19 resultados para Internal standard
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
The micellar electrokinetic capillary chromatography (MEKC) separation and analysis of voriconazole and UK 115794 (internal standard) were examined and an assay for determination of voriconazole in human plasma and serum was developed. The MEKC medium comprises a 2:15 (v/v) mixture of methanol and a pH 9.3 buffer composed of 5mM Na(2)B(4)O(7), 7 mM Na(2)HPO(4) and 54 mM SDS. Sample preparation is based upon liquid/liquid extraction with ethylacetate and dichloromethane (75%/25%) at physiological pH. Using this approach with 250 microl serum or plasma and reconstitution of the dried extract into 100 microl of a buffer composed of 0.5mM Na(2)B(4)O(7) and 0.7 mM Na(2)HPO(4) (pH 9.3), the detection and quantitation limits were determined to be 0.1 and 0.2 microg/ml, respectively, a sensitivity that is suitable for therapeutic drug monitoring of voriconazole (provisional therapeutic range: 1-6 microg/ml) in human plasma and serum samples. The method was validated and compared to an HPLC method, showing excellent agreement between the two for a set of 91 samples that stemmed from patients being treated with voriconazole. The MEKC assay is also demonstrated to be suitable to explore pharmacokinetic data of voriconazole.
Resumo:
This paper reports an LC-MS/MS method with positive electrospray ionization for the screening of commonly prescribed cardiovascular drugs in human plasma, including compounds with antihypertensive (57), antidiabetic (12), hypolipemiant (5), anticoagulant (2) and platelet anti-aggregation (2) effects. Sample treatment consisted of a simple protein precipitation with MeOH/0.1 M ZnSO₄ (4:1, v/v) solution after the addition of internal standard, followed by evaporation and reconstitution. Analytes separation was performed on a Polar-RP column (150 m x 2 mm, 4 μm) using a gradient elution of 15 min. The MS system was operated in MRM mode, monitoring one quantitation and one confirmation transition for each analyte. The recovery of the protein precipitation step ranged from 50 to 70% for most of the compounds, while some were considerably affected by matrix effects. Since several analytes fulfilled the linearity, accuracy and precision values required by the ICH guidelines, the method proved to be suitable for their quantitative analysis. The limits of quantitation varied from 0.38 to 9.1 μg/L and the limits of detection from 0.12 to 5.34 μg/L. The method showed to be suitable for the detection of plasma samples of patients under cardiovascular treatment with the studied drugs, and for 55 compounds reliable quantitative results could be obtained.
Resumo:
Phosphatidylethanol (PEth) is an abnormal phospholipid carrying two fatty acid chains. It is only formed in the presence of ethanol via the action of phospholipase D (PLD). Its use as a biomarker for alcohol consumption is currently under investigation. Previous methods for the analysis of PEth included high-performance liquid chromatography (HPLC) coupled to an evaporative light scattering detector (ELSD), which is unspecific for the different homologues--improved methods are now based on time of flight mass spectrometry (TOF-MS) and tandem mass spectrometry (MS/MS). The intention of this work was to identify as many homologues of PEth as possible. A screening procedure using multiple-reaction monitoring (MRM) for the identified homologues has subsequently been established. For our investigations, autopsy blood samples collected from heavy drinkers were used. Phosphatidylpropanol 16:0/18:1 (internal standard) was added to the blood samples prior to liquid-liquid extraction using borate buffer (pH 9), 2-propanol and n-hexane. After evaporation, the samples were redissolved in the mobile phase and injected into the LC-MS/MS system. Compounds were separated on a Luna Phenyl Hexyl column (50 mm x 2 mm, 3 microm) by gradient elution, using 2 mM ammonium acetate and methanol/acetone (95/5; v/v). A total of 48 homologues of PEth could be identified by using precursor ion and enhanced product ion scans (EPI).
Resumo:
Telomeres have emerged as crucial cellular elements in aging and various diseases including cancer. To measure the average length of telomere repeats in cells, we describe our protocols that use fluorescent in situ hybridization (FISH) with labeled peptide nucleic acid (PNA) probes specific for telomere repeats in combination with fluorescence measurements by flow cytometry (flow FISH). Flow FISH analysis can be performed using commercially available flow cytometers, and has the unique advantage over other methods for measuring telomere length of providing multi-parameter information on the length of telomere repeats in thousands of individual cells. The accuracy and reproducibility of the measurements is augmented by the automation of most pipetting (aspiration and dispensing) steps, and by including an internal standard (control cells) with a known telomere length in every tube. The basic protocol for the analysis of nucleated blood cells from 22 different individuals takes about 12 h spread over 2-3 days.
Resumo:
Ethyl glucuronide (EtG) is a marker of recent alcohol consumption. For the optimization of the analysis of EtG by CZE with indirect absorbance detection, the use of capillaries with permanent and dynamic wall coatings, the composition of the BGE, and various sample preparation procedures, including dilution with water, ultrafiltration, protein precipitation, and SPE, were investigated. Two validated screening assays for the determination of EtG in human serum, a CZE-based approach and an enzyme immunoassay (EIA), are described. The CZE assay uses a coated capillary, 2,4-dimethylglutaric acid as an internal standard, and a pH 4.65 BGE comprising 9 mM nicotinic acid, epsilon-aminocaproic acid and 10% v/v ACN. Proteins are removed via precipitation with ACN prior to analysis and the LOQ is 0.50 mg/L. The EIA is based upon commercial reagents which are promoted for the determination of urinary EtG. Krebs-Ringer solution containing 5% BSA is used as a calibration matrix. All samples are ultrafiltered prior to analysis of the ultrafiltrate on a Mira Plus analyzer. Assay calibration ranged between 0 and 2 mg/L and the upper reference limit was determined to be 0.05 mg/L. Both assays proved to be suitable for the analysis of samples from different individuals. For EtG levels above 0.50 mg/L, good agreement was observed for the comparison of the results of the two methods.
Resumo:
QUESTION UNDER STUDY To establish at what stage Swiss hospitals are in implementing an internal standard concerning communication with patients and families after an error that resulted in harm. METHODS Hospitals were identified via the Swiss Hospital Association's website. An anonymous questionnaire was sent during September and October 2011 to 379 hospitals in German, French or Italian. Hospitals were asked to specify their hospital type and the implementation status of an internal hospital standard that decrees that patients or their relatives are to be promptly informed about medical errors that result in harm. RESULTS Responses from a total of 205 hospitals were received, a response rate of 54%. Most responding hospitals (62%) had an error disclosure standard or planned to implement one within 12 months. The majority of responding university and acute care (75%) hospitals had introduced a disclosure standard or were planning to do so. In contrast, the majority of responding psychiatric, rehabilitation and specialty (53%) clinics had not introduced a standard. CONCLUSION It appears that Swiss hospitals are in a promising state in providing institutional support for practitioners disclosing medical errors to patients. This has been shown internationally to be one important factor in encouraging the disclosure of medical errors. However, many hospitals, in particular psychiatric, rehabilitation and specialty clinics, have not implemented an error disclosure policy. Further research is needed to explore the underlying reasons.
Resumo:
This study describes the development and validation of a gas chromatography-mass spectrometry (GC-MS) method to identify and quantitate phenytoin in brain microdialysate, saliva and blood from human samples. A solid-phase extraction (SPE) was performed with a nonpolar C8-SCX column. The eluate was evaporated with nitrogen (50°C) and derivatized with trimethylsulfonium hydroxide before GC-MS analysis. As the internal standard, 5-(p-methylphenyl)-5-phenylhydantoin was used. The MS was run in scan mode and the identification was made with three ion fragment masses. All peaks were identified with MassLib. Spiked phenytoin samples showed recovery after SPE of ≥94%. The calibration curve (phenytoin 50 to 1,200 ng/mL, n = 6, at six concentration levels) showed good linearity and correlation (r² > 0.998). The limit of detection was 15 ng/mL; the limit of quantification was 50 ng/mL. Dried extracted samples were stable within a 15% deviation range for ≥4 weeks at room temperature. The method met International Organization for Standardization standards and was able to detect and quantify phenytoin in different biological matrices and patient samples. The GC-MS method with SPE is specific, sensitive, robust and well reproducible, and is therefore an appropriate candidate for the pharmacokinetic assessment of phenytoin concentrations in different human biological samples.
Resumo:
In this study, the development of a new sensitive method for the analysis of alpha-dicarbonyls glyoxal (G) and methylglyoxal (MG) in environmental ice and snow is presented. Stir bar sorptive extraction with in situ derivatization and liquid desorption (SBSE-LD) was used for sample extraction, enrichment, and derivatization. Measurements were carried out using high-performance liquid chromatography coupled to electrospray ionization tandem mass spectrometry (HPLC-ESI-MS/MS). As part of the method development, SBSE-LD parameters such as extraction time, derivatization reagent, desorption time and solvent, and the effect of NaCl addition on the SBSE efficiency as well as measurement parameters of HPLC-ESI-MS/MS were evaluated. Calibration was performed in the range of 1–60 ng/mL using spiked ultrapure water samples, thus incorporating the complete SBSE and derivatization process. 4-Fluorobenzaldehyde was applied as internal standard. Inter-batch precision was <12 % RSD. Recoveries were determined by means of spiked snow samples and were 78.9 ± 5.6 % for G and 82.7 ± 7.5 % for MG, respectively. Instrumental detection limits of 0.242 and 0.213 ng/mL for G and MG were achieved using the multiple reaction monitoring mode. Relative detection limits referred to a sample volume of 15 mL were 0.016 ng/mL for G and 0.014 ng/mL for MG. The optimized method was applied for the analysis of snow samples from Mount Hohenpeissenberg (close to the Meteorological Observatory Hohenpeissenberg, Germany) and samples from an ice core from Upper Grenzgletscher (Monte Rosa massif, Switzerland). Resulting concentrations were 0.085–16.3 ng/mL for G and 0.126–3.6 ng/mL for MG. Concentrations of G and MG in snow were 1–2 orders of magnitude higher than in ice core samples. The described method represents a simple, green, and sensitive analytical approach to measure G and MG in aqueous environmental samples.
An examination chair to measure internal rotation of the hip in routine settings: a validation study
Resumo:
OBJECTIVE: To determine the performance of a newly developed examination chair as compared with the clinical standard of assessing internal rotation (IR) of the flexed hip with a goniometer.
METHODS: The examination chair allowed measurement of IR in a sitting position simultaneously in both hips, with hips and knees flexed 90 degrees, lower legs hanging unsupported and a standardized load of 5 kg applied to both ankles using a bilateral pulley system. Clinical assessment of IR was performed in supine position with hips and knees flexed 90 degrees using a goniometer. Within the framework of a population-based inception cohort study, we calculated inter-observer agreement in two samples of 84 and 64 consecutive, unselected young asymptomatic males using intra-class correlation coefficients (ICC) and determined the correlation between IR assessed with examination chair and clinical assessment.
RESULTS: Inter-observer agreement was excellent for the examination chair (ICC right hip, 0.92, 95% confidence interval [CI] 0.89-0.95; ICC left hip, 0.90, 95% CI 0.86-0.94), and considerably higher than that seen with clinical assessment (ICC right hip, 0.65, 95% CI 0.49-0.77; ICC left hip, 0.69, 95% CI 0.54-0.80, P for difference in ICC between examination chair and clinical assessment
Resumo:
PURPOSE: The purpose of our study was to retrospectively evaluate the specificity, sensitivity and accuracy of computed tomography (CT), digital radiography (DR) and low-dose linear slit digital radiography (LSDR, Lodox(®)) in the detection of internal cocaine containers. METHODS: Institutional review board approval was obtained. The study collectively consisted of 83 patients (76 males, 7 females, 16-45 years) suspected of having incorporated cocaine drug containers. All underwent radiological imaging; a total of 135 exams were performed: nCT=35, nDR=70, nLSDR=30. An overall calculation of all "drug mules" and a specific evaluation of body packers, pushers and stuffers were performed. The gold standard was stool examination in a dedicated holding cell equipped with a drug toilet. RESULTS: There were 54 drug mules identified in this study. CT of all drug carriers showed the highest diagnostic accuracy 97.1%, sensitivity 100% and specificity 94.1%. DR in all cases was 71.4% accurate, 58.3% sensitive and 85.3% specific. LSDR of all patients with internal cocaine was 60% accurate, 57.9% sensitive and 63.4% specific. CONCLUSIONS: CT was the most accurate test studied. Therefore, the detection of internal cocaine drug packs should be performed by CT, rather than by conventional X-ray, in order to apply the most sensitive exam in the medico-legal investigation of suspected drug carriers. Nevertheless, the higher radiation applied by CT than by DR or LSDR needs to be considered. Future studies should include evaluation of low dose CT protocols in order to address germane issues and to reduce dosage.
Resumo:
PRINCIPLES: Coeliac disease (gluten sensitive enteropathy) is a genetically determined disorder with an incidence in the general population that is comparable to type 2 diabetes mellitus. Awareness of this fact and of the often atypical and oligosymptomatic manifestations is only now gaining ground in the medical profession. A high index of suspicion is important in order to minimise diagnostic and therapeutic delay. METHODS: Testing patterns and follow-up for coeliac disease in our institution have been analysed retrospectively for the past five years. The current literature was reviewed with respect to recommendations for clinical practice. RESULTS: A total of 271 patients were tested for coeliac disease over a period of five years. Only in 24 patients were positive results found; after further work-up, the final number of cases with certain or presumed coeliac disease was four. Followup was often difficult, many patients being lost after a single visit. CONCLUSIONS: This study showed that the number of tests ordered in our institution, more often for abdominal than atypical symptoms, has started to increase in the past two years. It also showed that screening tests have found their place in general clinical practice, while the final choice of tests needs to be determined in accordance with available guidelines and local resources. Upper endoscopy with small bowel biopsy remains the gold standard for diagnosis, but its place in follow-up is less certain. Coeliac disease is a disorder for which there is a definite treatment (gluten free diet); if it is left untreated diminished quality of life and potentially serious complications may ensue. Further education of the medical profession regarding coeliac disease, its incidence, presentation and treatment, is clearly indicated..
Resumo:
The objectives of this study were to develop and validate a tool for assessing pain in population-based observational studies and to develop three subscales for back/neck, upper extremity and lower extremity pain. Based on a literature review, items were extracted from validated questionnaires and reviewed by an expert panel. The initial questionnaire consisted of a pain manikin and 34 items relating to (i) intensity of pain in different body regions (7 items), (ii) pain during activities of daily living (18 items) and (iii) various pain modalities (9 items). Psychometric validation of the initial questionnaire was performed in a random sample of the German-speaking Swiss population. Analyses included tests for reliability, correlation analysis, principal components factor analysis, tests for internal consistency and validity. Overall, 16,634 of 23,763 eligible individuals participated (70%). Test-retest reliability coefficients ranged from 0.32 to 0.97, but only three coefficients were below 0.60. Subscales were constructed combining four items for each of the subscales. Item-total coefficients ranged from 0.76 to 0.86 and Cronbach's alpha were 0.75 or higher for all subscales. Correlation coefficients between subscales and three validated instruments (WOMAC, SPADI and Oswestry) ranged from 0.62 to 0.79. The final Pain Standard Evaluation Questionnaire (SEQ Pain) included 28 items and the pain manikin and accounted for the multidimensionality of pain by assessing pain location and intensity, pain during activity, triggers and time of onset of pain and frequency of pain medication. It was found to be reliable and valid for the assessment of pain in population-based observational studies.
Resumo:
OBJECTIVES: To compare the outcome of arthroscopic lysis and lavage of TMJ with internal derangement of Wilkes stages II, III, IV, and V. STUDY DESIGN: Arthroscopic lysis and lavage was performed in 45 TMJ of 39 patients with internal derangement. The cases were divided into 4 groups corresponding to Wilkes stages II, III, IV, and V. Two parameters were compared pre- and postoperatively: pain and mouth opening. Statistical significance was determined using the chi(2) test. RESULTS: Overall success rate was 86.7% (Wilkes stage II 90.9%, Wilkes stage III 92.3%, Wilkes stage IV 84.6%, Wilkes stage V 75%). There were no statistically significant differences between the success rates for Wilkes stages II, III, IV, and V. CONCLUSION: Arthroscopic lysis and lavage should be performed as a standard operation for internal derangement of the TMJ after failure of conservative treatment in all Wilkes stages.
Resumo:
STATEMENT OF PROBLEM: A tapered implant with continuously changing threads purported to provide stable tissue support and allow immediate function has been developed. Treatment success and stabilization of supporting tissues over time require documentation. PURPOSE: The purpose of this prospective, randomized, controlled, multicenter study was to evaluate changes in bone level and soft tissue behavior between the novel implant (NobelActive/NA) and a standard tapered implant (NobelReplace Tapered Groovy/NR) with regard to immediate function. MATERIAL AND METHODS: A total of 177 patients randomly allocated to 3 treatment groups (2 different test implant groups: NA Internal (n=117; internal connection) and External (n=82), and 1 standard treatment group, NR (n=126)) received 325 implants. Implants were placed into healed sites, and all but 6 implants were immediately nonocclusally loaded. Clinical and radiographic evaluations of treatment success, crestal bone levels, and soft tissue changes were performed at the time of placement and after 3, 6, and 12 months. Log-Rank test was used to analyze the differences in survival rate. Marginal bone level was compared using the Kruskal-Wallis test and Mann-Whitney U-test (alpha=.05). RESULTS: One-year cumulative survival rates were comparable (96.6% for NA Internal; 96.3% for NA External; 97.6% for NR; P=.852; Log-Rank). Mean (SD) change in bone level was -0.95 mm (1.37) for NA Internal, -0.64 mm (0.97) for NA External, and -0.63 mm (1.18) for NR (P=.589; Kruskal-Wallis). Stable soft tissues and significantly increased papilla scores (P<.001; Wilcoxon signed-rank) were observed for all implant types. CONCLUSIONS: The novel implants showed high survival rates as well as stable bone and soft tissue levels after 1 year, and may be recommended for clinical use, even under immediate function.
Resumo:
Muscovite B4M, distributed in 1961 as an age standard, was ground under ethanol. Five grain size fractions were obtained and characterized by X-ray diffraction. They display a mixing trend between a phengitic (enriched in the fraction <0.2 µm) and a muscovitic component (predominant in the fraction >20 µm). High-pressure phengite is preserved as a relict in retrograde muscovite. Electron microprobe analyses of the distributed mineral separate reveal at least four white mica populations based on Si, Al, Mg, Na, Fe and F. Rb/K ratios vary by one order of magnitude. Rb–Sr analyses link the mineralogical heterogeneity to variable Rb/Sr and 87Sr/86Sr ratios. The grain size fractions define no internal isochron. Relict fine-grained phengite gives older ages than coarse-grained retrograde greenschist facies muscovite. The inverse grain size–age relationship also characterizes 39Ar/40Ar analyses. Cl/K anticorrelates with step ages: Cl-rich coarse muscovite is younger than Cl-poor fine relict phengite. Sr and Ar preserve a similar isotopic inheritance despite peak metamorphism reaching 635±20 °C. A suitable mineral standard requires that its petrological equilibrium first be demonstrated. Relicts and retrograde reaction textures are a guarantee of isotopic disequilibrium and heterogeneous ages within single crystal at the micrometre scale.