205 resultados para Pediatric hip radiography
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
OBJECTIVE Proximal femoral osteotomy with stable fixation and sufficient correction. Low complication rates due to exact preoperative planning. INDICATIONS Congenital or traumatic femoral neck pseudarthrosis. Coxa vara. CONTRAINDICATIONS None. In severe deformities, a single femoral osteotomy may not solve the problem; thus, additional correction, e.g., a pelvic osteotomy, is required. SURGICAL TECHNIQUE Correct planning of the correction angle. Lateral approach. Subperiosteal detachment of vastus lateralis muscle. Place guide wire on the femoral neck to judge anteversion. Insert positioning wire 5 mm distal to trochanteric physis. Insert 2.8 mm Kirschner wire in the femoral neck. Osteotomy of the femur after marking the rotation by Kirschner wires or oscillating saw. Slide LC plate over Kirschner wires. Replace Kirschner wires with screws. Reduction of the femoral shaft to the plate with bone forceps. Definitive fixation of the plate to the femoral shaft by cortex or locking screws. Readaptation of vastus lateralis muscle over the plate. POSTOPERATIVE MANAGEMENT Partial weightbearing for 4-6 weeks depending on the age of the patient without any external fixation (e. g. cast) is possible. RESULTS Recent studies support the authors' findings of sufficient correction and stable fixation after proximal femoral osteotomy with the LCP pediatric hip plate. Low complication rates and stable fixation.
Resumo:
The effect of copper (Cu) filtration on image quality and dose in different digital X-ray systems was investigated. Two computed radiography systems and one digital radiography detector were used. Three different polymethylmethacrylate blocks simulated the pediatric body. The effect of Cu filters of 0.1, 0.2, and 0.3 mm thickness on the entrance surface dose (ESD) and the corresponding effective doses (EDs) were measured at tube voltages of 60, 66, and 73 kV. Image quality was evaluated in a contrast-detail phantom with an automated analyzer software. Cu filters of 0.1, 0.2, and 0.3 mm thickness decreased the ESD by 25-32%, 32-39%, and 40-44%, respectively, the ranges depending on the respective tube voltages. There was no consistent decline in image quality due to increasing Cu filtration. The estimated ED of anterior-posterior (AP) chest projections was reduced by up to 23%. No relevant reduction in the ED was noted in AP radiographs of the abdomen and pelvis or in posterior-anterior radiographs of the chest. Cu filtration reduces the ESD, but generally does not reduce the effective dose. Cu filters can help protect radiosensitive superficial organs, such as the mammary glands in AP chest projections.
Resumo:
OBJECTIVE: The purpose of this study was to review the diagnosis on MRI and radiography of 24 renal transplant recipients with hip pain suspicious for avascular necrosis and to investigate whether there is an association between kidney transplant patients with end-stage renal disease and symptomatic gluteus minimus and medius tendon abnormality. CONCLUSION: Symptomatic gluteus minimus and medius tendon lesions and abnormalities can occur in renal allograft recipients. The MRI findings of this entity allow an alternative diagnosis in this patient population.
An examination chair to measure internal rotation of the hip in routine settings: a validation study
Resumo:
OBJECTIVE: To determine the performance of a newly developed examination chair as compared with the clinical standard of assessing internal rotation (IR) of the flexed hip with a goniometer.
METHODS: The examination chair allowed measurement of IR in a sitting position simultaneously in both hips, with hips and knees flexed 90 degrees, lower legs hanging unsupported and a standardized load of 5 kg applied to both ankles using a bilateral pulley system. Clinical assessment of IR was performed in supine position with hips and knees flexed 90 degrees using a goniometer. Within the framework of a population-based inception cohort study, we calculated inter-observer agreement in two samples of 84 and 64 consecutive, unselected young asymptomatic males using intra-class correlation coefficients (ICC) and determined the correlation between IR assessed with examination chair and clinical assessment.
RESULTS: Inter-observer agreement was excellent for the examination chair (ICC right hip, 0.92, 95% confidence interval [CI] 0.89-0.95; ICC left hip, 0.90, 95% CI 0.86-0.94), and considerably higher than that seen with clinical assessment (ICC right hip, 0.65, 95% CI 0.49-0.77; ICC left hip, 0.69, 95% CI 0.54-0.80, P for difference in ICC between examination chair and clinical assessment
Resumo:
BACKGROUND: Decreased bone mineral density has been reported in children with inflammatory bowel disease (IBD). We used peripheral quantitative computed tomography (pQCT) to assess bone mineralization, geometry, and muscle cross-sectional area (CSA) in pediatric IBD. METHODS: In a cross-sectional study, pQCT of the forearm was applied in 143 IBD patients (mean age 13.9 +/- 3.5 years); 29% were newly diagnosed, 98 had Crohn's disease, and 45 had ulcerative colitis. Auxological data, cumulative glucocorticoid dose, disease activity indices, laboratory markers for inflammation, and bone metabolism were related to the results of pQCT. RESULTS: Patients were compromised in height (-0.82 +/- 1.1 SD), weight (-0.77 +/- 1.0 SD), muscle mass (-1.12 +/- 1.0 SD), and total bone cross-sectional area (-0.79 +/- 1.0 SD) compared to age- and sex-matched healthy controls (z-scores). In newly diagnosed patients, the ratio of bone mineral mass per muscle CSA was higher than in those with longer disease duration (1.00 versus 0.30, P = 0.007). Serum albumin level and disease activity correlated with muscle mass, accounting for 41.0% of variability in muscle mass (P < 0.01). The trabecular bone mineral density z-score was on average at the lower normal level (-0.40 +/- 1.3 SD, P < 0.05). CONCLUSIONS: Reduced bone geometry was explained only in part by reduced height. Bone disease in children with IBD seems to be secondary to muscle wasting, which is already present at diagnosis. With longer disease duration, bone adapts to the lower muscle CSA. Serum albumin concentration is a good marker for muscle wasting and abnormal bone development.
Resumo:
BACKGROUND: Inflammatory lung diseases are a major morbidity factor in children. Therefore, novel strategies for early detection of inflammatory lung diseases are of high interest. Bacterial lipopolysaccharide (LPS) is recognized via Toll-like receptors and CD14. CD14 exists as a soluble (sCD14) and membrane-associated (mCD14) protein, present on the surface of leukocytes. Previous studies suggest sCD14 as potential marker for inflammatory diseases, but their potential role in pediatric lung diseases remained elusive. Therefore, we examined the expression, regulation and significance of sCD14 and mCD14 in pediatric lung diseases. METHODS: sCD14 levels were quantified in serum and bronchoalveolar lavage fluid (BALF) of children with infective (pneumonia, cystic fibrosis, CF) and non-infective (asthma) inflammatory lung diseases and healthy control subjects by ELISA. Membrane CD14 expression levels on monocytes in peripheral blood and on alveolar macrophages in BALF were quantified by flow cytometry. In vitro studies were performed to investigate which factors regulate sCD14 release and mCD14 expression. RESULTS: sCD14 serum levels were specifically increased in serum of children with pneumonia compared to CF, asthma and control subjects. In vitro, CpG induced the release of sCD14 levels in a protease-independent manner, whereas LPS-mediated mCD14 shedding was prevented by serine protease inhibition. CONCLUSIONS: This study demonstrates for the first time the expression, regulation and clinical significance of soluble and membrane CD14 receptors in pediatric inflammatory lung diseases and suggests sCD14 as potential marker for pneumonia in children.
Resumo:
To assess the sensitivity and image quality of chest radiography (CXR) with or without dual-energy subtracted (ES) bone images in the detection of rib fractures.
Resumo:
The objective of our study was to compare the performance of low-dose linear slit digital radiography (DR) with computed radiography (CR) for the detection of trauma sequelae in the chest including rib fractures, pneumothorax, and lung contusion.
Resumo:
Purpose: In a prospective study, we assessed if a diagnosis of osteoporosis and periodontitis could predict hip and hand fractures in older persons. Materials and methods: Bone density was assessed by a Densitometer. Periodontitis was defined by evidence of alveolar bone loss. Results: 788 Caucasians (52.4% women, overall mean age: 76 years, S.D. +/- 9.0, range: 62 to 96) were enrolled and 7.4% had a hip/hand fracture in 3 years. Calcaneus PIXI T-values < - 1.6 identified osteoporosis in 28.2% of the older persons predicting a hip/hand fracture with an odds ratio of 3.3:1 (95% CI: 1.9, 5.7, p < 0.001). Older persons with osteoporosis had more severe periodontitis (p < 0.01). Periodontitis defined by >= 30% of sites with >= 5 mm distance between the cemento-enamel junction (CEJ) and bone level (ABL) was found in 18.7% of the older persons predicting a hip/hand fracture with an odds ratio of 1.8:1 (95% CI: 1.0, 3.3, p < 0.05). Adjusted for age, the odds ratio of a hip/hand fracture in older persons with osteoporosis (PIXI T-value <-2.5) and periodontitis was 12.2:1 (95% CI: 3.5, 42.3, p < 0.001). Conclusions: Older persons with osteoporosis and periodontitis have an increased risk for hip/hand fractures