14 resultados para International Commission
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
In 2009, the International Commission on Radiological Protection issued a statement on radon which stated that the dose conversion factor for radon progeny would likely double, and the calculation of risk from radon should move to a dosimetric approach, rather than the longstanding epidemiological approach. Through the World Nuclear Association, whose members represent over 90% of the world's uranium production, industry has been examining this issue with a goal of offering expertise and knowledge to assist with the practical implementation of these evolutionary changes to evaluating the risk from radon progeny. Industry supports the continuing use of the most current epidemiological data as a basis for risk calculation, but believes that further examination of these results is needed to better understand the level of conservatism in the potential epidemiological-based risk models. With regard to adoption of the dosimetric approach, industry believes that further work is needed before this is a practical option. In particular, this work should include a clear demonstration of the validation of the dosimetric model which includes how smoking is handled, the establishment of a practical measurement protocol, and the collection of relevant data for modern workplaces. Industry is actively working to address the latter two items.
Resumo:
OBJECTIVES: To analyse the results of recent studies not yet included in a 2003 report of the International Commission on Non-Ionizing Radiation Protection (ICNIRP) on occupational exposure to low-frequency electromagnetic fields as potential risk factor for neurodegenerative diseases. METHODS: A literature search was conducted in the online databases of PubMed, ISI Web of Knowledge, DIMDI and COCHRANE, as well as in specialised databases and journals. Eight studies published between January 2000 and July 2005 were included in the review. RESULTS: The findings of these studies contribute to the evidence of an association between occupational magnetic field exposure and the risk of dementia. Regarding amyotrophic lateral sclerosis, the recent results confirm earlier observations of an association with electric and electronic work and welding. Its relationship with magnetic field exposure remains unsolved. There are only few findings pointing towards an association between magnetic field exposure and Parkinson's disease. CONCLUSIONS: The epidemiological evidence for an association between occupational exposure to low-frequency electromagnetic fields and the risk of dementia has increased during the last five years. The impact of potential confounders should be evaluated in further studies.
Resumo:
This article is a systematic review of whether everyday exposure to radiofrequency electromagnetic field (RF-EMF) causes symptoms, and whether some individuals are able to detect low-level RF-EMF (below the ICNIRP [International Commission on Non-Ionizing Radiation Protection] guidelines). Peer-reviewed articles published before August 2007 were identified by means of a systematic literature search. Meta-analytic techniques were used to pool the results from studies investigating the ability to discriminate active from sham RF-EMF exposure. RF-EMF discrimination was investigated in seven studies including a total of 182 self-declared electromagnetic hypersensitive (EHS) individuals and 332 non-EHS individuals. The pooled correct field detection rate was 4.2% better than expected by chance (95% CI: -2.1 to 10.5). There was no evidence that EHS individuals could detect presence or absence of RF-EMF better than other persons. There was little evidence that short-term exposure to a mobile phone or base station causes symptoms based on the results of eight randomized trials investigating 194 EHS and 346 non-EHS individuals in a laboratory. Some of the trials provided evidence for the occurrence of nocebo effects. In population based studies an association between symptoms and exposure to RF-EMF in the everyday environment was repeatedly observed. This review showed that the large majority of individuals who claims to be able to detect low level RF-EMF are not able to do so under double-blind conditions. If such individuals exist, they represent a small minority and have not been identified yet. The available observational studies do not allow differentiating between biophysical from EMF and nocebo effects.
Resumo:
Radiation dose delivered from the SCANORA radiography unit during the cross-sectional mode for dentotangential projections was determined. With regard to oral implantology, patient situations of an edentulous maxilla and mandible as well as a single tooth gap in regions 16 and 46 were simulated. Radiation doses were measured between 0.2 and 22.5 mGy to organs and tissues in the head and neck region when the complete maxilla or mandible was examined. When examining a single tooth gap, only 8% to 40% of that radiation dose was generally observed. Based on these results, the mortality risk was estimated according to a calculation model recommended by the Committee on the Biological Effects of Ionizing Radiations. The mortality risk ranged from 31.4 x 10(-6) for 20-year-old men to 4.8 x 10(-6) for 65-year-old women when cross-sectional imaging of the complete maxilla was performed. The values decreased by 70% when a single tooth gap in the molar region of the maxilla was radiographed. The figures for the mortality risk for examinations of the complete mandible were similar to those for the complete maxilla, but the mortality risk decreased by 80% if only a single tooth gap in the molar region of the mandible was examined. Calculations according to the International Commission on Radiological Protection carried out for comparison did not reveal the decrease of the mortality risk with age and resulted in a higher risk value in comparison to the group of 35-year old individuals in calculations according to the Committee on the Biological Effects of Ionizing Radiations.
Resumo:
In the present study, dose measurements have been conducted following examination of the maxilla and mandible with spiral computed tomography (CT). The measurements were carried out with 2 phantoms, a head and neck phantom and a full body phantom. The analysis of applied thermoluminescent dosimeters yielded radiation doses for organs and tissues in the head and neck region between 0.6 and 16.7 mGy when 40 axial slices and 120 kV/165 mAs were used as exposure parameters. The effective dose was calculated as 0.58 and 0.48 mSv in the maxilla and mandible, respectively. Tested methods for dose reduction showed a significant decrease of radiation dose from 40 to 65%. Based on these results, the mortality risk was estimated according to calculation models recommended by the Committee on the Biological Effects of Ionizing Radiations and by the International Commission on Radiological Protection. Both models resulted in similar values. The mortality risk ranges from 46.2 x 10.6 for 20-year-old men to 11.2 x 10(-6) for 65-year-old women. Using 2 methods of dose reduction, the mortality risk decreased by approximately 50 to 60% to 19.1 x 10(-6) for 20-year-old men and 5.5 x 10(-6) for 65-year-old women. It can be concluded that a CT scan of the maxillofacial complex causes a considerable radiation dose when compared with conventional radiographic examinations. Therefore, a careful indication for this imaging technique and dose reduction methods should be considered in daily practice.
Resumo:
STUDY DESIGN: A prospective case control study design was conducted. OBJECTIVES: The purpose of the current study was to determine the intraoperative radiation hazard to spine surgeons by occupational radiation exposure during percutaneous vertebroplasty and possible consequences with respect to radiation protection. SUMMARY OF BACKGROUND DATA: The development of minimally invasive surgery techniques has led to an increasing number of fluoroscopically guided procedures being done percutaneously such as vertebroplasty, which is the percutaneous cement augmentation of vertebral bodies. METHODS: Three months of occupational dose data for two spine surgeons was evaluated measuring the radiation doses to the thyroid gland, the upper extremities, and the eyes during vertebroplasty. RESULTS: The annual risk of developing a fatal cancer of the thyroid is 0.0025%, which means a very small to small risk. The annual morbidity (the risk of developing a cancer including nonfatal ones) is 0.025%, which already means a small to medium risk. The dose for the eye lens was about 8% of the threshold dose to develop a radiation induced cataract (150 mSv); therefore, the risk is very low but not negligible. The doses measured for the skin are 10% of the annual effective dose limit (500 mSv) recommended by the ICRP (International Commission on Radiologic Protection); therefore, the annual risk for developing a fatal skin cancer is very low. CONCLUSION: While performing percutaneous vertebroplasty, the surgeon is exposed to a significant amount of radiation. Proper surgical technique and shielding devices to decrease potentially high morbidity are mandatory. Training in radiation protection should be an integral part of the education for all surgeons using minimally invasive radiologic-guided interventional techniques.
Resumo:
RATIONALE AND OBJECTIVES: The aim of this study was to measure the radiation dose of dual-energy and single-energy multidetector computed tomographic (CT) imaging using adult liver, renal, and aortic imaging protocols. MATERIALS AND METHODS: Dual-energy CT (DECT) imaging was performed on a conventional 64-detector CT scanner using a software upgrade (Volume Dual Energy) at tube voltages of 140 and 80 kVp (with tube currents of 385 and 675 mA, respectively), with a 0.8-second gantry revolution time in axial mode. Parameters for single-energy CT (SECT) imaging were a tube voltage of 140 kVp, a tube current of 385 mA, a 0.5-second gantry revolution time, helical mode, and pitch of 1.375:1. The volume CT dose index (CTDI(vol)) value displayed on the console for each scan was recorded. Organ doses were measured using metal oxide semiconductor field-effect transistor technology. Effective dose was calculated as the sum of 20 organ doses multiplied by a weighting factor found in International Commission on Radiological Protection Publication 60. Radiation dose saving with virtual noncontrast imaging reconstruction was also determined. RESULTS: The CTDI(vol) values were 49.4 mGy for DECT imaging and 16.2 mGy for SECT imaging. Effective dose ranged from 22.5 to 36.4 mSv for DECT imaging and from 9.4 to 13.8 mSv for SECT imaging. Virtual noncontrast imaging reconstruction reduced the total effective dose of multiphase DECT imaging by 19% to 28%. CONCLUSION: Using the current Volume Dual Energy software, radiation doses with DECT imaging were higher than those with SECT imaging. Substantial radiation dose savings are possible with DECT imaging if virtual noncontrast imaging reconstruction replaces precontrast imaging.
Resumo:
The comparison of radiotherapy techniques regarding secondary cancer risk has yielded contradictory results possibly stemming from the many different approaches used to estimate risk. The purpose of this study was to make a comprehensive evaluation of different available risk models applied to detailed whole-body dose distributions computed by Monte Carlo for various breast radiotherapy techniques including conventional open tangents, 3D conformal wedged tangents and hybrid intensity modulated radiation therapy (IMRT). First, organ-specific linear risk models developed by the International Commission on Radiological Protection (ICRP) and the Biological Effects of Ionizing Radiation (BEIR) VII committee were applied to mean doses for remote organs only and all solid organs. Then, different general non-linear risk models were applied to the whole body dose distribution. Finally, organ-specific non-linear risk models for the lung and breast were used to assess the secondary cancer risk for these two specific organs. A total of 32 different calculated absolute risks resulted in a broad range of values (between 0.1% and 48.5%) underlying the large uncertainties in absolute risk calculation. The ratio of risk between two techniques has often been proposed as a more robust assessment of risk than the absolute risk. We found that the ratio of risk between two techniques could also vary substantially considering the different approaches to risk estimation. Sometimes the ratio of risk between two techniques would range between values smaller and larger than one, which then translates into inconsistent results on the potential higher risk of one technique compared to another. We found however that the hybrid IMRT technique resulted in a systematic reduction of risk compared to the other techniques investigated even though the magnitude of this reduction varied substantially with the different approaches investigated. Based on the epidemiological data available, a reasonable approach to risk estimation would be to use organ-specific non-linear risk models applied to the dose distributions of organs within or near the treatment fields (lungs and contralateral breast in the case of breast radiotherapy) as the majority of radiation-induced secondary cancers are found in the beam-bordering regions.
Resumo:
This paper presents a multifactor approach for performance assessment of Water Users Associations (WUAs) in Uzbekistan in order to identify the drivers for improved and effi cient performance of WUAs. The study was carried out in the Fergana Valley where the WUAs were created along the South Fergana Main Canal during the last 10 years. The farmers and the employees of 20 WUAs were questioned about the WUAs’ activities and the quantitative and qualitative data were obtained. This became a base for the calculation of 36 indicators divided into 6 groups: Water supply, technical conditions, economic conditions, social and cultural conditions, organizational conditions and information conditions. All the indicators assessed with a differentiated point system adjusted for subjectivity of several of them give the total maximal result for the associations of 250 point. The WUAs of the Fergana Valley showed the score between 145 and 219 points, what refl ects a highly diverse level of the WUAs performance in the region. The analysis of the indicators revealed that the key points of the WUA’s success are the organizational and institutional conditions including the participatory factors and awareness of both the farmers and employees about the work of WUA. The research showed that the low performance of the WUAs is always explained by the low technical and economic conditions along with weak organization and information dissemination conditions. It is clear that it is complicated to improve technical and economic conditions immediately because they are cost-based and cost-induced. However, it is possible to improve the organizational conditions and to strengthen the institutional basis via formal and information institutions which will gradually lead to improvement of economic and technical conditions of WUAs. Farmers should be involved into the WUA Governance and into the process of making common decisions and solving common problems together via proper institutions. Their awareness can also be improved by leading additional trainings for increasing farmers’ agronomic and irrigation knowledge, teaching them water saving technologies and acquainting them with the use of water measuring equipment so it can bring reliable water supply, transparent budgeting and adequate as well as equitable water allocation to the water users.
Resumo:
BACKGROUND Providing the highest quality care for dying patients should be a core clinical proficiency and an integral part of comprehensive management, as fundamental as diagnosis and treatment. The aim of this study was to provide expert consensus on phenomena for identification and prediction of the last hours or days of a patient's life. This study is part of the OPCARE9 project, funded by the European Commission's Seventh Framework Programme. METHOD The phenomena associated with approaching death were generated using Delphi technique. The Delphi process was set up in three cycles to collate a set of useful and relevant phenomena that identify and predict the last hours and days of life. Each cycle included: (1) development of the questionnaire, (2) distribution of the Delphi questionnaire and (3) review and synthesis of findings. RESULTS The first Delphi cycle of 252 participants (health care professionals, volunteers, public) generated 194 different phenomena, perceptions and observations. In the second cycle, these phenomena were checked for their specific ability to diagnose the last hours/days of life. Fifty-eight phenomena achieved more than 80% expert consensus and were grouped into nine categories. In the third cycle, these 58 phenomena were ranked by a group of palliative care experts (78 professionals, including physicians, nurses, psycho-social-spiritual support; response rate 72%, see Table 1) in terms of clinical relevance to the prediction that a person will die within the next few hours/days. Twenty-one phenomena were determined to have "high relevance" by more than 50% of the experts. Based on these findings, the changes in the following categories (each consisting of up to three phenomena) were considered highly relevant to clinicians in identifying and predicting a patient's last hours/days of life: "breathing", "general deterioration", "consciousness/cognition", "skin", "intake of fluid, food, others", "emotional state" and "non-observations/expressed opinions/other". CONCLUSION Experts from different professional backgrounds identified a set of categories describing a structure within which clinical phenomena can be clinically assessed, in order to more accurately predict whether someone will die within the next days or hours. However, these phenomena need further specification for clinical use.