6 resultados para Calculated, TEX86
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
To (1) establish the feasibility of texture analysis for the in vivo assessment of biochemical changes in meniscal tissue on delayed gadolinium-enhanced magnetic resonance imaging of cartilage (dGEMRIC), and (2) compare textural with conventional T1 relaxation time measurements calculated from dGEMRIC data ("T1(Gd) relaxation times").
Resumo:
BACKGROUND: A growing number of case reports have described tenofovir (TDF)-related proximal renal tubulopathy and impaired calculated glomerular filtration rates (cGFR). We assessed TDF-associated changes in cGFR in a large observational HIV cohort. METHODS: We compared treatment-naive patients or patients with treatment interruptions > or = 12 months starting either a TDF-based combination antiretroviral therapy (cART) (n = 363) or a TDF-sparing regime (n = 715). The predefined primary endpoint was the time to a 10 ml/min reduction in cGFR, based on the Cockcroft-Gault equation, confirmed by a follow-up measurement at least 1 month later. In sensitivity analyses, secondary endpoints including calculations based on the modified diet in renal disease (MDRD) formula were considered. Endpoints were modelled using pre-specified covariates in a multiple Cox proportional hazards model. RESULTS: Two-year event-free probabilities were 0.65 (95% confidence interval [CI] 0.58-0.72) and 0.80 (95% CI 0.76-0.83) for patients starting TDF-containing or TDF-sparing cART, respectively. In the multiple Cox model, diabetes mellitus (hazard ratio [HR] = 2.34 [95% CI 1.24-4.42]), higher baseline cGFR (HR = 1.03 [95% CI 1.02-1.04] by 10 ml/min), TDF use (HR = 1.84 [95% CI 1.35-2.51]) and boosted protease inhibitor use (HR = 1.71 [95% CI 1.30-2.24]) significantly increased the risk for reaching the primary endpoint. Sensitivity analyses showed high consistency. CONCLUSION: There is consistent evidence for a significant reduction in cGFR associated with TDF use in HIV-infected patients. Our findings call for a strict monitoring of renal function in long-term TDF users with tests that distinguish between glomerular dysfunction and proximal renal tubulopathy, a known adverse effect of TDF.
Resumo:
The S0 ↔ S1 spectra of the mild charge-transfer (CT) complexes perylene·tetrachloroethene (P·4ClE) and perylene·(tetrachloroethene)2 (P·(4ClE)2) are investigated by two-color resonant two-photon ionization (2C-R2PI) and dispersed fluorescence spectroscopy in supersonic jets. The S0 → S1 vibrationless transitions of P·4ClE and P·(4ClE)2 are shifted by δν = −451 and −858 cm–1 relative to perylene, translating to excited-state dissociation energy increases of 5.4 and 10.3 kJ/mol, respectively. The red shift is ∼30% larger than that of perylene·trans-1,2-dichloroethene; therefore, the increase in chlorination increases the excited-state stabilization and CT character of the interaction, but the electronic excitation remains largely confined to the perylene moiety. The 2C-R2PI and fluorescence spectra of P·4ClE exhibit strong progressions in the perylene intramolecular twist (1au) vibration (42 cm–1 in S0 and 55 cm–1 in S1), signaling that perylene deforms along its twist coordinate upon electronic excitation. The intermolecular stretching (Tz) and internal rotation (Rc) vibrations are weak; therefore, the P·4ClE intermolecular potential energy surface (IPES) changes little during the S0 ↔ S1 transition. The minimum-energy structures and inter- and intramolecular vibrational frequencies of P·4ClE and P·(4ClE)2 are calculated with the dispersion-corrected density functional theory (DFT) methods B97-D3, ωB97X-D, M06, and M06-2X and the spin-consistent-scaled (SCS) variant of the approximate second-order coupled-cluster method, SCS-CC2. All methods predict the global minima to be π-stacked centered coplanar structures with the long axis of tetrachloroethene rotated by τ ≈ 60° relative to the perylene long axis. The calculated binding energies are in the range of −D0 = 28–35 kJ/mol. A second minimum is predicted with τ ≈ 25°, with ∼1 kJ/mol smaller binding energy. Although both monomers are achiral, both the P·4ClE and P·(4ClE)2 complexes are chiral. The best agreement for adiabatic excitation energies and vibrational frequencies is observed for the ωB97X-D and M06-2X DFT methods.
Resumo:
BACKGROUND Oesophageal clearance has been scarcely studied. AIMS Oesophageal clearance in endoscopy-negative heartburn was assessed to detect differences in bolus clearance time among patients sub-grouped according to impedance-pH findings. METHODS In 118 consecutive endoscopy-negative heartburn patients impedance-pH monitoring was performed off-therapy. Acid exposure time, number of refluxes, baseline impedance, post-reflux swallow-induced peristaltic wave index and both automated and manual bolus clearance time were calculated. Patients were sub-grouped into pH/impedance positive (abnormal acid exposure and/or number of refluxes) and pH/impedance negative (normal acid exposure and number of refluxes), the former further subdivided on the basis of abnormal/normal acid exposure time (pH+/-) and abnormal/normal number of refluxes (impedance+/-). RESULTS Poor correlation (r=0.35) between automated and manual bolus clearance time was found. Manual bolus clearance time progressively decreased from pH+/impedance+ (42.6s), pH+/impedance- (27.1s), pH-/impedance+ (17.8s) to pH-/impedance- (10.8s). There was an inverse correlation between manual bolus clearance time and both baseline impedance and post-reflux swallow-induced peristaltic wave index, and a direct correlation between manual bolus clearance and acid exposure time. A manual bolus clearance time value of 14.8s had an accuracy of 93% to differentiate pH/impedance positive from pH/impedance negative patients. CONCLUSIONS When manually measured, bolus clearance time reflects reflux severity, confirming the pathophysiological relevance of oesophageal clearance in reflux disease.