19 resultados para Peak nasal inspiratory flow

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of the present study was to assess the validity of barometric whole-body plethysmography (BWBP), to establish reference values, and to standardise a bronchoprovocative test to investigate airway responsiveness using BWBP in healthy dogs. BWBP measurements were obtained from six healthy beagle dogs using different protocols: (1) during three consecutive periods (3.5min each) in two morning and two evening sessions; (2) before and after administration of two protocols of sedation; (3) before and after nebulisation of saline and increasing concentrations of carbachol and histamine both in conscious dogs and in dogs under both protocols of sedation. Enhanced pause (PENH) was used as index of bronchoconstriction. Basal BWBP measurements were also obtained in 22 healthy dogs of different breeds, age and weight. No significant influence of either time spent in the chamber or daytime was found for most respiratory variables but a significant dog effect was detected for most variables. A significant body weight effect was found on tidal volume and peak flow values (P<0.05). Response to carbachol was not reproducible and always associated with side effects. Nebulisation of histamine induced a significant increase in respiratory rate, peak expiratory flow, peak expiratory flow/peak inspiratory flow ratio and PENH (P<0.05). The response was reproduced in each dog at different concentrations of histamine. Sedation with acepromazine+buprenorphine had little influence on basal measurements and did not change the results of histamine challenge. It was concluded that BWBP is a safe, non invasive and reliable technique of investigation of lung function in dogs which provides new opportunities to characterise respiratory status, to evaluate airway hyperresponsiveness and to assess therapeutic interventions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Incontinentia lactis is a possible predisposing factor for an elevated level of intramammary infection. The goal of the present study was to investigate possible causes of incontinentia lactis in dairy cows. Two farms that differed in breed composition, but that had similar average milk yields were studied: herd A, 28 kg/d, 31 Red Holstein cows; and herd B, 26 kg/d, 16 Brown Swiss cows. Herd A was classified into 2 groups: incontinentia lactis (ILA group) and control, whereas herd B was exclusively a control herd. Milk samples that represented foremilk and the main milk fraction were collected during 4 milking sessions. In addition, milk leakage samples from the ILA group were collected at different time intervals from 0 to 5 h before milking. Measurements of the teat, milk flow, fractions of cisternal and alveolar milk, intramammary pressure, and blood oxytocin pattern also were obtained. The ILA cows did not have differences in fat content between milk leakage and cisternal milk fraction. Milk fat content, however, increased during milking in response to continuous milk ejection (1.95, 1.99, and 4.61% for milk leakage, cisternal, and main milk samples, respectively). Teat canals were 9% shorter in the ILA cows, which showed greater milk yield, peak, and average flow rates. Quarter cisternal milk yield of ILA cows tended to be greater (0.50 vs. 0.23 and 0.28 kg for ILA and controls from herds A and B, respectively), whereas percentages of cistern milk and alveolar milk did not differ from controls. The greater pressure in the ILA group, both before and after manual udder stimulation (ILA: 4.0 and 6.4 kPa; control: 2.0 and 5.0 kPa, respectively), could be an important cause for the leakage. Nevertheless, the increase in IMP that occurred after udder preparation affirms that milk ejection occurred in response to the tactile teat stimulation, but not before the onset of leakage. Blood oxytocin concentration in ILA cows was low until the start of udder preparation and increased in response to the milking stimulus (reaffirming the hypothesis that milk leakage occurred in the absence of milk ejection). In conclusion, milk losses by leakage are likely due to the large amount of cisternal milk, which creates pressure and causes leakage, in the absence of milk ejection.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Compared with term-born infants, preterm infants have increased respiratory morbidity in the first year of life. We investigated whether lung function tests performed near term predict subsequent respiratory morbidity during the first year of life and compared this to standard clinical parameters in preterms.The prospective birth cohort included randomly selected preterm infants with and without bronchopulmonary dysplasia. Lung function (tidal breathing and multiple-breath washout) was measured at 44 weeks post-menstrual age during natural sleep. We assessed respiratory morbidity (wheeze, hospitalisation, inhalation and home oxygen therapy) after 1 year using a standardised questionnaire. We first assessed the association between lung function and subsequent respiratory morbidity. Secondly, we compared the predictive power of standard clinical predictors with and without lung function data.In 166 preterm infants, tidal volume, time to peak tidal expiratory flow/expiratory time ratio and respiratory rate were significantly associated with subsequent wheeze. In comparison with standard clinical predictors, lung function did not improve the prediction of later respiratory morbidity in an individual child.Although associated with later wheeze, noninvasive infant lung function shows large physiological variability and does not add to clinically relevant risk prediction for subsequent respiratory morbidity in an individual preterm.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION Monitoring breathing pattern is especially relevant in infants with lung disease. Recently, a vest-based inductive plethysmograph system (FloRight®) has been developed for tidal breathing measurement in infants. We investigated the accuracy of tidal breathing flow volume loop (TBFVL) measurements in healthy term-born infants and infants with lung disease by the vest-based system in comparison to an ultrasonic flowmeter (USFM) with a face mask. We also investigated whether the system discriminates between healthy infants and those with lung disease. METHODS Floright® measures changes in thoracoabdominal volume during tidal breathing through magnetic field changes generated by current-carrying conductor coils in an elastic vest. Simultaneous TBFVL measurements by the vest-based system and the USFM were performed at 44 weeks corrected postmenstrual age during quiet unsedated sleep. TBFVL parameters derived by both techniques and within both groups were compared. RESULTS We included 19 healthy infants and 18 infants with lung disease. Tidal volume per body weight derived by the vest-based system was significantly lower with a mean difference (95% CI) of -1.33 ml/kg (-1.73; -0.92), P < 0.001. Respiratory rate and ratio of time to peak tidal expiratory flow over total expiratory time (tPTEF/tE) did not differ between the two techniques. Both systems were able to discriminate between healthy infants and those with lung disease using tPTEF/tE. CONCLUSION FloRight® accurately measures time indices and may discriminate between healthy infants and those with lung disease, but demonstrates differences in tidal volume measurements. It may be better suited to monitor breathing pattern than for TBFVL measurements.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background A recent method determines regional gas flow of the lung by electrical impedance tomography (EIT). The aim of this study is to show the applicability of this method in a porcine model of mechanical ventilation in healthy and diseased lungs. Our primary hypothesis is that global gas flow measured by EIT can be correlated with spirometry. Our secondary hypothesis is that regional analysis of respiratory gas flow delivers physiologically meaningful results. Methods In two sets of experiments n = 7 healthy pigs and n = 6 pigs before and after induction of lavage lung injury were investigated. EIT of the lung and spirometry were registered synchronously during ongoing mechanical ventilation. In-vivo aeration of the lung was analysed in four regions-of-interest (ROI) by EIT: 1) global, 2) ventral (non-dependent), 3) middle and 4) dorsal (dependent) ROI. Respiratory gas flow was calculated by the first derivative of the regional aeration curve. Four phases of the respiratory cycle were discriminated. They delivered peak and late inspiratory and expiratory gas flow (PIF, LIF, PEF, LEF) characterizing early or late inspiration or expiration. Results Linear regression analysis of EIT and spirometry in healthy pigs revealed a very good correlation measuring peak flow and a good correlation detecting late flow. PIFEIT = 0.702 · PIFspiro + 117.4, r2 = 0.809; PEFEIT = 0.690 · PEFspiro-124.2, r2 = 0.760; LIFEIT = 0.909 · LIFspiro + 27.32, r2 = 0.572 and LEFEIT = 0.858 · LEFspiro-10.94, r2 = 0.647. EIT derived absolute gas flow was generally smaller than data from spirometry. Regional gas flow was distributed heterogeneously during different phases of the respiratory cycle. But, the regional distribution of gas flow stayed stable during different ventilator settings. Moderate lung injury changed the regional pattern of gas flow. Conclusions We conclude that the presented method is able to determine global respiratory gas flow of the lung in different phases of the respiratory cycle. Additionally, it delivers meaningful insight into regional pulmonary characteristics, i.e. the regional ability of the lung to take up and to release air.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Nasal spray from lemon and quince (LQNS) is used to treat hay fever symptoms and has been shown to inhibit histamine release from mast cells in vitro. Forty-three patients with grass pollen allergy (GPA) were randomized to be treated either with placebo or LQNS for one week, respectively, in a cross-over study. At baseline and after the respective treatments patients were provoked with grass pollen allergen. Outcome parameters were nasal flow measured with rhinomanometry (primary), a nasal symptom score, histamine in the nasal mucus and tolerability. In the per protocol population absolute inspiratory nasal flow 10 and 20 min after provocation was higher with LQNS compared to placebo (-37 ± 87 mL/s; p = 0.027 and -44 ± 85 mL/s; p = 0.022). The nasal symptom score showed a trend (3.3 ± 1.8 in the placebo and 2.8 ± 1.5 in the LQNS group; p = 0.070) in favor of LQNS; the histamine concentration was not significantly different between the groups. Tolerability of both, LQNS and placebo, was rated as very good. LQNS seems to have an anti-allergic effect in patients with GPA. Copyright © 2016 John Wiley & Sons, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Infants with chronic lung disease (CLD) have a capacity to maintain functional lung volume despite alterations to their lung mechanics. We hypothesize that they achieve this by altering breathing patterns and dynamic elevation of lung volume, leading to differences in the relationship between respiratory muscle activity, flow and lung volume. Lung function and transcutaneous electromyography of the respiratory muscles (rEMG) were measured in 20 infants with CLD and in 39 healthy age-matched controls during quiet sleep. We compared coefficient of variations (CVs) of rEMG and the temporal relationship of rEMG variables, to flow and lung volume [functional residual capacity (FRC)] between these groups. The time between the start of inspiratory muscle activity and the resulting flow (tria)--in relation to respiratory cycle time--was significantly longer in infants with CLD. Although FRC had similar associations with tria and postinspiratory activity (corrected for respiratory cycle time), the CV of the diaphragmatic rEMG was lower in CLD infants (22.6 versus 31.0%, p = 0.030). The temporal relationship of rEMG to flow and FRC and the loss of adaptive variability provide additional information on coping mechanisms in infants with CLD. This technique could be used for noninvasive bedside monitoring of CLD.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To study the effects of a milking system that partially compensates for milk flow-dependent vacuum loss compared with a standard (high-line) milking unit in a tie-stall barn, milk flow and vacuum patterns were recorded in 10 cows during machine milking with 2 milking systems in a crossover design for 7 d each. Before and after each treatment period postmilking teat condition was recorded by ultrasound cross-sectioning. Additionally, 2 methods to measure teat tissue condition were compared: longitudinal teat ultrasound cross-sectioning and teat tissue density measurements with the spring-loaded caliper (cutimeter method). The partial compensation of milk flow-dependent vacuum loss caused an elevation of the peak flow rate (4.74+/-0.08 vs. 4.29+/-0.07 kg/min) and a shorter duration of plateau (1.57+/-0.06 vs. 1.96+/-0.07 min) compared with the standard milking system. Total milk yield, duration of incline and decline of milk flow, average milk flow, time until peak flow rate, main milking time, and total milking time did not differ between treatments (overall means: 13.75+/-0.17 kg; 0.65+/-0.01 min; 2.88+/-0.09 min; 2.82+/-0.05 kg/min; 1.65+/-0.03 min; 5.23+/-0.09 min, and 5.30+/-0.10 min, respectively). The vacuum drop in the short milk tube during periods of high milk flow was less in the compensating vacuum than in the standard milking system (11+/-1.1 vs. 15+/-0.7 kPa). Teat measures as determined by ultrasound remained unchanged over the entire experimental period with both milking systems. Postmilking teat tissue measures including their recovery within 20 min after the end of milking show a correlation (0.85 and 0.71, respectively) between the methods used (ultrasound and cutimeter method). In conclusion, a more constant vacuum at the teat tip (within the short milk tube) during periods of high milk flow affected milk flow patterns, mainly increasing peak flow rate. However, the reduced vacuum loss did not increase the overall speed of milking. In addition, effects of higher vacuum stability on teat condition and udder health were not obvious.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Vascular surgical training currently has to cope with various challenges, including restrictions on work hours, significant reduction of open surgical training cases in many countries, an increasing diversity of open and endovascular procedures, and distinct expectations by trainees. Even more important, patients and the public no longer accept a "learning by doing" training philosophy that leaves the learning curve on the patient's side. The Vascular International (VI) Foundation and School aims to overcome these obstacles by training conventional vascular and endovascular techniques before they are applied on patients. To achieve largely realistic training conditions, lifelike pulsatile models with exchangeable synthetic arterial inlays were created to practice carotid endarterectomy and patch plasty, open abdominal aortic aneurysm surgery, and peripheral bypass surgery, as well as for endovascular procedures, including endovascular aneurysm repair, thoracic endovascular aortic repair, peripheral balloon dilatation, and stenting. All models are equipped with a small pressure pump inside to create pulsatile flow conditions with variable peak pressures of ~90 mm Hg. The VI course schedule consists of a series of 2-hour modules teaching different open or endovascular procedures step-by-step in a standardized fashion. Trainees practice in pairs with continuous supervision and intensive advice provided by highly experienced vascular surgical trainers (trainer-to-trainee ratio is 1:4). Several evaluations of these courses show that tutor-assisted training on lifelike models in an educational-centered and motivated environment is associated with a significant increase of general and specific vascular surgical technical competence within a short period of time. Future studies should evaluate whether these benefits positively influence the future learning curve of vascular surgical trainees and clarify to what extent sophisticated models are useful to assess the level of technical skills of vascular surgical residents at national or international board examinations. This article gives an overview of our experiences of >20 years of practical training of beginners and advanced vascular surgeons using lifelike pulsatile vascular surgical training models.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective-To evaluate pulsed-wave Doppler spectral parameters as a method for distinguishing between neoplastic and inflammatory peripheral lymphadenopathy in dogs. Sample Population-40 superficial lymph nodes from 33 dogs with peripheral lymphadenopathy. Procedures-3 Doppler spectral tracings were recorded from each node. Spectral Doppler analysis including assessment of the resistive index, peak systolic velocity-to-end diastolic velocity (S:D) ratio, diastolic notch velocity-to-peak systolic velocity (N:S) ratio, and end diastolic velocity-to-diastolic notch velocity ratio was performed for each tracing. Several calculation methods were used to determine the Doppler indices for each lymph node. After the ultrasonographic examination, fine needle aspirates or excisional biopsy specimens of the examined lymph nodes were obtained, and lymphadenopathy was classified as either inflammatory or neoplastic (lymphomatous or metastatic) via cytologic or histologic examination. Results of Doppler analysis were compared with cytologic or histopathologic findings. Results-The Doppler index with the highest diagnostic accuracy was the S:D ratio calculated from the first recorded tracing; a cutoff value of 3.22 yielded sensitivity of 91%, specificity of 100%, and negative predictive value of 89% for detection of neoplasia. Overall diagnostic accuracy was 95%. At a sensitivity of 100%, the most accurate index was the N:S ratio calculated from the first recorded tracing; a cutoff value of 0.45 yielded specificity of 67%, positive predictive value of 81%, and overall diagnostic accuracy of 86.5%. Conclusions and Clinical Relevance-Results suggested that noninvasive Doppler spectral analysis may be useful in the diagnosis of neoplastic versus inflammatory peripheral lymphadenopathy in dogs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The effect of whole-body vibration dosage on leg blood flow was investigated. Nine healthy young adult males completed a set of 14 random vibration and non-vibration exercise bouts whilst squatting on a Galileo 900 plate. Six vibration frequencies ranging from 5 to 30 Hz (5 Hz increments) were used in combination with a 2.5 mm and 4.5 mm amplitude to produce twelve 1-min vibration bouts. Subjects also completed two 1-min bouts where no vibration was applied. Systolic and diastolic diameters of the common femoral artery and blood cell velocity were measured by an echo Doppler ultrasound in a standing or rest condition prior to the bouts and during and after each bout. Repeated measures MANOVAs were used in the statistical analysis. Compared with the standing condition, the exercise bouts produced a four-fold increase in mean blood cell velocity (P<0.001) and a two-fold increase in peak blood cell velocity (P<0.001). Compared to the non-vibration bouts, frequencies of 10-30 Hz increased mean blood cell velocity by approximately 33% (P<0.01) whereas 20-30 Hz increased peak blood cell velocity by approximately 27% (P<0.01). Amplitude was additive to frequency but only achieved significance at 30 Hz (P<0.05). Compared with the standing condition, squatting alone produced significant increases in mean and peak blood cell velocity (P<0.001). The results show leg blood flow increased during the squat or non-vibration bouts and systematically increased with frequency in the vibration bouts.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To test a system with milk flow-controlled pulsation, milk flow was recorded in 29 Holstein cows during machine milking. The three different treatments were routine milking (including a pre-stimulation of 50-70 s), milking with a minimum of teat preparation and milking with milk flow-controlled b-phase, i.e. with a gradually elongated b-phase of the pulsation cycle with increasing milk flow rate and shortening again during decreasing milk flow. For data evaluation the herd was divided into three groups based on the peak flow rate at routine milking (group 1: <3.2 kg/min; group 2: 3.2-4.5 kg/min; group 3: >4.5 kg/min). Compared with routine milking, milking with milk flow-controlled b-phase caused a significant elevation of the peak flow rate and the duration of incline lasted longer especially in cows with a peak flow rate of >3.2 kg/min in routine milking. In milking with a minimum of teat preparation the duration of incline lasted longer compared with the two other treatments. Bimodality of milk flow, i.e. delayed milk ejection at the start of milking, was most frequent at milking with a minimum of teat preparation. No significant differences between routine milking and milking with milk flow-controlled b-phase were detected for all other milking characteristics. In summary, milking with milk flow-controlled b-phase changes the course of milk removal, however mainly in cows with high peak flow rates.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE To determine the pulmonary venous flow velocity (PVFV) values in a large normal population. DESIGN Prospective study in consecutive individuals. SETTING University hospital. METHODS Among 404 normal individuals, the flow velocity pattern in the right upper pulmonary vein was recorded in 315 subjects using transthoracic echocardiography, and in both upper pulmonary veins in 100 subjects using transoesophageal echocardiography. Subjects were divided into five age groups. The PVFV values were compared between transthoracic and transoesophageal echocardiography within the age groups, and intraindividually between the right and left upper pulmonary veins in transoesophageal echocardiography. RESULTS Normal PVFV values for the right upper pulmonary vein in transthoracic and transoesophageal echocardiography are presented. The duration of flow reversal at atrial contraction was overestimated using transthoracic echocardiography (mean (SD): 96 (21) ms in transoesophageal echocardiography, 120 (28) ms in transthoracic echocardiography, p < 0.0001). Systolic to diastolic peak flow velocity ratio (S:D) increased earlier with advancing age with transoesophageal echocardiography than with transthoracic echocardiography. Similar results were found for the corresponding time-velocity integrals. Data from the left and right upper pulmonary veins differed with respect to onset and deceleration of flow velocities, but not for flow durations or peak velocities. CONCLUSIONS Normal PVFV values generally show a wide range. The data presented will be of value in assessing left ventricular diastolic function and mitral regurgitation using the PVFV pattern.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Neutral hydrogen atoms that travel into the heliosphere from the local interstellar medium (LISM) experience strong effects due to charge exchange and radiation pressure from resonant absorption and re-emission of Lyα. The radiation pressure roughly compensates for the solar gravity. As a result, interstellar hydrogen atoms move along trajectories that are quite different than those of heavier interstellar species such as helium and oxygen, which experience relatively weak radiation pressure. Charge exchange leads to the loss of primary neutrals from the LISM and the addition of new secondary neutrals from the heliosheath. IBEX observations show clear effects of radiation pressure in a large longitudinal shift in the peak of interstellar hydrogen compared with that of interstellar helium. Here, we compare results from the Lee et al. interstellar neutral model with IBEX-Lo hydrogen observations to describe the distribution of hydrogen near 1 AU and provide new estimates of the solar radiation pressure. We find over the period analyzed from 2009 to 2011 that radiation pressure divided by the gravitational force (μ) has increased slightly from μ = 0.94 ± 0.04 in 2009 to μ = 1.01 ± 0.05 in 2011. We have also derived the speed, temperature, source longitude, and latitude of the neutral H atoms and find that these parameters are roughly consistent with those of interstellar He, particularly when considering the filtration effects that act on H in the outer heliosheath. Thus, our analysis shows that over the period from 2009 to 2011, we observe signatures of neutral H consistent with the primary distribution of atoms from the LISM and a radiation pressure that increases in the early rise of solar activity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Heart failure with preserved ejection fraction (HFpEF) is remarkably common in elderly people with highly prevalent comorbid conditions. Despite its increasing in prevalence, there is no evidence-based effective therapy for HFpEF. We sought to evaluate whether inspiratory muscle training (IMT) improves exercise capacity, as well as left ventricular diastolic function, biomarker profile and quality of life (QoL) in patients with advanced HFpEF and nonreduced maximal inspiratory pressure (MIP). DESIGN AND METHODS A total of 26 patients with HFpEF (median (interquartile range) age, peak exercise oxygen uptake (peak VO2) and left ventricular ejection fraction of 73 years (66-76), 10 ml/min/kg (7.6-10.5) and 72% (65-77), respectively) were randomized to receive a 12-week programme of IMT plus standard care vs. standard care alone. The primary endpoint of the study was evaluated by positive changes in cardiopulmonary exercise parameters and distance walked in 6 minutes (6MWT). Secondary endpoints were changes in QoL, echocardiogram parameters of diastolic function, and prognostic biomarkers. RESULTS The IMT group improved significantly their MIP (p < 0.001), peak VO2 (p < 0.001), exercise oxygen uptake at anaerobic threshold (p = 0.001), ventilatory efficiency (p = 0.007), metabolic equivalents (p < 0,001), 6MWT (p < 0.001), and QoL (p = 0.037) as compared to the control group. No changes on diastolic function parameters or biomarkers levels were observed between both groups. CONCLUSIONS In HFpEF patients with low aerobic capacity and non-reduced MIP, IMT was associated with marked improvement in exercise capacity and QoL.