44 resultados para Continuous glucose monitoring

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract Background and Aims: Data on the influence of calibration on accuracy of continuous glucose monitoring (CGM) are scarce. The aim of the present study was to investigate whether the time point of calibration has an influence on sensor accuracy and whether this effect differs according to glycemic level. Subjects and Methods: Two CGM sensors were inserted simultaneously in the abdomen on either side of 20 individuals with type 1 diabetes. One sensor was calibrated predominantly using preprandial glucose (calibration(PRE)). The other sensor was calibrated predominantly using postprandial glucose (calibration(POST)). At minimum three additional glucose values per day were obtained for analysis of accuracy. Sensor readings were divided into four categories according to the glycemic range of the reference values (low, ≤4 mmol/L; euglycemic, 4.1-7 mmol/L; hyperglycemic I, 7.1-14 mmol/L; and hyperglycemic II, >14 mmol/L). Results: The overall mean±SEM absolute relative difference (MARD) between capillary reference values and sensor readings was 18.3±0.8% for calibration(PRE) and 21.9±1.2% for calibration(POST) (P<0.001). MARD according to glycemic range was 47.4±6.5% (low), 17.4±1.3% (euglycemic), 15.0±0.8% (hyperglycemic I), and 17.7±1.9% (hyperglycemic II) for calibration(PRE) and 67.5±9.5% (low), 24.2±1.8% (euglycemic), 15.5±0.9% (hyperglycemic I), and 15.3±1.9% (hyperglycemic II) for calibration(POST). In the low and euglycemic ranges MARD was significantly lower in calibration(PRE) compared with calibration(POST) (P=0.007 and P<0.001, respectively). Conclusions: Sensor calibration predominantly based on preprandial glucose resulted in a significantly higher overall sensor accuracy compared with a predominantly postprandial calibration. The difference was most pronounced in the hypo- and euglycemic reference range, whereas both calibration patterns were comparable in the hyperglycemic range.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIM Depending on intensity, exercise may induce a strong hormonal and metabolic response, including acid-base imbalances and changes in microcirculation, potentially interfering with the accuracy of continuous glucose monitoring (CGM). The present study aimed at comparing the accuracy of the Dexcom G4 Platinum (DG4P) CGM during continuous moderate and intermittent high-intensity exercise (IHE) in adults with type 1 diabetes (T1DM). METHODS Ten male individuals with well-controlled T1DM (HbA1c 7.0±0.6% [54±6mmol/mol]) inserted the DG4P sensor 2 days prior to a 90min cycling session (50% VO2peak) either with (IHE) or without (CONT) a 10s all-out sprint every 10min. Venous blood samples for reference glucose measurement were drawn every 10min and euglycemia (target 7mmol/l) was maintained using an oral glucose solution. Additionally, lactate and venous blood gas variables were determined. RESULTS Mean reference blood glucose was 7.6±0.2mmol/l during IHE and 6.7±0.2mmol/l during CONT (p<0.001). IHE resulted in significantly higher levels of lactate (7.3±0.5mmol/l vs. 2.6±0.3mmol/l, p<0.001), while pH values were significantly lower in the IHE group (7.27 vs. 7.38, p=0.001). Mean absolute relative difference (MARD) was 13.3±2.2% for IHE and 13.6±2.8% for CONT suggesting comparable accuracy (p=0.90). Using Clarke Error Grid Analysis, 100% of CGM values during both IHE and CONT were in zones A and B (IHE: 77% and 23%; CONT: 78% and 22%). CONCLUSIONS The present study revealed good and comparable accuracy of the DG4P CGM system during intermittent high intensity and continuous moderate intensity exercise, despite marked differences in metabolic conditions. This corroborates the clinical robustness of CGM under differing exercise conditions. CLINICAL TRIAL REGISTRATION NUMBER ClinicalTrials.gov NCT02068638.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

SMARTDIAB is a platform designed to support the monitoring, management, and treatment of patients with type 1 diabetes mellitus (T1DM), by combining state-of-the-art approaches in the fields of database (DB) technologies, communications, simulation algorithms, and data mining. SMARTDIAB consists mainly of two units: 1) the patient unit (PU); and 2) the patient management unit (PMU), which communicate with each other for data exchange. The PMU can be accessed by the PU through the internet using devices, such as PCs/laptops with direct internet access or mobile phones via a Wi-Fi/General Packet Radio Service access network. The PU consists of an insulin pump for subcutaneous insulin infusion to the patient and a continuous glucose measurement system. The aforementioned devices running a user-friendly application gather patient's related information and transmit it to the PMU. The PMU consists of a diabetes data management system (DDMS), a decision support system (DSS) that provides risk assessment for long-term diabetes complications, and an insulin infusion advisory system (IIAS), which reside on a Web server. The DDMS can be accessed from both medical personnel and patients, with appropriate security access rights and front-end interfaces. The DDMS, apart from being used for data storage/retrieval, provides also advanced tools for the intelligent processing of the patient's data, supporting the physician in decision making, regarding the patient's treatment. The IIAS is used to close the loop between the insulin pump and the continuous glucose monitoring system, by providing the pump with the appropriate insulin infusion rate in order to keep the patient's glucose levels within predefined limits. The pilot version of the SMARTDIAB has already been implemented, while the platform's evaluation in clinical environment is being in progress.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Self-monitoring of blood glucose plays an important role in the management of diabetes and has been shown to improve metabolic control. The use of blood glucose meters in clinical practice requires sufficient reliability to allow adequate treatment. Direct comparison of different blood glucose meters in clinical practice, independent of the manufactures is scarce. We, therefore, aimed to evaluate three frequently used blood glucose meters in daily clinical practice.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper two models for the simulation of glucose-insulin metabolism of children with Type 1 diabetes are presented. The models are based on the combined use of Compartmental Models (CMs) and artificial Neural Networks (NNs). Data from children with Type 1 diabetes, stored in a database, have been used as input to the models. The data are taken from four children with Type 1 diabetes and contain information about glucose levels taken from continuous glucose monitoring system, insulin intake and food intake, along with corresponding time. The influences of taken insulin on plasma insulin concentration, as well as the effect of food intake on glucose input into the blood from the gut, are estimated from the CMs. The outputs of CMs, along with previous glucose measurements, are fed to a NN, which provides short-term prediction of glucose values. For comparative reasons two different NN architectures have been tested: a Feed-Forward NN (FFNN) trained with the back-propagation algorithm with adaptive learning rate and momentum, and a Recurrent NN (RNN), trained with the Real Time Recurrent Learning (RTRL) algorithm. The results indicate that the best prediction performance can be achieved by the use of RNN.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Traditional approaches for nighttime glycemic control in glycogen storage disease type I (GSDI) include continuous tube feeding, or ingestion of uncooked corn starch (CS) at bedtime. A modified corn starch (MCS) has been shown to prolong euglycemia in some patients. The aim of this study was to evaluate whether stable nighttime glucose control can be achieved with other types of slowly digested carbohydrates in adult GSDI patients. METHODS In this cross-over study, nocturnal glucose control and fasting times were assessed with three different nocturnal nutrition regimens in five patients, using continuous glucose monitoring (CGMS) in an outpatient everyday life setting. For each patient, continuous glucose profiles were measured after ingestion of (1) CS, (2) MCS or (3) a pasta meal at bedtime, during 5 to 6 consecutive nights for each regimen. RESULTS Stable nocturnal glucose control was achieved for all patients with a pasta meal, with a mean duration of glycemia >3.5 mmol/l of 7.6 h (range 5.7-10.8), and >4 mmol/l of 7 h (5.2-9.2), similar to CS and MCS. Fasting glucose before breakfast on workdays (after 7.1 ± 0.8 h) was not significantly different between the three interventions (CS 4.1 ± 0.5 mmol/l, MCS 4.6 ± 0.7 mmol/l, pasta 4.3 ± 0.9 mmol/l). During prolonged fasting on weekends, longer duration of normoglycemia was achieved with CS or MCS than with pasta. CONCLUSION Consumption of cooked pasta is a suitable and more palatable alternative to uncooked corn starch to achieve nighttime glucose control in adult patients with GSDI.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Abstract Due to their representativeness and consistent measurement standards the medical und sports data of the Swiss conscripts provide a valuable basis for a continuous health monitoring of young Swiss men. During three to four years, the prevalence of overweight and obesity seems to stabilise on a high level. After a longer period of decreasing performance at the endurance test between the 1980s and 2002, the level of physical performance in the fitness test does no longer decrease since 2006. However, health and health behaviour show significant regional and socioeconomic inequalities among young Swiss men. Besides economic resources and education, major driving factors behind these inequalities can be identified in health knowledge, values, and attitudes.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Neovascular age-related macular degeneration (AMD) has a poor prognosis if left untreated, frequently resulting in legal blindness. Ranibizumab is approved for treating neovascular AMD. However, further guidance is needed to assist ophthalmologists in clinical practice to optimise treatment outcomes. METHODS: An international retina expert panel assessed evidence available from prospective, multicentre studies evaluating different ranibizumab treatment schedules (ANCHOR, MARINA, PIER, SAILOR, SUSTAIN and EXCITE) and a literature search to generate evidence-based and consensus recommendations for treatment indication and assessment, retreatment and monitoring. RESULTS: Ranibizumab is indicated for choroidal neovascular lesions with active disease, the clinical parameters of which are outlined. Treatment initiation with three consecutive monthly injections, followed by continued monthly injections, has provided the best visual-acuity outcomes in pivotal clinical trials. If continued monthly injections are not feasible after initiation, a flexible strategy appears viable, with monthly monitoring of lesion activity recommended. Initiation regimens of fewer than three injections have not been assessed. Continuous careful monitoring with flexible retreatment may help avoid vision loss recurring. Standardised biomarkers need to be determined. CONCLUSION: Evidence-based guidelines will help to optimise treatment outcomes with ranibizumab in neovascular AMD.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper aims at the development and evaluation of a personalized insulin infusion advisory system (IIAS), able to provide real-time estimations of the appropriate insulin infusion rate for type 1 diabetes mellitus (T1DM) patients using continuous glucose monitors and insulin pumps. The system is based on a nonlinear model-predictive controller (NMPC) that uses a personalized glucose-insulin metabolism model, consisting of two compartmental models and a recurrent neural network. The model takes as input patient's information regarding meal intake, glucose measurements, and insulin infusion rates, and provides glucose predictions. The predictions are fed to the NMPC, in order for the latter to estimate the optimum insulin infusion rates. An algorithm based on fuzzy logic has been developed for the on-line adaptation of the NMPC control parameters. The IIAS has been in silico evaluated using an appropriate simulation environment (UVa T1DM simulator). The IIAS was able to handle various meal profiles, fasting conditions, interpatient variability, intraday variation in physiological parameters, and errors in meal amount estimations.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Physiology and current knowledge about gestational diabetes which led to the adoption of new diagnostic criterias and blood glucose target levels during pregnancy by the Swiss Society for Endocrinology and Diabetes are reviewed. The 6th International Workshop Conference on Gestational Diabetes mellitus in Pasedena (2008) defined new diagnostic criteria based on the results of the HAPO-Trial. These criteria were during the ADA congress in New Orleans in 2009 presented. According to the new criteria there is no need for screening, but all pregnant women have to be tested with a 75 g oral glucose tolerance test between the 24th and 28th week of pregnancy. The new diagnostic values are very similar to the ones previously adopted by the ADA with the exception that only one out of three values has to be elevated in order to make the diagnosis of gestational diabetes. Due to this important difference it is very likely that gestational diabetes will be diagnosed more frequently in the future. The diagnostic criteria are: Fasting plasma glucose > or = 5.1 mmol/l, 1-hour value > or = 10.0 mmol/l or 2-hour value > or = 8.5 mmol/l. Based on current knowledge and randomized trials it is much more difficult to define glucose target levels during pregnancy. This difficulty has led to many different recommendations issued by diabetes societies. The Swiss Society of Endocrinology and Diabetes follows the arguments of the International Diabetes Federation (IDF) that self-blood glucose monitoring itself lacks precision and that there are very few randomized trials. Therefore, the target levels have to be easy to remember and might be slightly different in mmol/l or mg/dl. The Swiss Society for Endocrinology and Diabetes adopts the tentative target values of the IDF with fasting plasma glucose values < 5.3 mM and 1- and 2-hour postprandial (after the end of the meal) values of < 8.0 and 7.0 mmol/l, respectively. The last part of these recommendations deals with the therapeutic options during pregnancy (nutrition, physical exercise and pharmaceutical treatment). If despite lifestyle changes the target values are not met, approximately 25 % of patients have to be treated pharmaceutically. Insulin therapy is still the preferred treatment option, but metformin (and as an exception glibenclamide) can be used, if there are major hurdles for the initiation of insulin therapy.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The differential diagnosis for children with diabetes includes a group of monogenic diabetic disorders known as maturity-onset diabetes of the young (MODY). So far, six underlying gene defects have been identified. The most common subtypes are caused by mutations in the genes encoding the transcription factor HNF-1a (MODY 3) and the glycolytic enzyme glucokinase (GCK) (MODY 2). MODY 2 is the most benign form of diabetes as the threshold for glucose sensing is elevated resulting in mild, regulated hyperglycemia. MODY 2 may usually be treated with diet alone without risk of microvascular complications. Patients with MODY usually present as children or young adults. Genetic testing for MODY in diabetic subjects is often not performed because of the costs and its unavailability in Switzerland. We describe the impact of the genetic analysis for MODY 2 on diabetes management and treatment costs in a five-year-old girl. The patient and her diabetic mother were both found to have a heterozygous missense mutation (V203A) in the glucokinase gene. The five-year-old girl was started on insulin therapy for her diabetes but because her HbA1c remained between 5.8-6.4% (reference 4.1-5.7%) and her clinical presentation suggested MODY insulin was discontinued. She is now well controlled on a carbohydrate controlled diet regimen only. Omission of insulin treatment made regular blood glucose monitoring unnecessary and removed her risk of hypoglycemia. Costs for the genetic analysis were 500 Euro. At our centre costs for diabetes care of a patient with type 1 diabetes are approximately 2050 Euro/year compared to 410 Euro/year for the care of a patient with MODY 2. In addition, a diagnosis of MODY 2 may reassure patients and their families, as microvascular complications are uncommon. Thus there are both health and financial benefits in diagnosing MODY 2. We recommend genetic testing for MODY 2 in clinically selected patients even though this analysis is currently not available in Switzerland and costs are not necessarily covered by the health insurances.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND Morbidity and mortality in T1DM depend on metabolic control, which is assessed by HbA1c measurements every 3-4 months. Patients' self-perception of glycemic control depends on daily blood glucose monitoring. Little is known about the congruence of patients' and professionals' perception of metabolic control in T1DM. OBJECTIVE To assess the actual patients' self-perception and objective assessment (HbA1c) of metabolic control in T1DM children and adolescents and to investigate the possible factors involved in any difference. METHODS Patients with T1DM aged 8 - 18 years were recruited in a cross-sectional, retrospective and prospective cohort study. Data collection consisted of clinical details, measured HbA1c, self-monitored blood glucose values and questionnaires assessing self and professionals' judgment of metabolic control. RESULTS 91 patients participated. Mean HbA1c was 8.03%. HbA1c was higher in patients with a diabetes duration > 2 years (p = 0.025) and in patients of lower socioeconomic level (p = 0.032). No significant correlation was found for self-perception of metabolic control in well and poorly controlled patients. We found a trend towards false-positive memory of the last HbA1c in patients with a HbA1c > 8.5% (p = 0.069) but no difference in patients' knowledge on target HbA1c between well and poorly controlled patients. CONCLUSIONS T1DM patients are aware of a target HbA1c representing good metabolic control. Ill controlled patients appear to have a poorer recollection of their HbA1c. Self-perception of actual metabolic control is similar in well and poorly controlled T1DM children and adolescents. Therefore, professionals should pay special attention that ill controlled T1DM patients perceive their HbA1c correctly.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Object Resection of lesions close to the primary motor cortex (M1) and the corticospinal tract (CST) is generally regarded as high-risk surgery due to reported rates of postoperative severe deficits of up to 50%. The authors' objective was to determine the feasibility and safety of low-threshold motor mapping and its efficacy for increasing the extent of lesion resection in the proximity of M1 and the CST in children and adolescents. Methods The authors analyzed 8 consecutive pediatric patients in whom they performed 9 resections for lesions within or close (≤ 10 mm) to M1 and/or the CST. Monopolar high-frequency motor mapping with train-of-five stimuli (pulse duration 500 μsec, interstimulus interval 4.0 msec, frequency 250 Hz) was used. The motor threshold was defined as the minimal stimulation intensity that elicited motor evoked potentials (MEPs) from target muscles (amplitude > 30 μV). Resection was performed toward M1 and the CST at sites negative to 1- to 3-mA high-frequency train-of-five stimulation. Results The M1 was identified through high-frequency train-of-five via application of varying low intensities. The lowest motor thresholds after final resection ranged from 1 to 9 mA in 8 cases and up to 18 mA in 1 case, indicating proximity to motor neurons. Intraoperative electroencephalography documented an absence of seizures during all surgeries. Two transient neurological deficits were observed, but there were no permanent deficits. Postoperative imaging revealed complete resection in 8 patients and a very small remnant (< 0.175 cm(3)) in 1 patient. Conclusions High-frequency train-of-five with a minimal threshold of 1-3 mA is a feasible and safe procedure for resections in the proximity of the CST. Thus, low-threshold motor mapping might help to expand the area for safe resection in pediatric patients with lesions located within the precentral gyrus and close to the CST, and may be regarded as a functional navigational tool. The additional use of continuous MEP monitoring serves as a safety feedback for the functional integrity of the CST, especially because the true excitability threshold in children is unknown.