13 resultados para OVERDENTURE

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study summarizes the long-term clinical observations of edentulous patients treated with mandibular implant-supported overdentures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: In the present cohort study, overdentures with a combined root and implant support were evaluated and compared with either exclusively root- or implant-supported overdentures. Results of a 2-year follow-up period are reported, namely survival of implants, root copings, and prostheses, plus prosthetic complications, maintenance service, and patient satisfaction. MATERIALS AND METHODS: Fourteen patients were selected for the combined overdenture therapy and were compared with 2 patient groups in which either roots or implants provided overdenture support. Altogether, 14, 17, and 15 patients (in groups 1, 2, and 3, respectively) were matched with regard to age, sex, treatment time, and observation period. The mean age was around 67 years. Periodontal parameters were recorded, radiographs were taken, and all complications and failures were registered during the entire observation time. The patients answered a 9-item questionnaire by means of a visual analogue scale (VAS). RESULTS: One implant failed and 1 tooth root was removed following longitudinal root fracture. Periodontal/peri-implant parameters gave evidence of good oral hygiene for roots and implants, and slight crestal bone resorption was measured for both. Technical complications and service performed were significantly higher in the first year (P < .04) in all 3 groups and significantly higher in the tooth root group (P < .03). The results of the VAS indicated significantly lower scores for satisfaction, speaking ability, wearing comfort, and denture stability with combined or exclusive root support (P < .05 and .02, respectively). Initial costs of overdentures with combined or root support were 10% lower than for implant overdentures. CONCLUSION: The concept of combined root and implant support can be integrated into treatment planning and overdenture design for patients with a highly reduced dentition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This case report presents the treatment sequence of a 56 years old patient after he developed periimplantitis at the implant in position of tooth 22. This implant was integrated in an overdenture reconstruction connected to a soldered screw retained gold bar. The entire 2-stage procedure of implant explantation, simultaneous bone augmentation and new implant placement is documented. The onlay-graft was performed by means of the Transfer-Ring-Control System (Meisinger). The existing gold bar could be resoldered and adapted to the new implant. Accordingly the overdenture was relined and the female retainer mounted. The treatment period covered almost one year.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: The mandibular implant overdenture is a popular treatment modality and is well documented in the literature. Follow-up studies with a long observation period are difficult to perform due to the increasing age of patients. The present data summarize a long-term clinical observation of patients with implant overdentures. MATERIALS AND METHODS: Between 1984 and 1997, edentulous patients were consecutively admitted for treatment with an implant overdenture. The dentures were connected to the implants by means of bars or ball anchors. Regular maintenance was provided with at least one or two scheduled visits per year. Recall attendance and reasons for dropout were analyzed based on the specific history of the patient. Denture maintenance service, relining, repair, and fabrication of new dentures were identified, and complications with the retention devices specified separately. RESULTS: In the time period from 1984 to 2008, 147 patients with a total of 314 implants had completed a follow-up period of >10 years. One hundred one patients were still available in 2008, while 46 patients were not reexamined for various reasons. Compliance was high, with a regular recall attendance of >90%. More than 80% of dentures remained in continuous service. Although major prosthetic maintenance was rather low in relation to the long observation period, visits to a dental hygienist and dentist resulted in an annual visit rate of 1.5 and 2.4, respectively. If new dentures became necessary, these were made in student courses, which increased the treatment time and number of appointments needed. Complications with the retention devices consisted mostly of the mounting of new female retainers, the repair of bars, and the changing of ball anchors. The average number of events and the rate of prosthetic service with ball anchors were significantly higher than those with bars. Twenty-two patients changed from ball anchors to bars; 9 patients switched from a clip bar to a rigid U-shaped bar. CONCLUSIONS: This long-term follow-up study demonstrates that implant overdentures are a favorable solution for edentulous patients with regular maintenance. In spite of specific circumstances in an aging population, it is possible to provide long-term care, resulting in a good prognosis and low risk for this treatment modality. For various reasons the dropout rate can be considerable in elderly patients and prosthetic service must be provided regularly.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This case report documents the prosthetic rehabilitation of a patient showing the typical features of combination syndrome. This case documentation gives a general overview of the suspected development and the prevalence of this "syndrome". A treatment option should be shown by the example of a patient from the starting situation until the prosthetic therapy by means of a complete maxillary denture and an implant-supported mandibular overdenture rigidly retained with a milled bar.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: The use of endosseous dental implants has become common practice for the rehabilitation of edentulous patients, and a two-implant overdenture has been recommended as the standard of care. The use of small-diameter implants may extend treatment options and reduce the necessity for bone augmentation. However, the mechanical strength of titanium is limited, so titanium alloys with greater tensile and fatigue strength may be preferable. Purpose: This randomized, controlled, double-blind, multicenter study investigated in a split-mouth model whether small-diameter implants made from Titanium-13Zirconium alloy (TiZr, Roxolid™) perform at least as well as Titanium Grade IV implants. Methods and Materials: Patients with an edentulous mandible received one TiZr and one Ti Grade IV small-diameter bone level implant (3.3 mm, SLActive®) in the interforaminal region. The site distribution was randomized and double-blinded. Outcome measures included change in radiological peri-implant bone level from surgery to 12 months post-insertion (primary), implant survival, success, soft tissue conditions, and safety (secondary). Results: Of 91 treated patients, 87 were available for the 12-month follow-up. Peri-implant bone level change (-0.3 ± 0.5 mm vs -0.3 ± 0.6 mm), plaque, and sulcus bleeding indices were not significantly different between TiZr and Ti Grade IV implants. Implant survival rates were 98.9 percent and 97.8 percent, success rates were 96.6 percent and 94.4 percent, respectively. Nineteen minor and no serious adverse events were related to the study devices. Conclusion: This study confirms that TiZr small-diameter bone level implants provide at least the same outcomes after 12 months as Ti Grade IV bone level implants. The improved mechanical properties of TiZr implants may extend implant therapy to more challenging clinical situations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Clinical aspects of a simple treatment concept with fixed prostheses in the edentulous jaw are described. Fixed implant-supported reconstructions in the edentulous jaw require multiple implants, are technically complex, aesthetically demanding and metal-ceramic solutions are expensive. Specific surgical techniques to enhance the hard and soft tissue conditions become often necessary. Thus the bar-supported overdenture may be preferred, because problems with aesthetics and alveolar ridge deficiencies can be solved more easily and the number of implants is reduced. Both, the "All-on-Four" technique and the "Procera implant bridge" are simple type of fixed prostheses, comparable to overdentures or complete dentures with regard to design and technology. They present a cost-effective alternative, with predictable aesthetics and optimum passive fit.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: There is evidence for the superiority of two-implant overdentures over complete dentures in the mandible. Various anchorage devices were used to provide stability to overdentures. The aim of the present study was to compare two designs of a rigid bar connecting two mandibular implants. MATERIALS AND METHODS: Completely edentulous patients received a new denture in the maxilla and an implant-supported overdenture in the mandible. They were randomly allocated to two groups (A or B) with regard to the bar design. A standard U-shaped bar (Dolder bar) was used connecting the two implants in a straight line. For comparison, precision attachments were soldered distal to the bar copings. Group A started the study with the standard bar (S-bar), while group B started with the attachment-bar (A-bar). After 3 months, they had to answer a questionnaire (visual analogue scale [VAS]); then the bar design was changed in both groups. After a period of another 3 months, the patients had to answer the same questions; then they had the choice to keep their preferred bar. Now the study period was extended to another year of observation, and the patients answered again the same questionnaire. In vivo force measurements were carried out with both bar types at the end of the test periods. The prosthetic maintenance service carried out during the 6-month period was recorded for both bar types in both groups. Statistical analysis as performed with the SPSS statistical package (SPSS Inc., Chicago, IL, USA). RESULTS: Satisfaction was high in both groups. Group B, who had entered the study with the attachment bar, gave slightly better ratings to this type for four items, while in group A, no differences were found. At the end of the 6-month comparison period, all but one patient wished to continue to wear the attachment bar. Prosthetic service was equal in groups A and B, but the total number of interventions is significantly higher in the attachment bar. Force patterns of maximum biting were similar in both bar designs, but exhibited significantly higher axial forces in the attachment bar. CONCLUSIONS: Both bar designs provide good retention and functional comfort. High stability appears to be an important factor for the patients' satisfaction and oral comfort. Rigid retention results in a higher force impact and appears to evoke the need for the retightening of occlusal screws, resulting in more maintenance service.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Resonance frequency analysis (RFA) is a method of measuring implant stability. However, little is known about RFA of implants with long loading periods. The objective of the present study was to determine standard implant stability quotients (ISQs) for clinical successfully osseointegrated 1-stage implants in the edentulous mandible. MATERIALS AND METHODS: Stability measurements by means of RFA were performed in regularly followed patients who had received 1- stage implants for overdenture support. The time interval between implant placement and measurement ranged from 1 year up to 10 years. The short-term group comprised patients who were followed up to 5 years, while the long-term group included patients with an observation time of > 5 years up to 10 years. For further comparison RFA measurements were performed in a matching group with unloaded implants at the end of the surgical procedure. For statistical analysis various parameters that might influence the ISQs of loaded implants were included, and a mixed-effects model applied (regression analysis, P <.0125). RESULTS: Ninety-four patients were available with a total of 205 loaded implants, and 16 patients with 36 implants immediately after the surgical procedure. The mean ISQ of all measured implants was 64.5 +/- 7.9 (range, 58 to 72). Statistical analysis did not reveal significant differences in the mean ISQ related to the observation time. The parameters with overall statistical significance were the diameter of the implants and changes in the attachment level. In the short-term group, the gender and the clinically measured attachment level had a significant effect. Implant diameter had a significant effect in the long-term group. CONCLUSIONS: A mean ISQ of 64.5 +/- 7.9 was found to be representative for stable asymptomatic interforaminal implants measured by the RFA instrument at any given time point. No significant differences in ISQ values were found between implants with different postsurgical time intervals. Implant diameter appears to influence the ISQ of interforaminal implants.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To systematically appraise the impact of mechanical/technical risk factors on implant-supported reconstructions. MATERIAL AND METHODS: A MEDLINE (PubMed) database search from 1966 to April 2008 was conducted. The search strategy was a combination of MeSH terms and the key words: design, dental implant(s), risk, prosthodontics, fixed prosthodontics, fixed partial denture(s), fixed dental prosthesis (FDP), fixed reconstruction(s), oral rehabilitation, bridge(s), removable partial denture(s), overdenture(s). Randomized controlled trials, controlled trials, and prospective and retrospective cohort studies with a mean follow-up of at least 4 years were included. The material evaluated in each study had to include cases with/without exposure to the risk factor. RESULTS: From 3,568 articles, 111 were selected for full text analysis. Of the 111 articles, 33 were included for data extraction after grouping the outcomes into 10 risk factors: type of retentive elements supporting overdentures, presence of cantilever extension(s), cemented versus screw-retained FDPs, angled/angulated abutments, bruxism, crown/implant ratio, length of the suprastructure, prosthetic materials, number of implants supporting an FDP, and history of mechanical/technical complications. CONCLUSIONS: The absence of a metal framework in overdentures, the presence of cantilever extension(s) > 15 mm and of bruxism, the length of the reconstruction, and a history of repeated complications were associated with increased mechanical/technical complications. The type of retention, the presence of angled abutments, the crown-implant ratio, and the number of implants supporting an FDP were not associated with increased mechanical/technical complications. None of the mechanical/technical risk factors had an impact on implant survival and success rates.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: To analyze computer-assisted diagnostics and virtual implant planning and to evaluate the indication for template-guided flapless surgery and immediate loading in the rehabilitation of the edentulous maxilla. MATERIALS AND METHODS: Forty patients with an edentulous maxilla were selected for this study. The three-dimensional analysis and virtual implant planning was performed with the NobelGuide software program (Nobel Biocare, Göteborg, Sweden). Prior to the computer tomography aesthetics and functional aspects were checked clinically. Either a well-fitting denture or an optimized prosthetic setup was used and then converted to a radiographic template. This allowed for a computer-guided analysis of the jaw together with the prosthesis. Accordingly, the best implant position was determined in relation to the bone structure and prospective tooth position. For all jaws, the hypothetical indication for (1) four implants with a bar overdenture and (2) six implants with a simple fixed prosthesis were planned. The planning of the optimized implant position was then analyzed as follows: the number of implants was calculated that could be placed in sufficient quantity of bone. Additional surgical procedures (guided bone regeneration, sinus floor elevation) that would be necessary due the reduced bone quality and quantity were identified. The indication of template-guided, flapless surgery or an immediate loaded protocol was evaluated. RESULTS: Model (a) - bar overdentures: for 28 patients (70%), all four implants could be placed in sufficient bone (total 112 implants). Thus, a full, flapless procedure could be suggested. For six patients (15%), sufficient bone was not available for any of their planned implants. The remaining six patients had exhibited a combination of sufficient or insufficient bone. Model (b) - simple fixed prosthesis: for 12 patients (30%), all six implants could be placed in sufficient bone (total 72 implants). Thus, a full, flapless procedure could be suggested. For seven patients (17%), sufficient bone was not available for any of their planned implants. The remaining 21 patients had exhibited a combination of sufficient or insufficient bone. DISCUSSION: In the maxilla, advanced atrophy is often observed, and implant placement becomes difficult or impossible. Thus, flapless surgery or an immediate loading protocol can be performed just in a selected number of patients. Nevertheless, the use of a computer program for prosthetically driven implant planning is highly efficient and safe. The three-dimensional view of the maxilla allows the determination of the best implant position, the optimization of the implant axis, and the definition of the best surgical and prosthetic solution for the patient. Thus, a protocol that combines a computer-guided technique with conventional surgical procedures becomes a promising option, which needs to be further evaluated and improved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES This clinical study measured the dimensional changes of existing lower complete dentures due to the integration of a prefabricated implant bar. Additionally, the impact of this dimensional change on patient satisfaction and oral function was analyzed. METHODS Twenty edentulous patients (10 men/10 women; aged 65.9 ± 11.8 years) received two interforaminal implants. Subsequent to surgery, a chair side adapted, prefabricated bar (SFI Bar(®), C+M, Biel, Switzerland) was inserted, and the matrix was polymerized into the existing lower denture. The change of the denture's lingual dimension was recorded by means of a bicolored, silicone denture duplicate that was sectioned in the oro-vestibular direction in the regions of the symphysis (S) and the implants (I-left, I-right). On the sections, the dimensional increase was measured using a light microscope. Six months after bar insertion, patients answered a standardized questionnaire. RESULTS All dentures exhibited increased lingual volume, more extensively at S than at I (P = 0.001). At S, the median diagonal size of the denture was doubled (+4.33 mm), and at I, the median increase was 50% (I-left/-right = +2.66/+2.62 mm). The original denture size influenced the volume increase (P = 0.024): smaller dentures led to a larger increase. The amount of denture increase did not have negative impact on either self-perceived oral function or patient satisfaction. Approximately, 95% of the patients were satisfied with the treatment results. CONCLUSIONS The lingual size of a lower denture was enlarged by the integration of a prefabricated bar without any negative side effects. Thus, this attachment system is suitable to convert an existing full denture into an implant-supported overdenture.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Implant-overdentures supported by rigid bars provide stability in the edentulous atrophic mandible. However, fractures of solder joints and matrices, and loosening of screws and matrices were observed with soldered gold bars (G-bars). Computer-aided designed/computer-assisted manufactured (CAD/CAM) titanium bars (Ti-bars) may reduce technical complications due to enhanced material quality. PURPOSE To compare prosthetic-technical maintenance service of mandibular implant-overdentures supported by CAD/CAM Ti-bar and soldered G-bar. MATERIALS AND METHODS Edentulous patients were consecutively admitted for implant-prosthodontic treatment with a maxillary complete denture and a mandibular implant-overdenture connected to a rigid G-bar or Ti-bar. Maintenance service and problems with the implant-retention device complex and the prosthesis were recorded during minimally 3-4 years. Annual peri-implant crestal bone level changes (ΔBIC) were radiographically assessed. RESULTS Data of 213 edentulous patients (mean age 68 ± 10 years), who had received a total of 477 tapered implants, were available. Ti-bar and G-bar comprised 101 and 112 patients with 231 and 246 implants, respectively. Ti-bar mostly exhibited distal bar extensions (96%) compared to 34% of G-bar (p < .001). Fracture rate of bars extensions (4.7% vs 14.8%, p < .001) and matrices (1% vs 13%, p < .001) was lower for Ti-bar. Matrices activation was required 2.4× less often in Ti-bar. ΔBIC remained stable for both groups. CONCLUSIONS Implant overdentures supported by soldered gold bars or milled CAD/CAM Ti-bars are a successful treatment modality but require regular maintenance service. These short-term observations support the hypothesis that CAD/CAM Ti-bars reduce technical complications. Fracture location indicated that the titanium thickness around the screw-access hole should be increased.