2 resultados para Operational performance

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

40.00% 40.00%

Publicador:

Resumo:

BackgroundThe aim of the present study was to evaluate the feasibility of using a telephone survey in gaining an understanding of the possible herd and management factors influencing the performance (i.e. safety and efficacy) of a vaccine against porcine circovirus type 2 (PCV2) in a large number of herds and to estimate customers¿ satisfaction.ResultsDatasets from 227 pig herds that currently applied or have applied a PCV2 vaccine were analysed. Since 1-, 2- and 3-site production systems were surveyed, the herds were allocated in one of two subsets, where only applicable variables out of 180 were analysed. Group 1 was comprised of herds with sows, suckling pigs and nursery pigs, whereas herds in Group 2 in all cases kept fattening pigs. Overall 14 variables evaluating the subjective satisfaction with one particular PCV2 vaccine were comingled to an abstract dependent variable for further models, which was characterized by a binary outcome from a cluster analysis: good/excellent satisfaction (green cluster) and moderate satisfaction (red cluster). The other 166 variables comprised information about diagnostics, vaccination, housing, management, were considered as independent variables. In Group 1, herds using the vaccine due to recognised PCV2 related health problems (wasting, mortality or porcine dermatitis and nephropathy syndrome) had a 2.4-fold increased chance (1/OR) of belonging to the green cluster. In the final model for Group 1, the diagnosis of diseases other than PCV2, the reason for vaccine administration being other than PCV2-associated diseases and using a single injection of iron had significant influence on allocating into the green cluster (P¿<¿0.05). In Group 2, only unchanged time or delay of time of vaccination influenced the satisfaction (P¿<¿0.05).ConclusionThe methodology and statistical approach used in this study were feasible to scientifically assess ¿satisfaction¿, and to determine factors influencing farmers¿ and vets¿ opinion about the safety and efficacy of a new vaccine.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work applies higher order auxiliary excitation techniques to two types of quadrupole mass spectrometers (QMSs): commercial systems and spaceborne instruments. The operational settings of a circular rod geometry commercial system and an engineering test-bed for a hyperbolic rod geometry spaceborne instrument were matched, with the relative performance of each sensor characterized with and without applied excitation using isotopic measurements of Kr+. Each instrument was operated at the limit of the test electronics to determine the effect of auxiliary excitation on extending instrument capabilities. For the circular rod sensor, with applied excitation, a doubling of the mass resolution at 1% of peak transmission resulted from the elimination of the low-mass side peak tail typical of such rod geometries. The mass peak stability and ion rejection efficiency were also increased by factors of 2 and 10, respectively, with voltage scan lines passing through the center of stability islands formed from auxiliary excitation. Auxiliary excitation also resulted in factors of 6 and 2 in peak stability and ion rejection efficiency, respectively, for the hyperbolic rod sensor. These results not only have significant implications for the use of circular rod quadrupoles with applied excitation as a suitable replacement for traditional hyperbolic rod sensors, but also for extending the capabilities of existing hyperbolic rod QMSs for the next generation of spaceborne instruments and low-mass commercial systems.