75 resultados para Circular esophageal myotomy
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Esophageal dilation often leads to long-lasting relief of dysphagia in eosinophilic esophagitis (EoE). The aim of this study was to define the effectiveness, safety, and patient acceptance of esophageal dilation in EoE. In addition, we examined the influence of dilation on the underlying esophageal inflammation.
Resumo:
There is no standard treatment for patients with locally advanced esophageal carcinoma without systemic metastasis in whom surgery is no longer considered a reasonable option.
Resumo:
This multicenter phase IB/II trial investigated cetuximab added to preoperative chemoradiotherapy for esophageal cancer.
Resumo:
EUS response assessment in patients with locally advanced esophageal cancer undergoing neoadjuvant chemoradiation therapy (CRT) is limited by disintegration of the involved anatomic structures.
Resumo:
Gastro-esophageal reflux is considered a major culprit in the pathogenesis of Barrett's esophagus (BE). Still, there is controversy on the role of weakly acidic and weakly alkaline reflux in BE. To compare characteristics of reflux episodes patients with BE, erosive esophagitis (EE), and healthy volunteers (HV).
Resumo:
Background—Pulmonary vein stenosis (PVST) is a well-known complication of pulmonary vein isolation (PVI). Specific anatomically designed ablation catheters for antral PVI have not been evaluated with regard to the incidence of PVST. We investigated the incidence, severity, and characteristics of PVST after PVI with the Pulmonary Vein Ablation Catheter (PVAC) and phased radiofrequency technology. Methods and Results A total of 100 patients (55 men) underwent PVI for atrial fibrillation using the PVAC. PVI was guided by selective angiography of each pulmonary vein (PV) in 70 (70%) patients and by reconstructed 3D atriography (ATG) in 30 (30%) patients. Gadolinium-enhanced MRI or multidetector CT was performed in all patients before treatment and 93±78 days after PVI. PVST was classified as follows: insignificant (<25%), mild (25%–50%), moderate (50%–75%), or severe (>75%). A total of 410 PVs were analyzed. Cardiac imaging demonstrated a detectable narrowing of the PV diameter in 23 (23%) patients and in 28 (7%) PVs. In detail, insignificant PVST was observed in 12 (2.9%) PVs, mild PVST in 15 (3.7%), and moderate PVST in 1 (0.2%). No instances of severe PVST were observed. The use of 3D-ATG was associated with a lower incidence of PVST (0.8% [95% CI, 0.0%–2.2%] versus 5.4% [95% CI, 2.7%–8.1%], P=0.027). Conclusions To our knowledge, this study is the first to report the incidence of PVST using the PVAC. In this regard, the PVAC seems to be safe if used in an experienced center. In addition, the use of 3D-ATG may decrease the risk of PVST.
Resumo:
Two healthy cats underwent elective surgical procedures under general anesthesia. One developed severe esophagitis leading to esophageal rupture, mediastinitis, and pyothorax. The other cat developed esophageal stricture, diverticulum formation, and suspected iatrogenic perforation. Both cats had signs of dysphagia and regurgitation beginning a few days after anesthesia. The first cat also had severe dyspnea due to septic pleural effusion and pneumomediastinum. In the second cat, endoscopy revealed diffuse esophagitis, an esophageal stricture, and a large esophageal diverticulum. Rupture of the esophageal wall occurred while inflating the esophagus for inspection. Due to the poor prognosis, both cats were euthanized. Necropsy revealed severe esophageal changes. Postanesthetic esophagitis has been previously described in dogs and cats; however, severe life-threatening esophageal injuries rarely occur as a sequel to general anesthesia. To the authors' knowledge, esophageal rupture secondary to perianesthetic reflux has never been reported in cats.
Resumo:
OBJECTIVE: To report stabilization of closed, comminuted distal metaphyseal transverse fractures of the left tibia and fibula in a tiger using a hybrid circular-linear external skeletal fixator. STUDY DESIGN: Clinical report. ANIMAL: Juvenile tiger (15 months, 90 kg). METHODS: From imaging studies, the tiger had comminuted distal metaphyseal transverse fractures of the left tibia and fibula, with mild caudolateral displacement and moderate compression. Multiple fissures extended from the fractures through the distal metaphyses, extending toward, but not involving the distal tibial and fibular physes. A hybrid circular-linear external skeletal fixator was applied by closed reduction, to stabilize the fractures. RESULTS: The fractures healed and the fixator was removed 5 weeks after stabilization. Limb length and alignment were similar to the normal contralateral limb at hospital discharge, 8 weeks after surgery. Two weeks later, the tiger had fractures of the right tibia and fibula and was euthanatized. Necropsy confirmed pathologic fractures ascribed to copper deficiency. CONCLUSION: Closed application of the hybrid construct provided sufficient stability to allow this 90 kg tiger's juxta-articular fractures to heal with minimal complications and without disrupting growth from the adjacent physes.
Resumo:
Three horses (age 17 - 23 years) were referred to the equine clinic of the University of Berne due to colic, fever, tachycardia and tachypnea. All horses showed pleural effusion. Clinical findings in 2 of the horses were highly suggestive of an intra-thoracic esophageal perforation. Severe septic pleuropneumonia without suspicion of an esophageal lesion was diagnosed in the 3rd horse. In addition, an 11 year old stallion was referred to the equine clinic for treatment of a presumptive large colon impaction. The horse was given laxatives after nasogastric intubation. Subsequent dramatic clinical deterioration and signs consistent with severe pleuropneumonia suggest that esophageal perforation had occurred when passing the nasogastric tube. All 4 horses were euthanized due to a poor prognosis. Esophageal perforation was diagnosed or confirmed post mortem in all cases. A hypertrophy of the tunica muscularis of the intra-thoracic esophagus was found in 3 of 4 horses.
Resumo:
Introduction: Diagnosing arrhythmias by conventional Holter-ECG can be cumbersome because of artifacts, skin irritation and poor P-waves. In contrast, esophageal electrocardiography (eECG) is promising due to the anatomic relationship of the esophagus to the atria and its favorable bioelectric properties. Methods used: In an ambulant setting, we recorded eECGs from 10 volunteers with a novel, highly-miniaturized eECG recorder that is worn discretely behind the ear (1.5×1.8×5cm, 22grams). The device continuously records two eECG leads during 3 days with 500Hz sampling frequency and 24-bit resolution. Results: Mean ± SD recording time was 21.7±19.6 hours (max. 60 hours). Test persons were not limited in daily activities (e.g. eating, speaking) and only complained mild discomfort during probe insertion, which subsided later on. During 99.8% of time, the recorder acquired signals appropriate for further analysis. In unfiltered data, QRS complexes and P-waves were identifiable during >98% of time. P waves had higher amplitudes as compared to surface ECG (0.71 ± 0.42mV vs. 0.16 ± 0.03mV, p = 0.004). No complications occurred. Conclusion: Ambulatory eECG recording is safe, well tolerated and promising due to excellent P-wave detection, overcoming some limitations of conventional Holter ECG.
Resumo:
Two commercially available electrode catheters are examined for their suitability in esophageal long-term ECG recordings. Both, electrical sensing characteristics as well as clinical acceptance were investigated in a clinical study including inpatients with cardiovascular diseases. In total, 31 esophageal ECG were obtained in 36 patients. Results showed that esophageal electrodes were well tolerated by the patients. Hemispherical electrodes with higher diameter required more insertion attempts and were associated with increased failure rates as compared to cylindrical electrodes. In contrast, the higher surface area of hemispherical electrodes resulted in significantly higher signal-to-noise ratio. Contact impedance was equal for both electrode types, but esophageal electrodes had lower impedance if compared with skin electrodes.