38 resultados para Carlo III, Duke of Savoy, 1504-1553.
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Critical limb ischaemia (CLI) is a particularly severe manifestation of lower limb atherosclerosis posing a major threat to both limb and life of affected patients. Besides arterial revascularisation, risk-factor modification and administration of antiplatelet therapy is a major goal in the treatment of CLI patients. Key elements of cardiovascular risk management are smoking cessation and treatment of hyperlipidaemia with dietary modification or statins. Moreover, arterial hypertension and diabetes mellitus should be adequately treated. In CLI patients not suitable for arterial revascularisation or subsequent to unsuccessful revascularisation, parenteral prostanoids may be considered. CLI patients undergoing surgical revascularisation should be treated with beta blockers. At present, neither gene nor stem-cell therapy can be recommended outside clinical trials. Of note, walking exercise is contraindicated in CLI patients due to the risk of worsening pre-existing or causing new ischaemic wounds. CLI patients are oftentimes medically frail and exhibit significant comorbidities. Co-existing coronary heart and carotid as well as renal artery disease should be managed according to current guidelines. Considering the above-mentioned treatment goals, interdisciplinary treatment approaches for CLI patients are warranted. Aim of the present manuscript is to discuss currently existing evidence for both the management of cardiovascular risk factors and treatment of co-existing disease and to deduct specific treatment recommendations.
Resumo:
The electron Monte Carlo (eMC) dose calculation algorithm available in the Eclipse treatment planning system (Varian Medical Systems) is based on the macro MC method and uses a beam model applicable to Varian linear accelerators. This leads to limitations in accuracy if eMC is applied to non-Varian machines. In this work eMC is generalized to also allow accurate dose calculations for electron beams from Elekta and Siemens accelerators. First, changes made in the previous study to use eMC for low electron beam energies of Varian accelerators are applied. Then, a generalized beam model is developed using a main electron source and a main photon source representing electrons and photons from the scattering foil, respectively, an edge source of electrons, a transmission source of photons and a line source of electrons and photons representing the particles from the scrapers or inserts and head scatter radiation. Regarding the macro MC dose calculation algorithm, the transport code of the secondary particles is improved. The macro MC dose calculations are validated with corresponding dose calculations using EGSnrc in homogeneous and inhomogeneous phantoms. The validation of the generalized eMC is carried out by comparing calculated and measured dose distributions in water for Varian, Elekta and Siemens machines for a variety of beam energies, applicator sizes and SSDs. The comparisons are performed in units of cGy per MU. Overall, a general agreement between calculated and measured dose distributions for all machine types and all combinations of parameters investigated is found to be within 2% or 2 mm. The results of the dose comparisons suggest that the generalized eMC is now suitable to calculate dose distributions for Varian, Elekta and Siemens linear accelerators with sufficient accuracy in the range of the investigated combinations of beam energies, applicator sizes and SSDs.
Resumo:
This phase III trial compared the efficacy and safety of gemcitabine (Gem) plus capecitabine (GemCap) versus single-agent Gem in advanced/metastatic pancreatic cancer.
Resumo:
The comparison of radiotherapy techniques regarding secondary cancer risk has yielded contradictory results possibly stemming from the many different approaches used to estimate risk. The purpose of this study was to make a comprehensive evaluation of different available risk models applied to detailed whole-body dose distributions computed by Monte Carlo for various breast radiotherapy techniques including conventional open tangents, 3D conformal wedged tangents and hybrid intensity modulated radiation therapy (IMRT). First, organ-specific linear risk models developed by the International Commission on Radiological Protection (ICRP) and the Biological Effects of Ionizing Radiation (BEIR) VII committee were applied to mean doses for remote organs only and all solid organs. Then, different general non-linear risk models were applied to the whole body dose distribution. Finally, organ-specific non-linear risk models for the lung and breast were used to assess the secondary cancer risk for these two specific organs. A total of 32 different calculated absolute risks resulted in a broad range of values (between 0.1% and 48.5%) underlying the large uncertainties in absolute risk calculation. The ratio of risk between two techniques has often been proposed as a more robust assessment of risk than the absolute risk. We found that the ratio of risk between two techniques could also vary substantially considering the different approaches to risk estimation. Sometimes the ratio of risk between two techniques would range between values smaller and larger than one, which then translates into inconsistent results on the potential higher risk of one technique compared to another. We found however that the hybrid IMRT technique resulted in a systematic reduction of risk compared to the other techniques investigated even though the magnitude of this reduction varied substantially with the different approaches investigated. Based on the epidemiological data available, a reasonable approach to risk estimation would be to use organ-specific non-linear risk models applied to the dose distributions of organs within or near the treatment fields (lungs and contralateral breast in the case of breast radiotherapy) as the majority of radiation-induced secondary cancers are found in the beam-bordering regions.
Resumo:
BACKGROUND AND AIMS Inflammatory bowel disease (IBD) frequently manifests during childhood and adolescence. For providing and understanding a comprehensive picture of a patients' health status, health-related quality of life (HRQoL) instruments are an essential complement to clinical symptoms and functional limitations. Currently, the IMPACT-III questionnaire is one of the most frequently used disease-specific HRQoL instrument among patients with IBD. However, there is a lack of studies examining the validation and reliability of this instrument. METHODS 146 paediatric IBD patients from the multicenter Swiss IBD paediatric cohort study database were included in the study. Medical and laboratory data were extracted from the hospital records. HRQoL data were assessed by means of standardized questionnaires filled out by the patients in a face-to-face interview. RESULTS The original six IMPACT-III domain scales could not be replicated in the current sample. A principal component analysis with the extraction of four factor scores revealed the most robust solution. The four factors indicated good internal reliability (Cronbach's alpha=.64-.86), good concurrent validity measured by correlations with the generic KIDSCREEN-27 scales and excellent discriminant validity for the dimension of physical functioning measured by HRQoL differences for active and inactive severity groups (p<.001, d=1.04). CONCLUSIONS This study with Swiss children with IBD indicates good validity and reliability for the IMPACT-III questionnaire. However, our findings suggest a slightly different factor structure than originally proposed. The IMPACT-III questionnaire can be recommended for its use in clinical practice. The factor structure should be further examined in other samples.
Resumo:
Previous restriction analysis of cloned equine DNA and genomic DNA of equine peripheral blood mononuclear cells had indicated the existence of one c epsilon, one c alpha and up to six c gamma genes in the haploid equine genome. The c epsilon and c alpha genes have been aligned on a 30 kb DNA fragment in the order 5' c epsilon-c alpha 3'. Here we describe the alignment of the equine c mu and c gamma genes by deletion analysis of one IgM, four IgG and two equine light chain expressing heterohybridomas. This analysis establishes the existence of six c gamma genes per haploid genome. The genomic alignment of the cH-genes is 5' c mu/(/) c gamma 1/(/) c gamma 2/(/) c gamma 3/(/) c gamma 4/(/) c gamma 5/(/) c gamma 6/(/) c epsilon-c alpha 3', naming the c gamma genes according to their position relative to c mu. For three of the c gamma genes the corresponding IgG isotypes could be identified as IgGa for c gamma 1, IgG(T) for c gamma 3 and IgGb for c gamma 4.
Resumo:
The conversion of computed tomography (CT) numbers into material composition and mass density data influences the accuracy of patient dose calculations in Monte Carlo treatment planning (MCTP). The aim of our work was to develop a CT conversion scheme by performing a stoichiometric CT calibration. Fourteen dosimetrically equivalent tissue subsets (bins), of which ten bone bins, were created. After validating the proposed CT conversion scheme on phantoms, it was compared to a conventional five bin scheme with only one bone bin. This resulted in dose distributions D(14) and D(5) for nine clinical patient cases in a European multi-centre study. The observed local relative differences in dose to medium were mostly smaller than 5%. The dose-volume histograms of both targets and organs at risk were comparable, although within bony structures D(14) was found to be slightly but systematically higher than D(5). Converting dose to medium to dose to water (D(14) to D(14wat) and D(5) to D(5wat)) resulted in larger local differences as D(5wat) became up to 10% higher than D(14wat). In conclusion, multiple bone bins need to be introduced when Monte Carlo (MC) calculations of patient dose distributions are converted to dose to water.
Resumo:
This article proposes computing sensitivities of upper tail probabilities of random sums by the saddlepoint approximation. The considered sensitivity is the derivative of the upper tail probability with respect to the parameter of the summation index distribution. Random sums with Poisson or Geometric distributed summation indices and Gamma or Weibull distributed summands are considered. The score method with importance sampling is considered as an alternative approximation. Numerical studies show that the saddlepoint approximation and the method of score with importance sampling are very accurate. But the saddlepoint approximation is substantially faster than the score method with importance sampling. Thus, the suggested saddlepoint approximation can be conveniently used in various scientific problems.