18 resultados para Context Based Access Control System
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
To date, few risk factors for childhood acute lymphoblastic leukemia (ALL) have been confirmed and the scientific literature is full of controversial "evidence." We examined if family characteristics, particularly maternal and paternal age and number of older siblings, were risk factors for childhood acute lymphoblastic leukemia (ALL).
Resumo:
BACKGROUND: In this paper we present a landmark-based augmented reality (AR) endoscope system for endoscopic paranasal and transnasal surgeries along with fast and automatic calibration and registration procedures for the endoscope. METHODS: Preoperatively the surgeon selects natural landmarks or can define new landmarks in CT volume. These landmarks are overlaid, after proper registration of preoperative CT to the patient, on the endoscopic video stream. The specified name of the landmark, along with selected colour and its distance from the endoscope tip, is also augmented. The endoscope optics are calibrated and registered by fast and automatic methods. Accuracy of the system is evaluated in a metallic grid and cadaver set-up. RESULTS: Root mean square (RMS) error of the system is 0.8 mm in a controlled laboratory set-up (metallic grid) and was 2.25 mm during cadaver studies. CONCLUSIONS: A novel landmark-based AR endoscope system is implemented and its accuracy is evaluated. Augmented landmarks will help the surgeon to orientate and navigate the surgical field. Studies prove the capability of the system for the proposed application. Further clinical studies are planned in near future.
Resumo:
The human face is a vital component of our identity and many people undergo medical aesthetics procedures in order to achieve an ideal or desired look. However, communication between physician and patient is fundamental to understand the patient’s wishes and to achieve the desired results. To date, most plastic surgeons rely on either “free hand” 2D drawings on picture printouts or computerized picture morphing. Alternatively, hardware dependent solutions allow facial shapes to be created and planned in 3D, but they are usually expensive or complex to handle. To offer a simple and hardware independent solution, we propose a web-based application that uses 3 standard 2D pictures to create a 3D representation of the patient’s face on which facial aesthetic procedures such as filling, skin clearing or rejuvenation, and rhinoplasty are planned in 3D. The proposed application couples a set of well-established methods together in a novel manner to optimize 3D reconstructions for clinical use. Face reconstructions performed with the application were evaluated by two plastic surgeons and also compared to ground truth data. Results showed the application can provide accurate 3D face representations to be used in clinics (within an average of 2 mm error) in less than 5 min.
Resumo:
Determining the expected age at a potential ice-core drilling site on a polar ice sheet generally depends on a combination of information from remote-sensing methods, estimates of current accumulation and modelling. This poses irreducible uncertainties in retrieving an undisturbed ice core of the desired age. Although recently perfected radar techniques will improve the picture of the ice sheet below future drilling sites, rapid prospective drillings could further increase the success of deep drilling projects. Here we design and explore a drilling system for a minimum-size rapid-access hole. The advantages of a small hole are the low demand for drilling fluid, low overall weight of the equipment, fast installing and de-installing and low costs. We show that, in theory, drilling of a 20mm hole to a depth of 3000m is possible in ~4 days. First concepts have been realized and verified in the field. Both the drill cuttings and the hole itself can be used to characterize the properties of the ice sheet and its potential to provide a trustworthy palaeo-record. A candidate drilling site could be explored in ~2 weeks, which would enable the characterization of several sites in one summer season.
Resumo:
In this paper we present the results from the coverage and the orbit determination accuracy simulations performed within the recently completed ESA study “Assessment Study for Space Based Space Surveillance (SBSS) Demonstration System” (Airbus Defence and Space consortium). This study consisted in investigating the capability of a space based optical sensor (SBSS) orbiting in low Earth orbit (LEO) to detect and track objects in GEO (geosynchronous orbit), MEO (medium Earth orbit) and LEO and to determinate and improve initial orbits from such observations. Space based systems may achieve better observation conditions than ground based sensors in terms of astrometric accuracy, detection coverage, and timeliness. The primary observation mode of the proposed SBSS demonstrator is GEO surveillance, i.e. the systematic search and detection of unknown and known objects. GEO orbits are specific and unique orbits from dynamical point of view. A space-based sensor may scan the whole GEO ring within one sidereal day if the orbit and pointing directions are chosen properly. For an efficient survey, our goal was to develop a leak-proof GEO fence strategy. Collaterally, we show that also MEO, LEO and other (GTO,Molniya, etc.) objects would be possible to observe by the system and for a considerable number of LEO objects to down to size of 1 cm we can obtain meaningful statistical data for improvement and validation of space debris environment models
Resumo:
OBJECTIVE Use of diuretics has been associated with an increased risk of gout. Data on different types of diuretics are scarce. We undertook this study to investigate the association between use of loop diuretics, thiazide or thiazide-like diuretics, and potassium-sparing agents and the risk of developing incident gout. METHODS We conducted a retrospective population-based case-control analysis using the General Practice Research Database established in the UK. We identified case patients who were diagnosed as having incident gout between 1990 and 2010. One control patient was matched to each case patient for age, sex, general practice, calendar time, and years of active history in the database. We used conditional logistic regression to calculate odds ratios (ORs) and 95% confidence intervals (95% CIs), and we adjusted for potential confounders. RESULTS We identified 91,530 incident cases of gout and the same number of matched controls. Compared to past use of diuretics from each respective drug class, adjusted ORs for current use of loop diuretics, thiazide diuretics, thiazide-like diuretics, and potassium-sparing diuretics were 2.64 (95% CI 2.47-2.83), 1.70 (95% CI 1.62-1.79), 2.30 (95% CI 1.95-2.70), and 1.06 (95% CI 0.91-1.23), respectively. Combined use of loop diuretics and thiazide diuretics was associated with the highest relative risk estimates of gout (adjusted OR 4.65 [95% CI 3.51-6.16]). Current use of calcium channel blockers or losartan slightly attenuated the risk of gout in patients who took diuretics. CONCLUSION Use of loop diuretics, thiazide diuretics, and thiazide-like diuretics was associated with an increased risk of incident gout, although use of potassium-sparing agents was not.
Resumo:
OBJECTIVE The aim of this study was to explore the risk of incident gout in patients with type 2 diabetes mellitus (T2DM) in association with diabetes duration, diabetes severity and antidiabetic drug treatment. METHODS We conducted a case-control study in patients with T2DM using the UK-based Clinical Practice Research Datalink (CPRD). We identified case patients aged ≥18 years with an incident diagnosis of gout between 1990 and 2012. We matched to each case patient one gout-free control patient. We used conditional logistic regression analysis to calculate adjusted ORs (adj. ORs) with 95% CIs and adjusted our analyses for important potential confounders. RESULTS The study encompassed 7536 T2DM cases with a first-time diagnosis of gout. Compared to a diabetes duration <1 year, prolonged diabetes duration (1-3, 3-6, 7-9 and ≥10 years) was associated with decreased adj. ORs of 0.91 (95% CI 0.79 to 1.04), 0.76 (95% CI 0.67 to 0.86), 0.70 (95% CI 0.61 to 0.86), and 0.58 (95% CI 0.51 to 0.66), respectively. Compared to a reference A1C level of <7%, the risk estimates of increasing A1C levels (7.0-7.9, 8.0-8.9 and ≥9%) steadily decreased with adj. ORs of 0.79 (95% CI 0.72 to 0.86), 0.63 (95% CI 0.55 to 0.72), and 0.46 (95% CI 0.40 to 0.53), respectively. Neither use of insulin, metformin, nor sulfonylureas was associated with an altered risk of incident gout. CONCLUSIONS Increased A1C levels, but not use of antidiabetic drugs, was associated with a decreased risk of incident gout among patients with T2DM.
Resumo:
OBJECTIVE This study aims to assess the odds of developing incident gout in association with the use of postmenopausal estrogen-progestogen therapy, according to type, timing, duration, and route of administration of estrogen-progestogen therapy. METHODS We conducted a retrospective population-based case-control analysis using the United Kingdom-based Clinical Practice Research Datalink. We identified women (aged 45 y or older) who had a first-time diagnosis of gout recorded between 1990 and 2010. We matched one female control with each case on age, general practice, calendar time, and years of active history in the database. We used multivariate conditional logistic regression to calculate odds ratios (ORs) with 95% CIs (adjusted for confounders). RESULTS The adjusted OR for gout with current use of oral formulations of opposed estrogens (estrogen-progestogen) was 0.69 (95% CI, 0.56-0.86) compared with never use. Current use was associated with a decreased OR for gout in women without renal failure (adjusted OR, 0.71; 95% CI, 0.57-0.87) and hypertension (adjusted OR, 0.62; 95% CI, 0.44-0.87) compared with never use. Tibolone was associated with a decreased OR for gout (adjusted OR, 0.77; 95% CI, 0.63-0.95) compared with never use. Estrogens alone did not alter the OR for gout. CONCLUSIONS Current use of oral opposed estrogens, but not unopposed estrogens, is associated with a decreased OR for incident gout in women without renal failure and is more pronounced in women with hypertension. Use of tibolone is associated with a decreased OR for incident gout. The decreased OR for gout may be related to the progestogen component rather than the estrogen component.
Resumo:
PURPOSE Laser range scanners (LRS) allow performing a surface scan without physical contact with the organ, yielding higher registration accuracy for image-guided surgery (IGS) systems. However, the use of LRS-based registration in laparoscopic liver surgery is still limited because current solutions are composed of expensive and bulky equipment which can hardly be integrated in a surgical scenario. METHODS In this work, we present a novel LRS-based IGS system for laparoscopic liver procedures. A triangulation process is formulated to compute the 3D coordinates of laser points by using the existing IGS system tracking devices. This allows the use of a compact and cost-effective LRS and therefore facilitates the integration into the laparoscopic setup. The 3D laser points are then reconstructed into a surface to register to the preoperative liver model using a multi-level registration process. RESULTS Experimental results show that the proposed system provides submillimeter scanning precision and accuracy comparable to those reported in the literature. Further quantitative analysis shows that the proposed system is able to achieve a patient-to-image registration accuracy, described as target registration error, of [Formula: see text]. CONCLUSIONS We believe that the presented approach will lead to a faster integration of LRS-based registration techniques in the surgical environment. Further studies will focus on optimizing scanning time and on the respiratory motion compensation.
Resumo:
Percutaneous needle intervention based on PET/CT images is effective, but exposes the patient to unnecessary radiation due to the increased number of CT scans required. Computer assisted intervention can reduce the number of scans, but requires handling, matching and visualization of two different datasets. While one dataset is used for target definition according to metabolism, the other is used for instrument guidance according to anatomical structures. No navigation systems capable of handling such data and performing PET/CT image-based procedures while following clinically approved protocols for oncologic percutaneous interventions are available. The need for such systems is emphasized in scenarios where the target can be located in different types of tissue such as bone and soft tissue. These two tissues require different clinical protocols for puncturing and may therefore give rise to different problems during the navigated intervention. Studies comparing the performance of navigated needle interventions targeting lesions located in these two types of tissue are not often found in the literature. Hence, this paper presents an optical navigation system for percutaneous needle interventions based on PET/CT images. The system provides viewers for guiding the physician to the target with real-time visualization of PET/CT datasets, and is able to handle targets located in both bone and soft tissue. The navigation system and the required clinical workflow were designed taking into consideration clinical protocols and requirements, and the system is thus operable by a single person, even during transition to the sterile phase. Both the system and the workflow were evaluated in an initial set of experiments simulating 41 lesions (23 located in bone tissue and 18 in soft tissue) in swine cadavers. We also measured and decomposed the overall system error into distinct error sources, which allowed for the identification of particularities involved in the process as well as highlighting the differences between bone and soft tissue punctures. An overall average error of 4.23 mm and 3.07 mm for bone and soft tissue punctures, respectively, demonstrated the feasibility of using this system for such interventions. The proposed system workflow was shown to be effective in separating the preparation from the sterile phase, as well as in keeping the system manageable by a single operator. Among the distinct sources of error, the user error based on the system accuracy (defined as the distance from the planned target to the actual needle tip) appeared to be the most significant. Bone punctures showed higher user error, whereas soft tissue punctures showed higher tissue deformation error.
Resumo:
Over the past several years, a number of design approaches in wireless mesh networks have been introduced to support the deployment of wireless mesh networks (WMNs). We introduce a novel wireless mesh architecture that supports authentication and authorisation functionalities, giving the possibility of a seamless WMN integration into the home's organization authentication and authorisation infrastructure. First, we introduce a novel authentication and authorisation mechanism for wireless mesh nodes. The mechanism is designed upon an existing federated access control approach, i.e. the AAI infrastructure that is using just the credentials at the user's home organization in a federation. Second, we demonstrate how authentication and authorisation for end users is implemented by using an existing web-based captive portal approach. Finally, we observe the difference between the two and explain in detail the process flow of authorized access to network resources in wireless mesh networks. The goal of our wireless mesh architecture is to enable easy broadband network access to researchers at remote locations, giving them additional advantage of a secure access to their measurements, irrespective of their location. It also provides an important basis for the real-life deployment of wireless mesh networks for the support of environmental research.
Resumo:
This article reports about the internet based, second multicenter study (MCS II) of the spine study group (AG WS) of the German trauma association (DGU). It represents a continuation of the first study conducted between the years 1994 and 1996 (MCS I). For the purpose of one common, centralised data capture methodology, a newly developed internet-based data collection system ( http://www.memdoc.org ) of the Institute for Evaluative Research in Orthopaedic Surgery of the University of Bern was used. The aim of this first publication on the MCS II was to describe in detail the new method of data collection and the structure of the developed data base system, via internet. The goal of the study was the assessment of the current state of treatment for fresh traumatic injuries of the thoracolumbar spine in the German speaking part of Europe. For that reason, we intended to collect large number of cases and representative, valid information about the radiographic, clinical and subjective treatment outcomes. Thanks to the new study design of MCS II, not only the common surgical treatment concepts, but also the new and constantly broadening spectrum of spine surgery, i.e. vertebro-/kyphoplasty, computer assisted surgery and navigation, minimal-invasive, and endoscopic techniques, documented and evaluated. We present a first statistical overview and preliminary analysis of 18 centers from Germany and Austria that participated in MCS II. A real time data capture at source was made possible by the constant availability of the data collection system via internet access. Following the principle of an application service provider, software, questionnaires and validation routines are located on a central server, which is accessed from the periphery (hospitals) by means of standard Internet browsers. By that, costly and time consuming software installation and maintenance of local data repositories are avoided and, more importantly, cumbersome migration of data into one integrated database becomes obsolete. Finally, this set-up also replaces traditional systems wherein paper questionnaires were mailed to the central study office and entered by hand whereby incomplete or incorrect forms always represent a resource consuming problem and source of error. With the new study concept and the expanded inclusion criteria of MCS II 1, 251 case histories with admission and surgical data were collected. This remarkable number of interventions documented during 24 months represents an increase of 183% compared to the previously conducted MCS I. The concept and technical feasibility of the MEMdoc data collection system was proven, as the participants of the MCS II succeeded in collecting data ever published on the largest series of patients with spinal injuries treated within a 2 year period.