em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND Paediatric supraglottic airway devices AmbuAura-i and Air-Q were designed as conduits for tracheal intubation. Although fibreoptic-guided intubation has proved successful, blind intubation as a rescue technique has never been evaluated. OBJECTIVE Evaluation of blind intubation through AmbuAura-i and Air-Q. On the basis of fibreoptic view data, we hypothesised that the success rate with the AmbuAura-i would be higher than with the Air-Q. DESIGN A prospective, randomised controlled trial with institutional review board (IRB) approval and written informed consent. SETTING University Childrens' Hospital; September 2012 to July 2014. PATIENTS Eighty children, American Society of Anesthesiologists (ASA) class I to III, weight 5 to 50 kg. INTERVENTIONS Tracheal intubation was performed through the randomised device with the tip of a fibrescope placed inside and proximal to the tip of the tracheal tube. This permitted sight of tube advancement, but without fibreoptic guidance (visualised blind intubation). MAIN OUTCOME MEASURES Primary outcome was successfully visualised blind intubation; secondary outcomes included supraglottic airway device success, insertion times, airway leak pressure, fibreoptic view and adverse events. RESULTS Personal data did not differ between groups. In contrast to our hypothesis, blind intubation was possible in 15% with the Air-Q and in 3% with the AmbuAura-i [95% confidence interval (95% CI) 6 to 31 vs. 0 to 13%; P = 0.057]. First attempt supraglottic airway device insertion success rates were 95% (Air-Q) and 100% (AmbuAura-i; 95% CI 83 to 99 vs. 91 to 100; P = 0.49). Median leak pressures were 18 cmH2O (Air-Q) and 17 cmH2O [AmbuAura-i; interquartile range (IQR) 14 to 18 vs. 14 to 19 cmH2O; P = 0.66]. Air-Q insertion was slower (27 vs. 19 s, P < 0.001). There was no difference in fibreoptic view, or adverse events (P > 0.05). In one child (Air-Q size 1.5, tube size 3.5), the tube dislocated during device removal. CONCLUSION Ventilation with both devices is reliable, but success of blind intubation is unacceptably low and cannot be recommended for elective or rescue purposes. If intubation through a paediatric supraglottic airway device is desired, we suggest that fibreoptic guidance is used. TRIAL REGISTRATION Clinicaltrials.gov identifier: NCT01692522.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The use of self-expanding retrievable stents is an emerging and promising treatment strategy for acute stroke treatment. The concept combines the advantages of stent deployment with immediate flow-restoration and of mechanical thrombectomy with definitive thrombus removal. The present study was performed to gain more knowledge about the principle of combined flow restoration and thrombectomy in an established animal model using radiopaque thrombi evaluating efficiency, thrombus-device interaction and possible complications of the first dedicated flow-restoration and mechanical thrombectomy device.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: To determine the clinical performance of a laser fluorescence device (DIAGNOdent pen, KaVo) to discriminate between different occlusal caries depths (D(0)-D(1-4); D(0-2)-D(3,4)) in permanent molars. METHODS: In this prospective, randomized two-centre-study 120 sound/uncavitated carious sites in 120 patients were measured after visual and radiographic caries assessment. In cases of operative intervention (n=86), the lesion depths after caries removal were recorded (reference). In cases of preventive intervention (n=34), the sites were reassessed visually/radiographically after 12 months to verify the status assessed before (reference). The discrimination performance was determined statistically (Mann-Whitney test, Spearman's rho coefficient, and areas under the receiver operating characteristic curves (AUCs)). Sensitivities (SE) and specificities (SP) were plotted as a function of the measured values and cut-off values for the mentioned thresholds suggested. RESULTS: Sound sites (n=13) had significantly minor fluorescence values than carious sites (n=107) (P<0.0001) as had sites with no/enamel caries (n=63) compared to dentinal caries (n=57). The AUCs for the same discriminations were 0.92 and 0.78 (P<0.001). For the D(0)-D(1-4) threshold, a cut-off at a value of 12 (SE: 0.88, SP: 0.85) and for the D(0-2)-D(3,4) threshold at 25 (SE: 0.67, SP: 0.79) can be suggested. A moderate positive correlation between the measurements and the caries depths was calculated (rho=+0.57, P=0.01). CONCLUSION: Within this study, the device's discrimination performance for different caries depths was moderate to very good and it may be recommended as adjunct tool in the diagnosis of occlusal caries.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate fixation properties of a new intervertebral anchored fusion device and compare these with ventral locking plate fixation. STUDY DESIGN: In vitro biomechanical evaluation. ANIMALS: Cadaveric canine C4-C7 cervical spines (n = 9). METHODS: Cervical spines were nondestructively loaded with pure moments in a nonconstraining testing apparatus to induce flexion/extension while angular motion was measured. Range of motion (ROM) and neutral zone (NZ) were calculated for (1) intact specimens, (2) specimens after discectomy and fixation with a purpose-built intervertebral fusion cage with integrated ventral fixation, and (3) after removal of the device and fixation with a ventral locking plate. RESULTS: Both fixation techniques resulted in a decrease in ROM and NZ (P < .001) compared with the intact segments. There were no significant differences between the anchored spacer and locking plate fixation. CONCLUSION: An anchored spacer appears to provide similar biomechanical stability to that of locking plate fixation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We report the intraoperative courses of 2 consecutive Berlin Heart Excor® Pediatric Ventricular Assist Device implantations, in which transcranial Doppler ultrasonography helped to detect macroscopically undetected residual air bubbles captured in the pump after air removal had been correctly performed according to manufacturer's specifications. Our experience with these cases suggests that a beat-to beat deairing maneuver guided by transcranial Doppler is a useful strategy for reducing cerebral exposure to perioperative gaseous microembolism.