13 resultados para Intellectual evaluation - WISC III
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Rationale: To provide a better understanding of cognitive functioning, motor outcome, behavior and quality of life after childhood stroke and to study the relationship between variables expected to influence rehabilitation and outcome (age at stroke, time elapsed since stroke, lateralization, location and size of lesion). Methods: Children who suffered from stroke between birth and their eighteenth year of life underwent an assessment consisting of cognitive tests (WISC-III, WAIS-R, K-ABC, TAP, Rey-Figure, German Version of the CVLT) and questionnaires (Conner's Scales, KIDSCREEN). Results: Twenty-one patients after stroke in childhood (15 males, mean 11;11 years, SD 4;3, range 6;10-21;2) participated in the study. Mean Intelligence Quotients (IQ) were situated within the normal range (mean Full Scale IQ 96.5, range IQ 79-129). However, significantly more patients showed deficits in various cognitive domains than expected from a healthy population (Performance IQ p = .000; Digit Span p = .000, Arithmetic's p = .007, Divided Attention p = .028, Alertness p = .002). Verbal IQ was significantly better than Performance IQ in 13 of 17 patients, independent of the hemispheric side of lesion. Symptoms of ADHD occurred more often in the patients' sample than in a healthy population (learning difficulties/inattention p = .000; impulsivity/hyperactivity p = .006; psychosomatics p = .006). Certain aspects of quality of life were reduced (autonomy p = .003; parents' relation p = .003; social acceptance p = .037). Three patients had a right-sided hemiparesis, mean values of motor functions of the other patients were slightly impaired (sequential finger movements p = .000, hand alternation p = .001, foot tapping p = .043). In patients without hemiparesis, there was no relation between the lateralization of lesion and motor outcome. Lesion that occurred in the midst of childhood (5-10 years) led to better cognitive outcome than lesion in the very early (0-5 years) or late childhood (10-18 years). Other variables such as presence of seizure, elapsed time since stroke and size of lesion had a small to no impact on prognosis. Conclusion: Moderate cognitive and motor deficits, behavioral problems, and impairment in some aspects of quality of life frequently remain after stroke in childhood. Visuospatial functions are more often reduced than verbal functions, independent of the hemispheric side of lesion. This indicates a functional superiority of verbal skills compared to visuospatial skills in the process of recovery after brain injury. Compared to the cognitive outcome following stroke in adults, cognitive sequelae after childhood stroke do indicate neither the lateralization nor the location of the lesion focus. Age at stroke seems to be the only determining factor influencing cognitive outcome.
Resumo:
OBJECTIVE: Mechanical evaluation of a novel screw position used for repair in a type III distal phalanx fracture model and assessment of solar canal penetration (SCP). STUDY DESIGN: Experimental study. SAMPLE POPULATION: Disarticulated equine hooves (n = 24) and 24 isolated distal phalanges. METHODS: Hooves/distal phalanges cut in a sagittal plane were repaired with 1 of 2 different cortical screw placements in lag fashion. In group 1 (conventional screw placement), the screw was inserted halfway between the proximal border of the solar canal (SC) and the subchondral bone surface on a line parallel to the dorsal cortex, whereas in group 2, the screw was inserted more palmar/plantar, where a perpendicular line drawn from the group 1 position reached the palmar/plantar cortex. Construct strength was evaluated by 3-point bending to failure. SCP was assessed by CT imaging and macroscopically. RESULTS: Screws were significantly longer in group 2 and in forelimbs. Group 2 isolated distal phalanges had a significantly more rigid fixation compared with the conventional screw position (maximum point at failure 31%, bending stiffness 41% higher). Lumen reduction of the SC was observed in 13/52 specimens (all from group 2), of which 9 were forelimbs. CONCLUSIONS: More distal screw positioning compared with the conventionally recommended screw position for internal fixation of type III distal phalangeal fractures allows placement of a longer screw and renders a more rigid fracture fixation. The novel screw position, however, carries a higher risk of SCP
Resumo:
Enhancing osseointegration through surface immobilization of multiple short peptide sequences that mimic extracellular matrix (ECM) proteins, such as arginine-glycine-aspartic acid (RGD) and lysine-arginine-serine-arginine (KRSR), has not yet been extensively explored. Additionally, the effect of biofunctionalizing chemically modified sandblasted and acid-etched surfaces (modSLA) is unknown. The present study evaluated modSLA implant surfaces modified with RGD and KRSR for potentially enhanced effects on bone apposition and interfacial shear strength during early stages of bone regeneration. Two sets of experimental implants were placed in the maxillae of eight miniature pigs, known for their rapid wound healing kinetics: bone chamber implants creating two circular bone defects for histomorphometric analysis on one side and standard thread configuration implants for removal torque testing on the other side. Three different biofunctionalized modSLA surfaces using poly-L-lysine-graft-poly(ethylene glycol) (PLL-g-PEG) as a carrier minimizing nonspecific protein adsorption [(i) 20 pmol cm⁻² KRSR alone (KRSR); or in combination with RGD in two different concentrations; (ii) 0.05 pmol cm⁻² RGD (KRSR/RGD-1); (iii) 1.26 pmol cm⁻² RGD (KRSR/RGD-2)] were compared with (iv) control modSLA. Animals were sacrificed at 2 weeks. Removal torque values (701.48-780.28 N mm), bone-to-implant contact (BIC) (35.22%-41.49%), and new bone fill (28.58%-30.62%) demonstrated no significant differences among treatments. It may be concluded that biofunctionalizing modSLA surfaces with KRSR and RGD derivatives of PLL-g-PEG polymer does not increase BIC, bone fill, or interfacial shear strength.
Resumo:
AIMS: Although an added diagnostic and prognostic value of the global coronary artery calcification (CAC) score as an adjunct to single-photon emission computed tomography (SPECT)-myocardial perfusion image (MPI) has been repeatedly documented, none of the previous studies took advantage of the anatomic information provided by the unenhanced cardiac CT. Therefore, no co-registration has so far been used to match a myocardial perfusion defect with calcifications in the subtending coronary artery. To evaluate the prognostic value of integrating SPECT-MPI with CAC images were obtained from non-enhanced cardiac computed tomography (CT) for attenuation correction to predict major adverse cardiac events (MACE). METHODS AND RESULTS: Follow-up was obtained in 462 patients undergoing a 1-day stress/rest (99m)Tc-teterofosmin SPECT and non-enhanced cardiac CT for attenuation correction. Survival free of MACE was determined using the Kaplan-Meier method. After integrating MPI and CT findings, patients were divided into three groups (i) MPI defect matched by calcification (CAC ≥ 1) in the subtending coronary artery (ii) unmatched MPI and CT finding (iii) normal finding by MPI and CT. At a mean follow-up of 34.5 ± 13 months, a MACE was observed in 80 patients (33 death, 6 non-fatal myocardial infarction, 9 hospitalizations due to unstable angina, and 32 revascularizations). Survival analysis revealed the most unfavourable outcome (P < 0.001 log-rank test) for patients with a matched finding. CONCLUSION: In the present study, a novel approach using a combined integration of cardiac SPECT-CAC imaging allows for refined risk stratification, as a matched defect emerged as an independent predictor of MACE.
Resumo:
OBJECTIVES: To investigate epidemiological, social, diagnostic and economic aspects of chlamydia screening in non-genitourinary medicine settings. METHODS: Linked studies around a cross-sectional population-based survey of adult men and women invited to collect urine and (for women) vulvovaginal swab specimens at home and mail these to a laboratory for testing for Chlamydia trachomatis. Specimens were used in laboratory evaluations of an amplified enzyme immunoassay (PCE EIA) and two nucleic acid amplification tests [Cobas polymerase chain reaction (PCR), Becton Dickinson strand displacement amplification (SDA)]. Chlamydia-positive cases and two negative controls completed a risk factor questionnaire. Chlamydia-positive cases were invited into a randomised controlled trial of partner notification strategies. Samples of individuals testing negative completed psychological questionnaires before and after screening. In-depth interviews were conducted at all stages of screening. Chlamydia transmission and cost-effectiveness of screening were investigated in a transmission dynamic model. SETTING AND PARTICIPANTS: General population in the Bristol and Birmingham areas of England. In total, 19,773 women and men aged 16-39 years were randomly selected from 27 general practice lists. RESULTS: Screening invitations reached 73% (14,382/19,773). Uptake (4731 participants), weighted for sampling, was 39.5% (95% CI 37.7, 40.8%) in women and 29.5% (95% CI 28.0, 31.0%) in men aged 16-39 years. Chlamydia prevalence (219 positive results) in 16-24 year olds was 6.2% (95% CI 4.9, 7.8%) in women and 5.3% (95% CI 4.4, 6.3%) in men. The case-control study did not identify any additional factors that would help target screening. Screening did not adversely affect anxiety, depression or self-esteem. Participants welcomed the convenience and privacy of home-sampling. The relative sensitivity of PCR on male urine specimens was 100% (95% CI 89.1, 100%). The combined relative sensitivities of PCR and SDA using female urine and vulvovaginal swabs were 91.8% (86.1, 95.7, 134/146) and 97.3% (93.1, 99.2%, 142/146). A total of 140 people (74% of eligible) participated in the randomised trial. Compared with referral to a genitourinary medicine clinic, partner notification by practice nurses resulted in 12.4% (95% CI -3.7, 28.6%) more patients with at least one partner treated and 22.0% (95% CI 6.1, 37.8%) more patients with all partners treated. The health service and patients costs (2005 prices) of home-based postal chlamydia screening were 21.47 pounds (95% CI 19.91 pounds, 25.99) per screening invitation and 28.56 pounds (95% CI 22.10 pounds, 30.43) per accepted offer. Preliminary modelling found an incremental cost-effectiveness ratio (2003 prices) comparing screening men and women annually to no screening in the base case of 27,000 pounds/major outcome averted at 8 years. If estimated screening uptake and pelvic inflammatory disease incidence were increased, the cost-effectiveness ratio fell to 3700 pounds/major outcome averted. CONCLUSIONS: Proactive screening for chlamydia in women and men using home-collected specimens was feasible and acceptable. Chlamydia prevalence rates in men and women in the general population are similar. Nucleic acid amplification tests can be used on first-catch urine specimens and vulvovaginal swabs. The administrative costs of proactive screening were similar to those for opportunistic screening. Using empirical estimates of screening uptake and incidence of complications, screening was not cost-effective.
Resumo:
The objectives of this study were to develop and validate a tool for assessing pain in population-based observational studies and to develop three subscales for back/neck, upper extremity and lower extremity pain. Based on a literature review, items were extracted from validated questionnaires and reviewed by an expert panel. The initial questionnaire consisted of a pain manikin and 34 items relating to (i) intensity of pain in different body regions (7 items), (ii) pain during activities of daily living (18 items) and (iii) various pain modalities (9 items). Psychometric validation of the initial questionnaire was performed in a random sample of the German-speaking Swiss population. Analyses included tests for reliability, correlation analysis, principal components factor analysis, tests for internal consistency and validity. Overall, 16,634 of 23,763 eligible individuals participated (70%). Test-retest reliability coefficients ranged from 0.32 to 0.97, but only three coefficients were below 0.60. Subscales were constructed combining four items for each of the subscales. Item-total coefficients ranged from 0.76 to 0.86 and Cronbach's alpha were 0.75 or higher for all subscales. Correlation coefficients between subscales and three validated instruments (WOMAC, SPADI and Oswestry) ranged from 0.62 to 0.79. The final Pain Standard Evaluation Questionnaire (SEQ Pain) included 28 items and the pain manikin and accounted for the multidimensionality of pain by assessing pain location and intensity, pain during activity, triggers and time of onset of pain and frequency of pain medication. It was found to be reliable and valid for the assessment of pain in population-based observational studies.
Resumo:
BACKGROUND: The aim of this study was to investigate the biochemical properties, histological and immunohistochemical appearance, and magnetic resonance (MR) imaging findings of reparative cartilage after autologous chondrocyte implantation (ACI) for osteochondritis dissecans (OCD). METHODS: Six patients (mean age 20.2 +/- 8.8 years; 13-35 years) who underwent ACI for full-thickness cartilage defects of the femoral condyle were studied. One year after the procedure, a second-look arthroscopic operation was performed with biopsy of reparative tissue. The International Cartilage Repair Society (ICRS) visual histological assessment scale was used for histological assessment. Biopsied tissue was immunohistochemically analyzed with the use of monoclonal antihuman collagen type I and monoclonal antihuman collagen type II primary antibodies. Glycosaminoglycan (GAG) concentrations in biopsied reparative cartilage samples were measured by high performance liquid chromatography (HPLC). MR imaging was performed with T1- and T2-weighted imaging and three-dimensional spoiled gradient-recalled (3D-SPGR) MR imaging. RESULTS: Four tissue samples were graded as having a mixed morphology of hyaline and fibrocartilage while the other two were graded as fibrocartilage. Average ICRS scores for each criterion were (I) 1.0 +/- 1.5; (II) 1.7 +/- 0.5; (III) 0.6 +/- 1.0; (IV) 3.0 +/- 0.0; (V) 1.8 +/- 1.5; and (VI) 2.5 +/- 1.2. Average total score was 10.7 +/- 2.8. On immunohistochemical analysis, the matrix from deep and middle layers of reparative cartilage stained positive for type II collagen; however, the surface layer did not stain well. The average GAG concentration in reparative cartilage was 76.6 +/- 4.2 microg/mg whereas that in normal cartilage was 108 +/- 11.2 microg/mg. Common complications observed on 3D-SPGR MR imaging were hypertrophy of grafted periosteum, edema-like signal in bone marrow, and incomplete repair of subchondral bone at the surgical site. Clinically, patients had significant improvements in Lysholm scores. CONCLUSIONS: In spite of a good clinical course, reparative cartilage after ACI had less GAG concentration and was inferior to healthy hyaline cartilage in histological and immunohistochemical appearance and on MRI findings.
Resumo:
BACKGROUND While the assessment of analytical precision within medical laboratories has received much attention in scientific enquiry, the degree of as well as the sources causing variation between them remains incompletely understood. In this study, we quantified the variance components when performing coagulation tests with identical analytical platforms in different laboratories and computed intraclass correlations coefficients (ICC) for each coagulation test. METHODS Data from eight laboratories measuring fibrinogen twice in twenty healthy subjects with one out of 3 different platforms and single measurements of prothrombin time (PT), and coagulation factors II, V, VII, VIII, IX, X, XI and XIII were analysed. By platform, the variance components of (i) the subjects, (ii) the laboratory and the technician and (iii) the total variance were obtained for fibrinogen as well as (i) and (iii) for the remaining factors using ANOVA. RESULTS The variability for fibrinogen measurements within a laboratory ranged from 0.02 to 0.04, the variability between laboratories ranged from 0.006 to 0.097. The ICC for fibrinogen ranged from 0.37 to 0.66 and from 0.19 to 0.80 for PT between the platforms. For the remaining factors the ICC's ranged from 0.04 (FII) to 0.93 (FVIII). CONCLUSIONS Variance components that could be attributed to technicians or laboratory procedures were substantial, led to disappointingly low intraclass correlation coefficients for several factors and were pronounced for some of the platforms. Our findings call for sustained efforts to raise the level of standardization of structures and procedures involved in the quantification of coagulation factors.
Resumo:
Rehabilitation robots have become important tools in stroke rehabilitation. Compared to manual arm training, robot-supported training can be more intensive, of longer duration and more repetitive. Therefore, robots have the potential to improve the rehabilitation process in stroke patients. Whereas a majority of previous work in upper limb rehabilitation robotics has focused on end-effector-based robots, a shift towards exoskeleton robots is taking place because they offer a better guidance of the human arm, especially for movements with a large range of motion. However, the implementation of an exoskeleton device introduces the challenge of reproducing the motion of the human shoulder, which is one of the most complex joints of the body. Thus, this paper starts with describing a simplified model of the human shoulder. On the basis of that model, a new ergonomic shoulder actuation principle that provides motion of the humerus head is proposed, and its implementation in the ARMin III arm therapy robot is described. The focus lies on the mechanics and actuation principle. The ARMin III robot provides three actuated degrees of freedom for the shoulder and one for the elbow joint. An additional module provides actuated lower arm pro/supination and wrist flexion/extension. Five ARMin III devices have been manufactured and they are currently undergoing clinical evaluation in hospitals in Switzerland and in the United States.
Resumo:
BACKGROUND Aortic dissection is a severe pathological condition in which blood penetrates between layers of the aortic wall and creates a duplicate channel - the false lumen. This considerable change on the aortic morphology alters hemodynamic features dramatically and, in the case of rupture, induces markedly high rates of morbidity and mortality. METHODS In this study, we establish a patient-specific computational model and simulate the pulsatile blood flow within the dissected aorta. The k-ω SST turbulence model is employed to represent the flow and finite volume method is applied for numerical solutions. Our emphasis is on flow exchange between true and false lumen during the cardiac cycle and on quantifying the flow across specific passages. Loading distributions including pressure and wall shear stress have also been investigated and results of direct simulations are compared with solutions employing appropriate turbulence models. RESULTS Our results indicate that (i) high velocities occur at the periphery of the entries; (ii) for the case studied, approximately 40% of the blood flow passes the false lumen during a heartbeat cycle; (iii) higher pressures are found at the outer wall of the dissection, which may induce further dilation of the pseudo-lumen; (iv) highest wall shear stresses occur around the entries, perhaps indicating the vulnerability of this region to further splitting; and (v) laminar simulations with adequately fine mesh resolutions, especially refined near the walls, can capture similar flow patterns to the (coarser mesh) turbulent results, although the absolute magnitudes computed are in general smaller. CONCLUSIONS The patient-specific model of aortic dissection provides detailed flow information of blood transport within the true and false lumen and quantifies the loading distributions over the aorta and dissection walls. This contributes to evaluating potential thrombotic behavior in the false lumen and is pivotal in guiding endovascular intervention. Moreover, as a computational study, mesh requirements to successfully evaluate the hemodynamic parameters have been proposed.
Resumo:
The performance of high-resolution CZE for determination of carbohydrate-deficient transferrin (CDT) in human serum based on internal and external quality data gathered over a 10-year period is reported. The assay comprises mixing of serum with a Fe(III) ion-containing solution prior to analysis of the iron saturated mixture in a dynamically double-coated capillary using a commercial buffer at alkaline pH. CDT values obtained with a human serum of a healthy individual and commercial quality control sera are shown to vary less than 10%. Values of a control from a specific lot were found to slowly decrease as function of time (less than 10% per year). Furthermore, due to unknown reasons, gradual changes in the monitored pattern around pentasialo-transferrin were detected, which limit the use of commercial control sera of the same lot to less than 2 years. Analysis of external quality control sera revealed correct classification of the samples over the entire 10-year period. Data obtained compare well with those of HPLC and CZE assays of other laboratories. The data gathered over a 10-year period demonstrate the robustness of the high-resolution CZE assay. This is the first account of a CZE-based CDT assay with complete internal and external quality assessment over an extended time period.
Resumo:
OBJECTIVE To compare isoflurane alone or in combination with systemic ketamine and lidocaine for general anaesthesia in horses. STUDY DESIGN Prospective, randomized, blinded clinical trial. ANIMALS Forty horses (ASA I-III) undergoing elective surgery. METHODS Horses were assigned to receive isoflurane anaesthesia alone (ISO) or with ketamine and lidocaine (LKI). After receiving romifidine, diazepam, and ketamine, the isoflurane end-tidal concentration was set at 1.3% and subsequently adjusted by the anaesthetist (unaware of treatments) to maintain a light plane of surgical anaesthesia. Animals in the LKI group received lidocaine (1.5 mg kg(-1) over 10 minutes, followed by 40 microg kg(-1) minute(-1)) and ketamine (60 microg kg(-1) minute(-1)), both reduced to 65% of the initial dose after 50 minutes, and stopped 15 minutes before the end of anaesthesia. Standard clinical cardiovascular and respiratory parameters were monitored. Recovery quality was scored from one (very good) to five (very poor). Differences between ISO and LKI groups were analysed with a two-sample t-test for parametric data or a Fischer's exact test for proportions (p < 0.05 for significance). Results are mean +/- SD. RESULTS Heart rate was lower (p = 0.001) for LKI (29 +/- 4) than for ISO (34 +/- 6). End-tidal concentrations of isoflurane (ISO: 1.57% +/- 0.22; LKI: 0.97% +/- 0.33), the number of horses requiring thiopental (ISO: 10; LKI: 2) or dobutamine (ISO:8; LKI:3), and dobutamine infusion rates (ISO:0.26 +/- 0.09; LKI:0.18 +/- 0.06 microg kg(-1) minute(-1)) were significantly lower in LKI compared to the ISO group (p < 0.001). No other significant differences were found, including recovery scores. CONCLUSIONS AND CLINICAL RELEVANCE These results support the use of lidocaine and ketamine to improve anaesthetic and cardiovascular stability during isoflurane anaesthesia lasting up to 2 hours in mechanically ventilated horses, with comparable quality of recovery.