7 resultados para Adrenalin
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Although allergic emergencies do not occur every day, they are as unpredictable as the course of the reaction, and require rapid treatment. Anaphylaxis is a life-threatening general reaction that usually manifests within a few minutes after a known or potential antigen contact. While sole cutaneous symptoms are not sufficient to diagnose anaphylaxis, an episode of acute bronchospasm or hypotension in rare cases may be the only symptom. Almost always two or more organ systems are affected and usually the skin and/or mucous membranes are involved. Epinephrine (adrenaline) is the most important and effective drug in the treatment of anaphylaxis. Since there is no absolute contraindication, epinephrine should be administered intramuscularly at the first signs of anaphylaxis. However, there is a gap between the international treatment guidelines and the daily practice in the treatment of acute allergic, particularly anaphylactic, reactions. This is due not least to the fact that anaphylaxis, the most severe form of allergy, is not sufficiently clear or uniformly defined. After a systemic allergic reaction, all patients should be equipped with emergency medications, appropriately instructed obtain a complete allergy work-up.
Resumo:
Adrenalin-seeking airborne sports like BASE-jumping, paragliding, parachuting, delta-gliding, speedflying, and skysurfing are now firmly with us as outdoor lifestyle activities and are associated with a high frequency of severe injuries, especially to the spine.
Resumo:
BACKGROUND: Ibopamine is a non-selective dopamine- and adrenalin-receptor agonist that has been shown to cause pupillary dilation and an increase in aqueous humour secretion. This novel drug can be used as a mydriatic agent, as a provocative test in open-angle glaucoma, and for the treatment of persisting ocular hypotony. HISTORY AND SIGNS: This 47-year-old man had a history of uveitis associated with Crohn's disease. Six years after deep sclerectomy for uveitic secondary glaucoma, he developed severe hypotony in his left eye with drop of visual acuity (VA). The hypotony did not respond to topical steroid treatment. 2 % Ibopamine solution was ordered t. i. d. concomitant to 1 % prednisolone acetate. THERAPY AND OUTCOME: Intraocular pressure (IOP) began to rise after 3 weeks of Ibopamine treatment and returned to normal (12 mmHg) with continuous recovery of VA after 8 weeks. Ibopamine was discontinued at an IOP of 16 mmHg after a course of 12 weeks. IOP and VA remained stable during the 12-month follow-up period. CONCLUSIONS: Ibopamine 2 % eye drops in combination with topical steroids are a therapeutic option in uveitis-associated ocular hypotony.
Resumo:
OBJECTIVE To evaluate the effects of different hemostatic agents upon the outcome of periapical surgery. DESIGN A retrospective study was made of patients subjected to periapical surgery between 2006-2009 with the ultrasound technique and using MTA as retrograde filler material. We included patients with a minimum follow-up of 12 months, divided into two groups according to the hemostatic agent used: A) dressings impregnated in anesthetic solution with adrenalin; or B) aluminum chloride paste (Expasyl). Radiological controls were made after 6 and 12 months, and on the last visit. The global evolution scale proposed by von Arx and Kurt (1999) was used to establish the outcome of periapical surgery. RESULTS A total of 96 patients (42 males and 54 females) with a mean age of 40.7 years were included. There were 50 patients in the aluminum chloride group and 46 patients in the anesthetic solution with vasoconstrictor group. No significant differences were observed between the two groups in terms of outcome after 12 months - the success rate being 58.6% and 61.7% in the anesthetic solution with vasoconstrictor and aluminum chloride groups, respectively (p > 0.05). CONCLUSION The outcome after 12 months of follow-up was better in the aluminum chloride group than in the anesthetic solution with vasoconstrictor group, though the difference was not significant.
Resumo:
OBJECTIVES Percutaneous closure of the transapical (TA) access site for large-calibre devices is an unsolved issue. We report the first experimental data on the TA PLUG device for true-percutaneous closure following large apical access for transcatheter aortic valve implantation. METHODS The TA PLUG, a self-sealing full-core closure device, was implanted in an acute animal study in six pigs (60.2 ± 0.7 kg). All the pigs received 100 IU/kg of heparin. The targeted activated clotting time was left to normalize spontaneously. After accessing the left ventricular apex with a 39 French introducer, the closure plug device was delivered with a 33 French over-the-wire system under fluoroscopic guidance into the apex. Time to full haemostasis as well as rate of bleeding was recorded. Self-anchoring properties were assessed by haemodynamic push stress under adrenalin challenge. An additional feasibility study was conducted in four pigs (58.4 ± 1.1 kg) with full surgical exposure of the apex, and assessed device anchoring by pull-force measurements with 0.5 Newton (N) increments. All the animals were electively sacrified. Post-mortem analysis of the heart was performed and the renal embolic index assessed. RESULTS Of six apical closure devices, five were correctly inserted and fully deployed at the first attempt. One became blocked in the delivery system and was placed successfully at the second attempt. In all the animals, complete haemostasis was immediate and no leak was recorded during the 5-h observation period. Neither leak nor any device dislodgement was observed under haemodynamic push stress with repeated left ventricular peak pressure of up to 220 mmHg. In the feasibility study assessing pull-stressing, device migration occurred at a force of 3.3 ± 0.5 N corresponding to 247.5 mmHg. Post-mortem analyses confirmed full expansion of all devices at the intended target. No macroscopic damage was identified at the surrounding myocardium. The renal embolic index was zero. CONCLUSIONS True-percutaneous left ventricular apex closure following large access is feasible with the self-sealing TA PLUG. The device allows for immediate haemostasis and a reliable anchoring in the acute animal setting. This is the first report of a true-percutaneous closure for large-calibre transcatheter aortic valve implantation access.