54 resultados para Planning and control

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

CONCLUSION: Our self-developed planning and navigation system has proven its capacity for accurate surgery on the anterior and lateral skull base. With the incorporation of augmented reality, image-guided surgery will evolve into 'information-guided surgery'. OBJECTIVE: Microscopic or endoscopic skull base surgery is technically demanding and its outcome has a great impact on a patient's quality of life. The goal of the project was aimed at developing and evaluating enabling navigation surgery tools for simulation, planning, training, education, and performance. This clinically applied technological research was complemented by a series of patients (n=406) who were treated by anterior and lateral skull base procedures between 1997 and 2006. MATERIALS AND METHODS: Optical tracking technology was used for positional sensing of instruments. A newly designed dynamic reference base with specific registration techniques using fine needle pointer or ultrasound enables the surgeon to work with a target error of < 1 mm. An automatic registration assessment method, which provides the user with a color-coded fused representation of CT and MR images, indicates to the surgeon the location and extent of registration (in)accuracy. Integration of a small tracker camera mounted directly on the microscope permits an advantageous ergonomic way of working in the operating room. Additionally, guidance information (augmented reality) from multimodal datasets (CT, MRI, angiography) can be overlaid directly onto the surgical microscope view. The virtual simulator as a training tool in endonasal and otological skull base surgery provides an understanding of the anatomy as well as preoperative practice using real patient data. RESULTS: Using our navigation system, no major complications occurred in spite of the fact that the series included difficult skull base procedures. An improved quality in the surgical outcome was identified compared with our control group without navigation and compared with the literature. The surgical time consumption was reduced and more minimally invasive approaches were possible. According to the participants' questionnaires, the educational effect of the virtual simulator in our residency program received a high ranking.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new system for computer-aided corrective surgery of the jaws has been developed and introduced clinically. It combines three-dimensional (3-D) surgical planning with conventional dental occlusion planning. The developed software allows simulating the surgical correction on virtual 3-D models of the facial skeleton generated from computed tomography (CT) scans. Surgery planning and simulation include dynamic cephalometry, semi-automatic mirroring, interactive cutting of bone and segment repositioning. By coupling the software with a tracking system and with the help of a special registration procedure, we are able to acquire dental occlusion plans from plaster model mounts. Upon completion of the surgical plan, the setup is used to manufacture positioning splints for intraoperative guidance. The system provides further intraoperative assistance with the help of a display showing jaw positions and 3-D positioning guides updated in real time during the surgical procedure. The proposed approach offers the advantages of 3-D visualization and tracking technology without sacrificing long-proven cast-based techniques for dental occlusion evaluation. The system has been applied on one patient. Throughout this procedure, we have experienced improved assessment of pathology, increased precision, and augmented control.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present study evaluated personal resource-oriented interventions supporting the career development of young academics, working at German universities within the STEM fields. The study sought to foster subjective career success by improving networking behavior, career planning, and career optimism. The study involved a quasi-experimental pre-post intervention with two intervention and two control groups (N = 81 research associates). Participants of the first intervention group received networking training; participants of the second intervention group received the same networking training plus individual career coaching. Participants of both intervention groups were female. Participants of the control groups (i.e., male vs. female group) did not participate in any intervention. As expected, path analyses, based on mean differences frompre-test to post-test, revealed an increase in career planning and career optimism within the networking plus career coaching intervention group, that was indirectly positively related to changes in subjective career success. Contrary to our expectations, the networking group training alone and in combination with the career coaching showed no effectiveness in fostering networking behavior. Results are discussed in the context of career counseling and intervention effectiveness studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE The pararectus approach has been validated for managing acetabular fractures. We hypothesised it might be an alternative approach for performing periacetabular osteotomy (PAO). METHODS Using four cadaver specimens, we randomly performed PAO through either the pararectus or a modified Smith-Petersen (SP) approach. We assessed technical feasibility and safety. Furthermore, we controlled fragment mobility using a surgical navigation system and compared mobility between approaches. The navigation system's accuracy was tested by cross-examination with validated preoperative planning software. RESULTS The pararectus approach is technically feasible, allowing for adequate exposure, safe osteotomies and excellent control of structures at risk. Fragment mobility is equal to that achieved through the SP approach. Validation of these measurements yielded a mean difference of less <1 mm without statistical significance. CONCLUSION Experimental data suggests the pararectus approach might be an alternative approach for performing PAO. Clinical validation is necessary to confirm these promising preliminary results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

There is a demand for technologies able to assess the perfusion of surgical flaps quantitatively and reliably to avoid ischemic complications. The aim of this study is to test a new high-speed high-definition laser Doppler imaging (LDI) system (FluxEXPLORER, Microvascular Imaging, Lausanne, Switzerland) in terms of preoperative mapping of the vascular supply (perforator vessels) and postoperative flow monitoring. The FluxEXPLORER performs perfusion mapping of an area 9 x 9 cm with a resolution of 256 x 256 pixels within 6 s in high-definition imaging mode. The sensitivity and predictability to localize perforators is expressed by the coincidence of preoperatively assessed LDI high flow spots with intraoperatively verified perforators in nine patients. 18 free flaps are monitored before, during, and after total ischemia. 63% of all verified perforators correspond to a high flow spot, and 38% of all high flow spots correspond to a verified perforator (positive predictive value). All perfused flaps reveal a value of above 221 perfusion units (PUs), and all values obtained in the ischemic flaps are beneath 187 PU. In summary, we conclude that the present LDI system can serve as a reliable, fast, and easy-to-handle tool to detect ischemia in free flaps, whereas perforator vessels cannot be detected appropriately.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

microRNAs (miRNAs) are small non-coding RNAs that are frequently involved in carcinogenesis. Although many miRNAs form part of integrated networks, little information is available how they interact with each other to control cellular processes. miR-34a and miR-15a/16 are functionally related; they share common targets and control similar processes including G1-S cell cycle progression and apoptosis. The aim of this study was to investigate the combined action of miR-34a and miR-15a/16 in non-small cell lung cancer (NSCLC) cells.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Since 1987, when bovine spongiform encephalopathy (BSE) emerged as a novel disease in cattle, enormous efforts were undertaken to monitor and control the disease in ruminants worldwide. The driving force was its high economic impact, which resulted from trade restrictions and the loss of consumer confidence in beef products, the latter because BSE turned out to be a fatal zoonosis, causing variant Creutzfeldt-Jakob disease in human beings. The ban on meat and bone meal in livestock feed and the removal of specified risk materials from the food chain were the main measures to successfully prevent infection in cattle and to protect human beings from BSE exposure. However, although BSE is now under control, previously unknown, so-called atypical transmissible spongiform encephalopathies (TSEs) in cattle and small ruminants have been identified by enhanced disease surveillance. This report briefly reviews and summarizes the current level of knowledge on the spectrum of TSEs in cattle and small ruminants and addresses the question of the extent to which such atypical TSEs have an effect on disease surveillance and control strategies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: Surgical site infections (SSI) are the most common hospital-acquired infections among surgical patients, with significant impact on patient morbidity and health care costs. The Basel SSI Cohort Study was performed to evaluate risk factors and validate current preventive measures for SSI. The objective of the present article was to review the main results of this study and its implications for clinical practice and future research. SUMMARY OF METHODS OF THE BASEL SSI COHORT STUDY: The prospective observational cohort study included 6,283 consecutive general surgery procedures closely monitored for evidence of SSI up to 1 year after surgery. The dataset was analysed for the influence of various potential SSI risk factors, including timing of surgical antimicrobial prophylaxis (SAP), glove perforation, anaemia, transfusion and tutorial assistance, using multiple logistic regression analyses. In addition, post hoc analyses were performed to assess the economic burden of SSI, the efficiency of the clinical SSI surveillance system, and the spectrum of SSI-causing pathogens. REVIEW OF MAIN RESULTS OF THE BASEL SSI COHORT STUDY: The overall SSI rate was 4.7% (293/6,283). While SAP was administered in most patients between 44 and 0 minutes before surgical incision, the lowest risk of SSI was recorded when the antibiotics were administered between 74 and 30 minutes before surgery. Glove perforation in the absence of SAP increased the risk of SSI (OR 2.0; CI 1.4-2.8; p <0.001). No significant association was found for anaemia, transfusion and tutorial assistance with the risk of SSI. The mean additional hospital cost in the event of SSI was CHF 19,638 (95% CI, 8,492-30,784). The surgical staff documented only 49% of in-hospital SSI; the infection control team registered the remaining 51%. Staphylococcus aureus was the most common SSI-causing pathogen (29% of all SSI with documented microbiology). No case of an antimicrobial-resistant pathogen was identified in this series. CONCLUSIONS: The Basel SSI Cohort Study suggested that SAP should be administered between 74 and 30 minutes before surgery. Due to the observational nature of these data, corroboration is planned in a randomized controlled trial, which is supported by the Swiss National Science Foundation. Routine change of gloves or double gloving is recommended in the absence of SAP. Anaemia, transfusion and tutorial assistance do not increase the risk of SSI. The substantial economic burden of in-hospital SSI has been confirmed. SSI surveillance by the surgical staff detected only half of all in-hospital SSI, which prompted the introduction of an electronic SSI surveillance system at the University Hospital of Basel and the Cantonal Hospital of Aarau. Due to the absence of multiresistant SSI-causing pathogens, the continuous use of single-shot single-drug SAP with cefuroxime (plus metronidazole in colorectal surgery) has been validated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this study, we show the use of three-dimensional printing models for preoperative planning of transcatheter valve replacement in a patient with an extreme porcelain aorta. A 70-year-old man with severe aortic stenosis and a porcelain aorta was referred to our center for transcatheter aortic valve replacement. Unfortunately, the patient died after the procedure because of a potential ischemic event. Therefore, we decided to fabricate three-dimensional models to evaluate the potential effects of these constructs for previous surgical planning and simulation of the transcatheter valve replacement.