12 resultados para Lead mines and mining

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Lead-gold eutectic (LGE) has been recently proposed as an alternative target material for high power spallation sources. In order to compare the corrosive properties of LGE to the better-studied eutectic of lead-bismuth (LBE), an isothermal twin-loop made of SS 316L was built and operated at the Institute of Physics of the University of Latvia. We have measured the concentration of steel alloying elements dissolved in both alloys at the end of two test campaigns via ICP-OES. In case of LGE, a pronounced concentration increase of Fe, Ni, Mn and Cr is found in the liquid metal, which is significantly higher compared to LBE. Similar results were obtained during complementary investigations on material samples exposed to both alloys in this twin-loop at 400 ◦C and 450 ◦C. These findings indicate that in contact with LGE, SS 316L steel suffers from substantial chemical attack. Detailed investigations using structure materials other than SS 316L have to be undertaken before qualifying LGE as a serious alternative to LBE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A continuous record of atmospheric lead since 12,370 carbon-14 years before the present (14C yr BP) is preserved in a Swiss peat bog. Enhanced fluxes caused by climate changes reached their maxima 10,590 14C yr BP (Younger Dryas) and 823014C yr BP. Soil erosion caused by forest clearing and agricultural tillage increased lead deposition after 532014C yr BP. Increasing lead/scandium and decreasing lead-206/lead-207 beginning 3000 14C yr BP indicate the beginning of lead pollution from mining and smelting, and anthropogenic sources have dominated lead emissions ever since. The greatest lead flux (15.7 milligrams per square meter per year in A.D. 1979) was 1570 times the natural, background value (0.01 milligram per square meter per year from 8030 to 5320 14C yr BP).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To investigate whether prolonged sacral neuromodulation (SNM) testing induces a substantial risk of infection because of the percutaneous passage of the extension wire. PATIENTS AND METHODS: A consecutive series of 20 patients with negative prolonged SNM testing for >or=14 days who underwent tined-lead explantation were prospectively evaluated. The explanted tined leads were sent for microbiological examination. The tined lead, gluteal, and extension wire incision sites were investigated for clinical signs of infection according to the Centers for Disease Control and Prevention classification system. RESULTS: In all, 17 patients had bilateral and three unilateral implanted tined leads. The median (range) test period was 30 (21-62 days). Bacterial growth (Staphylococcus species) was detected in four of 20 (20%) patients on seven of 37 (19%) explanted tined leads. There were clinical signs of infection in one of 20 (5%) patients at none of 37 tined lead, one of 20 (5%) gluteal, and none of 20 extension wire incision sites. There were no clinical signs of infection in the remaining three of four patients with bacterial growth. CONCLUSIONS: After prolonged tined-lead testing, we found an infection rate comparable to that reported with the usual short test period. In addition, most patients with bacterial growth on tined leads showed no clinical signs of infection. Thus, prolonged tined-lead testing does not seem to induce clinically relevant infection, warranting randomized trials.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: Prolonged sacral neuromodulation (SNM) testing is more reliable for accurate patient selection than the usual test period of 4-7 days. However, prolonged testing was suspected to result in a higher complication rate due to infection via the percutaneous passage of the extension wire. Therefore, we prospectively assessed the complications associated with prolonged tined lead testing. PATIENTS AND METHODS: A consecutive series of 44 patients who underwent prolonged tined lead testing for at least 14 days between May 2002 and April 2007 were evaluated. Complications during prolonged tined lead testing, during and after tined lead explantation and during follow-up after implantation of the implantable pulse generator (IPG) were registered prospectively. RESULTS: Four patients suffered from urgency-frequency syndrome, 13 from urge incontinence, 18 from non-obstructive chronic urinary retention and nine from chronic pelvic pain syndrome. The median test phase was 30 days (interquartile range [IQR] 21-36). Thirty-two of the 44 patients (73%) had successful prolonged tined lead testing and 31 of these (97%) underwent the implantation of the IPG. The median follow-up of the IPG implanted patients was 31 months (IQR 20-41). The complication rate was 5% (2/44) during prolonged tined lead testing and 16% (5/31) during follow-up of the IPG implanted patients, respectively. None of the complications could be attributed to prolonged testing. No infections were observed during the study period. CONCLUSIONS: This prospective, observational non-randomised study suggests prolonged SNM tined lead testing is a safe procedure. Based on the low complication rate and the increased reliability for accurate patient selection, this method is proposed as a possible standard test procedure, subject to confirmation by further randomised, controlled clinical studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Long-term electrocardiography (ECG) featuring adequate atrial and ventricular signal quality is highly desirable. Routinely used surface leads are limited in atrial signal sensitivity and recording capability impeding complete ECG delineation, i.e. in the presence of supraventricular arrhythmias. Long-term esophageal ECG might overcome these limitations but requires a dedicated lead system and recorder design. To this end, we analysed multiple-lead esophageal ECGs with respect to signal quality by describing the ECG waves as a function of the insertion level, interelectrode distance, electrode shape and amplifier's input range. The results derived from clinical data show that two bipolar esophageal leads, an atrial lead with short (15 mm) interelectrode distance and a ventricular lead with long (80 mm) interelectrode distance provide non-inferior ventricular signal strength and superior atrial signal strength compared to standard surface lead II. High atrial signal slope in particular is observed with the atrial esophageal lead. The proposed esophageal lead system in combination with an increased recorder input range of ±20 mV minimizes signal loss due to excessive electrode motion typically observed in esophageal ECGs. The design proposal might help to standardize long-term esophageal ECG registrations and facilitate novel ECG classification systems based on the independent detection of ventricular and atrial electrical activity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Several natural products derived from entomopathogenic fungi have been shown to initiate neuronal differentiation in the rat pheochromocytoma PC12 cell line. After the successful completion of the total synthesis program, the reduction of structural complexity while retaining biological activity was targeted. In this study, farinosone C served as a lead structure and inspired the preparation of small molecules with reduced complexity, of which several were able to induce neurite outgrowth. This allowed for the elaboration of a detailed structure-activity relationship. Investigations on the mode of action utilizing a computational similarity ensemble approach suggested the involvement of the endocannabinoid system as potential target for our analogs and also led to the discovery of four potent new endocannabinoid transport inhibitors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE Abnormal ECG findings suggestive of cardiac disease are frequent in patients with funnel chest, although structural heart disease is rare. Electrocardiographic characteristics and changes following new surgical treatments in young adults are not described so far. The aim of the study was to analyze electrocardiographic characteristics of patients with funnel chest before and after minimally invasive funnel chest correction by the Nuss procedure. METHODS Twenty-six patients with surgical correction of funnel chest using pectus bar were included. Twelve-lead ECGs before and later than one year after surgery were analyzed. RESULTS In postoperative ECGs, amplitude of P wave in lead II and negative terminal amplitude of P wave in lead V1 decreased from 0.13 to 0.10mV (p=0.03), and from 0.10 to 0.04mV (p<0.001), respectively. Mean QRS duration decreased from 108ms to 98ms (p=0.003) after correction. A pathological left and right Sokolow-Lyon index was observed in 35% and 23% of patients before, versus 8% (p=0.04) and 0% (p=0.01) after correction, respectively. In contrast, the rate of patients with J wave pattern in precordial leads V4-V6 increased from 8% before to 42% after surgery (p=0.004). CONCLUSIONS ECG abnormalities in patients with funnel chest are frequent, and can normalize after surgical correction by the Nuss procedure. De novo J wave pattern in precordial leads V4-V6 is a frequent finding after surgical funnel chest correction using pectus bar.