50 resultados para MR-IMAGES

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

n this paper we present a novel hybrid approach for multimodal medical image registration based on diffeomorphic demons. Diffeomorphic demons have proven to be a robust and efficient way for intensity-based image registration. A very recent extension even allows to use mutual information (MI) as a similarity measure to registration multimodal images. However, due to the intensity correspondence uncertainty existing in some anatomical parts, it is difficult for a purely intensity-based algorithm to solve the registration problem. Therefore, we propose to combine the resulting transformations from both intensity-based and landmark-based methods for multimodal non-rigid registration based on diffeomorphic demons. Several experiments on different types of MR images were conducted, for which we show that a better anatomical correspondence between the images can be obtained using the hybrid approach than using either intensity information or landmarks alone.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Medical doctors often do not trust the result of fully automatic segmentations because they have no possibility to make corrections if necessary. On the other hand, manual corrections can introduce a user bias. In this work, we propose to integrate the possibility for quick manual corrections into a fully automatic segmentation method for brain tumor images. This allows for necessary corrections while maintaining a high objectiveness. The underlying idea is similar to the well-known Grab-Cut algorithm, but here we combine decision forest classification with conditional random field regularization for interactive segmentation of 3D medical images. The approach has been evaluated by two different users on the BraTS2012 dataset. Accuracy and robustness improved compared to a fully automatic method and our interactive approach was ranked among the top performing methods. Time for computation including manual interaction was less than 10 minutes per patient, which makes it attractive for clinical use.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper we propose a new fully-automatic method for localizing and segmenting 3D intervertebral discs from MR images, where the two problems are solved in a unified data-driven regression and classification framework. We estimate the output (image displacements for localization, or fg/bg labels for segmentation) of image points by exploiting both training data and geometric constraints simultaneously. The problem is formulated in a unified objective function which is then solved globally and efficiently. We validate our method on MR images of 25 patients. Taking manually labeled data as the ground truth, our method achieves a mean localization error of 1.3 mm, a mean Dice metric of 87%, and a mean surface distance of 1.3 mm. Our method can be applied to other localization and segmentation tasks.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper addresses the problem of fully-automatic localization and segmentation of 3D intervertebral discs (IVDs) from MR images. Our method contains two steps, where we first localize the center of each IVD, and then segment IVDs by classifying image pixels around each disc center as foreground (disc) or background. The disc localization is done by estimating the image displacements from a set of randomly sampled 3D image patches to the disc center. The image displacements are estimated by jointly optimizing the training and test displacement values in a data-driven way, where we take into consideration both the training data and the geometric constraint on the test image. After the disc centers are localized, we segment the discs by classifying image pixels around disc centers as background or foreground. The classification is done in a similar data-driven approach as we used for localization, but in this segmentation case we are aiming to estimate the foreground/background probability of each pixel instead of the image displacements. In addition, an extra neighborhood smooth constraint is introduced to enforce the local smoothness of the label field. Our method is validated on 3D T2-weighted turbo spin echo MR images of 35 patients from two different studies. Experiments show that compared to state of the art, our method achieves better or comparable results. Specifically, we achieve for localization a mean error of 1.6-2.0 mm, and for segmentation a mean Dice metric of 85%-88% and a mean surface distance of 1.3-1.4 mm.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

PURPOSE: To evaluate diffusion-weighted magnetic resonance (MR) imaging of the human placenta in fetuses with and fetuses without intrauterine growth restriction (IUGR) who were suspected of having placental insufficiency. MATERIALS AND METHODS: The study was approved by the local ethics committee, and written informed consent was obtained. The authors retrospectively evaluated 1.5-T fetal MR images from 102 singleton pregnancies (mean gestation ± standard deviation, 29 weeks ± 5; range, 21-41 weeks). Morphologic and diffusion-weighted MR imaging were performed. A region of interest analysis of the apparent diffusion coefficient (ADC) of the placenta was independently performed by two observers who were blinded to clinical data and outcome. Placental insufficiency was diagnosed if flattening of the growth curve was detected at obstetric ultrasonography (US), if the birth weight was in the 10th percentile or less, or if fetal weight estimated with US was below the 10th percentile. Abnormal findings at Doppler US of the umbilical artery and histopathologic examination of specimens from the placenta were recorded. The ADCs in fetuses with placental insufficiency were compared with those in fetuses of the same gestational age without placental insufficiency and tested for normal distribution. The t tests and Pearson correlation coefficients were used to compare these results at 5% levels of significance. RESULTS: Thirty-three of the 102 pregnancies were ultimately categorized as having an insufficient placenta. MR imaging depicted morphologic changes (eg, infarction or bleeding) in 27 fetuses. Placental dysfunction was suspected in 33 fetuses at diffusion-weighted imaging (mean ADC, 146.4 sec/mm(2) ± 10.63 for fetuses with placental insufficiency vs 177.1 sec/mm(2) ± 18.90 for fetuses without placental insufficiency; P < .01, with one false-positive case). The use of diffusion-weighted imaging in addition to US increased sensitivity for the detection of placental insufficiency from 73% to 100%, increased accuracy from 91% to 99%, and preserved specificity at 99%. CONCLUSION: Placental dysfunction associated with growth restriction is associated with restricted diffusion and reduced ADC. A decreased ADC used as an early marker of placental damage might be indicative of pregnancy complications such as IUGR.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

PURPOSE: To determine the effect of two pairs of echo times (TEs) for in-phase (IP) and opposed-phase (OP) 3.0-T magnetic resonance (MR) imaging on (a) quantitative analysis prospectively in a phantom study and (b) diagnostic accuracy retrospectively in a clinical study of adrenal tumors, with use of various reference standards in the clinical study. MATERIALS AND METHODS: A fat-saline phantom was used to perform IP and OP 3.0-T MR imaging for various fat fractions. The institutional review board approved this HIPAA-compliant study, with waiver of informed consent. Single-breath-hold IP and OP 3.0-T MR images in 21 patients (14 women, seven men; mean age, 63 years) with 23 adrenal tumors (16 adenomas, six metastases, one adrenocortical carcinoma) were reviewed. The MR protocol involved two acquisition schemes: In scheme A, the first OP echo (approximately 1.5-msec TE) and the second IP echo (approximately 4.9-msec TE) were acquired. In scheme B, the first IP echo (approximately 2.4-msec TE) and the third OP echo (approximately 5.8-msec TE) were acquired. Quantitative analysis was performed, and analysis of variance was used to test for differences between adenomas and nonadenomas. RESULTS: In the phantom study, scheme B did not enable discrimination among voxels that had small amounts of fat. In the clinical study, no overlap in signal intensity (SI) index values between adenomas and nonadenomas was seen (P < .05) with scheme A. However, with scheme B, no overlap in the adrenal gland SI-to-liver SI ratio between adenomas and nonadenomas was seen (P < .05). With scheme B, no overlap in adrenal gland SI index-to-liver SI index ratio between adenomas and nonadenomas was seen (P < .05). CONCLUSION: This initial experience indicates SI index is the most reliable parameter for characterization of adrenal tumors with 3.0-T MR imaging when obtaining OP echo before IP echo. When acquiring IP echo before OP echo, however, nonadenomas can be mistaken as adenomas with use of the SI index value.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVES: Implementation of an experimental model to compare cartilage MR imaging by means of histological analyses. MATERIAL AND METHODS: MRI was obtained from 4 patients expecting total knee replacement at 1.5 and/or 3T prior surgery. The timeframe between pre-op MRI and knee replacement was within two days. Resected cartilage-bone samples were tagged with Ethi((R))-pins to reproduce the histological cutting course. Pre-operative scanning at 1.5T included following parameters for fast low angle shot (FLASH: TR/TE/FA=33ms/6ms/30 degrees , BW=110kHz, 120mmx120mm FOV, 256x256 matrix, 0.65mm slice-thickness) and double echo steady state (DESS: TR/TE/FA=23.7ms/6.9ms/40 degrees , BW=130kHz, 120x120mm FOV, 256x256 matrix, 0.65mm slice-thickness). At 3T, scan parameters were: FLASH (TR/TE/FA=12.2ms/5.1ms/10 degrees , BW=130kHz, 170x170mm FOV, 320x320, 0.5mm slice-thickness) and DESS (TR/TE/FA=15.6ms/4.5ms/25 degrees , BW=200kHz, 135mmx150mm FOV, 288x320matrix, 0.5mm slice-thickness). Imaging of the specimens was done the same day at 1.5T. MRI (Noyes) and histological (Mankin) score scales were correlated using the paired t-test. Sensitivity and specificity for the detection of different grades of cartilage degeneration were assessed. Inter-reader and intra-reader reliability was determined using Kappa analysis. RESULTS: Low correlation (sensitivity, specificity) was found for both sequences in normal to mild Mankin grades. Only moderate to severe changes were diagnosed with higher significance and specificity. The use of higher field-strengths was advantageous for both protocols with sensitivity values ranging from 13.6% to 93.3% (FLASH) and 20.5% to 96.2% (DESS). Kappa values ranged from 0.488 to 0.944. CONCLUSIONS: Correlating MR images with continuous histological slices was feasible by using three-dimensional imaging, multi-planar-reformat and marker pins. The capability of diagnosing early cartilage changes with high accuracy could not be proven for both FLASH and DESS.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

PURPOSE: To evaluate whether proposed diagnostic criteria applied to magnetic resonance (MR) images of patients with laryngeal and hypopharyngeal carcinoma may be used to distinguish neoplastic from inflammatory involvement of the laryngeal cartilages. MATERIALS AND METHODS: The radiologic and histopathologic data in 121 consecutive patients with primary squamous cell carcinoma of the larynx (n = 63) or hypopharynx (n = 58) who underwent MR imaging before laryngectomy formed the basis of this retrospective study. Patient consent for retrospective chart review was waived by the institutional review board. All laryngectomy specimens were processed with a dedicated histopathologic whole-organ slice technique. MR images were evaluated by two readers according to established ("old") and proposed ("new") diagnostic criteria on the basis of the signal intensity behavior of cartilage on T2-weighted images and contrast material-enhanced T1-weighted images compared with that of the adjacent tumor. Specifically, with the new criteria, T2-weighted or postcontrast T1-weighted cartilage signal intensity greater than that of the adjacent tumor was considered to indicate inflammation, and signal intensity similar to that of the adjacent tumor was considered to indicate neoplastic invasion. The results of the MR image interpretation were compared with the histologic reference standard. RESULTS: The area under the receiver operating characteristic curve for the new criteria (0.94) was nominally but significantly larger than that for the old criteria (0.92) (P = .01). Overall specificity was significantly improved (82% for new vs 74% for old criteria, P < .001) and was greatest for the thyroid cartilage (75% for new vs 54% for old criteria, P < .001) with the new criteria. The sensitivities of the established and the proposed criteria were identical. CONCLUSION: The proposed MR imaging criteria enable improved differentiation of neoplastic cartilage invasion from peritumoral inflammation.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

PURPOSE: To compare dynamic contrast material-enhanced magnetic resonance (MR) imaging and diffusion-weighted MR imaging for noninvasive evaluation of early and late effects of a vascular targeting agent in a rat tumor model. MATERIALS AND METHODS: The study protocol was approved by the local ethics committee for animal care and use. Thirteen rats with one rhabdomyosarcoma in each flank (26 tumors) underwent dynamic contrast-enhanced imaging and diffusion-weighted echo-planar imaging in a 1.5-T MR unit before intraperitoneal injection of combretastatin A4 phosphate and at early (1 and 6 hours) and later (2 and 9 days) follow-up examinations after the injection. Histopathologic examination was performed at each time point. The apparent diffusion coefficient (ADC) of each tumor was calculated separately on the basis of diffusion-weighted images obtained with low b gradient values (ADC(low); b = 0, 50, and 100 sec/mm(2)) and high b gradient values (ADC(high); b = 500, 750, and 1000 sec/mm(2)). The difference between ADC(low) and ADC(high) was used as a surrogate measure of tissue perfusion (ADC(low) - ADC(high) = ADC(perf)). From the dynamic contrast-enhanced MR images, the volume transfer constant k and the initial slope of the contrast enhancement-time curve were calculated. For statistical analyses, a paired two-tailed Student t test and linear regression analysis were used. RESULTS: Early after administration of combretastatin, all perfusion-related parameters (k, initial slope, and ADC(perf)) decreased significantly (P < .001); at 9 days after combretastatin administration, they increased significantly (P < .001). Changes in ADC(perf) were correlated with changes in k (R(2) = 0.46, P < .001) and the initial slope (R(2) = 0.67, P < .001). CONCLUSION: Both dynamic contrast-enhanced MR imaging and diffusion-weighted MR imaging allow monitoring of perfusion changes induced by vascular targeting agents in tumors. Diffusion-weighted imaging provides additional information about intratumoral cell viability versus necrosis after administration of combretastatin.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

PURPOSE We tested the hypothesis that whiplash trauma leads to changes of the signal intensity of cervical discs in T2-weighted images. METHODS AND MATERIALS 50 whiplash patients (18-65 years) were examined within 48h after motor vehicle accident, and again after 3 and 6 months and compared to 50 age- and sex-matched controls. Signal intensity in ROI's of the discs at the levels C2/3 to C7/T1 and the adjacent vertebral bodies were measured on sagittal T2 weighted MR images and normalized using the average of ROI's in fat tissue. The contrast between discs and both adjacent vertebrae was calculated and disc degeneration was graded by the Pfirrmann-grading system. RESULTS Whiplash trauma did not have a significant effect on the normalized signals from discs and vertebrae, on the contrast between discs and adjacent vertebrae, or on the Pfirrmann grading. However, the contrast between discs and adjacent vertebrae and the Pfirrmann grading showed a strong correlation. In healthy volunteers, the contrast between discs and adjacent vertebrae and Pfirrmann grading increased with age and was dependent on the disc level. CONCLUSION We could not find any trauma related changes of cervical disc signal intensities. Normalized signals of discs and Pfirrmann grading changed with age and varied between disc levels with the used MR sequence.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Purpose To provide normal values of the cervical spinal canal and spinal cord dimensions in several planes with respect to spinal level, age, sex, and body height. Materials and Methods This study was approved by the institutional review board; all individuals provided signed informed consent. In a prospective multicenter study, two blinded raters independently examined cervical spine magnetic resonance (MR) images of 140 healthy volunteers who were white. The midsagittal diameters and areas of spinal canal and spinal cord, respectively, were measured at the midvertebral levels of C1, C3, and C6. A multivariate general linear model described the influence of sex, body height, age, and spinal level on the measured values. Results There were differences for sex, spinal level, interaction between sex and level, and body height, while age had significant yet limited influence. Normative ranges for the sagittal diameters and areas of spinal canal and spinal cord were defined at C1, C3, and C6 levels for men and women. In addition to a calculation of normative ranges for a specific sex, spinal level, age, and body height data, data for three different height subgroups at 45 years of age were extracted. These results show a range of the spinal canal dimensions at C1 (from 10.7 to 19.7 mm), C3 (from 9.4 to 17.2 mm), and C6 (from 9.2 to 16.8 mm) levels. Conclusion : The dimensions of the cervical spinal canal and cord in healthy individuals are associated with spinal level, sex, age, and height. © RSNA, 2013 Online supplemental material is available for this article.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Image-based modeling of tumor growth combines methods from cancer simulation and medical imaging. In this context, we present a novel approach to adapt a healthy brain atlas to MR images of tumor patients. In order to establish correspondence between a healthy atlas and a pathologic patient image, tumor growth modeling in combination with registration algorithms is employed. In a first step, the tumor is grown in the atlas based on a new multi-scale, multi-physics model including growth simulation from the cellular level up to the biomechanical level, accounting for cell proliferation and tissue deformations. Large-scale deformations are handled with an Eulerian approach for finite element computations, which can operate directly on the image voxel mesh. Subsequently, dense correspondence between the modified atlas and patient image is established using nonrigid registration. The method offers opportunities in atlasbased segmentation of tumor-bearing brain images as well as for improved patient-specific simulation and prognosis of tumor progression.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

PURPOSE To prospectively assess the diagnostic performance of diffusion-weighted (DW) magnetic resonance (MR) imaging in the detection of pelvic lymph node metastases in patients with prostate and/or bladder cancer staged as N0 with preoperative cross-sectional imaging. MATERIALS AND METHODS This study was approved by an independent ethics committee. Written informed consent was obtained from all patients. Patients with no enlarged lymph nodes on preoperative cross-sectional images who were scheduled for radical resection of the primary tumor and extended pelvic lymph node dissection were enrolled. All patients were examined with a 3-T MR unit, and examinations included conventional and DW MR imaging of the entire pelvis. Image analysis was performed by three independent readers blinded to any clinical information. Metastases were diagnosed on the basis of high signal intensity on high b value DW MR images and morphologic features (shape, border). Histopathologic examination served as the standard of reference. Sensitivity and specificity were calculated, and bias-corrected 95% confidence intervals (CIs) were obtained with the bootstrap method. The Fleiss and Cohen κ and median test were applied for statistical analyses. RESULTS A total of 4846 lymph nodes were resected in 120 patients. Eighty-eight lymph node metastases were found in 33 of 120 patients (27.5%). Short-axis diameter of these metastases was less than or equal to 3 mm in 68, more than 3 mm to 5 mm in 13, more than 5 mm to 8 mm in five; and more than 8 mm in two. On a per-patient level, the three readers correctly detected metastases in 26 (79%; 95% CI: 64%, 91%), 21 (64%; 95% CI: 45%, 79%), and 25 (76%; 95% CI: 60%, 90%) of the 33 patients with metastases, with respective specificities of 85% (95% CI: 78%, 92%), 79% (95% CI: 70%, 88%), and 84% (95% CI: 76%, 92%). Analyzed according to hemipelvis, lymph node metastases were detected with histopathologic examination in 44 of 240 pelvic sides (18%); the three readers correctly detected these on DW MR images in 26 (59%; 95% CI: 45%, 73%), 19 (43%; 95% CI: 27%, 57%), and 28 (64%; 95% CI: 47%, 78%) of the 44 cases. CONCLUSION DW MR imaging enables noninvasive detection of small lymph node metastases in normal-sized nodes in a substantial percentage of patients with prostate and bladder cancer diagnosed as N0 with conventional cross-sectional imaging techniques.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Image-based modeling of tumor growth combines methods from cancer simulation and medical imaging. In this context, we present a novel approach to adapt a healthy brain atlas to MR images of tumor patients. In order to establish correspondence between a healthy atlas and a pathologic patient image, tumor growth modeling in combination with registration algorithms is employed. In a first step, the tumor is grown in the atlas based on a new multi-scale, multi-physics model including growth simulation from the cellular level up to the biomechanical level, accounting for cell proliferation and tissue deformations. Large-scale deformations are handled with an Eulerian approach for finite element computations, which can operate directly on the image voxel mesh. Subsequently, dense correspondence between the modified atlas and patient image is established using nonrigid registration. The method offers opportunities in atlasbased segmentation of tumor-bearing brain images as well as for improved patient-specific simulation and prognosis of tumor progression.