4 resultados para Contamination during Obturation

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The association of simian virus 40 (SV40) with malignant pleural mesothelioma is currently under debate. In some malignancies of viral aetiology, viral DNA can be detected in the patients' serum or plasma. To characterize the prevalence of SV40 in Swiss mesothelioma patients, we optimized a real-time PCR for quantitative detection of SV40 DNA in plasma, and used a monoclonal antibody for immunohistochemical detection of SV40 in mesothelioma tissue microarrays. Real-time PCR was linear over five orders of magnitude, and sensitive to a single gene copy. Repeat PCR determinations showed excellent reproducibility. However, SV40 status varied for independent DNA isolates of single samples. We noted that SV40 detection rates by PCR were drastically reduced by the implementation of strict room compartmentalization and decontamination procedures. Therefore, we systematically addressed common sources of contamination and found no cross-reactivity with DNA of other polyomaviruses. Contamination during PCR was rare and plasmid contamination was infrequent. SV40 DNA was reproducibly detected in only 4 of 78 (5.1%) plasma samples. SV40 DNA levels were low and not consistently observed in paired plasma and tumour samples from the same patient. Immunohistochemical analysis revealed a weak but reproducible SV40 staining in 16 of 341 (4.7%) mesotheliomas. Our data support the occurrence of non-reproducible SV40 PCR amplifications and underscore the importance of proper sample handling and analysis. SV40 DNA and protein were found at low prevalence (5%) in plasma and tumour tissue, respectively. This suggests that SV40 does not appear to play a major role in the development of mesothelioma.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Bacterial contamination of endoscopy suites is of concern; however studies evaluating bacterial aerosols are lacking. We aimed to determine the effectiveness of air suctioning during removal of biopsy forceps in reducing bacterial air contamination.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Stray light contamination reduces considerably the precision of photometric of faint stars for low altitude spaceborne observatories. When measuring faint objects, the necessity of coping with stray light contamination arises in order to avoid systematic impacts on low signal-to-noise images. Stray light contamination can be represented by a flat offset in CCD data. Mitigation techniques begin by a comprehensive study during the design phase, followed by the use of target pointing optimisation and post-processing methods. We present a code that aims at simulating the stray-light contamination in low-Earth orbit coming from reflexion of solar light by the Earth. StrAy Light SimulAtor (SALSA) is a tool intended to be used at an early stage as a tool to evaluate the effective visible region in the sky and, therefore to optimise the observation sequence. SALSA can compute Earth stray light contamination for significant periods of time allowing missionwide parameters to be optimised (e.g. impose constraints on the point source transmission function (PST) and/or on the altitude of the satellite). It can also be used to study the behaviour of the stray light at different seasons or latitudes. Given the position of the satellite with respect to the Earth and the Sun, SALSA computes the stray light at the entrance of the telescope following a geometrical technique. After characterising the illuminated region of the Earth, the portion of illuminated Earth that affects the satellite is calculated. Then, the flux of reflected solar photons is evaluated at the entrance of the telescope. Using the PST of the instrument, the final stray light contamination at the detector is calculated. The analysis tools include time series analysis of the contamination, evaluation of the sky coverage and an objects visibility predictor. Effects of the South Atlantic Anomaly and of any shutdown periods of the instrument can be added. Several designs or mission concepts can be easily tested and compared. The code is not thought as a stand-alone mission designer. Its mandatory inputs are a time series describing the trajectory of the satellite and the characteristics of the instrument. This software suite has been applied to the design and analysis of CHEOPS (CHaracterizing ExOPlanet Satellite). This mission requires very high precision photometry to detect very shallow transits of exoplanets. Different altitudes and characteristics of the detector have been studied in order to find the best parameters, that reduce the effect of contamination. © (2014) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Heater-cooler units (HCUs) were recently identified as a source of Mycobacterium chimaera causing surgical site infections. We investigated transmission of this bacterium from HCUs to the surgical field by using a thermic anemometer and particle counter, videotape of an operating room equipped with an ultraclean laminar airflow ventilation system, and bacterial culture sedimentation plates in a nonventilated room. Smoke from the HCU reached the surgical field in 23 s by merging with ultraclean air. The HCU produced on average 5.2, 139, and 14.8 particles/min in the surgical field at positions Off, On/oriented toward, and On/oriented away, respectively. Culture plates were positive for M. chimaera <5 m from the HCU in the test room. These experiments confirm airborne transmission of M. chimaera aerosols from a contaminated HCU to an open surgical field despite ultraclean air ventilation. Efforts to mitigate infectious risks during surgery should consider contamination from water sources and airflow-generating devices.