-based Knee Injury and Osteoarthritis Outcome Score (KOOS) outcome after total knee replacement with new physiological bi-cruciate stabilized Journey knee prosthesis. Study Design: Prospective, consecutive case-series. Patients: Ninety nine patients, who received bi-cruciate stabilized Journey total knee prosthesis between January 1st 2006 and May 31st 2012, were included in the study. A single surgeon operated all patients. There were 61.1% females and the overall average age was 68 years (range 41-83 years). Left knee was replaced in 55.6%. Methods: The patients filled in KOO’s questionnaire pre- and 1 year postoperative. Range of motion (ROM) was studied preoperatively and at 1-year follow-ups. The pre- and postoperative KOOS subscores and ROM were compared using the Wilcoxon signed rank test. Results: There are significant improvements of all KOOS subscores. Ninety percent of patients have reached the minimum clinically relevant 10 points in symptoms, 94.5% in pain, 94.5% in activities of daily living, 84.9% in sport and recreation, and 90% in knee related quality of life. Postoperative, the average passive ROM was 131° (range 110-145°) and the average active ROM 122° (range 105-135°). The highest correlation coefficients ROM and the KOOS were observed for the activity and pain subscores. Very low or no correlation was seen for the sport subscore. Conclusions: Bi-cruciate stabilized knee prosthetic offers a solid outcome 1 year postoperative based on the results measured with the KOOS evaluation questionnaire. The Patients showed a generalized improvement in all domains measured in the KOOS of minimally 35, and up to over 52 points, what can be described as statistically significant. Patients described the level of functionality close to double compared to the preoperative status.
Resumo:
BACKGROUND: Breast reconstruction by latissimus dorsi myocutaneous flap in combination with a prosthesis is a widely used, well-established procedure. Short- and medium-term evaluation after this procedure is well described in the literature, but there have been no evaluations of the late course (over 10 years) published until now. METHODS: In a retrospective study, 68 patients operated on by means of this technique at the authors' institution from 1981 to 1993 resulting in a minimal follow-up of 10 years were included. Patients were invited to an interrogation, clinical examination, and photographic documentation (n = 51). Incidence of late flap or prosthesis-related complications, number of and indications for corrective procedures, and the correlation of the patients' subjective judgment and objective results in the late course have been the main interest of the authors' survey. RESULTS: The authors found that 50 percent of the patients needed a late reoperation for change or removal of the prosthesis. Seven (10 percent) of 68 patients needed a definitive removal of the implant in the late course. Assessment of the photographic documentation of the late result by four nonprofessionals showed that the objective aesthetic results of a considerable number of the authors' reconstructions were not sufficient. CONCLUSION: The procedure combines two basic techniques of reconstructive surgery, the soft-tissue restoration by a pedicled flap as the autologous reconstructive component and the volume reconstruction by prosthesis. Therefore, these patients are subject to a cumulation of the basic morbidity of the two techniques. The authors conclude that the indication for this procedure should be restricted to patients not qualifying for "pure" reconstructive techniques.
Resumo:
BACKGROUND The coping resources questionnaire for back pain (FBR) uses 12 items to measure the perceived helpfulness of different coping resources (CRs, social emotional support, practical help, knowledge, movement and relaxation, leisure and pleasure, spirituality and cognitive strategies). The aim of the study was to evaluate the instrument in a clinical patient sample assessed in a primary care setting. SAMPLE AND METHODS The study was a secondary evaluation of empirical data from a large cohort study in general practices. The 58 participating primary care practices recruited patients who reported chronic back pain in the consultation. Besides the FBR and a pain sketch, the patients completed scales measuring depression, anxiety, resilience, sociodemographic factors and pain characteristics. To allow computing of retested parameters the FBR was sent to some of the original participants again after 6 months (90% response rate). We calculated consistency and retest reliability coefficients as well as correlations between the FBR subscales and depression, anxiety and resilience scores to account for validity. By means of a cluster analysis groups with different resource profiles were formed. Results. RESULTS For the study 609 complete FBR baseline data sets could be used for statistical analysis. The internal consistency scores ranged fromα=0.58 to α=0.78 and retest reliability scores were between rTT=0.41 and rTT=0.63. Correlation with depression, fear and resilience ranged from r=-0.38 to r=0.42. The cluster analysis resulted in four groups with relatively homogenous intragroup profiles (high CRs, low spirituality, medium CRs, low CRs). The four groups differed significantly in fear and depression (the more inefficient the resources the higher the difference) as well as in resilience (the more inefficient the lower the difference). The group with low CRs also reported permanent pain with no relief. The groups did not otherwise differ. CONCLUSIONS The FBR is an economic instrument that is suitable for practical use e.g. in primary care practices to identify strengths and deficits in the CRs of chronic pain patients that can then be specified in face to face consultation. However, due to the rather low reliability, the use of subscales for profile differentiation and follow-up measurement in individual diagnoses is limited.
Resumo:
OBJECTIVE To evaluate a questionnaire for obtaining owner-perceived, weighted quality-oflife assessments for dogs with spinal cord injuries. DESIGN Evaluation study. Animals-100 dogs with spinal cord injuries and 48 healthy control dogs. PROCEDURES The questionnaire was adapted from a questionnaire (the schedule for the evaluation of individual quality of life-direct weighting) used for human patients. Specifically, owners were asked to identify 5 areas or activities they believed had the most influence on their dogs' quality of life, assess their dogs' current status in each of those areas, and provide a weighting for the importance of each area. Results were used to construct a weighted quality-of-life score ranging from 0 to 100 for each dog. Owners were also asked to provide a quality-of-life score with a visual analog scale (VAS). RESULTS A good correlation was found between weighted and VAS quality-of-life scores. Dogs with spinal cord injuries had weighted quality-of-life scores that were significantly lower than scores for control dogs. Quality-of-life areas and activities provided by owners of dogs with spinal cord injuries were similar to areas and activities provided by owners of healthy control dogs and could mostly be encompassed by 5 broader domains: mobility, play or mental stimulation, health, companionship, and other. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested that the questionnaire could be used to obtain owner-perceived, weighted quality-of-life assessments for dogs with spinal cord injuries. Obtaining owner-perceived quality-of-life assessments for individual dogs should allow veterinarians to better address quality-of-life concerns and expectations of owners.
Resumo:
As lipofilling of the female breast is becoming more popular in plastic surgery, the use of MRI to assess breast volume has been employed to control postoperative results. Therefore, we sought to evaluate the accuracy of magnetic resonance imaging (MRI)-based breast volumetry software tools by comparing the measurements of silicone implant augmented breasts with the actual implant volume specified by the manufacturer. MRI-based volume analysis was performed in eight bilaterally augmented patients (46 ± 9 years) with three different software programs (Brainlab© I plan 2.6 neuronavigation software; mass analysis, version 5.3, Medis©; and OsiriX© v.3.0.2. 32-bit). The implant volumes analysed by the BrainLab© software had a mean deviation of 2.2 ± 1.7% (r?=?0.99) relative to the implanted prosthesis. OsiriX© software analysis resulted in a mean deviation of 2.8 ± 3.0% (r?=?0.99) and the Medis© software had a mean deviation of 3.1 ± 3.0% (r?=?0.99). Overall, the volumes of all analysed breast implants correlated very well with the real implant volumes. Processing time was 10 min per breast with each system and 30 s (OsiriX©) to 5 min (BrainLab© and Medis©) per silicone implant. MRI-based volumetry is a powerful tool to calculate both native breast and silicone implant volume in situ. All software solutions performed well and the measurements were close to the actual implant sizes. The use of MRI breast volumetry may be helpful in: (1) planning reconstructive and aesthetic surgery of asymmetric breasts, (2) calculating implant size in patients with missing documentation of a previously implanted device and (3) assessing post-operative results objectively.
Resumo:
Excessive cantilever lengths of fixed implant-supported prostheses may have functional and biomechanical disadvantages. This study reports the clinical outcomes of unconventional implants placed for distal support of a fixed implant-supported prostheses. Seven extraoral implants with intraosseous lengths of 2.5 to 4.0 mm were placed in four patients. Distal cantilevers had a mean length of 29.8 mm (range, 18.6 to 39.3 mm). No bone loss or other adverse events were found. The prosthetic plan was maintained in all patients. Within the limits of the employed research design, this concept seems to be a successful option for fixed complete implant-supported prosthesis treatment.
Resumo:
Exposure to farming environments has been shown to protect substantially against asthma and atopic disease across Europe and in other parts of the world. The GABRIEL Advanced Surveys (GABRIELA) were conducted to determine factors in farming environments which are fundamental to protecting against asthma and atopic disease. The GABRIEL Advanced Surveys have a multi-phase stratified design. In a first-screening phase, a comprehensive population-based survey was conducted to assess the prevalence of exposure to farming environments and of asthma and atopic diseases (n = 103,219). The second phase was designed to ascertain detailed exposure to farming environments and to collect biomaterial and environmental samples in a stratified random sample of phase 1 participants (n = 15,255). A third phase was carried out in a further stratified sample only in Bavaria, southern Germany, aiming at in-depth respiratory disease and exposure assessment including extensive environmental sampling (n = 895). Participation rates in phase 1 were around 60% but only about half of the participating study population consented to further study modules in phase 2. We found that consenting behaviour was related to familial allergies, high parental education, wheeze, doctor diagnosed asthma and rhinoconjunctivitis, and to a lesser extent to exposure to farming environments. The association of exposure to farm environments with asthma or rhinoconjunctivitis was not biased by participation or consenting behaviour. The GABRIEL Advanced Surveys are one of the largest studies to shed light on the protective 'farm effect' on asthma and atopic disease. Bias with regard to the main study question was able to be ruled out by representativeness and high participation rates in phases 2 and 3. The GABRIEL Advanced Surveys have created extensive collections of questionnaire data, biomaterial and environmental samples promising new insights into this area of research.
Resumo:
In a retrospective cohort study undertaken in 12 European countries, 249 female narcoleptic patients with cataplexy (n = 216) and without cataplexy (n = 33) completed a self-administrated questionnaire regarding pregnancy and childbirth. The cohort was divided further into patients whose symptoms of narcolepsy started before or during pregnancy (308 pregnancies) and those in whom the first symptoms of narcolepsy appeared after delivery (106 pregnancies). Patients with narcolepsy during pregnancy were older during their first pregnancy (P < 0.001) and had a higher body mass index (BMI) prior to pregnancy (P < 0.01). Weight gain during pregnancy was higher in narcoleptic patients with cataplexy (P < 0.01). More patients with narcolepsy-cataplexy during pregnancy had impaired glucose metabolism and anaemia. Three patients experienced cataplexy during delivery. The rate of caesarean sections was higher in the narcolepsy-cataplexy group compared to the narcolepsy group (P < 0.05). The mean birth weight and gestational age of neonates were within the normal range and did not differ across groups. Neonatal care was affected adversely by symptoms of narcolepsy in 60.1% of those with narcolepsy during pregnancy. This study reports more obstetric complications in patients with narcolepsy-cataplexy during pregnancy; however, these were not severe. This group also had a higher BMI and higher incidence of impaired glucose metabolism during pregnancy. Caesarian section was conducted more frequently in narcolepsy-cataplexy patients, despite cataplexy being a rare event during delivery. Furthermore, symptoms of narcolepsy may render care of the infant more difficult.
Resumo:
OBJECTIVE: To report clinical evaluation of the clamp rod internal fixator 4.5/5.5 (CRIF 4.5/5.5) in bovine long-bone fracture repair. STUDY DESIGN: Retrospective study. ANIMALS: Cattle (n=22) with long-bone fractures. METHODS: Records for cattle with long-bone fractures repaired between 1999 and 2004 with CRIF 4.5/5.5 were reviewed. Quality of fracture repair, fracture healing, and clinical outcome were investigated by means of clinical examination, medical records, radiographs, and telephone questionnaire. RESULTS: Successful long-term outcome was achieved in 18 cattle (82%); 4 were euthanatized 2-14 days postoperatively because of fracture breakdowns. Two cattle had movement of clamps on the rod. Moderate to severe callus formation was evident in 11 cattle 6 months postoperatively. CONCLUSIONS: Movement of clamps on the rod was recognized as implant failure unique to the CRIF. This occurred in cattle with poor fracture stability because of an extensive cortical defect. The CRIF system may not be ideal to treat metacarpal/metatarsal fractures because its voluminous size makes skin closure difficult, thereby increasing the risk of postoperative infections. CLINICAL RELEVANCE: CRIF cannot be recommended for repair of complicated long-bone fractures in cattle.
Resumo:
BACKGROUND: In 2003 the Swiss federation of pharmacists organized a campaign "sleep disturbances--daytime sleepiness". The goal was to assist pharmacy clients in detecting likely causes of any sleep disturbance or daytime sleepiness through a free of charge screening, and to deliver targeted counselling. For pharmacy practice there are no screening or triage guidelines to assess the severity of sleep and wakefulness disturbances and potential causes for those disturbances. In this paper the outcome of the campaign in terms of feasibility, participation, observed response patterns, sale of over-the-counter (OTC) sleeping pills, and counselling activities is evaluated. METHODS: The Stanford sleep disorders questionnaire and the Epworth sleepiness scale served to identify patterns of symptoms suggestive of four major categories of sleep disorders. The questionnaires were posted on a web-site and the clients' data were entered online in the pharmacies. A report was automatically generated and immediately available online to the pharmacists. The pharmacists documented separately their counselling activities in a pharmacist's activity report. RESULTS: Six hundred and twenty-two (23%) of 2743 pharmacy clients had response patterns suggestive of obstructive sleep apnoea, 418 (15%) of restless-legs-syndrome, 39 (1%) of a sleep disorder potentially associated with a psychiatric condition and 79 (3%) of narcolepsy. An Epworth sleepiness score >10 points was found in 567 (21%). After screening, 2345 (86%) pharmacy clients received targeted counselling. Only 216 (8%) purchased an OTC sleeping pill and 704 (26%) were recommended to consult a physician, but of these, 446 (63%) were already under medical supervision. CONCLUSIONS: The online screening tool for sleep disorders and daytime sleepiness was successfully introduced in Swiss pharmacies. Pharmacies were able to assess the pattern of individual sleep disorders and to identify a possible cause in nearly one-third of the cases.
Resumo:
PURPOSE: In the present cohort study, overdentures with a combined root and implant support were evaluated and compared with either exclusively root- or implant-supported overdentures. Results of a 2-year follow-up period are reported, namely survival of implants, root copings, and prostheses, plus prosthetic complications, maintenance service, and patient satisfaction. MATERIALS AND METHODS: Fourteen patients were selected for the combined overdenture therapy and were compared with 2 patient groups in which either roots or implants provided overdenture support. Altogether, 14, 17, and 15 patients (in groups 1, 2, and 3, respectively) were matched with regard to age, sex, treatment time, and observation period. The mean age was around 67 years. Periodontal parameters were recorded, radiographs were taken, and all complications and failures were registered during the entire observation time. The patients answered a 9-item questionnaire by means of a visual analogue scale (VAS). RESULTS: One implant failed and 1 tooth root was removed following longitudinal root fracture. Periodontal/peri-implant parameters gave evidence of good oral hygiene for roots and implants, and slight crestal bone resorption was measured for both. Technical complications and service performed were significantly higher in the first year (P < .04) in all 3 groups and significantly higher in the tooth root group (P < .03). The results of the VAS indicated significantly lower scores for satisfaction, speaking ability, wearing comfort, and denture stability with combined or exclusive root support (P < .05 and .02, respectively). Initial costs of overdentures with combined or root support were 10% lower than for implant overdentures. CONCLUSION: The concept of combined root and implant support can be integrated into treatment planning and overdenture design for patients with a highly reduced dentition.
Resumo:
Ligament balancing in total knee arthroplasty may have an important influence on joint stability and prosthesis lifetime. In order to provide quantitative information and assistance during ligament balancing, a device that intraoperatively measures knee joint forces and moments was developed. Its performance and surgical advantages were evaluated on six cadaver specimens mounted on a knee joint loading apparatus allowing unconstrained knee motion as well as compression and varus-valgus loading. Four different experiments were performed on each specimen. (1) Knee joints were axially loaded. Comparison between applied and measured compressive forces demonstrated the accuracy and reliability of in situ measurements (1.8N). (2) Assessment of knee stability based on condyle contact forces or varus-valgus moments were compared to the current surgical method (difference of varus-valgus loads causing condyle lift-off). The force-based approach was equivalent to the surgical method while the moment-based, which is considered optimal, showed a tendency of lateral imbalance. (3) To estimate the importance of keeping the patella in its anatomical position during imbalance assessment, the effect of patellar eversion on the mediolateral distribution of tibiofemoral contact forces was measured. One fourth of the contact force induced by the patellar load was shifted to the lateral compartment. (4) The effect of minor and major medial collateral ligament releases was biomechanically quantified. On average, the medial contact force was reduced by 20% and 46%, respectively. Large variation among specimens reflected the difficulty of ligament release and the need for intraoperative force monitoring. This series of experiments thus demonstrated the device's potential to improve ligament balancing and survivorship of total knee arthroplasty.