15 resultados para Frequency dependence parameters

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

80.00% 80.00%

Publicador:

Resumo:

In patients with drug-resistant hypertension, chronic electric stimulation of the carotid baroreflex is an investigational therapy for blood pressure reduction. We hypothesized that changes in cardiac autonomic regulation can be demonstrated in response to chronic baroreceptor stimulation, and we analyzed the correlation with blood pressure changes. Twenty-one patients with drug-resistant hypertension were prospectively included in a substudy of the Device Based Therapy in Hypertension Trial. Heart rate variability and heart rate turbulence were analyzed using 24-hour ECG. Recordings were obtained 1 month after device implantation with the stimulator off and after 3 months of chronic electric stimulation (stimulator on). Chronic baroreceptor stimulation decreased office blood pressure from 185+/-31/109+/-24 mm Hg to 154+/-23/95+/-16 mm Hg (P<0.0001/P=0.002). Mean heart rate decreased from 81+/-11 to 76+/-10 beats per minute(-1) (P=0.001). Heart rate variability frequency-domain parameters assessed using fast Fourier transformation (FFT; ratio of low frequency:high frequency: 2.78 versus 2.24 for off versus on; P<0.001) were significantly changed during stimulation of the carotid baroreceptor, and heart rate turbulence onset was significantly decreased (turbulence onset: -0.002 versus -0.015 for off versus on; P=0.004). In conclusion, chronic baroreceptor stimulation causes sustained changes in heart rate variability and heart rate turbulence that are consistent with inhibition of sympathetic activity and increase of parasympathetic activity in patients with drug-resistant systemic hypertension; these changes correlate with blood pressure reduction. Whether the autonomic modulation has favorable cardiovascular effects beyond blood pressure control should be investigated in further studies.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Respiratory system input impedance (Zrs) at low to medium frequencies below 100 Hz, and study of its volume dependence, have been used extensively to quantify airway and tissue mechanics. Zrs at high oscillation frequencies including the first antiresonant frequency (far,1) may contain important information about airway mechanics. Changes in high-frequency Zrs with lung volume have not been studied. The volume-dependent behavior of high-frequency Zrs, specifically far,1 and respiratory system resistance at first antiresonance (Rrs(far,1)), was characterized in 16 healthy adults. Zrs was measured with a forced oscillation signal (5-302.5 Hz) through a wavetube setup. To track Zrs, subjects performed slow deep inspiratory and expiratory maneuvers over 30-s measurements, during which average impedance was calculated over 0.4-s intervals, with successive overlapping estimates every 0.156 s. Flow was measured using a pneumotachometer and integrated to obtain volume. Transpulmonary pressure dependence (Ptp) of Zrs was separately determined in five subjects. Both far,1 and Rrs(far,1) decreased with increasing lung volume and Ptp, consistent with an increase in airway caliber and decreased airway wall compliance as volume increased. These characterizations provide insight into airway mechanics, and are furthermore a necessary first step toward determining whether volume dependence of the first antiresonance is altered in disease.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The available results of deep imaging searches for planetary companions around nearby stars provide us useful constraints on the frequencies of giant planets in very wide orbits. Here we present some preliminary results of the Monte Carlo simulation which compare the published detection limits with the generated planetary masses and orbital parameters. This allow us to consider the impications of the null detection, which comes from the direct imaging techniques, on the distributions of mass and semimajor axis derived from the results of the other search techniques and also to check the agreement of the observations with the available planetary formation models.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The pain and distress associated with transcutaneous electrical nerve stimulation (TENS) of the udder was evaluated by treating 20 healthy dairy cows with an electrical udder stimulator. This generated a sequence of pulses (frequency: 160+/-10% impulses per second, duration 250 mus) and provided voltage ranges from 0 to 10 volts (+/-10%). Trials took place on three consecutive days, twice daily after morning and evening milking. Daily sessions were divided into two periods: (1) control (sham treatment) and (2) treatment (real treatment). Physiological (heart rate, respiratory rate, and plasma cortisol concentration) as well as ethological parameters (kicking, weight shifting, and looking backwards to udder) were defined as pain-indicating parameters and observed. Evaluation of data showed that only one parameter (kicking) was significantly increased during real treatment compared to sham treatment. It is concluded that the TENS therapy tested in this study can evoke changes in behaviour (increased kicking) consistent with an experience of pain in some cows.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Time domain analysis of electroencephalography (EEG) can identify subsecond periods of quasi-stable brain states. These so-called microstates assumingly correspond to basic units of cognition and emotion. On the other hand, Global Field Synchronization (GFS) is a frequency domain measure to estimate functional synchronization of brain processes on a global level for each EEG frequency band [Koenig, T., Lehmann, D., Saito, N., Kuginuki, T., Kinoshita, T., Koukkou, M., 2001. Decreased functional connectivity of EEG theta-frequency activity in first-episode, neuroleptic-naive patients with schizophrenia: preliminary results. Schizophr Res. 50, 55-60.]. Using these time and frequency domain analyzes, several previous studies reported shortened microstate duration in specific microstate classes and decreased GFS in theta band in drug naïve schizophrenia compared to controls. The purpose of this study was to investigate changes of these EEG parameters after drug treatment in drug naïve schizophrenia. EEG analysis was performed in 21 drug-naive patients and 21 healthy controls. 14 patients were reevaluated 2-8 weeks (mean 4.3) after the initiation of drug administration. The results extended findings of treatment effect on brain functions in schizophrenia, and imply that shortened duration of specific microstate classes seems a state marker especially in patients with later neuroleptic responsive, while lower theta GFS seems a state-related phenomenon and that higher gamma GFS is a trait like phenomenon.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Resonance frequency analysis (RFA) is a method of measuring implant stability. However, little is known about RFA of implants with long loading periods. The objective of the present study was to determine standard implant stability quotients (ISQs) for clinical successfully osseointegrated 1-stage implants in the edentulous mandible. MATERIALS AND METHODS: Stability measurements by means of RFA were performed in regularly followed patients who had received 1- stage implants for overdenture support. The time interval between implant placement and measurement ranged from 1 year up to 10 years. The short-term group comprised patients who were followed up to 5 years, while the long-term group included patients with an observation time of > 5 years up to 10 years. For further comparison RFA measurements were performed in a matching group with unloaded implants at the end of the surgical procedure. For statistical analysis various parameters that might influence the ISQs of loaded implants were included, and a mixed-effects model applied (regression analysis, P <.0125). RESULTS: Ninety-four patients were available with a total of 205 loaded implants, and 16 patients with 36 implants immediately after the surgical procedure. The mean ISQ of all measured implants was 64.5 +/- 7.9 (range, 58 to 72). Statistical analysis did not reveal significant differences in the mean ISQ related to the observation time. The parameters with overall statistical significance were the diameter of the implants and changes in the attachment level. In the short-term group, the gender and the clinically measured attachment level had a significant effect. Implant diameter had a significant effect in the long-term group. CONCLUSIONS: A mean ISQ of 64.5 +/- 7.9 was found to be representative for stable asymptomatic interforaminal implants measured by the RFA instrument at any given time point. No significant differences in ISQ values were found between implants with different postsurgical time intervals. Implant diameter appears to influence the ISQ of interforaminal implants.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To prospectively quantify in vitro the influence of gadopentetate dimeglumine and ioversol on the magnetic resonance (MR) imaging signal observed with a variety of musculoskeletal pulse sequences to predict optimum gadolinium concentrations for direct MR arthrography at 1.5 and 3.0 T. MATERIALS AND METHODS: In an in vitro study, T1 and T2 relaxation times of three dilution series of gadopentetate dimeglumine (concentration, 0-20.0 mmol gadolinium per liter) at ioversol concentrations with iodine concentration of 0, 236.4, and 1182 mmol iodine per liter (corresponding to 0, 30, and 150 mg of iodine per milliliter) were measured at 1.5 and 3.0 T. The relaxation rate dependence on concentrations of gadolinium and iodine was analytically modeled, and continuous profiles of signal versus gadolinium concentration were calculated for 10 pulse sequences used in current musculoskeletal imaging. After fitting to experimental discrete profiles, maximum signal-to-noise ratio (SNR), gadolinium concentration with maximum SNR, and range of gadolinium concentration with 90% of maximum SNR were derived. The overall influence of field strength and iodine concentration on these parameters was assessed by using t tests. The deviation of simulated from experimental signal-response profiles was assessed with the autocorrelation of the residuals. RESULTS: The model reproduced relaxation rates of 0.37-38.24 sec(-1), with a mean error of 4.5%. Calculated SNR profiles matched the discrete experimental profiles, with autocorrelation of the residuals divided by the mean of less than 5.0. Admixture of ioversol consistently reduced T1 and T2, narrowed optimum gadolinium concentration ranges (P = .004-.006), and reduced maximum SNR (P < .001 to not significant). Optimum gadolinium concentration was 0.7-3.4 mmol/L at both field strengths. At 3.0 T, maximum SNR was up to 75% higher than at 1.5 T. CONCLUSION: Admixture of ioversol to gadopentetate dimeglumine solutions results in a consistent additional relaxation enhancement, which can be analytically modeled to allow a near-quantitative a priori optimized match of contrast media concentrations and imaging protocol for a broad variety of pulse sequences.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: Resonance frequency analysis (RFA) offers the opportunity to monitor the osseointegration of an implant in a simple, noninvasive way. A better comprehension of the relationship between RFA and parameters related to bone quality would therefore help clinicians improve diagnoses. In this study, a bone analog made from polyurethane foam was used to isolate the influences of bone density and cortical thickness in RFA. MATERIALS AND METHODS: Straumann standard implants were inserted in polyurethane foam blocks, and primary implant stability was measured with RFA. The blocks were composed of two superimposed layers with different densities. The top layer was dense to mimic cortical bone, whereas the bottom layer had a lower density to represent trabecular bone. Different densities for both layers and different thicknesses for the simulated cortical layer were tested, resulting in eight different block combinations. RFA was compared with two other mechanical evaluations of primary stability: removal torque and axial loading response. RESULTS: The primary stability measured with RFA did not correlate with the two other methods, but there was a significant correlation between removal torque and the axial loading response (P < .005). Statistical analysis revealed that each method was sensitive to different aspects of bone quality. RFA was the only method able to detect changes in both bone density and cortical thickness. However, changes in trabecular bone density were easier to distinguish with removal torque and axial loading than with RFA. CONCLUSIONS: This study shows that RFA, removal torque, and axial loading are sensitive to different aspects of the bone-implant interface. This explains the absence of correlation among the methods and proves that no standard procedure exists for the evaluation of primary stability.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Repetitive transcranial magnetic stimulation (rTMS) is a novel research tool in neurology and psychiatry. It is currently being evaluated as a conceivable alternative to electroconvulsive therapy for the treatment of mood disorders. Eight healthy young (age range 21-25 years) right-handed men without sleep complaints participated in the study. Two sessions at a 1-week interval, each consisting of an adaptation night (sham stimulation) and an experimental night (rTMS in the left dorsolateral prefrontal cortex or sham stimulation; crossover design), were scheduled. In each subject, 40 trains of 2-s duration of rTMS (inter-train interval 28 s) were applied at a frequency of 20 Hz (i.e. 1600 pulses per session) and at an intensity of 90% of the motor threshold. Stimulations were scheduled 80 min before lights off. The waking EEG was recorded for 10-min intervals approximately 30 min prior to and after the 20-min stimulations, and polysomnographic recordings were obtained during the subsequent sleep episode (23.00-07.00 h). The power spectra of two referential derivations, as well as of bipolar derivations along the antero-posterior axis over the left and right hemispheres, were analyzed. rTMS induced a small reduction of sleep stage 1 (in min and percentage of total sleep time) over the whole night and a small enhancement of sleep stage 4 during the first non-REM sleep episode. Other sleep variables were not affected. rTMS of the left dorsolateral cortex did not alter the topography of EEG power spectra in waking following stimulation, in the all-night sleep EEG, or during the first non-REM sleep episode. Our results indicate that a single session of rTMS using parameters like those used in depression treatment protocols has no detectable side effects with respect to sleep in young healthy males.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We demonstrate the creation, characterization, and manipulation of frequency-entangled qudits by shaping the energy spectrum of entangled photons. The generation of maximally entangled qudit states is verified up to dimension d=4 through tomographic quantum-state reconstruction. Subsequently, we measure Bell parameters for qubits and qutrits as a function of their degree of entanglement. In agreement with theoretical predictions, we observe that for qutrits the Bell parameter is less sensitive to a varying degree of entanglement than for qubits. For frequency-entangled photons, the dimensionality of a qudit is ultimately limited by the bandwidth of the pump laser and can be on the order of a few millions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Home dream recall frequencies and nightmare frequencies show great inter-individual differences. Most of the studies trying to explain these differences, however, studied young participants, so these findings might not be true for persons older than 25 years. The present study investigated the relationship between dream recall, nightmare frequency, age, gender, sleep parameters, stress, and subjective health in a community-based sample (N = 455) with a mean age of about 55 years. Some of the factors that have been shown to be associated with dream recall and nightmare frequency were also associated with these variables in non-student sample like frequency of nocturnal awakenings, current stress, and tiredness during the day. We were not able to replicate the effect of sex-role orientation on dream recall and nightmare frequency, supporting the idea that age might mediate the effect of daytime variables on dream recall and nightmare frequency. As nightmare frequency was related to sleep quality, stress, health problems, and tiredness during the day, it would be desirable that clinicians include a question about nightmares in their anamneses.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE To analyze the frequency of perforation of the sinus membrane during maxillary sinus floor elevation (SFE) and to assess possible risk factors. MATERIALS AND METHODS Seventy-seven cases of SFE performed with a lateral window approach were evaluated retrospectively. Clinical and radiographic variables potentially influencing the risk of sinus membrane perforation were evaluated and divided into patient-related factors (age, sex, smoking habit); surgery-related factors (type of surgical approach, side, units, sites, and technique of osteotomy); and maxillary sinus-related factors (presence and height of septum, height of residual ridge, thickness of lateral sinus wall, width of antrum, and thickness and status of sinus membrane). RESULTS The following factors presented with at least a 10% difference in rates of perforations: smokers (46.2%) versus nonsmokers (23.4%), simultaneous (32%) versus staged (18.5%) approach, mixed premolar-molar sites (41.2%) versus premolar-only sites (16.7%) versus molar-only sites (26.2%), presence of septa (42.9%) versus no septa (23.8%), and minimum height of residual ridge ≤4 mm (34.2%) versus > 4 mm (20.5%). These same parameters, except minimum height of residual ridge, also showed an odds ratio above 2. However, none of the comparisons reached statistical significance. CONCLUSION The present study failed to demonstrate any factor that statistically significantly increased the risk of sinus membrane perforation during SFE using the lateral window approach.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

ntroduction: The ProAct study has shown that a pump switch to the Accu-Chek® Combo system (Roche Diagnostics Deutschland GmbH, Mannheim, Germany) in type 1 diabetes patients results in stable glycemic control with significant improvements in glycated hemoglobin (HbA1c) in patients with unsatisfactory baseline HbA1c and shorter pump usage time. Patients and Methods: In this post hoc analysis of the ProAct database, we investigated the glycemic control and glycemic variability at baseline by determination of several established parameters and scores (HbA1c, hypoglycemia frequency, J-score, Hypoglycemia and Hyperglycemia Indexes, and Index of Glycemic Control) in participants with different daily bolus and blood glucose measurement frequencies (less than four day, four or five per day, and more than five per day, in both cases). The data were derived from up to 299 patients (172 females, 127 males; age [mean±SD], 39.4±15.2 years; pump treatment duration, 7.0±5.2 years). Results: Participants with frequent glucose readings had better glycemic control than those with few readings (more than five readings per day vs. less than four readings per day: HbA1c, 7.2±1.1% vs. 8.0±0.9%; mean daily blood glucose, 151±22 mg/dL vs. 176±30 mg/dL; percentage of readings per month >300 mg/dL, 10±4% vs. 14±5%; percentage of readings in target range [80-180 mg/dL], 59% vs. 48% [P<0.05 in all cases]) and had a lower glycemic variability (J-score, 49±13 vs. 71±25 [P<0.05]; Hyperglycemia Index, 0.9±0.5 vs. 1.9±1.2 [P<0.05]; Index of Glycemic Control, 1.9±0.8 vs. 3.1±1.6 [P<0.05]; Hypoglycemia Index, 0.9±0.8 vs. 1.2±1.3 [not significant]). Frequent self-monitoring of blood glucose was associated with a higher number of bolus applications (6.1±2.2 boluses/day vs. 4.5±2.0 boluses/day [P<0.05]). Therefore, a similar but less pronounced effect on glycemic variability in favor of more daily bolus applications was observed (more than five vs. less than four bolues per day: J-score, 57±17 vs. 63±25 [not significant]; Hypoglycemia Index, 1.0±1.0 vs. 1.5±1.4 [P<0.05]; Hyperglycemia Index, 1.3±0.6 vs. 1.6±1.1 [not significant]; Index of Glycemic Control, 2.3±1.1 vs. 3.1±1.7 [P<0.05]). Conclusions: Pump users who perform frequent daily glucose readings have a better glycemic control with lower glycemic variability.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The concentration of 11-nor-9-carboxy-Δ(9)-tetrahydrocannabinol (THCCOOH) in whole blood is used as a parameter for assessing the consumption behavior of cannabis consumers. The blood level of THCCOOH-glucuronide might provide additional information about the frequency of cannabis use. To verify this assumption, a column-switching liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the rapid and direct quantification of free and glucuronidated THCCOOH in human whole blood was newly developed. The method comprised protein precipitation, followed by injection of the processed sample onto a trapping column and subsequent gradient elution to an analytical column for separation and detection. The total LC run time was 4.5 min. Detection of the analytes was accomplished by electrospray ionization in positive ion mode and selected reaction monitoring using a triple-stage quadrupole mass spectrometer. The method was fully validated by evaluating the following parameters: linearity, lower limit of quantification, accuracy and imprecision, selectivity, extraction efficiency, matrix effect, carry-over, dilution integrity, analyte stability, and re-injection reproducibility. All acceptance criteria were analyzed and the predefined criteria met. Linearity ranged from 5.0 to 500 μg/L for both analytes. The method was successfully applied to whole blood samples from a large collective of cannabis consumers, demonstrating its applicability in the forensic field.