59 resultados para Afferent feedback
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
We investigate a recently proposed model for decision learning in a population of spiking neurons where synaptic plasticity is modulated by a population signal in addition to reward feedback. For the basic model, binary population decision making based on spike/no-spike coding, a detailed computational analysis is given about how learning performance depends on population size and task complexity. Next, we extend the basic model to n-ary decision making and show that it can also be used in conjunction with other population codes such as rate or even latency coding.
Resumo:
Correctly performed basic life support (BLS) and early defibrillation are the most effective measures to treat sudden cardiac arrest. Audiovisual feedback improves BLS. Automated external defibrillators (AED) with feedback technology may play an important role in improving CPR quality. The aim of this simulation study was to investigate if an AED with audiovisual feedback improves CPR parameters during standard BLS performed by trained laypersons.
Resumo:
In the training of healthcare professionals, one of the advantages of communication training with simulated patients (SPs) is the SP's ability to provide direct feedback to students after a simulated clinical encounter. The quality of SP feedback must be monitored, especially because it is well known that feedback can have a profound effect on student performance. Due to the current lack of valid and reliable instruments to assess the quality of SP feedback, our study examined the validity and reliability of one potential instrument, the 'modified Quality of Simulated Patient Feedback Form' (mQSF). Methods Content validity of the mQSF was assessed by inviting experts in the area of simulated clinical encounters to rate the importance of the mQSF items. Moreover, generalizability theory was used to examine the reliability of the mQSF. Our data came from videotapes of clinical encounters between six simulated patients and six students and the ensuing feedback from the SPs to the students. Ten faculty members judged the SP feedback according to the items on the mQSF. Three weeks later, this procedure was repeated with the same faculty members and recordings. Results All but two items of the mQSF received importance ratings of > 2.5 on a four-point rating scale. A generalizability coefficient of 0.77 was established with two judges observing one encounter. Conclusions The findings for content validity and reliability with two judges suggest that the mQSF is a valid and reliable instrument to assess the quality of feedback provided by simulated patients.
Resumo:
PURPOSE: Limited information is available concerning changes in the urodynamic characteristics of orthotopic bladder substitutes with time. Therefore, we compared early and late urodynamic results in patients with an ileal orthotopic bladder substitute combined with an afferent tubular segment. MATERIALS AND METHODS: Of 139 patients surviving at least 5 years after cystoprostatectomy and ileal orthotopic bladder substitution with an afferent tubular segment 119 underwent urodynamic assessment, including 66 at a median of 9 months (early) and 77 at a median of 62 months (late). Of these patients 24 were assessed at each time point. Simultaneously all patients were asked to complete a bladder diary and questionnaire regarding continence for at least 3 days in the week preceding the urodynamic study. RESULTS: Urodynamic parameters were comparable in patients who were evaluated early and late postoperatively. In addition, median values at early and late urodynamic evaluation in the 24 patients with the 2 examinations showed no statistically significant differences for volume at first desire to void (300 vs 333 ml, p = 0.85), pressure at first desire to void (12 vs 13 cm H2O, p = 0.57), maximum cystometric capacity (450 vs 453 ml, p = 0.84), end filling pressure (19 vs 20 cm H2O, p = 0.17), reservoir compliance (25 vs 28 ml/cm H2O, p = 0.58) or post-void residual urine volume (5 vs 15 ml, p = 0.27). CONCLUSIONS: Urodynamic results after 5 years of living with an ileal orthotopic bladder substitute with an afferent tubular segment show grossly unchanged urodynamic characteristics. Patients maintain a reservoir capacity and micturition pattern consistent with a normal life-style. Reservoir pressure remained low, thereby protecting and preserving upper tract function. To achieve these results patients must be regularly followed, and the causes of bacteriuria, increased post-void residual urine and bladder outlet obstruction must be recognized and dealt with accordingly.
Resumo:
Competition and conflict among individuals can favour exploitative strategies that undermine the common good. Theory suggests that this can lead to a tragedy of the commons and ultimately population extinction, a phenomenon known as evolutionary suicide. Here, I present a model of the evolutionary tragedy of the commons that explicitly considers the population dynamics where individuals invest in individually costly competitive traits. In the simplest form, this supports the notion that selection for high levels of conflict can cause evolutionary suicide. However, as competition comes with survival and fecundity costs, a feedback between the investment in competition and population density can act to reduce the level of conflict and prevent the population from going extinct. This suggests that the interaction between population ecology and the evolution of competition and conflict among individuals may be an important mechanism in resolving the level of competition and conflict among individuals.