240 resultados para INTRAOPERATIVE ULTRASOUND

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Carotid atherosclerotic disease is highly related to cerebrovascular events. Carotid endarterectomy is the common operation method to treat this disease. In this study, hemodynamics analyses are performed on the carotid arteries in three patients, whose right carotid artery had been treated by carotid endarterectomy and the left carotid artery remained untreated. Flow and loading conditions are compared between these treated and untreated carotid arteries and evaluation of the operative results is discussed. Patient-specific models are reconstructed from MDCT data. Intraoperative ultrasound flow measurements are performed on the treated carotid arteries and the obtained data are used as the boundary conditions of the models and the validations of the computational results. Finite volume method is employed to solve the transport equations and the flow and loading conditions of the models are reported. The results indicate that: (i) in two of the three patients, the internal-to-external flow rate ratio in the untreated carotid artery is larger than that in the treated one, and the average overall flow split ratio by summing up the data of both the left and right carotid arteries is about 2.15; (ii) in the carotid bulb, high wall shear stress occurs at the bifurcation near the external carotid artery in all of the cases without hard plaques; (iii) the operated arteries present low time-averaged wall shear stress at the carotid bulb, especially for the treated arteries with patch technique, indicating the possibility of the recurrence of stenosis; (iv) high temporal gradient of wall shear stress (>35 Pa/s) is shown in the narrowing regions along the vessels; and (v) in the carotid arteries without serious stenosis, the maximum velocity magnitude during mid-diastole is 32~37% of that at systolic peak, however, in the carotid artery with 50% stenosis by hard plaques, this value is nearly doubled (64%). The computational work quantifies flow and loading distributions in the treated and untreated carotid arteries of the same patient, contributing to evaluation of the operative results and indicating the recurrent sites of potential atheromatous plaques.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We present a case of an intraoperative acute aortic type A dissection (AADA) extending from the distal ascending aorta to the distal aortic arch, initially not visible on the transesophageal echocardiography (TEE). The rapid confirmation of the diagnosis by means of direct epiaortic ultrasound scanning facilitated decision-making and the subsequent successful surgical treatment.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECT: Ultrasound may be a reliable but simpler alternative to intraoperative MR imaging (iMR imaging) for tumor resection control. However, its reliability in the detection of tumor remnants has not been definitely proven. The aim of the study was to compare high-field iMR imaging (1.5 T) and high-resolution 2D ultrasound in terms of tumor resection control. METHODS: A prospective comparative study of 26 consecutive patients was performed. The following parameters were compared: the existence of tumor remnants after presumed radical removal and the quality of the images. Tumor remnants were categorized as: detectable with both imaging modalities or visible only with 1 modality. RESULTS: Tumor remnants were detected in 21 cases (80.8%) with iMR imaging. All large remnants were demonstrated with both modalities, and their image quality was good. Two-dimensional ultrasound was not as effective in detecting remnants<1 cm. Two remnants detected with iMR imaging were missed by ultrasound. In 2 cases suspicious signals visible only on ultrasound images were misinterpreted as remnants but turned out to be a blood clot and peritumoral parenchyma. The average time for acquisition of an ultrasound image was 2 minutes, whereas that for an iMR image was approximately 10 minutes. Neither modality resulted in any procedure-related complications or morbidity. CONCLUSIONS: Intraoperative MR imaging is more precise in detecting small tumor remnants than 2D ultrasound. Nevertheless, the latter may be used as a less expensive and less time-consuming alternative that provides almost real-time feedback information. Its accuracy is highest in case of more confined, deeply located remnants. In cases of more superficially located remnants, its role is more limited.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Computer-aided surgery (CAS) allows for real-time intraoperative feedback resulting in increased accuracy, while reducing intraoperative radiation. CAS is especially useful for the treatment of certain pelvic ring fractures, which necessitate the precise placement of screws. Flouroscopy-based CAS modules have been developed for many orthopedic applications. The integration of the isocentric flouroscope even enables navigation using intraoperatively acquired three-dimensional (3D) data, though the scan volume and imaging quality are limited. Complicated and comprehensive pathologies in regions like the pelvis can necessitate a CT-based navigation system because of its larger field of view. To be accurate, the patient's anatomy must be registered and matched with the virtual object (CT data). The actual precision within the region of interest depends on the area of the bone where surface matching is performed. Conventional surface matching with a solid pointer requires extensive soft tissue dissection. This contradicts the primary purpose of CAS as a minimally invasive alternative to conventional surgical techniques. We therefore integrated an a-mode ultrasound pointer into the process of surface matching for pelvic surgery and compared it to the conventional method. Accuracy measurements were made in two pelvic models: a foam model submerged in water and one with attached porcine muscle tissue. Three different tissue depths were selected based on CT scans of 30 human pelves. The ultrasound pointer allowed for registration of virtually any point on the pelvis. This method of surface matching could be successfully integrated into CAS of the pelvis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: Congenital uterine anomalies often remain asymptomatic until they cause problems, for example during pregnancy. We studied the diagnostic aspects of two- and three-dimensional ultrasound and MRI. Materials and Methods: 63 women referred for suspected uterine anomalies were studied: In the first group (until July 2008) with 2 D-US and MRI, in the second group (from August 2008) additionally with 3 D-US; these women also had diagnostic or therapeutic operative confirmation. In the third group, only 3D-US was used. Results: In all women 3D-US was possible and successful. The most common anomaly was a subseptate uterus, while a septate uterus was less frequent, and uterus bicornis (unicollis) and uterus didelphys (bicornis bicollis) were rare. The women in the first two groups all underwent at least diagnostic hysteroscopy, and some (subseptate or septate uterus) underwent operative hysteroscopy. After preoperative volume imaging, laparoscopies were required less often. 3D-US diagnoses as judged by intraoperative findings were correct in 100 % of cases, while the MRI diagnoses in the same group were correct in only 7/13 cases. Conclusion: Since the introduction of volume imaging (MRI, later 3 D-US), laparoscopy during hysteroscopic septum resection was not necessary in the majority of cases. 3D-US brings the diagnostics of uterine anomalies back into the hands of the gynecologist and can provide the gynecological surgeon with a higher subjective degree of certainty during operative hysteroscopy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ultrasound contrast agents are gas-filled microbubbles that enhance visualization of cardiac structures, function and blood flow during contrast-enhanced ultrasound (CEUS). An interesting cardiovascular application of CEUS is myocardial contrast echocardiography, which allows real-time myocardial perfusion imaging. The intraoperative use of this technically challenging imaging method is limited at present, although several studies have examined its clinical utility during cardiac surgery in the past. In the present review we provide general information on the basic principles of CEUS and discuss the methodology and technical aspects of myocardial perfusion imaging.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Patient-to-image registration is a core process of image-guided surgery (IGS) systems. We present a novel registration approach for application in laparoscopic liver surgery, which reconstructs in real time an intraoperative volume of the underlying intrahepatic vessels through an ultrasound (US) sweep process. METHODS An existing IGS system for an open liver procedure was adapted, with suitable instrument tracking for laparoscopic equipment. Registration accuracy was evaluated on a realistic phantom by computing the target registration error (TRE) for 5 intrahepatic tumors. The registration work flow was evaluated by computing the time required for performing the registration. Additionally, a scheme for intraoperative accuracy assessment by visual overlay of the US image with preoperative image data was evaluated. RESULTS The proposed registration method achieved an average TRE of 7.2 mm in the left lobe and 9.7 mm in the right lobe. The average time required for performing the registration was 12 minutes. A positive correlation was found between the intraoperative accuracy assessment and the obtained TREs. CONCLUSIONS The registration accuracy of the proposed method is adequate for laparoscopic intrahepatic tumor targeting. The presented approach is feasible and fast and may, therefore, not be disruptive to the current surgical work flow.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The thoracoscopic pleurodesis with talc is an established therapy in case of malignant pleural effusion. With the instillation of talc a -localised inflammation is induced. However, some-times it turns into a severe systemic reaction. In this study of the postoperative course, the -question is examined whether a pleural biopsy is an additional risk factor for morbidity and mortality after talc pleurodesis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sonography is an established diagnostic procedure in hospitals, but is not routinely used in prehospital emergency medicine. Several studies have addressed the use of ultrasound during helicopter flights and in emergency rooms, few in prehospital settings, but most focused on abdominal blunt trauma. Several case reports describe crucial decisions distinguished by ultrasound.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cardiac papillary fibroelastoma is a benign tumor that mainly affects cardiac valves. The tumor has the potential to cause angina and myocardial infarction due to embolization of tumor fragments. We describe a rare case of right coronary artery ostial obstruction by a 12 x 19 mm sized papillary fibroelastoma located in the sinus of Valsalva. The report underlies the importance of echocardiography in diagnosis and intraoperative treatment of this type of cardiac mass.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Paravertebral regional anaesthesia is used to treat pain after several surgical procedures. This study aimed to improve on our first published ultrasound-guided approach to the paravertebral space (PVS) and to investigate a possible discrepancy between the needle, catheter, and contrast dye position.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Performing spermatic cord block for scrotal surgery avoids the potential risks of neuraxial and general anaesthesia and provides long-lasting postoperative analgesia. A blindly performed block is often inefficient and bears its own potential risks (intravascular injection of local anaesthetics, haematoma formation and perforation of the deferent duct). The use of ultrasound may help to overcome these disadvantages. The aim of this study was to test the feasibility and monitor the success rate of a new ultrasound-guided spermatic cord block.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Local anaesthetic blocks of the greater occipital nerve (GON) are frequently performed in different types of headache, but no selective approaches exist. Our cadaver study compares the sonographic visibility of the nerve and the accuracy and specificity of ultrasound-guided injections at two different sites. METHODS: After sonographic measurements in 10 embalmed cadavers, 20 ultrasound-guided injections of the GON were performed with 0.1 ml of dye at the classical site (superior nuchal line) followed by 20 at a newly described site more proximal (C2, superficial to the obliquus capitis inferior muscle). The spread of dye and coloration of nerve were evaluated by dissection. RESULTS: The median sonographic diameter of the GON was 4.2 x 1.4 mm at the classical and 4.0 x 1.8 mm at the new site. The nerves were found at a median depth of 8 and 17.5 mm, respectively. In 16 of 20 in the classical approach and 20 of 20 in the new approach, the nerve was successfully coloured with the dye. This corresponds to a block success rate of 80% (95% confidence interval: 58-93%) vs 100% (95% confidence interval: 86-100%), which is statistically significant (McNemar's test, P=0.002). CONCLUSIONS: Our findings confirm that the GON can be visualized using ultrasound both at the level of the superior nuchal line and C2. This newly described approach superficial to the obliquus capitis inferior muscle has a higher success rate and should allow a more precise blockade of the nerve.