47 resultados para Prospective organ dose estimation

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

RATIONALE AND OBJECTIVES: To evaluate the effect of a modified abdominal multislice computed tomography (CT) protocol for obese patients on image quality and radiation dose. MATERIALS AND METHODS: An adult female anthropomorphic phantom was used to simulate obese patients by adding one or two 4-cm circumferential layers of fat-equivalent material to the abdominal portion. The phantom was scanned with a subcutaneous fat thickness of 0, 4, and 8 cm using the following parameters (detector configuration/beam pitch/table feed per rotation/gantry rotation time/kV/mA): standard protocol A: 16 x 0.625 mm/1.75/17.5 mm/0.5 seconds/140/380, and modified protocol B: 16 x 1.25 mm/1.375/27.5 mm/1.0 seconds/140/380. Radiation doses to six abdominal organs and the skin, image noise values, and contrast-to-noise ratios (CNRs) were analyzed. Statistical analysis included analysis of variance, Wilcoxon rank sum, and Student's t-test (P < .05). RESULTS: Applying the modified protocol B with one or two fat rings, the image noise decreased significantly (P < .05), and simultaneously, the CNR increased significantly compared with protocol A (P < .05). Organ doses significantly increased, up to 54.7%, comparing modified protocol B with one fat ring to the routine protocol A with no fat rings (P < .05). However, no significant change in organ dose was seen for protocol B with two fat rings compared with protocol A without fat rings (range -2.1% to 8.1%) (P > .05). CONCLUSIONS: Using a modified abdominal multislice CT protocol for obese patients with 8 cm or more of subcutaneous fat, image quality can be substantially improved without a significant increase in radiation dose to the abdominal organs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Protective patient equipment for CT examinations is not routinely provided. The aim of this study was to determine whether, and if so what, specific protective equipment is beneficial during CT scans. The absorbed organ doses and the effective doses for thorax, abdomen/pelvis and brain CT investigation with and without the use of protective patient equipment have been determined and compared. All measurements were carried out on modern multislice CT scanner using an anthropomorphic phantom and thermoluminescence dosemeters. The measurements show that protective equipment reduces the dose within the scattered beam area. The highest organ dose reduction was found in organs that protrude from the trunk like the testes or the female breasts that can largely be covered by the protective equipment. The most reduction of the effective dose was found in the male abdomen/pelvis examination (0.32 mSv), followed by the brain (0.11 mSv) and the thorax (0.06 mSv). It is concluded that the use of protective equipment can reduce the applied dose to the patient.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Preclinical and clinical studies have indicated that somatostatin receptor (sst)-expressing tumors demonstrate higher uptake of radiolabeled sst antagonists than of sst agonists. In 4 consecutive patients with advanced neuroendocrine tumors, we evaluated whether treatment with (177)Lu-labeled sst antagonists is feasible. METHODS After injection of approximately 1 GBq of (177)Lu-DOTA-[Cpa-c(DCys-Aph(Hor)-DAph(Cbm)-Lys-Thr-Cys)-DTyr-NH2] ((177)Lu-DOTA-JR11) and (177)Lu-DOTATATE, 3-dimensional voxel dosimetry analysis based on SPECT/CT was performed. A higher tumor-to-organ dose ratio for (177)Lu-DOTA-JR11 than for (177)Lu-DOTATATE was the prerequisite for treatment with (177)Lu-DOTA-JR11. RESULTS Reversible minor adverse effects of (177)Lu-DOTA-JR11 were observed. (177)Lu-DOTA-JR11 showed a 1.7-10.6 times higher tumor dose than (177)Lu-DOTATATE. At the same time, the tumor-to-kidney and tumor-to-bone marrow dose ratio was 1.1-7.2 times higher. All 4 patients were treated with (177)Lu-DOTA-JR11, resulting in partial remission in 2 patients, stable disease in 1 patient, and mixed response in the other patient. CONCLUSION Treatment of neuroendocrine tumors with radiolabeled sst antagonists is clinically feasible and may have a significant impact on peptide receptor radionuclide therapy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Over the last years, the interest in proton radiotherapy is rapidly increasing. Protons provide superior physical properties compared with conventional radiotherapy using photons. These properties result in depth dose curves with a large dose peak at the end of the proton track and the finite proton range allows sparing the distally located healthy tissue. These properties offer an increased flexibility in proton radiotherapy, but also increase the demand in accurate dose estimations. To carry out accurate dose calculations, first an accurate and detailed characterization of the physical proton beam exiting the treatment head is necessary for both currently available delivery techniques: scattered and scanned proton beams. Since Monte Carlo (MC) methods follow the particle track simulating the interactions from first principles, this technique is perfectly suited to accurately model the treatment head. Nevertheless, careful validation of these MC models is necessary. While for the dose estimation pencil beam algorithms provide the advantage of fast computations, they are limited in accuracy. In contrast, MC dose calculation algorithms overcome these limitations and due to recent improvements in efficiency, these algorithms are expected to improve the accuracy of the calculated dose distributions and to be introduced in clinical routine in the near future.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Intra-organ and intra-vascular pressures can be used to estimate intra-abdominal pressure. The aim of this prospective, interventional study was to assess the effect of PEEP on the accuracy of pressure estimation at different measurement sites in a model of increased abdominal pressure.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

To evaluate the antibiotic treatment regime in patients with indwelling JJ stents, the benefits and disadvantages of a peri-interventional antibiotic prophylaxis were compared with those of a continuous low-dose antibiotic treatment in a prospective randomised trial.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVE: Computed tomography (CT) and magnetic resonance imaging (MRI) are introduced as an alternative to traditional autopsy. The purpose of this study was to investigate their accuracy in mass estimation of liver and spleen. METHODS: In 44 cases, the weights of spleen and liver were estimated based on MRI and CT data using a volume-analysis software and a postmortem tissue-specific density factor. In a blinded approach, the results were compared with the weights noted at autopsy. RESULTS: Excellent correlation between estimated and real weights (r = 0.997 for MRI, r = 0.997 for CT) was found. Putrefaction gas and venous air embolism led to an overestimation. Venous congestion and drowning caused higher estimated weights. CONCLUSION: Postmortem weights of liver and spleen can accurately be assessed by nondestructive imaging. Multislice CT overcomes the limitation of putrefaction and venous air embolism by the possibility to exclude gas. Congestion seems to be even better assessed.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Daily use of conventional electronic portal imaging devices (EPID) for organ tracking is limited due to the relatively high dose required for high quality image acquisition. We studied the use of a novel dose saving acquisition mode (RadMode) allowing to take images with one monitor unit per image in prostate cancer patients undergoing intensity-modulated radiotherapy (IMRT) and tracking of implanted fiducial gold markers. PATIENTS AND METHODS: Twenty five patients underwent implantation of three fiducial gold markers prior to the planning CT. Before each treatment of a course of 37 fractions, orthogonal localization images from the antero-posterior and from the lateral direction were acquired. Portal images of both the setup procedure and the five IMRT treatment beams were analyzed. RESULTS: On average, four localization images were needed for a correct patient setup, resulting in four monitor units extra dose per fraction. The mean extra dose delivered to the patient was thereby increased by 1.2%. The procedure was precise enough to reduce the mean displacements prior to treatment to < o =0.3 mm. CONCLUSIONS: The use of a new dose saving acquisition mode enables to perform daily EPID-based prostate tracking with a cumulative extra dose of below 1 Gy. This concept is efficiently used in IMRT-treated patients, where separation of setup beams from treatment beams is mandatory.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: In women with chronic anovulation, the choice of the FSH starting dose and the modality of subsequent dose adjustments are critical in controlling the risk of overstimulation. The aim of this prospective randomized study was to assess the efficacy and safety of a decremental FSH dose regimen applied once the leading follicle was 10-13 mm in diameter in women treated for WHO Group II anovulation according to a chronic low-dose (CLD; 75 IU FSH for 14 days with 37.5 IU increment) step-up protocol. METHODS: Two hundred and nine subfertile women were treated with recombinant human FSH (r-hFSH) (Gonal-f) for ovulation induction according to a CLD step-up regimen. When the leading follicle reached a diameter of 10-13 mm, 158 participants were randomized by means of a computer-generated list to receive either the same FSH dose required to achieve the threshold for follicular development (CLD regimen) or half of this FSH dose [sequential (SQ) regimen]. HCG was administered only if not more than three follicles >or=16 mm in diameter were present and/or serum estradiol (E(2)) values were <1200 pg/ml. The primary outcome measure was the number of follicles >or=16 mm in size at the time of hCG administration. RESULTS: Clinical characteristics and ovarian parameters at the time of randomization were similar in the two groups. Both CLD and SQ protocols achieved similar follicular growth as regards the total number of follicles and medium-sized or mature follicles (>/=16 mm: 1.5 +/- 0.9 versus 1.4 +/- 0.7, respectively). Furthermore, serum E(2) levels were equivalent in the two groups at the time of hCG administration (441 +/- 360 versus 425 +/- 480 pg/ml for CLD and SQ protocols, respectively). The rate of mono-follicular development was identical as well as the percentage of patients who ovulated and achieved pregnancy. CONCLUSIONS: The results show that the CLD step-up regimen for FSH administration is efficacious and safe for promoting mono-follicular ovulation in women with WHO Group II anovulation. This study confirms that maintaining the same FSH starting dose for 14 days before increasing the dose in step-up regimen is critical to adequately control the risk of over-response. Strict application of CLD regimen should be recommended in women with WHO Group II anovulation.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: To report acute and late toxicity in prostate cancer patients treated by dose escalated intensity-modulated radiation therapy (IMRT) and organ tracking. METHODS: From 06/2004 to 12/2005 39 men were treated by 80 Gy IMRT along with organ tracking. Median age was 69 years, risk of recurrence was low 18%, intermediate 21% and high in 61% patients. Hormone therapy (HT) was received by 74% of patients. Toxicity was scored according to the CTC scale version 3.0. Median follow-up (FU) was 29 months. RESULTS: Acute and maximal late grade 2 gastrointestinal (GI) toxicity was 3% and 8%, late grade 2 GI toxicity dropped to 0% at the end of FU. No acute or late grade 3 GI toxicity was observed. Grade 2 and 3 pre-treatment genitourinary (GU) morbidity (PGUM) was 20% and 5%. Acute and maximal late grade 2 GU toxicity was 56% and 28% and late grade 2 GU toxicity decreased to 15% of patients at the end of FU. Acute and maximal late grade 3 GU toxicity was 8% and 3%, respectively. Decreased late > or = grade 2 GU toxicity free survival was associated with higher age (P = .025), absence of HT (P = .016) and higher PGUM (P < .001). DISCUSSION: GI toxicity rates after IMRT and organ tracking are excellent, GU toxicity rates are strongly related to PGUM.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this prospective, non-randomized 6-month observational study we evaluated the efficacy of intravenous immunoglobulin (IVIg) dose increase in patients with multifocal motor neuropathy (MMN). Diagnosis according to AAEM criteria, repetitive IVIg treatment for at least one year, persistent paresis and conduction block, stable symptoms and findings for at least six months were inclusion criteria. Nine patients (7 men) were identified and approved to standardized increase of IVIg dose. Patients were monitored using clinical scores and electrophysiological studies. Dose was increased from a baseline of 0.5 g/kg per month [mean, range: 0.1-1.1], given at variable intervals [4-12 weeks] to 1.2 g/kg per month given over 3 consecutive days planned for 6 cycles. If the patients' motor function did not improve after two cycles they entered step two: Dose was increased to 2 g/kg per month given over 5 consecutive days. The increased dose was maintained for 6 months. Assessments were performed by the same investigator, not involved in the patient's management, at baseline, after 2 and after 6 months. Following dose increase, motor function significantly improved in 6 patients (p = 0.014), 2 patients entered step two, 1 patient withdrew due to absent efficacy. Higher doses of IVIg caused more side effects, however, transient and rarely severe (p = 0.014). IVIg dose increase may improve motor functions in patients with stable MMN on long-term IVIg therapy independent of baseline dose. Improvement of motor function was associated with shorter disease duration (p = 0.008), but not with degree of muscle atrophy (p = 0.483). The treatment strategy to try to find the lowest effective dose and the longest tolerated interval might lead to underdosing in the long-term in many patients.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The comparison of radiotherapy techniques regarding secondary cancer risk has yielded contradictory results possibly stemming from the many different approaches used to estimate risk. The purpose of this study was to make a comprehensive evaluation of different available risk models applied to detailed whole-body dose distributions computed by Monte Carlo for various breast radiotherapy techniques including conventional open tangents, 3D conformal wedged tangents and hybrid intensity modulated radiation therapy (IMRT). First, organ-specific linear risk models developed by the International Commission on Radiological Protection (ICRP) and the Biological Effects of Ionizing Radiation (BEIR) VII committee were applied to mean doses for remote organs only and all solid organs. Then, different general non-linear risk models were applied to the whole body dose distribution. Finally, organ-specific non-linear risk models for the lung and breast were used to assess the secondary cancer risk for these two specific organs. A total of 32 different calculated absolute risks resulted in a broad range of values (between 0.1% and 48.5%) underlying the large uncertainties in absolute risk calculation. The ratio of risk between two techniques has often been proposed as a more robust assessment of risk than the absolute risk. We found that the ratio of risk between two techniques could also vary substantially considering the different approaches to risk estimation. Sometimes the ratio of risk between two techniques would range between values smaller and larger than one, which then translates into inconsistent results on the potential higher risk of one technique compared to another. We found however that the hybrid IMRT technique resulted in a systematic reduction of risk compared to the other techniques investigated even though the magnitude of this reduction varied substantially with the different approaches investigated. Based on the epidemiological data available, a reasonable approach to risk estimation would be to use organ-specific non-linear risk models applied to the dose distributions of organs within or near the treatment fields (lungs and contralateral breast in the case of breast radiotherapy) as the majority of radiation-induced secondary cancers are found in the beam-bordering regions.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND The optimal management of high-risk prostate cancer remains uncertain. In this study we assessed the safety and efficacy of a novel multimodal treatment paradigm for high-risk prostate cancer. METHODS This was a prospective phase II trial including 35 patients with newly diagnosed high-risk localized or locally advanced prostate cancer treated with high-dose intensity-modulated radiation therapy preceded or not by radical prostatectomy, concurrent intensified-dose docetaxel-based chemotherapy and long-term androgen deprivation therapy. Primary endpoint was acute and late toxicity evaluated with the Common Terminology Criteria for Adverse Events version 3.0. Secondary endpoint was biochemical and clinical recurrence-free survival explored with the Kaplan-Meier method. RESULTS Acute gastro-intestinal and genito-urinary toxicity was grade 2 in 23% and 20% of patients, and grade 3 in 9% and 3% of patients, respectively. Acute blood/bone marrow toxicity was grade 2 in 20% of patients. No acute grade ≥ 4 toxicity was observed. Late gastro-intestinal and genito-urinary toxicity was grade 2 in 9% of patients each. No late grade ≥ 3 toxicity was observed. Median follow-up was 63 months (interquartile range 31-79). Actuarial 5-year biochemical and clinical recurrence-free survival rate was 55% (95% confidence interval, 35-75%) and 70% (95% confidence interval, 52-88%), respectively. CONCLUSIONS In our phase II trial testing a novel multimodal treatment paradigm for high-risk prostate cancer, toxicity was acceptably low and mid-term oncological outcome was good. This treatment paradigm, thus, may warrant further evaluation in phase III randomized trials.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVES To find a threshold body weight (BW) below 100 kg above which computed tomography pulmonary angiography (CTPA) using reduced radiation and a reduced contrast material (CM) dose provides significantly impaired quality and diagnostic confidence compared with standard-dose CTPA. METHODS In this prospectively randomised study of 501 patients with suspected pulmonary embolism and BW <100 kg, 246 were allocated into the low-dose group (80 kVp, 75 ml CM) and 255 into the normal-dose group (100 kVp, 100 ml CM). Contrast-to-noise ratio (CNR) in the pulmonary trunk was calculated. Two blinded chest radiologists independently evaluated subjective image quality and diagnostic confidence. Data were compared between the normal-dose and low-dose groups in five BW subgroups. RESULTS Vessel attenuation did not differ between the normal-dose and low-dose groups within each BW subgroup (P = 1.0). The CNR was higher with the normal-dose compared with the low-dose protocol (P < 0.006) in all BW subgroups except for the 90-99 kg subgroup (P = 0.812). Subjective image quality and diagnostic confidence did not differ between CT protocols in all subgroups (P between 0.960 and 1.0). CONCLUSIONS Subjective image quality and diagnostic confidence with 80 kVp CTPA is not different from normal-dose protocol in any BW group up to 100 kg. KEY POINTS • 80 kVp CTPA is safe in patients weighing <100 kg • Reduced radiation and iodine dose still provide high vessel attenuation • Image quality and diagnostic confidence with low-dose CTPA is good • Diagnostic confidence does not deteriorate in obese patients weighing <100 kg.