13 resultados para Bubble

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigated vapor bubbles generated upon irradiation of gold nanoparticles with nanosecond laser pulses. Bubble formation was studied both with optical and acoustic means on supported single gold nanoparticles and single nanoparticles in suspension. Formation thresholds determined at different wavelengths indicate a bubble formation efficiency increasing with the irradiation wavelength. Vapor bubble generation in Bac-1 cells containing accumulations of the same particles was also investigated at different wavelengths. Similarly, they showed an increasing cell damage efficiency for longer wavelengths. Vapor bubbles generated by single laser pulses were about half the cell size when inducing acute damage.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In order to provide high precision stable carbon isotope ratios (δ13CO2 or δ13C of CO2) from small bubbly, partially and fully clathrated ice core samples we developed a new method based on sublimation coupled to gas chromatography-isotope ratio mass spectrometry (GC-IRMS). In a first step the trapped air is quantitatively released from ~30 g of ice and CO2 together with N2O are separated from the bulk air components and stored in a miniature glass tube. In an off-line step, the extracted sample is introduced into a helium carrier flow using a minimised tube cracker device. Prior to measurement, N2O and organic sample contaminants are gas chromatographically separated from CO2. Pulses of a CO2/N2O mixture are admitted to the tube cracker and follow the path of the sample through the system. This allows an identical treatment and comparison of sample and standard peaks. The ability of the method to reproduce δ13C from bubble and clathrate ice is verified on different ice cores. We achieve reproducibilities for bubble ice between 0.05 ‰ and 0.07 ‰ and for clathrate ice between 0.05 ‰ and 0.09 ‰ (dependent on the ice core used). A comparison of our data with measurements on bubble ice from the same ice core but using a mechanical extraction device shows no significant systematic offset. In addition to δ13C, the CO2 and N2O mixing ratios can be volumetrically derived with a precision of 2 ppmv and 8 ppbv, respectively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of the study was to review the literature reporting visual disturbance (VD) following sclerotherapy for varicose veins. Underlying mechanisms will be discussed. A literature search of the databases Medline and Google Scholar was performed. Original articles including randomized trials, case series and case reports reporting VD in humans following sclerotherapy for varicose veins were included. Additional references were also obtained if they had been referenced in related publications. The search yielded 4948 results of which 25 reports were found to meet the inclusion criteria. In larger series with at least 500 included patients the prevalence of VD following sclerotherapy ranges from 0.09% to 2%. In most reports foam sclerotherapy was associated with VD (19); exclusive use of liquid sclerosant was reported in two cases, some reports included foam and liquid sclerosant (4). There were no persistent visual disorders reported. VD occurred with polidocanol and sodium tetradecyl sulphate in different concentrations (0.25-3%). Various forms of foam preparation including various ways of foam production and the liquid - air ratio (1 or 2 parts of liquid mixed with 3, 4 or 5 parts of air) were reported in association with the occurrence of VD. VDs following sclerotherapy for varicose veins are rare and all reported events were transient. Bubble embolism or any kind of embolism seems unlikely to be the only underlying mechanism. A systemic inflammatory response following sclerotherapy has been suggested. Further research to clarify the mechanism of action of sclerosants is required.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Laser-assisted killing of gold nanoparticle targeted macrophages was investigated. Using pressure transient detection, flash photography and transmission electron microscopy (TEM) imaging, we studied the mechanism of single cell damage by vapor bubble formation around gold nanospheres induced by nanosecond laser pulses. The influence of the number of irradiating laser pulses and of particle size and concentration on the threshold for acute cell damage was determined. While the single pulse damage threshold is independent of the particle size, the threshold decreases with increasing particle size when using trains of pulses. The dependence of the cell damage threshold on the nanoparticle concentration during incubation reveals that particle accumulation and distribution inside the cell plays a key role in tissue imaging or cell damaging.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Medical literature regularly reports on accidental poisoning in children after aspiration of combustibles such as lamp oils which usually contain hydrocarbons or rape methyl esters (RMEs). We aimed to analyze the toxic potential of alkanes and different combustible classes in vitro with regard to biologic responses and mechanisms mediating toxicity. Two different in vitro models were used, i.e. (i) a captive bubble surfactometer (CBS) to assess direct influence of combustibles on biophysical properties of surfactant film and (ii) cell cultures (BEAS-2B and R3/1 cells, primary macrophages, re-differentiated epithelia) closely mimicking the inner lung surface. Biological endpoints included cell viability, cytotoxicity and inflammatory mediator release. CBS measurements demonstrate that combustibles affect film dynamics, i.e. the surface tension/area characteristics during compression and expansion, in a dose and molecular chain length dependent manner. Cell culture results confirm the dose dependent toxicity. Generally, cytotoxicity and cytokine release are higher in short-chained alkanes and hydrocarbon-based combustibles than in long-chained substances, e.g. highest inducible cytotoxicity in BEAS-2B was for hexane 84.6%, decane 74% and hexadecane 30.8%. Effects of RME-based combustibles differed between the cell models. Our results confirm data from animal experiments and give new insights into the mechanisms underlying the adverse health effects observed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Determining the formation temperature of minerals using fluid inclusions is a crucial step in understanding rock-forming scenarios. Unfortunately, fluid inclusions in minerals formed at low temperature, such as gypsum, are commonly in a metastable monophase liquid state. To overcome this problem, ultra-short laser pulses can be used to induce vapor bubble nucleation, thus creating a stable two-phase fluid inclusion appropriate for subsequent measurements of the liquid-vapor homogenization temperature, T-h. In this study we evaluate the applicability of T-h data to accurately determine gypsum formation temperatures. We used fluid inclusions in synthetic gypsum crystals grown in the laboratory at different temperatures between 40 degrees C and 80 degrees C under atmospheric pressure conditions. We found an asymmetric distribution of the T-h values, which are systematically lower than the actual crystal growth temperatures, T-g; this is due to (1) the effect of surface tension on liquid-vapor homogenization, and (2) plastic deformation of the inclusion walls due to internal tensile stress occurring in the metastable state of the inclusions. Based on this understanding, we have determined growth temperatures of natural giant gypsum crystals from Naica (Mexico), yielding 47 +/- 1.5 degrees C for crystals grown in the Cave of Swords (120 m below surface) and 54.5 +/- 2 degrees C for giant crystals grown in the Cave of Crystals (290 m below surface). These results support the earlier hypothesis that the population and the size of the Naica crystals were controlled by temperature. In addition, this experimental method opens a door to determining the growth temperature of minerals forming in low-temperature environments.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The water spider Argyroneta aquatica (Clerck) is the only spider that spends its whole life under water. Water spiders keep an air bubble around their body for breathing and build under-water air bells, which they use for shelter and raising offspring, digesting and consuming prey, moulting, depositing eggs and sperm, and copulating. It is unclear whether these bells are an important oxygen reservoir for breathing under water, or whether they serve mainly to create water-free space for feeding and reproduction. In this study, we manipulated the composition of the gas inside the bell of female water spiders to test whether they monitor the quality of this gas, and replenish oxygen if required. We exchanged the entire gas in the bell either with pure O(2), pure CO(2), or with ambient air as control, and monitored behavioural responses. The test spiders surfaced and replenished air more often in the CO(2) treatment than in the O(2) treatment, and they increased bell building behaviour. In addition to active oxygen regulation, they monitored and adjusted the bells by adding silk. These results show that water spiders use the air bell as an oxygen reservoir, and that it functions as an external lung, which renders it essential for living under water permanently. A. aquatica is the only animal that collects, transports, and stores air, and monitors its property for breathing, which is an adaptive response of a terrestrial animal to the colonization of an aquatic habitat. J. Exp. Zool. 307A:549-555, 2007. (c) 2007 Wiley-Liss, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Nebulized surfactant therapy has been proposed as an alternative method of surfactant administration. The use of a perforated vibrating membrane nebulizer provides a variety of advantages over conventional nebulizers. We investigated the molecular structure and integrity of poractant alfa pre- and post-nebulization. METHOD Curosurf® was nebulized using an Investigational eFlow® Nebulizer System. Non-nebulized surfactant ("NN"), recollected surfactant droplets from nebulization through an endotracheal tube ("NT") and nebulization of surfactant directly onto a surface ("ND") were investigated by transmission electron microscopy. Biophysical characteristics were assessed by the Langmuir-Wilhelmy balance and the Captive Bubble Surfactometer. RESULTS Volume densities of lamellar body-like forms (LBL) and multi-lamellar forms (ML) were high for "NN" and "NT" samples (38.8% vs. 47.7% for LBL and 58.2% vs. 47.8% for ML). In the "ND" sample, we found virtually no LBL's, ML's (72.6%) as well as uni-lamellar forms (16.4%) and a new structure, the "garland-like" forms (9.4%). Surface tension for "NN" and "NT" was 23.33 ± 0.29 and 25.77 ± 1.12 mN/m, respectively. Dynamic compression-expansion cycling minimum surface tensions were between 0.91 and 1.77 mN/m. CONCLUSION The similarity of surfactant characteristics of nebulized surfactant via a tube and the non-nebulized surfactant suggests that vibrating membrane nebulizers are suitable for surfactant nebulization. Alterations in surfactant morphology and characteristics after nebulization were transient. A new structural subtype of surfactant was identified. Pediatr Pulmonol. 2014; 49:348-356. © 2013 Wiley Periodicals, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of the study was to review the literature reporting visual disturbance (VD)following sclerotherapy for varicose veins. Underlying mechanisms will be discussed. A literature search of the databases Medline and Google Scholar was performed. Original articles including randomized trials, case series and case reports reporting VD in humans following sclerotherapy for varicose veins were included. Additional references were also obtained if they had been referenced in related publications. The search yielded 4948 results of which 25 reports were found to meet the inclusion criteria. In larger series with at least 500 included patients the prevalence of VD following sclerotherapy ranges from 0.09% to 2%. In most reports foam sclerotherapy was associated with VD (19); exclusive use of liquid sclerosant was reported in two cases, some reports included foam and liquid sclerosant (4). There were no persistent visual disorders reported. VD occurred with polidocanol and sodium tetradecyl sulphate in different concentrations (0.25–3%). Various forms of foam preparation including various ways of foam production and the liquid –air ratio (1 or 2 parts of liquid mixed with 3, 4 or 5 parts of air) were reported in association with the occurrence of VD. VDs following sclerotherapy for varicose veins are rare and all reported events were transient. Bubble embolism or any kind of embolism seems unlikely to be the only underlying mechanism. A systemic inflammatory response following sclerotherapy has been suggested. Further research to clarify the mechanism of action of sclerosants is required.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Liquid–vapour homogenisation temperatures of fluid inclusions in stalagmites are used for quantitative temperature reconstructions in paleoclimate research. Specifically for this application, we have developed a novel heating/cooling stage that can be operated with large stalagmite sections of up to 17 × 35 mm2 to simplify and improve the chronological reconstruction of paleotemperature time-series. The stage is designed for use of an oil immersion objective and a high-NA condenser front lens to obtain high-resolution images for bubble radius measurements. The temperature accuracy of the stage is better than ± 0.1 °C with a precision (reproducibility) of ± 0.02 °C.